Multimeter · SCPI command reference

GW Instek GDM-8255A SCPI commands

The GW Instek GDM-8255A multimeter is controlled remotely with SCPI commands. TestFlow's instrument library holds 53 commands for it, 10 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the GDM-8255A on a real bench.

Commands
53
Queries
10
Subsystems
11
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your GW Instek GDM-8255A and writes the report from the measured results.

Get started

Control the GW Instek GDM-8255A from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the GW Instek GDM-8255A's VISA address

# Paste the address of your GW Instek GDM-8255A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("CONFigure:VOLTage:DC")  # Conf DCV
print(inst.query("CONF:STAT:FUNC?"))  # Read Function

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your GW Instek GDM-8255A and writes the report from the measured results.

Get started

Run a GDM-8255A test without writing code

Describe the test in a sentence, for example “conf dcv on the GDM-8255A, then read function and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

53 commands in 11 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Configure (CONFigure) (28)

CommandWhat it doesArguments
CONFigure:VOLTage:DCConf DCV. Configures the meter to measure DC voltage on the primary display.None
CONFigure:VOLTage:ACConf ACV. Configures the meter to measure AC voltage on the primary display.None
CONFigure:CURRent:DCConf DCI. Configures the meter to measure DC current on the primary display.None
CONFigure:CURRent:ACConf ACI. Configures the meter to measure AC current on the primary display.None
CONFigure:RESistanceConf 2W Resistance. Configures the meter to measure 2-wire resistance.None
CONFigure:FRESistanceConf 4W Resistance. Configures the meter to measure 4-wire resistance.None
CONFigure:FREQuencyConf Frequency. Configures the meter to measure frequency.None
CONFigure:PERiodConf Period. Configures the meter to measure period.None
CONFigure:TEMPeratureConf Temperature. Configures the meter to measure temperature.None
CONFigure:CONTinuityConf Continuity. Configures the meter for continuity testing.None
CONFigure:DIODeConf Diode. Configures the meter for diode testing.None
CONF:STAT:FUNC?Read Function. Queries the present primary measurement function.None
CONF:VOLT:DC ; READ?Measure DCV. Configures DC voltage and returns one measured value in volts.None
CONF:VOLT:AC ; READ?Measure ACV. Configures AC voltage and returns one measured value in volts.None
CONF:CURR:DC ; READ?Measure DCI. Configures DC current and returns one measured value in amps.None
CONF:CURR:AC ; READ?Measure ACI. Configures AC current and returns one measured value in amps.None
CONF:RES ; READ?Measure 2W Resistance. Configures 2-wire resistance and returns one measured value in ohms.None
CONF:FRES ; READ?Measure 4W Resistance. Configures 4-wire resistance and returns one measured value in ohms.None
CONF:FREQ ; READ?Measure Frequency. Configures frequency and returns one measured value in Hz.None
CONF:PER ; READ?Measure Period. Configures period and returns one measured value in seconds.None
CONF:TEMP ; READ?Measure Temperature. Configures temperature and returns one measured value in degrees.None
CONF:VOLT:DC <Range>Set DCV Range. Sets the DC voltage measurement range in volts.Number
CONF:VOLT:AC <Range>Set ACV Range. Sets the AC voltage measurement range in volts.Number
CONF:CURR:DC <Range>Set DCI Range. Sets the DC current measurement range in amps.Number
CONF:RES <Range>Set Resistance Range. Sets the 2-wire resistance measurement range in ohms.Number
CONF:AUTO 1DCV Autorange On. Enables autorange for DC voltage.None
CONF:AUTO 0DCV Autorange Off. Disables autorange for DC voltage.None
CONF2:OFFDisable Second Display. Disables the secondary measurement display.None

Calculate (CALCulate) (9)

CommandWhat it doesArguments
CALC:FUNC REL ; CALC:STAT 1Rel On. Enables the relative (null) operation.None
CALC:STAT 0Rel Off. Disables the relative (null) operation.None
CALC:FUNC DB ; CALC:STAT 1DB On. Enables the dB math operation.None
CALC:FUNC DBM ; CALC:STAT 1DBm On. Enables the dBm math operation.None
CALCulate:DBM:REFerence <Reference>Set dBm Reference. Sets the dBm reference resistance in ohms.Number
CALC:FUNC MAX ; CALC:STAT 1Statistics On. Enables the min/max/average statistics operation.None
CALCulate:AVERage:MINimum?Read Min. Returns the minimum of the collected statistics.None
CALCulate:AVERage:MAXimum?Read Max. Returns the maximum of the collected statistics.None
CALCulate:AVERage:AVERage?Read Average. Returns the average of the collected statistics.None

Trigger (TRIGger) (2)

CommandWhat it doesArguments
TRIG:SOUR <Source>Set Trigger Source. Sets the trigger source.Text: INT,EXT
TRIGger:COUNt <Count>Set Trigger Count. Sets the number of triggers accepted before returning to idle.Number

Read (READ) (1)

CommandWhat it doesArguments
READ?Read Value. Triggers and returns one new measurement of the active function.None

SAMP subsystem (1)

CommandWhat it doesArguments
SAMPle:COUNt <Count>Set Sample Count. Sets the number of samples taken per trigger.Number

VAL subsystem (1)

CommandWhat it doesArguments
VAL2?Read Second Value. Returns the secondary-display measured value.None

System (SYSTem) (1)

CommandWhat it doesArguments
SYSTem:ERRor?Read Error. Reads the first message from the error queue.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (7)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*TST?Self Test. Runs the self-test and returns 0 for pass or 1 for failure.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete before continuing.None
*TRGTrigger Bus. Generates a bus trigger when the instrument is in wait-for-trigger state.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from GW Instek's programming documentation for the GDM-8255A and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by GW Instek's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the GW Instek GDM-8255A support SCPI remote control?

Yes. The GW Instek GDM-8255A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 53 SCPI commands for it: 10 queries that read values or state, and 43 settings and actions.

How do I control the GW Instek GDM-8255A from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, CONFigure:VOLTage:DC and CONF:STAT:FUNC?.

Which command reads a value from the GW Instek GDM-8255A?

CONF:STAT:FUNC? (read function). Queries the present primary measurement function. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the GW Instek GDM-8255A without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the GW Instek GDM-8255A through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.