Function Generator · SCPI command reference

GW Instek AFG-2112 SCPI commands

The GW Instek AFG-2112 function generator is controlled remotely with SCPI commands. TestFlow's instrument library holds 68 commands for it, 10 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the AFG-2112 on a real bench.

Commands
68
Queries
10
Subsystems
9
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your GW Instek AFG-2112 and writes the report from the measured results.

Get started

Control the GW Instek AFG-2112 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the GW Instek AFG-2112's VISA address

# Paste the address of your GW Instek AFG-2112 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("OUTPut ON")  # Turn On Output CH1
print(inst.query("OUTPut?"))  # Read Output State CH1

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your GW Instek AFG-2112 and writes the report from the measured results.

Get started

Run a AFG-2112 test without writing code

Describe the test in a sentence, for example “turn on output ch1 on the AFG-2112, then read output state ch1 and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

68 commands in 9 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Source (SOURce) (48)

CommandWhat it doesArguments
SOURce1:FUNCtion <Shape>Set Function CH1. Sets the output waveform shape for channel 1.Text: SINusoid,SQUare,RAMP,NOISe,USER
SOURce1:FUNCtion?Read Function CH1. Reads the output waveform shape for channel 1.None
SOURce1:FREQuency <Freq>Set Frequency CH1. Sets the output frequency in Hz for channel 1.Number
SOURce1:FREQuency?Read Frequency CH1. Reads the output frequency for channel 1.None
SOURce1:PERiod <Sec>Set Period CH1. Sets the output period in seconds for channel 1.Number
SOURce1:AMPlitude <Amp>Set Amplitude CH1. Sets the output amplitude (Vpp) for channel 1.Number
SOURce1:AMPlitude?Read Amplitude CH1. Reads the output amplitude for channel 1.None
SOURce1:DCOffset <Volt>Set Voltage Offset CH1. Sets the DC offset voltage for channel 1.Number
SOURce1:DCOffset?Read Voltage Offset CH1. Reads the DC offset voltage for channel 1.None
SOURce1:VOLTage:UNIT <Unit>Set Voltage Unit CH1. Sets the amplitude unit for channel 1.Text: VPP,VRMS,DBM
SOURce1:PHASe <Deg>Set Phase CH1. Sets the output phase in degrees for channel 1.Number
SOURce1:RAMP:SYMMetry <Pct>Set Ramp Symmetry CH1. Sets the ramp symmetry percentage for channel 1.Number: 0-100
SOURce1:SQUare:DCYCle <Pct>Set Square Duty Cycle CH1. Sets the square-wave duty cycle for channel 1.Number
SOURce1:PULSe:WIDTh <Sec>Set Pulse Width CH1. Sets the pulse width in seconds for channel 1.Number
SOURce1:PULSe:DCYCle <Pct>Set Pulse Duty Cycle CH1. Sets the pulse duty cycle for channel 1.Number
SOURce1:FUNCtion USERSet Arb Waveform CH1. Selects the arbitrary waveform for channel 1.None
SOURce1:AM:STATe ONEnable AM CH1. Enables AM modulation on channel 1.None
SOURce1:AM:STATe OFFDisable AM CH1. Disables AM modulation on channel 1.None
SOURce1:AM:DEPTh <Pct>Set AM Deviation CH1. Sets the AM depth percentage for channel 1.Number
SOURce1:AM:SOURce <Src>Set AM Source CH1. Sets the AM modulation source for channel 1.Text: INTernal,EXTernal
SOURce1:AM:INTernal:FREQuency <Freq>Set AM Int Freq CH1. Sets the internal AM modulating frequency for channel 1.Number
SOURce1:FM:STATe ONEnable FM CH1. Enables FM modulation on channel 1.None
SOURce1:FM:STATe OFFDisable FM CH1. Disables FM modulation on channel 1.None
SOURce1:FM:DEViation <Freq>Set FM Deviation CH1. Sets the FM frequency deviation for channel 1.Number
SOURce1:FM:SOURce <Src>Set FM Source CH1. Sets the FM modulation source for channel 1.Text: INTernal,EXTernal
SOURce1:FM:INTernal:FREQuency <Freq>Set FM Int Freq CH1. Sets the internal FM modulating frequency for channel 1.Number
SOURce1:PM:STATe ONEnable PM CH1. Enables PM modulation on channel 1.None
SOURce1:PM:STATe OFFDisable PM CH1. Disables PM modulation on channel 1.None
SOURce1:PM:DEViation <Deg>Set PM Deviation CH1. Sets the PM phase deviation for channel 1.Number
SOURce1:PM:SOURce <Src>Set PM Source CH1. Sets the PM modulation source for channel 1.Text: INTernal,EXTernal
SOURce1:PM:INTernal:FREQuency <Freq>Set PM Int Freq CH1. Sets the internal PM modulating frequency for channel 1.Number
SOURce1:FSKey:STATe ONEnable FSK CH1. Enables FSK modulation on channel 1.None
SOURce1:FSKey:STATe OFFDisable FSK CH1. Disables FSK modulation on channel 1.None
SOURce1:FSKey:FREQuency <Freq>Set FSK Hop Freq CH1. Sets the FSK hop frequency for channel 1.Number
SOURce1:PWM:STATe ONEnable PWM CH1. Enables PWM modulation on channel 1.None
SOURce1:PWM:STATe OFFDisable PWM CH1. Disables PWM modulation on channel 1.None
SOURce1:SWEep:STATe ONEnable Sweep CH1. Enables the frequency sweep on channel 1.None
SOURce1:SWEep:STATe OFFDisable Sweep CH1. Disables the frequency sweep on channel 1.None
SOURce1:SWEep:TIME <Sec>Set Sweep Time CH1. Sets the sweep time for channel 1.Number
SOURce1:SWEep:SPACing <Type>Set Sweep Spacing CH1. Sets the sweep spacing for channel 1.Text: LINear,LOGarithmic
SOURce1:FREQuency:STARt <Freq>Set Sweep Start Freq CH1. Sets the sweep start frequency for channel 1.Number
SOURce1:FREQuency:STOP <Freq>Set Sweep Stop Freq CH1. Sets the sweep stop frequency for channel 1.Number
SOURce1:BURSt:STATe ONEnable Burst CH1. Enables burst mode on channel 1.None
SOURce1:BURSt:STATe OFFDisable Burst CH1. Disables burst mode on channel 1.None
SOURce1:BURSt:MODE <Mode>Set Burst Mode CH1. Sets the burst mode for channel 1.Text: TRIGgered,GATed,INFinity
SOURce1:BURSt:NCYCles <N>Set Burst Cycles CH1. Sets the number of cycles per burst for channel 1.Number
SOURce1:BURSt:INTernal:PERiod <Sec>Set Burst Period CH1. Sets the internal burst period for channel 1.Number
SOURce1:BURSt:PHASe <Deg>Set Burst Phase CH1. Sets the burst start phase for channel 1.Number

Output (OUTPut) (4)

CommandWhat it doesArguments
OUTPut ONTurn On Output CH1. Enables channel 1 output.None
OUTPut OFFTurn Off Output CH1. Disables channel 1 output.None
OUTPut?Read Output State CH1. Reads channel 1 output state.None
OUTPut1:LOAD <Ohm>Set Output Load CH1. Sets channel 1 output load in ohms; use INFinity for high-Z.Number

COUN subsystem (3)

CommandWhat it doesArguments
COUNter:STATe ONEnable Counter. Enables the frequency counter.None
COUNter:STATe OFFDisable Counter. Disables the frequency counter.None
COUNter:VALue?Read Counter Frequency. Reads the measured frequency.None

Trigger (TRIGger) (1)

CommandWhat it doesArguments
TRIGger:SOURce <Src>Set Trigger Source. Sets the trigger source.Text: IMMediate,EXTernal,MANual,BUS

System (SYSTem) (1)

CommandWhat it doesArguments
SYSTem:ERRor?Read Error. Reads and clears the next error-queue entry.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (8)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*TST?Self Test. Runs the self-test and returns 0 for pass.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete.None
*SAV <Slot>Save State Slot. Stores the current state to a memory slot.Number
*RCL <Slot>Recall State Slot. Recalls a state from a memory slot.Number

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from GW Instek's programming documentation for the AFG-2112 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by GW Instek's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the GW Instek AFG-2112 support SCPI remote control?

Yes. The GW Instek AFG-2112 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 68 SCPI commands for it: 10 queries that read values or state, and 58 settings and actions.

How do I control the GW Instek AFG-2112 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut ON and OUTPut?.

Which command reads a value from the GW Instek AFG-2112?

OUTPut? (read output state ch1). Reads channel 1 output state. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the GW Instek AFG-2112 without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the GW Instek AFG-2112 through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.