The GW Instek APS-7100 power supply is controlled remotely with SCPI commands. TestFlow's instrument library holds 41 commands for it, 16 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the APS-7100 on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your GW Instek APS-7100 and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the GW Instek APS-7100's VISA address
# Paste the address of your GW Instek APS-7100 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write(":OUTPut ON") # Output On
print(inst.query(":MEASure:VOLTage:RMS?")) # Read Voltage RMS
inst.close()Describe the test; TestFlow's agent uses this command set to drive your GW Instek APS-7100 and writes the report from the measured results.
Describe the test in a sentence, for example “output on on the APS-7100, then read voltage rms and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
41 commands in 10 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| :SOURce:VOLTage <Vrms> | Set Voltage RMS. | Number |
| :SOURce:VOLTage:LIMit:RMS <Vrms> | Set Voltage Limit RMS. | Number |
| :SOURce:VOLTage:LIMit:RMS? | Read Voltage Limit RMS. | None |
| :SOURce:VOLTage:RANGe <Range> | Set Voltage Range. | Text: 155|310|600 |
| :SOURce:VOLTage:RANGe? | Read Voltage Range. | None |
| :SOURce:FREQuency <Hz> | Set Frequency. | Number |
| :SOURce:FREQuency? | Read Frequency. | None |
| :SOURce:FREQuency:LIMit:HIGH <Hz> | Set Frequency Limit. | Number |
| :SOURce:FREQuency:LIMit:HIGH? | Read Frequency Limit. | None |
| :SOURce:CURRent:LIMit:RMS <Amp> | Set Current Limit RMS. | Number |
| :SOURce:CURRent:LIMit:RMS? | Read Current Limit RMS. | None |
| :SOURce:CURRent:LIMit:PEAK:HIGH <Amp> | Set Current Limit Peak. | Number |
| :SOURce:CURRent:LIMit:PEAK:HIGH? | Read Current Limit Peak. | None |
| :SOURce:FUNCtion <Shape> | Set Waveform. | Text: SIN,ARB1,ARB2,ARB3,ARB4,ARB5,ARB6,ARB7,ARB8,ARB9,ARB10,ARB11,ARB12,ARB13,ARB14,ARB15,ARB16,ARB17,ARB18,ARB19,ARB20,ARB21,ARB22,CLP1,CLP2,CLP3 |
| :SOURce:FUNCtion? | Read Waveform. | None |
| :SOURce:PHASe:STARt <Deg> | Set Phase Start. | Number |
| :SOURce:PHASe:STOP <Deg> | Set Phase Stop. | Number |
| Command | What it does | Arguments |
|---|---|---|
| :MEASure:VOLTage:RMS? | Read Voltage RMS. | None |
| :MEASure:CURRent:RMS? | Measure Current RMS. | None |
| :MEASure:CURRent:HIGH? | Measure Current Peak. | None |
| :MEASure:CURRent:PEAK:CLEar | Clear Current Peak. | None |
| :MEASure:POWer:AC:REAL? | Measure Power Real. | None |
| :MEASure:POWer:AC:REACtive? | Measure Power Reactive. | None |
| :MEASure:POWer:AC:APParent? | Measure Power Apparent. | None |
| :MEASure:POWer:AC:PFACtor? | Measure Power Factor. | None |
| Command | What it does | Arguments |
|---|---|---|
| :OUTPut ON | Output On. | None |
| :OUTPut OFF | Output Off. | None |
| :OUTPut? | Read Output State. | None |
| :OUTPut:TRIGgered <State> | Output On Triggered. | Text: ON,OFF |
| Command | What it does | Arguments |
|---|---|---|
| :SYSTem:CONFigure:RAMP:MODE <Mode> | Set Ramp Mode. | Text: DISable,TIME,VOLTage |
| :SYSTem:CONFigure:RAMP:VOLTage <Vup>,<Vdn> | Set Ramp Voltage. | Number; Number |
| :SYSTem:CONFigure:RAMP:TIME <Tup_ms>,<Tdn_ms> | Set Ramp Time. | Number; Number |
| Command | What it does | Arguments |
|---|---|---|
| :MEMory:SAV <Slot> | Save Memory. | Number: 0-9 |
| :MEMory:RCL <Slot> | Recall Memory. | Number: 0-9 |
| Command | What it does | Arguments |
|---|---|---|
| :ABORt | Abort Trigger. | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Select_var> | Save2Variable. | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. | None |
| *RST | Reset. | None |
| *TRG | Trigger Immediate. | None |
This reference is generated from TestFlow's instrument library, which is drafted from GW Instek's programming documentation for the APS-7100 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by GW Instek's programming manual: check it before you rely on an edge case. Last updated November 12, 2026.
Yes. The GW Instek APS-7100 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 41 SCPI commands for it: 16 queries that read values or state, and 25 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, :OUTPut ON and :MEASure:VOLTage:RMS?.
:MEASure:VOLTage:RMS? (read voltage rms). The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the GW Instek APS-7100 through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.