Frequency Counter · SCPI command reference

Tektronix FCA3000 and FCA3100 SCPI commands

The Tektronix FCA3000 and FCA3100 frequency counter is controlled remotely with SCPI commands. TestFlow's instrument library holds 46 commands for it, 17 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the FCA3000 on a real bench.

Commands
46
Queries
17
Subsystems
8
Models covered
2

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Tektronix FCA3000 or FCA3100 and writes the report from the measured results.

Get started

Control the Tektronix FCA3000 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Tektronix FCA3000's VISA address

# Paste the address of your Tektronix FCA3000 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("INPut1:COUPling AC")  # Set Input Coupling
print(inst.query("FORMat?"))  # Read Format

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Tektronix FCA3000 or FCA3100 and writes the report from the measured results.

Get started

Run a FCA3000 test without writing code

Describe the test in a sentence, for example “set input coupling on the FCA3000, then read format and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

46 commands in 8 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values. The FCA3000 and FCA3100 share this command set in TestFlow's library.

INP subsystem (22)

CommandWhat it doesArguments
INPut<Ch>:COUPling <Mode>Set Input Coupling. Sets input coupling mode.Number: 1,2; Text: AC,DC
INPut<Ch>:COUPling?Read Input Coupling. Reads input coupling mode.Number: 1,2
INPut<Ch>:FILTer ONAnalog Filter On. Enables analog input filter.Number: 1,2
INPut<Ch>:FILTer OFFAnalog Filter Off. Disables analog input filter.Number: 1,2
INPut<Ch>:FILTer?Read Analog Filter. Reads analog filter state.Number: 1,2
INPut<Ch>:FILTer:DIGital ONDigital Filter On. Enables digital filter.Number: 1,2
INPut<Ch>:FILTer:DIGital OFFDigital Filter Off. Disables digital filter.Number: 1,2
INPut<Ch>:FILTer:DIGital?Read Digital Filter. Reads digital filter state.Number: 1,2
INPut<Ch>:FILTer:DIGital:FREQuency <Hz>Set Digital Filter Frequency. Sets digital filter cutoff frequency.Number: 1,2; Number
INPut<Ch>:FILTer:DIGital:FREQuency?Read Digital Filter Frequency. Reads digital filter frequency.Number: 1,2
INPut<Ch>:FILTer:DIGital:FREQuency MINSet Digital Filter Frequency MIN. Sets digital filter to minimum frequency.Number: 1,2
INPut<Ch>:FILTer:DIGital:FREQuency MAXSet Digital Filter Frequency MAX. Sets digital filter to maximum frequency.Number: 1,2
INPut<Ch>:IMPedance <Ohm>Set Input Impedance. Sets input impedance value.Number: 1,2; Number
INPut<Ch>:IMPedance?Read Input Impedance. Reads input impedance setting.Number: 1,2
INPut<Ch>:IMPedance MINSet Input Impedance MIN. Sets minimum input impedance.Number: 1,2
INPut<Ch>:IMPedance MAXSet Input Impedance MAX. Sets maximum input impedance.Number: 1,2
INPut<Ch>:LEVel <Volt>Set Trigger Level. Sets trigger threshold voltage.Number: 1,2; Number
INPut<Ch>:LEVel?Read Trigger Level. Reads trigger level.Number: 1,2
INPut<Ch>:LEVel:AUTO ONSet Trigger Level AUTO. Enables automatic trigger level.Number: 1,2
INPut<Ch>:LEVel:AUTO OFFSet Trigger Level AUTO OFF. Disables automatic trigger level.Number: 1,2
INPut<Ch>:LEVel:AUTO ONCESet Trigger Level AUTO ONCE. Performs one-time auto trigger adjustment.Number: 1,2
INPut<Ch>:LEVel:AUTO?Read Trigger Level AUTO. Reads auto trigger level state.Number: 1,2

FORM subsystem (9)

CommandWhat it doesArguments
FORMat <Fmt>Set Format. Sets data output format.Text: ASCii,REAL,PACKed
FORMat?Read Format. Reads current data format.None
FORMat:BORDer <Order>Set Byte Order. Sets byte order for binary data.Text: NORMal,SWAPped
FORMat:BORDer?Read Byte Order. Reads current byte order.None
FORMat:SMAX <N>Set Array Max. Sets maximum array size for data transfer.Number
FORMat:SMAX?Read Array Max. Reads maximum array size setting.None
FORMat:TINFormation ONTimeStamp On. Enables timestamp in output data.None
FORMat:TINFormation OFFTimeStamp Off. Disables timestamp in output data.None
FORMat:TINFormation?Read TimeStamp. Reads timestamp status.None

Calculate (CALCulate) (7)

CommandWhat it doesArguments
CALCulate:STATe ONCalculate On. Enables calculation engine.None
CALCulate:STATe OFFCalculate Off. Disables calculation engine.None
CALCulate:STATe?Read Calculate State. Reads calculation state.None
CALCulate:TOTalize:TYPE APLUSBTotalize PostProc Add. Sets totalizer to add inputs.None
CALCulate:TOTalize:TYPE AMINUSBTotalize PostProc Sub. Sets totalizer to subtract inputs.None
CALCulate:TOTalize:TYPE ADIVBTotalize PostProc Div. Sets totalizer to divide inputs.None
CALCulate:TOTalize:TYPE?Read Totalize PostProc. Reads current totalizer mode.None

Fetch (FETCh) (3)

CommandWhat it doesArguments
FETCh?Fetch Scalar. Reads latest scalar measurement value.None
FETCh:ARRay? <N>Fetch Array. Reads array data with specified length.Number
FETCh:ARRay? MAXFetch Array MAX. Reads maximum available array data.Text: MAX

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last mearurment to a variableText

IEEE 488.2 common commands (2)

CommandWhat it doesArguments
*IDN?Identify. Returns instrument identification string.None
*RSTReset. Resets generator to default settings.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Tektronix's programming documentation for the FCA3000 and FCA3100 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Tektronix's programming manual: check it before you rely on an edge case. Last updated November 12, 2026.

Frequently asked questions

Does the Tektronix FCA3000 support SCPI remote control?

Yes. The Tektronix FCA3000 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 46 SCPI commands for it: 17 queries that read values or state, and 29 settings and actions.

How do I control the Tektronix FCA3000 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, INPut1:COUPling AC and FORMat?.

Which command reads a value from the Tektronix FCA3000?

FORMat? (read format). Reads current data format. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Tektronix FCA3000 without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Tektronix FCA3000 through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.