The GW Instek GDM-8255A multimeter is controlled remotely with SCPI commands. TestFlow's instrument library holds 53 commands for it, 10 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the GDM-8255A on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your GW Instek GDM-8255A and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the GW Instek GDM-8255A's VISA address
# Paste the address of your GW Instek GDM-8255A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("CONFigure:VOLTage:DC") # Conf DCV
print(inst.query("CONF:STAT:FUNC?")) # Read Function
inst.close()Describe the test; TestFlow's agent uses this command set to drive your GW Instek GDM-8255A and writes the report from the measured results.
Describe the test in a sentence, for example “conf dcv on the GDM-8255A, then read function and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
53 commands in 11 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| CONFigure:VOLTage:DC | Conf DCV. Configures the meter to measure DC voltage on the primary display. | None |
| CONFigure:VOLTage:AC | Conf ACV. Configures the meter to measure AC voltage on the primary display. | None |
| CONFigure:CURRent:DC | Conf DCI. Configures the meter to measure DC current on the primary display. | None |
| CONFigure:CURRent:AC | Conf ACI. Configures the meter to measure AC current on the primary display. | None |
| CONFigure:RESistance | Conf 2W Resistance. Configures the meter to measure 2-wire resistance. | None |
| CONFigure:FRESistance | Conf 4W Resistance. Configures the meter to measure 4-wire resistance. | None |
| CONFigure:FREQuency | Conf Frequency. Configures the meter to measure frequency. | None |
| CONFigure:PERiod | Conf Period. Configures the meter to measure period. | None |
| CONFigure:TEMPerature | Conf Temperature. Configures the meter to measure temperature. | None |
| CONFigure:CONTinuity | Conf Continuity. Configures the meter for continuity testing. | None |
| CONFigure:DIODe | Conf Diode. Configures the meter for diode testing. | None |
| CONF:STAT:FUNC? | Read Function. Queries the present primary measurement function. | None |
| CONF:VOLT:DC ; READ? | Measure DCV. Configures DC voltage and returns one measured value in volts. | None |
| CONF:VOLT:AC ; READ? | Measure ACV. Configures AC voltage and returns one measured value in volts. | None |
| CONF:CURR:DC ; READ? | Measure DCI. Configures DC current and returns one measured value in amps. | None |
| CONF:CURR:AC ; READ? | Measure ACI. Configures AC current and returns one measured value in amps. | None |
| CONF:RES ; READ? | Measure 2W Resistance. Configures 2-wire resistance and returns one measured value in ohms. | None |
| CONF:FRES ; READ? | Measure 4W Resistance. Configures 4-wire resistance and returns one measured value in ohms. | None |
| CONF:FREQ ; READ? | Measure Frequency. Configures frequency and returns one measured value in Hz. | None |
| CONF:PER ; READ? | Measure Period. Configures period and returns one measured value in seconds. | None |
| CONF:TEMP ; READ? | Measure Temperature. Configures temperature and returns one measured value in degrees. | None |
| CONF:VOLT:DC <Range> | Set DCV Range. Sets the DC voltage measurement range in volts. | Number |
| CONF:VOLT:AC <Range> | Set ACV Range. Sets the AC voltage measurement range in volts. | Number |
| CONF:CURR:DC <Range> | Set DCI Range. Sets the DC current measurement range in amps. | Number |
| CONF:RES <Range> | Set Resistance Range. Sets the 2-wire resistance measurement range in ohms. | Number |
| CONF:AUTO 1 | DCV Autorange On. Enables autorange for DC voltage. | None |
| CONF:AUTO 0 | DCV Autorange Off. Disables autorange for DC voltage. | None |
| CONF2:OFF | Disable Second Display. Disables the secondary measurement display. | None |
| Command | What it does | Arguments |
|---|---|---|
| CALC:FUNC REL ; CALC:STAT 1 | Rel On. Enables the relative (null) operation. | None |
| CALC:STAT 0 | Rel Off. Disables the relative (null) operation. | None |
| CALC:FUNC DB ; CALC:STAT 1 | DB On. Enables the dB math operation. | None |
| CALC:FUNC DBM ; CALC:STAT 1 | DBm On. Enables the dBm math operation. | None |
| CALCulate:DBM:REFerence <Reference> | Set dBm Reference. Sets the dBm reference resistance in ohms. | Number |
| CALC:FUNC MAX ; CALC:STAT 1 | Statistics On. Enables the min/max/average statistics operation. | None |
| CALCulate:AVERage:MINimum? | Read Min. Returns the minimum of the collected statistics. | None |
| CALCulate:AVERage:MAXimum? | Read Max. Returns the maximum of the collected statistics. | None |
| CALCulate:AVERage:AVERage? | Read Average. Returns the average of the collected statistics. | None |
| Command | What it does | Arguments |
|---|---|---|
| TRIG:SOUR <Source> | Set Trigger Source. Sets the trigger source. | Text: INT,EXT |
| TRIGger:COUNt <Count> | Set Trigger Count. Sets the number of triggers accepted before returning to idle. | Number |
| Command | What it does | Arguments |
|---|---|---|
| READ? | Read Value. Triggers and returns one new measurement of the active function. | None |
| Command | What it does | Arguments |
|---|---|---|
| SAMPle:COUNt <Count> | Set Sample Count. Sets the number of samples taken per trigger. | Number |
| Command | What it does | Arguments |
|---|---|---|
| VAL2? | Read Second Value. Returns the secondary-display measured value. | None |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:ERRor? | Read Error. Reads the first message from the error queue. | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). | None |
| *RST | Reset. Resets the instrument to its default state. | None |
| *CLS | Clear Status. Clears all event registers and the error queue. | None |
| *TST? | Self Test. Runs the self-test and returns 0 for pass or 1 for failure. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *WAI | Wait To Continue. Waits until all pending operations are complete before continuing. | None |
| *TRG | Trigger Bus. Generates a bus trigger when the instrument is in wait-for-trigger state. | None |
This reference is generated from TestFlow's instrument library, which is drafted from GW Instek's programming documentation for the GDM-8255A and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by GW Instek's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The GW Instek GDM-8255A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 53 SCPI commands for it: 10 queries that read values or state, and 43 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, CONFigure:VOLTage:DC and CONF:STAT:FUNC?.
CONF:STAT:FUNC? (read function). Queries the present primary measurement function. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the GW Instek GDM-8255A through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.