Oscilloscope · SCPI command reference

Tektronix TDS724A SCPI commands

The Tektronix TDS724A oscilloscope is controlled remotely with SCPI commands. TestFlow's instrument library holds 237 commands for it, 133 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the TDS724A on a real bench.

Commands
237
Queries
133
Subsystems
25
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Tektronix TDS724A and writes the report from the measured results.

Get started

Control the Tektronix TDS724A from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Tektronix TDS724A's VISA address

# Paste the address of your Tektronix TDS724A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("AUTOSET")  # Autoset
print(inst.query("MEASUrement:REFLevel:PERCent:HIGH?"))  # Query Percent High Reference

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Tektronix TDS724A and writes the report from the measured results.

Get started

Run a TDS724A test without writing code

Describe the test in a sentence, for example “autoset on the TDS724A, then query percent high reference and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

237 commands in 25 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

MEASU subsystem (55)

CommandWhat it doesArguments
MEASUrement?Query All Measurements. Returns all measurement parameters.None
MEASUrement:GATing <state>Set Measurement Gating. Turns measurement gating on or off.Text: ON, OFF
MEASUrement:GATing?Query Measurement Gating. Returns the measurement gating state.None
MEASUrement:IMMed:TYPe <type>Set Immediate Measurement Type. Sets the type of the immediate measurement.Text: measurement type keyword from the manual list (for example the frequency type)
MEASUrement:IMMed:TYPe?Query Immediate Measurement Type. Returns the type of the immediate measurement.None
MEASUrement:IMMed:VALue?Read Immediate Measurement Value. Executes the immediate measurement and returns its value.None
MEASUrement:IMMed:UNITS?Query Immediate Measurement Units. Returns the units of the immediate measurement.None
MEASUrement:IMMed:SOURCE1 <source>Set Immediate Measurement Source 1. Sets the source for single channel immediate measurements and the delay from source.Text: CH1 to CH4, MATH1 to MATH3, REF1 to REF4
MEASUrement:IMMed:SOURCE1?Query Immediate Measurement Source 1. Returns the immediate measurement source 1.None
MEASUrement:IMMed:SOURCE2 <source>Set Immediate Measurement Source 2. Sets the source to measure to when taking an immediate delay or phase measurement.Text: CH1 to CH4, MATH1 to MATH3, REF1 to REF4
MEASUrement:IMMed:SOURCE2?Query Immediate Measurement Source 2. Returns the immediate measurement source 2.None
MEASUrement:IMMed:DELay:EDGE1 <slope>Set Immediate Delay Edge 1. Sets the slope of the edge used on the delay from waveform.Text: RISe, FALL
MEASUrement:IMMed:DELay:EDGE1?Query Immediate Delay Edge 1. Returns the slope of the immediate delay from edge.None
MEASUrement:IMMed:DELay:EDGE2 <slope>Set Immediate Delay Edge 2. Sets the slope of the edge used on the delay to waveform.Text: RISe, FALL
MEASUrement:IMMed:DELay:EDGE2?Query Immediate Delay Edge 2. Returns the slope of the immediate delay to edge.None
MEASUrement:IMMed:DELay?Query Immediate Delay Measurement. Returns the immediate delay measurement setup.None
MEASUrement:MEAS<x>:TYPe <type>Set Measurement Type. Sets the type of the displayed measurement.Text: measurement type keyword from the manual list
MEASUrement:MEAS<x>:TYPe?Query Measurement Type. Returns the type of the measurement.None
MEASUrement:MEAS<x>:VALue?Read Measurement Value. Returns the displayed value of the measurement.None
MEASUrement:MEAS<x>:UNITS?Query Measurement Units. Returns the units for the measurement.None
MEASUrement:MEAS<x>?Query All Measurement Parameters. Returns all parameters of the displayed measurement.None
MEASUrement:MEAS<x>:STATE <state>Set Measurement State. Turns the measurement on or off.Text: ON, OFF or 1, 0
MEASUrement:MEAS<x>:STATE?Query Measurement State. Returns the state of the measurement.None
MEASUrement:MEAS<x>:SOURCE1 <source>Set Measurement Source 1. Sets the measurement source for single channel measurements.Text: CH1 to CH4, MATH1 to MATH3, REF1 to REF4
MEASUrement:MEAS<x>:SOURCE1?Query Measurement Source 1. Returns the measurement source 1.None
MEASUrement:MEAS<x>:SOURCE2 <source>Set Measurement Source 2. Sets the source to measure to for delay or phase measurements.Text: CH1 to CH4, MATH1 to MATH3, REF1 to REF4
MEASUrement:MEAS<x>:SOURCE2?Query Measurement Source 2. Returns the measurement source 2.None
MEASUrement:MEAS<x>:DELay:EDGE1 <slope>Set Measurement Delay Edge 1. Sets the slope of the edge used on the delay from waveform.Text: RISe, FALL
MEASUrement:MEAS<x>:DELay:EDGE1?Query Measurement Delay Edge 1. Returns the slope of the delay from edge.None
MEASUrement:MEAS<x>:DELay:EDGE2 <slope>Set Measurement Delay Edge 2. Sets the slope of the edge used on the delay to waveform.Text: RISe, FALL
MEASUrement:MEAS<x>:DELay:EDGE2?Query Measurement Delay Edge 2. Returns the slope of the delay to edge.None
MEASUrement:MEAS<x>:DELay?Query Measurement Delay Parameters. Returns the delay measurement parameters.None
MEASUrement:MEAS<x>:MEAN?Query Measurement Mean. Returns the mean accumulated for the measurement (TDS 500C and 700C only).None
MEASUrement:MEAS<x>:MAXimum?Query Measurement Maximum. Returns the maximum value since the last statistical reset (TDS 500C and 700C only).None
MEASUrement:MEAS<x>:MINImum?Query Measurement Minimum. Returns the minimum value since the last statistical reset (TDS 500C and 700C only).None
MEASUrement:MEAS<x>:STDdev?Query Measurement Standard Deviation. Returns the standard deviation of accumulated values (TDS 500C and 700C only).None
MEASUrement:METHod <method>Set Measurement Method. Sets the method used to calculate the 0% and 100% reference levels.Text: HISTogram, MINMax, or the method keyword from the manual
MEASUrement:METHod?Query Measurement Method. Returns the method used for the reference levels.None
MEASUrement:REFLevel?Query Reference Levels. Returns the reference levels.None
MEASUrement:REFLevel:METHod <method>Set Reference Level Method. Specifies which reference levels are used for measurements.Text: ABSolute, PERCent, or the statistical method keyword
MEASUrement:REFLevel:METHod?Query Reference Level Method. Returns the reference level method in use.None
MEASUrement:REFLevel:ABSolute:HIGH <level>Set Absolute High Reference. Sets the high (100%) absolute reference level.Number: high reference level in volts, default 0.0
MEASUrement:REFLevel:ABSolute:HIGH?Query Absolute High Reference. Returns the absolute high reference level.None
MEASUrement:REFLevel:ABSolute:LOW <level>Set Absolute Low Reference. Sets the low (0%) absolute reference level.Number: low reference level in volts, default 0.0
MEASUrement:REFLevel:ABSolute:LOW?Query Absolute Low Reference. Returns the absolute low reference level.None
MEASUrement:REFLevel:ABSolute:MID <level>Set Absolute Mid Reference. Sets the mid (50%) absolute reference level.Number: mid reference level in volts, default 0.0
MEASUrement:REFLevel:ABSolute:MID?Query Absolute Mid Reference. Returns the absolute mid reference level.None
MEASUrement:REFLevel:PERCent:HIGH <percent>Set Percent High Reference. Sets the high reference level as a percent of HIGH.Number: 0 to 100 percent of HIGH, default 90
MEASUrement:REFLevel:PERCent:HIGH?Query Percent High Reference. Returns the percent high reference level.None
MEASUrement:REFLevel:PERCent:LOW <percent>Set Percent Low Reference. Sets the low reference level as a percent of HIGH.Number: 0 to 100 percent of HIGH, default 10
MEASUrement:REFLevel:PERCent:LOW?Query Percent Low Reference. Returns the percent low reference level.None
MEASUrement:REFLevel:PERCent:MID <percent>Set Percent Mid Reference. Sets the mid reference level as a percent of HIGH.Number: 0 to 100 percent of HIGH, default 50
MEASUrement:REFLevel:PERCent:MID?Query Percent Mid Reference. Returns the percent mid reference level.None
MEASUrement:STATIstics:MODE?Query Statistics Mode. Returns the measurement statistics mode.None
MEASUrement:STATIstics:WEIghting <weight>Set Statistics Weighting. Sets the responsiveness of mean and standard deviation (TDS 500C and 700C only).Number: time constant for mean and standard deviation accumulations

WFMPRE subsystem (32)

CommandWhat it doesArguments
WFMPRE?Query Waveform Format. Returns the waveform formatting data for the first ordered waveform.None
WFMPRE:BIT_NR?Query Bits Per Point. Returns the number of bits per binary waveform point (8 or 16).None
WFMPRE:BN_FMT <format>Set Binary Data Format. Sets the format of binary waveform data.Text: RI (signed integer) or RP (positive integer)
WFMPRE:BN_FMT?Query Binary Data Format. Returns the binary data format (RI or RP).None
WFMPRE:BYT_NR <width>Set Bytes Per Point. Sets the binary data width for the waveform.Number: 1 or 2 bytes per point
WFMPRE:BYT_NR?Query Bytes Per Point. Returns the binary data width in bytes per point.None
WFMPRE:BYT_OR <order>Set Byte Order. Selects which byte of 2-byte binary data is transmitted first.Text: LSB or MSB
WFMPRE:BYT_OR?Query Byte Order. Returns which byte is transmitted first (LSB or MSB).None
WFMPRE:ENCDG <encoding>Set Curve Encoding. Sets the encoding of waveform data sent with CURVE.Text: ASC (ASCII) or BIN (binary)
WFMPRE:ENCDG?Query Curve Encoding. Returns the waveform data encoding (ASC or BIN).None
WFMPRE:PT_FMT <format>Set Point Format. Selects the data point format of the waveform (enveloped or normal).Text: ENVelope or Y
WFMPRE:PT_OFF <position>Set Trigger Point Offset. Sets the trigger point within the reference waveform record.Number: 0 to the record length
WFMPRE:XINCR <interval>Set Horizontal Sample Interval. Sets the horizontal sampling interval of the reference waveform.Number: sampling interval in seconds per point
WFMPRE:YMULT <scale>Set Vertical Scale Factor. Sets the vertical scale factor of the reference waveform.Number: vertical scale factor in YUNits per division
WFMPRE:YOFF <offset>Set Vertical Offset Level. Sets the vertical offset in digitizing levels of the reference waveform.Number: offset in digitizing levels
WFMPRE:YZERO <offset>Set Vertical Offset Voltage. Sets the offset voltage of the reference waveform.Number: offset in YUNits (usually volts)
WFMPRE:<wfm>?Query Waveform Format For Source. Returns the waveform formatting data for the given waveform (must be displayed).Text: CH<x>, MATH<x>, or REF<x>
WFMPRE:<wfm>:NR_PT?Query Number Of Points. Returns the number of points in the transmitted waveform record.Text: CH<x>, MATH<x>, or REF<x>
WFMPRE:<wfm>:PT_FMT <format>Set Point Format For Source. Sets the data point format for the given waveform.Text: ENVelope or Y
WFMPRE:<wfm>:PT_FMT?Query Point Format For Source. Returns the data point format of the given waveform.Text: CH<x>, MATH<x>, or REF<x>
WFMPRE:<wfm>:PT_OFF?Query Trigger Point Offset For Source. Returns the trigger point position within the waveform record.Text: CH<x>, MATH<x>, or REF<x>
WFMPRE:<wfm>:WFID?Query Waveform Identifier. Returns the waveform identifier string (coupling, volts/div, time/div, mode, record length).Text: CH<x>, MATH<x>, or REF<x>
WFMPRE:<wfm>:XINCR <interval>Set Horizontal Interval For Source. Sets the horizontal sampling interval for the given waveform.Number: sampling interval in seconds
WFMPRE:<wfm>:XINCR?Query Horizontal Interval For Source. Returns the horizontal sampling interval of the given waveform.Text: CH<x>, MATH<x>, or REF<x>
WFMPRE:<wfm>:XUNIT?Query Horizontal Units. Returns the horizontal units of the waveform data (seconds).Text: CH<x>, MATH<x>, or REF<x>
WFMPRE:<wfm>:YMULT <scale>Set Vertical Scale For Source. Sets the vertical scale factor for the given waveform.Number: scale factor in YUNits per digitizing level
WFMPRE:<wfm>:YMULT?Query Vertical Scale For Source. Returns the vertical scale factor of the given waveform.Text: CH<x>, MATH<x>, or REF<x>
WFMPRE:<wfm>:YOFF <offset>Set Vertical Position For Source. Sets the vertical position of the given waveform.Number: position in digitizing levels
WFMPRE:<wfm>:YOFF?Query Vertical Position For Source. Returns the vertical position of the given waveform.Text: CH<x>, MATH<x>, or REF<x>
WFMPRE:<wfm>:YUNIT?Query Vertical Units. Returns the vertical units of the given waveform (volts).Text: CH<x>, MATH<x>, or REF<x>
WFMPRE:<wfm>:YZERO <offset>Set Vertical Offset Voltage For Source. Sets the vertical offset voltage of the given waveform.Number: offset in YUNits (usually volts)
WFMPRE:<wfm>:YZERO?Query Vertical Offset Voltage For Source. Returns the vertical offset voltage of the given waveform.Text: CH<x>, MATH<x>, or REF<x>

Trigger (TRIGger) (24)

CommandWhat it doesArguments
TRIGger FORCeForce Trigger. Forces a trigger event to occur.None
TRIGger?Query Trigger Parameters. Returns the current trigger parameters.None
TRIGger:MAIn:LEVel <level>Set Main Trigger Level. Sets the main trigger level.Number: trigger level in volts, or ECL (-1.3 V) or TTL (1.4 V) preset
TRIGger:MAIn:LEVel?Query Main Trigger Level. Returns the main trigger level.None
TRIGger:MAIn:EDGE:SLOpe <slope>Set Main Edge Trigger Slope. Selects the rising or falling slope for the main edge trigger.Text: RISe, FALL
TRIGger:MAIn:EDGE:SLOpe?Query Main Edge Trigger Slope. Returns the main edge trigger slope.None
TRIGger:MAIn:EDGE:COUPling <coupling>Set Main Edge Trigger Coupling. Sets the coupling for the main edge trigger.Text: AC, DC, HFRej, LFRej, NOISErej
TRIGger:MAIn:EDGE:COUPling?Query Main Edge Trigger Coupling. Returns the main edge trigger coupling.None
TRIGger:MAIn:EDGE:SOUrce <source>Set Main Edge Trigger Source. Sets the source for the main edge trigger.Text: CH1,CH2,CH3,CH4,LINE
TRIGger:MAIn:EDGE:SOUrce?Query Main Edge Trigger Source. Returns the main edge trigger source.None
TRIGger:MAIn:EDGE?Query Main Edge Trigger Settings. Returns the coupling, source and slope of the main edge trigger.None
TRIGger:MAIn:MODe <mode>Set Main Trigger Mode. Sets the main trigger mode.Text: NORMal, AUTO
TRIGger:MAIn:MODe?Query Main Trigger Mode. Returns the main trigger mode.None
TRIGger:MAIn:TYPe <type>Set Main Trigger Type. Sets the type of the main trigger.Text: EDGE,LOGIc,PULse,VIDeo
TRIGger:MAIn:TYPe?Query Main Trigger Type. Returns the type of the main trigger.None
TRIGger:MAIn:HOLDOff:TIMe <time>Set Main Holdoff Time. Sets the main trigger holdoff time.Number: holdoff time in seconds, 250 ns to 12.0 s (TDS 500C and 700C only)
TRIGger:MAIn:HOLDOff:TIMe?Query Main Holdoff Time. Returns the main trigger holdoff time.None
TRIGger:MAIn:HOLDOff:ACTUal?Query Actual Main Holdoff. Returns the actual main trigger holdoff value in seconds (TDS 500C, 600B and 700C only).None
TRIGger:DELay:LEVel <level>Set Delayed Trigger Level. Sets the delayed trigger level.Number: delayed trigger level in volts, or ECL (-1.3 V) or TTL (1.4 V) preset
TRIGger:DELay:LEVel?Query Delayed Trigger Level. Returns the delayed trigger level.None
TRIGger:DELay:TIMe <time>Set Delayed Trigger Time. Sets the delay time used when the delay is by time.Number: delay time in seconds
TRIGger:DELay:TIMe?Query Delayed Trigger Time. Returns the delayed trigger time.None
TRIGger:DELay:BY <mode>Set Delayed Trigger By. Selects whether the delayed trigger occurs after events or after a time period.Text: EVENTS, TIMe
TRIGger:DELay:BY?Query Delayed Trigger By. Returns how the delayed trigger is set to occur.None

CH subsystem (18)

CommandWhat it doesArguments
CH<channel>:SCALE <volts>Set Channel Scale. Sets the vertical gain of the specified channel.Number: channel 1 to 4; Number: volts per division, 1 mV to 10 V with a 1x probe
CH<channel>:SCALE?Query Channel Scale. Returns the vertical gain of the specified channel in volts per division.Number: channel 1 to 4
CH<channel>:OFFSET <volts>Set Channel Offset. Sets the voltage subtracted from the channel before acquisition.Number: channel 1 to 4; Number: offset in volts; range depends on scale and probe attenuation
CH<channel>:OFFSET?Query Channel Offset. Returns the channel offset in volts.Number: channel 1 to 4
CH<channel>:POSITION <divisions>Set Channel Position. Sets the vertical position of the channel.Number: channel 1 to 4; Number: -5 to 5 divisions from center graticule
CH<channel>:POSITION?Query Channel Position. Returns the vertical position of the channel in divisions.Number: channel 1 to 4
CH<channel>:COUPLING <coupling>Set Channel Coupling. Sets the input coupling of the channel.Number: channel 1 to 4; Text: AC, DC or GND
CH<channel>:COUPLING?Query Channel Coupling. Returns the input coupling of the channel.Number: channel 1 to 4
CH<channel>:IMPEDANCE <impedance>Set Channel Impedance. Sets the input impedance of the channel.Number: channel 1 to 4; Text: FIFty,MEG
CH<channel>:IMPEDANCE?Query Channel Impedance. Returns the input impedance of the channel.Number: channel 1 to 4
CH<channel>:BANDWIDTH <limit>Set Channel Bandwidth. Sets the bandwidth limit of the channel.Number: channel 1 to 4; Text: TWEnty,TWOfifty,FULl
CH<channel>:BANDWIDTH?Query Channel Bandwidth. Returns the bandwidth limit of the channel.Number: channel 1 to 4
CH<channel>:DESKEW <nanoseconds>Set Channel Deskew. Sets the deskew time that compensates for cable delay differences.Number: channel 1 to 4; Number: -25.0 to 25.0 ns, resolution 1 ps
CH<channel>:DESKEW?Query Channel Deskew. Returns the deskew time of the channel in nanoseconds.Number: channel 1 to 4
CH<channel>:PROBE?Query Probe Attenuation. Returns the attenuation factor of the probe attached to the channel.Number: channel 1 to 4
CH<channel>:PROBEFUNC:EXTATTEN?Query External Attenuation. Returns the external attenuation multiplier of the channel.Number: channel 1 to 4
CH<channel>:PROBEFUNC:EXTDBATTEN <dB>Set External Attenuation dB. Sets the external attenuation of the channel in dB.Number: channel 1 to 4; Number: -120.00 to 120.00 dB, default 0.00
CH<channel>:PROBEFUNC:EXTDBATTEN?Query External Attenuation dB. Returns the external attenuation of the channel in dB.Number: channel 1 to 4

ZOOM subsystem (13)

CommandWhat it doesArguments
ZOOM?Query Zoom Settings. Returns the current vertical and horizontal positioning and scaling of the display.None
ZOOM:HORIZONTAL:LOCK <target>Set Zoom Horizontal Lock. Sets which waveforms the horizontal zoom parameters affect.Text: ALL or LIVe
ZOOM:HORIZONTAL:LOCK?Query Zoom Horizontal Lock. Returns which waveforms the horizontal zoom parameters affect.None
ZOOM:HORIZONTAL:POSITION <position>Set Zoom Horizontal Position. Sets the horizontal position of zoomed waveforms.Number: 0 to 100 percent of waveform left of graticule
ZOOM:HORIZONTAL:POSITION?Query Zoom Horizontal Position. Returns the horizontal position of zoomed waveforms.None
ZOOM:HORIZONTAL:SCALE <factor>Set Zoom Horizontal Scale. Sets the horizontal zoom expansion factor.Number: expansion factor (less than 1 compresses, more than 1 expands)
ZOOM:HORIZONTAL:SCALE?Query Zoom Horizontal Scale. Returns the horizontal zoom expansion factor.None
ZOOM:STATE <state>Set Zoom State. Turns zoom mode off, on, or to preview.Text: OFF, ON, or PREVIEW
ZOOM:STATE?Query Zoom State. Returns OFF, PREVIEW, or ON for zoom mode.None
ZOOM:VERTICAL:POSITION <position>Set Zoom Vertical Position. Sets the vertical position of zoomed waveforms.Number: vertical position in divisions
ZOOM:VERTICAL:POSITION?Query Zoom Vertical Position. Returns the vertical position of zoomed waveforms.None
ZOOM:VERTICAL:SCALE <factor>Set Zoom Vertical Scale. Sets the vertical zoom expansion or compression factor.Number: vertical expansion or compression factor
ZOOM:VERTICAL:SCALE?Query Zoom Vertical Scale. Returns the vertical zoom expansion or compression factor.None

DAT subsystem (12)

CommandWhat it doesArguments
DATa:SOUrce <source>Set Waveform Source. Sets the waveform source transferred by CURVe?.Text: CH1, CH2, CH3, CH4, MATH1, MATH2, MATH3, REF1, REF2, REF3, REF4
DATa:SOUrce?Query Waveform Source. Returns the waveform source for transfers.None
DATa:STARt <point>Set Transfer Start Point. Sets the first data point transferred by CURVe?.Number: 1 to the record length
DATa:STARt?Query Transfer Start Point. Returns the first data point transferred.None
DATa:STOP <point>Set Transfer Stop Point. Sets the last data point transferred by CURVe?.Number: 1 to the record length
DATa:STOP?Query Transfer Stop Point. Returns the last data point transferred.None
DATa:ENCdg <format>Set Data Encoding. Sets the format of the waveform data transferred.Text: ASCIi,RIBinary,RPBinary,SRIbinary,SRPbinary
DATa:ENCdg?Query Data Encoding. Returns the waveform data format.None
DATa:WIDth <bytes>Set Data Width. Sets the number of bytes per data point for CURVe data.Number: 1 or 2 bytes per data point
DATa:WIDth?Query Data Width. Returns the number of bytes per data point.None
DATa:DESTination <ref>Set Data Destination. Sets the reference memory that receives CURVe data.Text: REF1, REF2, REF3, REF4
DATa:DESTination?Query Data Destination. Returns the reference memory location for incoming data.None

CURS subsystem (11)

CommandWhat it doesArguments
CURSor:FUNCtion <type>Set Cursor Function. Selects and displays the cursor type.Text: OFF, HBArs, VBArs, PAIred
CURSor:FUNCtion?Query Cursor Function. Returns the selected cursor type.None
CURSor?Query All Cursor Settings. Returns all current cursor settings.None
CURSor:VBArs:POSITION<x> <time>Set Vertical Bar Cursor Position. Positions a vertical bar cursor.Number: Cursor 1 or 2; Number: Time position in seconds relative to trigger
CURSor:VBArs:POSITION<x>?Query Vertical Bar Cursor Position. Returns the position of a vertical bar cursor.Number: Cursor 1 or 2
CURSor:VBArs:DELTa?Query Vertical Bar Cursor Delta. Returns the time between the two vertical bar cursors.None
CURSor:VBArs:SELect <cursor>Select Vertical Bar Cursor. Selects the active vertical bar cursor.Number: 1 or 2
CURSor:HBArs:POSITION<x> <volts>Set Horizontal Bar Cursor Position. Positions a horizontal bar cursor.Number: Cursor 1 or 2; Number: Voltage position relative to ground in volts
CURSor:HBArs:POSITION<x>?Query Horizontal Bar Cursor Position. Returns the position of a horizontal bar cursor.Number: Cursor 1 or 2
CURSor:HBArs:DELTa?Query Horizontal Bar Cursor Delta. Returns the voltage difference between the two horizontal bar cursors.None
CURSor:PAIred:VDELTA?Query Paired Cursor Time Delta. Returns the time distance between the paired cursors.None

TRIGGER subsystem (10)

CommandWhat it doesArguments
TRIGGER:MAIN:VIDEO:SOURCE <source>Set Video Trigger Source. Sets the source for the main video trigger (Option 05 only).Text: CH1, CH2, CH3, or CH4
TRIGGER:MAIN:VIDEO:SOURCE?Query Video Trigger Source. Returns the source for the main video trigger (Option 05 only).None
TRIGGER:MAIN:VIDEO:STANDARD <standard>Set Video Trigger Standard. Sets the video trigger standard (Option 05 only).Text: 525/NTSC, 625/PAL, HDTV, or FlexFmt
TRIGGER:MAIN:VIDEO:STANDARD?Query Video Trigger Standard. Returns the video trigger standard (Option 05 only).None
TRIGGER:MAIN:VIDEO:SYNC <polarity>Set Video Sync Polarity. Sets the video trigger sync polarity (Option 05 only).Text: NEGative or POSitive
TRIGGER:MAIN:VIDEO:SYNC?Query Video Sync Polarity. Returns the video trigger sync polarity (Option 05 only).None
TRIGGER:MAIN:VIDEO:SYSTEM?Query Video Trigger Class. Returns the video trigger class (Option 05 only).None
TRIGGER:MAIN:VIDEO:TIME <time>Set Video Delay Time. Sets the video trigger delay time (Option 05 only).Number: delay time in seconds
TRIGGER:MAIN:VIDEO:TIME?Query Video Delay Time. Returns the video trigger delay time (Option 05 only).None
TRIGGER:STATE?Query Trigger State. Returns the current state of the triggering system (for example ARMED, READY, TRIGGER, AUTO, SAVE).None

HOR subsystem (9)

CommandWhat it doesArguments
HORizontal:MAIn:SCAle <seconds>Set Main Time Per Division. Sets the time per division of the main time base.Number: 20 s to 1 ns per division, in a 1-2-5 sequence
HORizontal:MAIn:SCAle?Query Main Time Per Division. Returns the time per division of the main time base.None
HORizontal:POSition <percent>Set Horizontal Position. Positions the waveform horizontally on the display.Number: 0 to 100 percent
HORizontal:POSition?Query Horizontal Position. Returns the horizontal waveform position in percent.None
HORizontal:RECORDLength <points>Set Record Length. Sets the number of data points acquired per record.Number: Model-dependent record lengths, for example 500, 1000, 2500, 5000, 15000, 50000
HORizontal:RECORDLength?Query Record Length. Returns the number of data points per record.None
HORizontal:TRIGger:POSition <percent>Set Trigger Position. Sets the trigger position within the waveform.Number: 0 to 100 percent of pretrigger information
HORizontal:TRIGger:POSition?Query Trigger Position. Returns the trigger position in percent.None
HORizontal?Query Horizontal Settings. Returns all horizontal settings.None

ACQUIRE subsystem (9)

CommandWhat it doesArguments
ACQUIRE:STATE <state>Set Acquisition State. Starts or stops waveform acquisition.Text: ON or RUN starts acquisition; OFF or STOP stops it; a number where 0 stops and nonzero starts
ACQUIRE:STATE?Query Acquisition State. Returns whether acquisition is running.None
ACQUIRE:MODE <mode>Set Acquisition Mode. Sets how the displayed value is derived from acquisition samples.Text: SAMPLE, PEAKDETECT, HIRES, AVERAGE or ENVELOPE
ACQUIRE:MODE?Query Acquisition Mode. Returns the current acquisition mode.None
ACQUIRE:NUMAVG <count>Set Number of Averages. Sets the number of acquisitions combined in an averaged waveform.Number: 2 to 10000
ACQUIRE:NUMAVG?Query Number of Averages. Returns the number of acquisitions used for averaging.None
ACQUIRE:NUMENV <count>Set Number of Envelopes. Sets the number of acquisitions combined in an envelope waveform.Number: 0 (continuous enveloping) to 2000
ACQUIRE:NUMENV?Query Number of Envelopes. Returns the number of acquisitions used for enveloping.None
ACQUIRE:NUMACQ?Query Number of Acquisitions. Returns the number of acquisitions since acquisition started.None

MATH subsystem (5)

CommandWhat it doesArguments
MATH<x>?Query Math Definition. Returns the definition for the math waveform.None
MATH<x>:PROCessing <state>Set Math Averaging. Turns waveform averaging on or off for the math waveform.Text: ON, OFF or 1, 0
MATH<x>:PROCessing?Query Math Averaging. Returns whether math averaging is on.None
MATH<x>:NUMAVg <count>Set Math Average Count. Sets the number of times the math waveform is successively averaged.Number: number of successive averages before an acquisition completes
MATH<x>:NUMAVg?Query Math Average Count. Returns the math averaging count.None

SEL subsystem (4)

CommandWhat it doesArguments
SELect:<wfm> <state>Select Waveform Display. Turns a waveform display on or off and selects it.Text: CH1 to CH4, MATH1 to MATH3, REF1 to REF4; Number: 1 or ON turns the display on and selects it; 0 or OFF turns it off
SELect?Query Selected Waveform. Returns the selected waveform and the display status of all waveforms.None
SELect:CONTROl <wfm>Set Control Waveform. Sets the waveform affected by the cursor and vertical commands.Text: CH1 to CH4, MATH1 to MATH3, REF1 to REF4
SELect:CONTROl?Query Control Waveform. Returns the waveform currently affected by cursor and vertical commands.None

LIM subsystem (4)

CommandWhat it doesArguments
LIMit:STATE <state>Set Limit Test State. Turns limit testing on or off.Text: ON or OFF
LIMit:STATE?Query Limit Test State. Returns whether limit testing is in effect.None
LIMit:COMPARE:CH<x> <template>Set Limit Template For Channel. Sets the reference template used for limit testing of a channel.Number: Channel 1 to 4; Text: REF1, REF2, REF3, REF4, or no template
LIMit:COMPARE:CH<x>?Query Limit Template For Channel. Returns the limit test template for a channel.Number: Channel 1 to 4

DESE subsystem (3)

CommandWhat it doesArguments
DESE <value>Set Device Event Status Enable. Sets the Device Event Status Enable Register (DESER) bits.Number: 0 to 255
DESE?Query Device Event Status Enable. Returns the Device Event Status Enable Register contents.None
DESE <mask>Set Device Event Status Enable (DESE). Sets the bits of the Device Event Status Enable Register.Number: 0 to 255

CURV subsystem (2)

CommandWhat it doesArguments
CURVe?Transfer Waveform Data To Controller. Transfers the waveform data of the selected source to the controller.None
CURVe <data>Transfer Waveform Data To Oscilloscope. Transfers waveform data into the reference memory set by DATa:DESTination.Text: Binary or ASCII waveform block data

WAVFRM subsystem (1)

CommandWhat it doesArguments
WAVFRM?Query Waveform Data. Returns WFMPRE? and CURVE? data for the waveform selected by DATA:SOURCE.None

ZOO subsystem (1)

CommandWhat it doesArguments
ZOOm <mode>Reset Zoom. Resets the zoom transforms to default values.Text: RESET,RESETLive

BUSY subsystem (1)

CommandWhat it doesArguments
BUSY?Query Busy State. Returns whether the instrument is busy processing an extended-time command.None

EVENT subsystem (1)

CommandWhat it doesArguments
EVENT?Query Event Number. Reads and removes the next event code from the Event Queue (read *ESR? first).None

EVMSG subsystem (1)

CommandWhat it doesArguments
EVMSG?Query Event Message. Reads and removes the next event with its text description from the Event Queue.None

ALLEV subsystem (1)

CommandWhat it doesArguments
ALLEV?Query All Events. Returns all event numbers and descriptions in the Event Queue and clears them.None

FAC subsystem (1)

CommandWhat it doesArguments
FACtoryReset To Factory. Resets the oscilloscope to its factory default settings.None

EVQ subsystem (1)

CommandWhat it doesArguments
EVQty?Query Event Queue Count. Returns the number of event codes in the event queue.None

AUTOSET subsystem (1)

CommandWhat it doesArguments
AUTOSETAutoset. Adjusts vertical, horizontal and trigger controls to stabilize the displayed waveform.None

IEEE 488.2 common commands (17)

CommandWhat it doesArguments
*TRGExecute Group Trigger. Executes the commands defined by *DDT.None
*TST?Self Test Query. Tests the GPIB interface and returns 0.None
*WAIWait To Continue. Prevents further commands until all pending operations finish.None
*ESR?Query Standard Event Status Register. Returns the Standard Event Status Register contents and clears it.None
*ESE <value>Set Event Status Enable. Sets the Event Status Enable Register (ESER) bits.Number: 0 to 255
*ESE?Query Event Status Enable. Returns the Event Status Enable Register contents.None
*SRE <value>Set Service Request Enable. Sets the Service Request Enable Register (SRER) bits.Number: 0 to 255
*SRE?Query Service Request Enable. Returns the Service Request Enable Register contents.None
*STB?Query Status Byte. Returns the Status Byte Register contents (MSS bit in bit 6).None
*OPCSet Operation Complete. Sets the OPC bit in the SESR when pending operations complete.None
*OPC?Query Operation Complete. Returns 1 to the output queue once pending operations complete.None
*PSC <flag>Set Power-On Status Clear. Sets whether enable registers are reset at power on (1) or kept (0).Number: 0 or 1
*RSTReset Instrument. Returns the instrument to its factory default settings.None
*OPT?Query Options. Returns the list of options installed in the oscilloscope.None
*IDN?Identify. Returns the instrument identification string.None
*CLSClear Status. Clears the event queue and the status registers.None
*ESE <mask>Set Event Status Enable (*ESE). Sets the bits of the Event Status Enable Register.Number: 0 to 255

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Tektronix's programming documentation for the TDS724A and checked when the agent runs it. The library marks this instrument as supporting *OPC? for operation-complete synchronisation. Ranges, timing, and option-dependent commands are defined by Tektronix's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Tektronix TDS724A support SCPI remote control?

Yes. The Tektronix TDS724A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 237 SCPI commands for it: 133 queries that read values or state, and 104 settings and actions.

How do I control the Tektronix TDS724A from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, AUTOSET and MEASUrement:REFLevel:PERCent:HIGH?.

Which command reads a value from the Tektronix TDS724A?

MEASUrement:REFLevel:PERCent:HIGH? (query percent high reference). Returns the percent high reference level. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Tektronix TDS724A without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Tektronix TDS724A through the TestFlow desktop app, and writes the report from the measured results.