Power Supply · SCPI command reference

Elektro-Automatik EA-PSI 9080-40 SCPI commands

The Elektro-Automatik EA-PSI 9080-40 power supply is controlled remotely with SCPI commands. TestFlow's instrument library holds 27 commands for it, 10 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the EA-PSI 9080-40 on a real bench.

Commands
27
Queries
10
Subsystems
9
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Elektro-Automatik EA-PSI 9080-40 and writes the report from the measured results.

Get started

Control the Elektro-Automatik EA-PSI 9080-40 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Elektro-Automatik EA-PSI 9080-40's VISA address

# Paste the address of your Elektro-Automatik EA-PSI 9080-40 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("OUTPut ON")  # Turn On
print(inst.query("MEASure:VOLTage:DC?"))  # Measure volt

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Elektro-Automatik EA-PSI 9080-40 and writes the report from the measured results.

Get started

Run a EA-PSI 9080-40 test without writing code

Describe the test in a sentence, for example “turn on on the EA-PSI 9080-40, then measure volt and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

27 commands in 9 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Source (SOURce) (12)

CommandWhat it doesArguments
SOURce:VOLTage <Volt>Set Voltage. Number
SOURce:VOLTage MINSet Voltage MIN. Text: MIN
SOURce:VOLTage MAXSet Voltage MAX. Text: MAX
SOURce:VOLTage?Read Set Voltage. None
SOURce:CURRent <Amp>Set Current. Number
SOURce:CURRent MINSet Current MIN. Text: MIN
SOURce:CURRent MAXSet Current MAX. Text: MAX
SOURce:CURRent?Read Set Current. None
SOURce:POWer <Watt>Set Power. Number
SOURce:POWer MINSet Power MIN. Text: MIN
SOURce:POWer MAXSet Power MAX. Text: MAX
SOURce:POWer?Read Set Power. None

Measurement (MEASure) (4)

CommandWhat it doesArguments
MEASure:VOLTage:DC?Measure volt. None
MEASure:CURRent:DC?Measure current. None
MEASure:POWer:DC?Measure power. None
MEASure:SCALar:ARRay?Measure array VIP. None

System (SYSTem) (3)

CommandWhat it doesArguments
SYSTem:LOCK ONRemote Control On. None
SYSTem:LOCK OFFRemote Control Off. None
SYSTem:ERRor?Read Error. None

Output (OUTPut) (3)

CommandWhat it doesArguments
OUTPut ONTurn On. None
OUTPut OFFTurn Off. None
OUTPut?Read State. None

TEST subsystem (1)

CommandWhat it doesArguments
testTest. None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Number

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Select_var>Save2Variable. Text

IEEE 488.2 common commands (1)

CommandWhat it doesArguments
*IDN?Identify. None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Elektro-Automatik's programming documentation for the EA-PSI 9080-40 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Elektro-Automatik's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Elektro-Automatik EA-PSI 9080-40 support SCPI remote control?

Yes. The Elektro-Automatik EA-PSI 9080-40 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 27 SCPI commands for it: 10 queries that read values or state, and 17 settings and actions.

How do I control the Elektro-Automatik EA-PSI 9080-40 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut ON and MEASure:VOLTage:DC?.

Which command reads a value from the Elektro-Automatik EA-PSI 9080-40?

MEASure:VOLTage:DC? (measure volt). The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Elektro-Automatik EA-PSI 9080-40 without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Elektro-Automatik EA-PSI 9080-40 through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today