Function Generator · SCPI command reference

Tektronix AFG3011C, AFG3021C, AFG3051C, AFG3101C, AFG31021, AFG31051, AFG31101, AFG31151, AFG31251, and AFG3251C SCPI commands

The Tektronix AFG3011C, AFG3021C, AFG3051C, AFG3101C, AFG31021, AFG31051, AFG31101, AFG31151, AFG31251, and AFG3251C function generator is controlled remotely with SCPI commands. TestFlow's instrument library holds 95 commands for it, 12 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the AFG3011C on a real bench.

Commands
95
Queries
12
Subsystems
9
Models covered
10

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Tektronix AFG3011C, AFG3021C, AFG3051C, AFG3101C, AFG31021, AFG31051, AFG31101, AFG31151, AFG31251, or AFG3251C and writes the report from the measured results.

Get started

Control the Tektronix AFG3011C from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Tektronix AFG3011C's VISA address

# Paste the address of your Tektronix AFG3011C (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("OUTPut1:STATe ON")  # Turn On Output CH1
print(inst.query("OUTPut1:STATe?"))  # Read Output State CH1

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Tektronix AFG3011C, AFG3021C, AFG3051C, AFG3101C, AFG31021, AFG31051, AFG31101, AFG31151, AFG31251, or AFG3251C and writes the report from the measured results.

Get started

Run a AFG3011C test without writing code

Describe the test in a sentence, for example “turn on output ch1 on the AFG3011C, then read output state ch1 and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

95 commands in 9 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values. The AFG3011C, AFG3021C, AFG3051C, AFG3101C, AFG31021, AFG31051, AFG31101, AFG31151, AFG31251, and AFG3251C share this command set in TestFlow's library.

Source (SOURce) (67)

CommandWhat it doesArguments
SOURce1:FUNCtion:SHAPe <Shape>Set Function CH1. Sets the output waveform shape for channel 1.Text: SINusoid,SQUare,PULSe,RAMP,PRNoise,DC,SINC,GAUSsian,LORentz,ERISe,EDECay,HAVersine,USER1,USER2,USER3,USER4,EMEMory,EFILe
SOURce1:FUNCtion:SHAPe?Read Function CH1. Reads the output waveform shape for channel 1.None
SOURce1:FREQuency:FIXed <Freq>Set Frequency CH1. Sets the output frequency in Hz for channel 1.Number
SOURce1:FREQuency:FIXed?Read Frequency CH1. Reads the output frequency for channel 1.None
SOURce1:FREQuency:MODE CWSet Frequency Mode CW CH1. Sets channel 1 frequency mode to continuous wave.None
SOURce1:FREQuency:MODE SWEepSet Frequency Mode Sweep CH1. Sets channel 1 frequency mode to sweep.None
SOURce1:FREQuency:STARt <Freq>Set Frequency Start CH1. Sets the sweep start frequency for channel 1.Number
SOURce1:FREQuency:STOP <Freq>Set Frequency Stop CH1. Sets the sweep stop frequency for channel 1.Number
SOURce1:FREQuency:CENTer <Freq>Set Frequency Center CH1. Sets the sweep center frequency for channel 1.Number
SOURce1:FREQuency:SPAN <Freq>Set Frequency Span CH1. Sets the sweep frequency span for channel 1.Number
SOURce1:PHASe:ADJust <Deg>Set Phase CH1. Sets the phase in degrees for channel 1.Number
SOURce1:PHASe:ADJust?Read Phase CH1. Reads the phase for channel 1.None
SOURce1:VOLTage:LEVel:IMMediate:AMPLitude <Amp>Set Amplitude CH1. Sets the output amplitude for channel 1.Number
SOURce1:VOLTage:LEVel:IMMediate:AMPLitude?Read Amplitude CH1. Reads the output amplitude for channel 1.None
SOURce1:VOLTage:LEVel:IMMediate:HIGH <Volt>Set Voltage High CH1. Sets the high voltage level for channel 1.Number
SOURce1:VOLTage:LEVel:IMMediate:LOW <Volt>Set Voltage Low CH1. Sets the low voltage level for channel 1.Number
SOURce1:VOLTage:LEVel:IMMediate:OFFSet <Volt>Set Voltage Offset CH1. Sets the DC offset voltage for channel 1.Number
SOURce1:VOLTage:LEVel:IMMediate:OFFSet?Read Voltage Offset CH1. Reads the DC offset voltage for channel 1.None
SOURce1:VOLTage:UNIT <Unit>Set Voltage Unit CH1. Sets the amplitude unit for channel 1.Text: VPP,VRMS,DBM
SOURce1:VOLTage:LIMit:HIGH <Volt>Set Voltage Limit High CH1. Sets the high output-voltage limit for channel 1.Number
SOURce1:VOLTage:LIMit:LOW <Volt>Set Voltage Limit Low CH1. Sets the low output-voltage limit for channel 1.Number
SOURce1:PULSe:WIDTh <Sec>Set Pulse Width CH1. Sets the pulse width in seconds for channel 1.Number
SOURce1:PULSe:DCYCle <Pct>Set Pulse Duty Cycle CH1. Sets the pulse duty cycle percentage for channel 1.Number
SOURce1:PULSe:PERiod <Sec>Set Pulse Period CH1. Sets the pulse period in seconds for channel 1.Number
SOURce1:PULSe:TRANsition:LEADing <Sec>Set Pulse Lead Edge CH1. Sets the pulse leading-edge time for channel 1.Number
SOURce1:PULSe:TRANsition:TRAiling <Sec>Set Pulse Trail Edge CH1. Sets the pulse trailing-edge time for channel 1.Number
SOURce1:PULSe:DELay <Sec>Set Pulse Delay CH1. Sets the pulse delay for channel 1.Number
SOURce1:FUNCtion:RAMP:SYMMetry <Pct>Set Ramp Symmetry CH1. Sets the ramp symmetry percentage for channel 1.Number
SOURce1:AM:STATe ONEnable AM CH1. Enables AM modulation on channel 1.None
SOURce1:AM:STATe OFFDisable AM CH1. Disables AM modulation on channel 1.None
SOURce1:AM:DEPTh <Pct>Set AM Deviation CH1. Sets the AM depth percentage for channel 1.Number
SOURce1:AM:SOURce <Src>Set AM Source CH1. Sets the AM modulation source for channel 1.Text: INTernal,EXTernal
SOURce1:AM:INTernal:FREQuency <Freq>Set AM Int Freq CH1. Sets the internal AM modulating frequency for channel 1.Number
SOURce1:AM:INTernal:FUNCtion <Shape>Set AM Int Function CH1. Sets the internal AM modulating waveform for channel 1.Text: SINusoid,SQUare,TRIangle,RAMP,NRAMp,PRNoise
SOURce1:FM:STATe ONEnable FM CH1. Enables FM modulation on channel 1.None
SOURce1:FM:STATe OFFDisable FM CH1. Disables FM modulation on channel 1.None
SOURce1:FM:DEViation <Freq>Set FM Deviation CH1. Sets the FM frequency deviation in Hz for channel 1.Number
SOURce1:FM:SOURce <Src>Set FM Source CH1. Sets the FM modulation source for channel 1.Text: INTernal,EXTernal
SOURce1:FM:INTernal:FREQuency <Freq>Set FM Int Freq CH1. Sets the internal FM modulating frequency for channel 1.Number
SOURce1:FM:INTernal:FUNCtion <Shape>Set FM Int Function CH1. Sets the internal FM modulating waveform for channel 1.Text: SINusoid,SQUare,TRIangle,RAMP,NRAMp,PRNoise
SOURce1:PM:STATe ONEnable PM CH1. Enables PM modulation on channel 1.None
SOURce1:PM:STATe OFFDisable PM CH1. Disables PM modulation on channel 1.None
SOURce1:PM:DEViation <Deg>Set PM Deviation CH1. Sets the PM phase deviation in degrees for channel 1.Number
SOURce1:PM:SOURce <Src>Set PM Source CH1. Sets the PM modulation source for channel 1.Text: INTernal,EXTernal
SOURce1:PM:INTernal:FREQuency <Freq>Set PM Int Freq CH1. Sets the internal PM modulating frequency for channel 1.Number
SOURce1:PM:INTernal:FUNCtion <Shape>Set PM Int Function CH1. Sets the internal PM modulating waveform for channel 1.Text: SINusoid,SQUare,TRIangle,RAMP,NRAMp,PRNoise
SOURce1:FSKey:STATe ONEnable FSK CH1. Enables FSK modulation on channel 1.None
SOURce1:FSKey:STATe OFFDisable FSK CH1. Disables FSK modulation on channel 1.None
SOURce1:FSKey:FREQuency <Freq>Set FSK Hop Freq CH1. Sets the FSK hop frequency for channel 1.Number
SOURce1:FSKey:INTernal:RATE <Rate>Set FSK Rate CH1. Sets the FSK internal rate for channel 1.Number
SOURce1:FSKey:SOURce <Src>Set FSK Source CH1. Sets the FSK source for channel 1.Text: INTernal,EXTernal
SOURce1:PWM:STATe ONEnable PWM CH1. Enables PWM on channel 1.None
SOURce1:PWM:STATe OFFDisable PWM CH1. Disables PWM on channel 1.None
SOURce1:PWM:DEViation:DCYCle <Pct>Set PWM Deviation CH1. Sets the PWM duty-cycle deviation for channel 1.Number
SOURce1:PWM:SOURce <Src>Set PWM Source CH1. Sets the PWM source for channel 1.Text: INTernal,EXTernal
SOURce1:SWEep:TIME <Sec>Set Sweep Time CH1. Sets the sweep time for channel 1.Number
SOURce1:SWEep:HTIMe <Sec>Set Sweep Hold Time CH1. Sets the sweep hold time for channel 1.Number
SOURce1:SWEep:RTIMe <Sec>Set Sweep Return Time CH1. Sets the sweep return time for channel 1.Number
SOURce1:SWEep:SPACing <Type>Set Sweep Spacing CH1. Sets the sweep spacing for channel 1.Text: LINear,LOGarithmic
SOURce1:SWEep:MODE <Mode>Set Sweep Mode CH1. Sets the sweep mode (auto/manual) for channel 1.Text: AUTO,MANual
SOURce1:BURSt:STATe ONEnable Burst CH1. Enables burst mode on channel 1.None
SOURce1:BURSt:STATe OFFDisable Burst CH1. Disables burst mode on channel 1.None
SOURce1:BURSt:MODE <Mode>Set Burst Mode CH1. Sets the burst mode for channel 1.Text: TRIGgered,GATed
SOURce1:BURSt:NCYCles <N>Set Burst Cycles CH1. Sets the number of cycles per burst for channel 1.Number
SOURce1:BURSt:TDELay <Sec>Set Burst Delay CH1. Sets the burst delay for channel 1.Number
SOURce:ROSCillator:SOURce INTernalSet Clock Internal. Uses the internal reference clock.None
SOURce:ROSCillator:SOURce EXTernalSet Clock External. Uses the external reference clock.None

Output (OUTPut) (7)

CommandWhat it doesArguments
OUTPut1:STATe ONTurn On Output CH1. Enables channel 1 output.None
OUTPut1:STATe OFFTurn Off Output CH1. Disables channel 1 output.None
OUTPut1:STATe?Read Output State CH1. Reads whether channel 1 output is on.None
OUTPut1:IMPedance <Ohm>Set Output Impedance CH1. Sets the channel 1 output load impedance in ohms (1 to 10k).Number
OUTPut1:IMPedance?Read Output Impedance CH1. Reads the channel 1 output load impedance.None
OUTPut1:POLarity NORMalSet Output Polarity Normal CH1. Sets channel 1 output polarity to normal.None
OUTPut1:POLarity INVertedSet Output Polarity Inverted CH1. Sets channel 1 output polarity to inverted.None

Trigger (TRIGger) (4)

CommandWhat it doesArguments
TRIGger:SEQuence:SOURce <Src>Set Trigger Source. Sets the trigger source.Text: TIMer,EXTernal
TRIGger:SEQuence:SLOPe <Slope>Set Trigger Slope. Sets the external trigger slope.Text: POSitive,NEGative
TRIGger:SEQuence:TIMer <Sec>Set Trigger Timer. Sets the internal trigger timer period.Number
TRIGger:SEQuence:IMMediateTrigger Now. Issues an immediate (manual) trigger.None

System (SYSTem) (3)

CommandWhat it doesArguments
SYSTem:ERRor?Read Error. Reads and clears the next error-queue entry.None
SYSTem:BEEPer:STATe ONEnable Beeper. Enables the beeper.None
SYSTem:BEEPer:STATe OFFDisable Beeper. Disables the beeper.None

Display (DISPlay) (1)

CommandWhat it doesArguments
DISPlay:BRIGhtness <Level>Enable Display. Sets the display brightness (0 to 1).Number

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (10)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*TST?Self Test. Runs the self-test and returns 0 for pass.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete.None
*TRGTrigger Bus. Generates a bus trigger.None
*SAV <Slot>Save State Slot. Stores the current state to a setup memory slot (0 to 4).Number
*RCL <Slot>Recall State Slot. Recalls a state from a setup memory slot (0 to 4).Number
*OPT?Read Options. Queries the installed options.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Tektronix's programming documentation for the AFG3011C, AFG3021C, AFG3051C, AFG3101C, AFG31021, AFG31051, AFG31101, AFG31151, AFG31251, and AFG3251C and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Tektronix's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Tektronix AFG3011C support SCPI remote control?

Yes. The Tektronix AFG3011C accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 95 SCPI commands for it: 12 queries that read values or state, and 83 settings and actions.

How do I control the Tektronix AFG3011C from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut1:STATe ON and OUTPut1:STATe?.

Which command reads a value from the Tektronix AFG3011C?

OUTPut1:STATe? (read output state ch1). Reads whether channel 1 output is on. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Tektronix AFG3011C without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Tektronix AFG3011C through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.