The Elektro-Automatik BT 20010-600 dynamic load is controlled remotely with SCPI commands. TestFlow's instrument library holds 45 commands for it, 20 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the BT 20010-600 on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Elektro-Automatik BT 20010-600 and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Elektro-Automatik BT 20010-600's VISA address
# Paste the address of your Elektro-Automatik BT 20010-600 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("OUTPut ON") # Turn On
print(inst.query("MEASure:VOLTage?")) # Measure Voltage
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Elektro-Automatik BT 20010-600 and writes the report from the measured results.
Describe the test in a sentence, for example “turn on on the BT 20010-600, then measure voltage and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
45 commands in 10 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| SOURce:VOLTage <Voltage> | Set Voltage. Sets the output (charging) voltage set value from 0 to 80 V. | Number |
| SOURce:CURRent <Current> | Set Source Current. Sets the source (charge) current limit from 0 to 340 A. | Number |
| SOURce:POWer <Power> | Set Source Power. Sets the source (charge) power limit from 0 to 10000 W. | Number |
| SOURce:VOLTage? | Read Voltage Setting. Queries the currently set output voltage value. | None |
| SOURce:CURRent? | Read Source Current Setting. Queries the currently set source (charge) current limit. | None |
| SOURce:POWer? | Read Source Power Setting. Queries the currently set source (charge) power limit. | None |
| SOURce:VOLTage:PROTection <Voltage> | Set OVP Level. Sets the overvoltage protection (OVP) trip threshold in volts. | Number |
| SOURce:CURRent:PROTection <Current> | Set Source OCP Level. Sets the overcurrent protection (OCP) trip threshold for the source direction. | Number |
| SOURce:POWer:PROTection <Power> | Set Source OPP Level. Sets the overpower protection (OPP) trip threshold for the source direction. | Number |
| SOURce:VOLTage:LIMit:HIGH <Voltage> | Set Voltage Limit High. Sets the upper adjustment limit for the voltage set value. | Number |
| SOURce:VOLTage:LIMit:LOW <Voltage> | Set Voltage Limit Low. Sets the lower adjustment limit for the voltage set value. | Number |
| SOURce:CURRent:LIMit:HIGH <Current> | Set Current Limit High. Sets the upper adjustment limit for the source current set value. | Number |
| SOURce:CURRent:LIMit:LOW <Current> | Set Current Limit Low. Sets the lower adjustment limit for the source current set value. | Number |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:LOCK ON | Acquire Remote Control. Takes remote control of the device so set commands are accepted. | None |
| SYSTem:LOCK OFF | Release Remote Control. Releases remote control and returns the device to manual operation. | None |
| SYSTem:LOCK:OWNer? | Read Control Owner. Queries who currently owns control of the device (NONE or REMOTE). | None |
| SYSTem:NOMinal:VOLTage? | Read Nominal Voltage. Queries the rated nominal voltage of the device (80 V). | None |
| SYSTem:NOMinal:CURRent? | Read Nominal Current. Queries the rated nominal source current of the device (340 A). | None |
| SYSTem:NOMinal:POWer? | Read Nominal Power. Queries the rated nominal power of the device (10000 W per channel). | None |
| SYSTem:ERRor? | System Error. Queries the next entry in the error queue returning an error code and message. | None |
| Command | What it does | Arguments |
|---|---|---|
| SINK:CURRent <Current> | Set Sink Current. Sets the sink (discharge) current limit from 0 to 340 A. | Number |
| SINK:POWer <Power> | Set Sink Power. Sets the sink (discharge) power limit from 0 to 10000 W. | Number |
| SINK:CURRent? | Read Sink Current Setting. Queries the currently set sink (discharge) current limit. | None |
| SINK:POWer? | Read Sink Power Setting. Queries the currently set sink (discharge) power limit. | None |
| SINK:CURRent:PROTection <Current> | Set Sink OCP Level. Sets the overcurrent protection (OCP) trip threshold for the sink direction. | Number |
| SINK:POWer:PROTection <Power> | Set Sink OPP Level. Sets the overpower protection (OPP) trip threshold for the sink direction. | Number |
| Command | What it does | Arguments |
|---|---|---|
| MEASure:VOLTage? | Measure Voltage. Measures and returns the actual output voltage at the DC terminals. | None |
| MEASure:CURRent? | Measure Current. Measures and returns the actual current (positive sourcing or negative sinking). | None |
| MEASure:POWer? | Measure Power. Measures and returns the actual output power in watts. | None |
| MEASure:ARRay? | Measure Array. Measures and returns actual voltage current and power together in one query. | None |
| Command | What it does | Arguments |
|---|---|---|
| OUTPut ON | Turn On. Enables the DC output of the channel. | None |
| OUTPut OFF | Turn Off. Disables the DC output of the channel. | None |
| OUTPut? | Read Output State. Queries whether the DC output is ON or OFF. | None |
| Command | What it does | Arguments |
|---|---|---|
| STATus:QUEStionable:CONDition? | Read Questionable Status. Queries the questionable status condition register (alarms such as OVP OCP OT). | None |
| STATus:OPERation:CONDition? | Read Operation Status. Queries the operation status condition register (CV CC CP CR and output state). | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the instrument identification string including manufacturer model serial number and firmware. | None |
| *RST | Reset. Resets the device to its default state and switches the DC output off. | None |
| *CLS | Clear Status. Clears the status byte and all event registers and the error queue. | None |
| *ESE <Value> | Set Event Status Enable. Sets the event status enable register to select which events set the ESB bit. | Number |
| *ESR? | Read Event Status. Queries and clears the standard event status register. | None |
| *STB? | Read Status Byte. Queries the status byte register without clearing it. | None |
| *SRE <Value> | Set Service Request Enable. Sets the service request enable register to control which status bits generate an SRQ. | Number |
This reference is generated from TestFlow's instrument library, which is drafted from Elektro-Automatik's programming documentation for the BT 20010-600 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Elektro-Automatik's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The Elektro-Automatik BT 20010-600 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 45 SCPI commands for it: 20 queries that read values or state, and 25 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut ON and MEASure:VOLTage?.
MEASure:VOLTage? (measure voltage). Measures and returns the actual output voltage at the DC terminals. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Elektro-Automatik BT 20010-600 through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.