The Elektro-Automatik EA PSB-11000-80 power supply is controlled remotely with SCPI commands. TestFlow's instrument library holds 59 commands for it, 29 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the EA PSB-11000-80 on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Elektro-Automatik EA PSB-11000-80 and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Elektro-Automatik EA PSB-11000-80's VISA address
# Paste the address of your Elektro-Automatik EA PSB-11000-80 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write(":OUTPut ON") # Turn On
print(inst.query(":MEASure:VOLTage?")) # Measure Voltage
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Elektro-Automatik EA PSB-11000-80 and writes the report from the measured results.
Describe the test in a sentence, for example “turn on on the EA PSB-11000-80, then measure voltage and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
59 commands in 10 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| :SOURce:VOLTage <Voltage> | Set Voltage. Sets the voltage set value in volts (0 to 102% of 1000 V rating). The single voltage set value is valid for both source and sink operation. | Number |
| :SOURce:VOLTage? | Read Voltage Setting. Queries the currently set voltage value in volts. | None |
| :SOURce:CURRent <Current> | Set Source Current. Sets the current set value in amperes for source (power supply) operation (0 to 102% of 80 A rating). | Number |
| :SOURce:CURRent? | Read Source Current Setting. Queries the currently set source mode current value in amperes. | None |
| :SOURce:POWer <Power> | Set Source Power. Sets the power set value in watts for source operation (0 to 102% of 30000 W rating). | Number |
| :SOURce:POWer? | Read Source Power Setting. Queries the currently set source mode power value in watts. | None |
| :SOURce:RESistance <Resistance> | Set Source Resistance. Sets the simulated internal resistance value in ohms for source operation. Requires resistance mode to be activated first. | Number |
| :SOURce:RESistance? | Read Source Resistance Setting. Queries the currently set source mode resistance value in ohms. | None |
| :SOURce:VOLTage:PROTection <OVP> | Set OVP Level. Sets the overvoltage protection threshold in volts (0 to 110% of 1000 V rating). The DC terminal is switched off when exceeded. | Number |
| :SOURce:VOLTage:PROTection? | Read OVP Level. Queries the currently set overvoltage protection threshold in volts. | None |
| :SOURce:CURRent:PROTection <OCP> | Set Source OCP Level. Sets the overcurrent protection threshold in amperes for source operation (0 to 110% of 80 A rating). | Number |
| :SOURce:CURRent:PROTection? | Read Source OCP Level. Queries the source mode overcurrent protection threshold in amperes. | None |
| :SOURce:POWer:PROTection <OPP> | Set Source OPP Level. Sets the overpower protection threshold in watts for source operation (0 to 110% of 30000 W rating). | Number |
| :SOURce:POWer:PROTection? | Read Source OPP Level. Queries the source mode overpower protection threshold in watts. | None |
| :SOURce:VOLTage:LIMit:HIGH <Limit> | Set Voltage Limit High. Sets the upper adjustment limit for the voltage set value in volts to protect the DUT from too high settings. | Number |
| :SOURce:VOLTage:LIMit:LOW <Limit> | Set Voltage Limit Low. Sets the lower adjustment limit for the voltage set value in volts. | Number |
| :SOURce:CURRent:LIMit:HIGH <Limit> | Set Source Current Limit High. Sets the upper adjustment limit for the source mode current set value in amperes. | Number |
| :SOURce:CURRent:LIMit:LOW <Limit> | Set Source Current Limit Low. Sets the lower adjustment limit for the source mode current set value in amperes. | Number |
| :SOURce:POWer:LIMit:HIGH <Limit> | Set Source Power Limit High. Sets the upper adjustment limit for the source mode power set value in watts. | Number |
| Command | What it does | Arguments |
|---|---|---|
| :SINK:CURRent <Current> | Set Sink Current. Sets the current set value in amperes for sink (electronic load) operation (0 to 102% of 80 A rating). | Number |
| :SINK:CURRent? | Read Sink Current Setting. Queries the currently set sink mode current value in amperes. | None |
| :SINK:POWer <Power> | Set Sink Power. Sets the power set value in watts for sink operation (0 to 102% of 30000 W rating). | Number |
| :SINK:POWer? | Read Sink Power Setting. Queries the currently set sink mode power value in watts. | None |
| :SINK:RESistance <Resistance> | Set Sink Resistance. Sets the resistance value in ohms for constant resistance operation in sink mode. Requires resistance mode to be activated first. | Number |
| :SINK:RESistance? | Read Sink Resistance Setting. Queries the currently set sink mode resistance value in ohms. | None |
| :SINK:CURRent:PROTection <OCP> | Set Sink OCP Level. Sets the overcurrent protection threshold in amperes for sink operation (0 to 110% of 80 A rating). | Number |
| :SINK:CURRent:PROTection? | Read Sink OCP Level. Queries the sink mode overcurrent protection threshold in amperes. | None |
| :SINK:POWer:PROTection <OPP> | Set Sink OPP Level. Sets the overpower protection threshold in watts for sink operation (0 to 110% of 30000 W rating). | Number |
| :SINK:POWer:PROTection? | Read Sink OPP Level. Queries the sink mode overpower protection threshold in watts. | None |
| :SINK:CURRent:LIMit:HIGH <Limit> | Set Sink Current Limit High. Sets the upper adjustment limit for the sink mode current set value in amperes. | Number |
| :SINK:POWer:LIMit:HIGH <Limit> | Set Sink Power Limit High. Sets the upper adjustment limit for the sink mode power set value in watts. | Number |
| Command | What it does | Arguments |
|---|---|---|
| :SYSTem:LOCK ON | Enable Remote Control. Switches the device to remote control. Must be sent first before any command that changes values or status is accepted. | None |
| :SYSTem:LOCK OFF | Disable Remote Control. Exits remote control and returns the device to manual control. | None |
| :SYSTem:LOCK:OWNer? | Read Remote Control State. Queries the remote control state and returns REMOTE NONE or LOCAL. | None |
| :SYSTem:CONFig:MODE UIR | Set Resistance Mode On. Activates internal resistance mode (UIR) so the source and sink resistance set values become effective. | None |
| :SYSTem:CONFig:MODE UIP | Set Resistance Mode Off. Deactivates resistance mode and returns the device to standard voltage/current/power (UIP) operation. | None |
| :SYSTem:NOMinal:VOLTage? | Read Nominal Voltage. Queries the rated (nominal) voltage of the device (1000 V for this model). | None |
| :SYSTem:NOMinal:CURRent? | Read Nominal Current. Queries the rated (nominal) current of the device (80 A for this model). | None |
| :SYSTem:NOMinal:POWer? | Read Nominal Power. Queries the rated (nominal) power of the device (30000 W for this model). | None |
| :SYSTem:ERRor? | System Error. Queries the next error from the error queue as error code and text. Reading errors also acknowledges receded device alarms in the questionable register. | None |
| :SYSTem:ERRor:ALL? | System Error All. Queries all errors in the error buffer (up to 5) in one string and purges the buffer. | None |
| Command | What it does | Arguments |
|---|---|---|
| :MEASure:VOLTage? | Measure Voltage. Measures and returns the actual voltage on the DC terminal in volts. | None |
| :MEASure:CURRent? | Measure Current. Measures and returns the actual current in amperes. A negative value indicates sink mode (current flowing into the device). | None |
| :MEASure:POWer? | Measure Power. Measures and returns the actual power in watts. A negative value indicates sink mode operation. | None |
| :MEASure:ARRay? | Measure All. Measures and returns the actual voltage current and power values together in one snapshot. | None |
| Command | What it does | Arguments |
|---|---|---|
| :STATus:OPERation:CONDition? | Read Operation Status. Reads the operation condition register with bits for regulation mode (CV CC CP CR) remote control DC terminal on and function generator run. | None |
| :STATus:OPERation? | Read Operation Events. Reads and clears the operation event register recording positive transitions of the operation status bits. | None |
| :STATus:QUEStionable:CONDition? | Read Alarm Status. Reads the questionable condition register with the device alarm bits (OVP OCP OPP OT power fail and supervision events). | None |
| :STATus:QUEStionable? | Read Alarm Events. Reads and clears the questionable event register recording occurred device alarms and events. | None |
| Command | What it does | Arguments |
|---|---|---|
| :OUTPut ON | Turn On. Switches the DC terminal on (device sources or sinks depending on the connected circuit and set values). | None |
| :OUTPut OFF | Turn Off. Switches the DC terminal off. | None |
| :OUTPut? | Read State. Queries if the DC terminal is ON or OFF. | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *RST | Reset. Sets the device to a defined state: activates remote control switches the DC terminal off clears the alarm buffer and resets the status registers. | None |
| *IDN? | Identify. Queries the identification string containing manufacturer model name serial number firmware versions and user text. | None |
| *CLS | Clear Status. Clears the SCPI error queue and the status byte register. | None |
| *STB? | Read Status Byte. Reads the status byte register with summary bits for the error queue and the questionable and operation status registers. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Elektro-Automatik's programming documentation for the EA PSB-11000-80 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Elektro-Automatik's programming manual: check it before you rely on an edge case. Last updated July 16, 2026.
Yes. The Elektro-Automatik EA PSB-11000-80 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 59 SCPI commands for it: 29 queries that read values or state, and 30 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, :OUTPut ON and :MEASure:VOLTage?.
:MEASure:VOLTage? (measure voltage). Measures and returns the actual voltage on the DC terminal in volts. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Elektro-Automatik EA PSB-11000-80 through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.