Oscilloscope · SCPI command reference

Tektronix MSO54B SCPI commands

The Tektronix MSO54B oscilloscope is controlled remotely with SCPI commands. TestFlow's instrument library holds 70 commands for it, 7 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the MSO54B on a real bench.

Commands
70
Queries
7
Subsystems
17
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Tektronix MSO54B and writes the report from the measured results.

Get started

Control the Tektronix MSO54B from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Tektronix MSO54B's VISA address

# Paste the address of your Tektronix MSO54B (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("ACQuire:STOPAfter RUNSTop ;STATE RUN ;:DISplay:PERSistence Auto")  # RUN
print(inst.query("Set?"))  # Get settings

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Tektronix MSO54B and writes the report from the measured results.

Get started

Run a MSO54B test without writing code

Describe the test in a sentence, for example “run on the MSO54B, then get settings and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

70 commands in 17 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

AFG subsystem (17)

CommandWhat it doesArguments
AFG:AMPLitude <Voltage>AFG Amplitude. Number
AFG:ARBitrary:SOUrce <Source_path>AFG source. Text
AFG:BURSt:CCOUnt <Cycles_count>AFG cycles count. Number
AFG:BURSt:TRIGgerAFG burst. None
AFG:FUNCtion <Function>AFG function. Text: SINE,SQUare,PULSe,RAMP,NOISe,DC,SINC,GAUSsian,LORENtz,ERISe,EDECAy,HAVERSINe,CARDIac,ARBitrary
AFG:FREQuency <Frequency>AFG frequency. Number
AFG:HIGHLevel <Voltage>AFG High LVL. Number
AFG:LOWLevel <Voltage>AFG Low LVL. Number
AFG:NOISEAdd:PERCent <Percentage> ; AFG:NOISEAdd:STATE ONAFG Noise. Number
AFG:NOISEAdd:STATE OFFAFG Noise off. None
AFG:OFFSet <Offset>AFG offset. Number
AFG:OUTPut:MODe <Cont/Burst>AFG mode. Text: CONTinuous,BURSt,OFF
AFG:OUTPut:STATE ONAFG turn On. None
AFG:OUTPut:STATE OFFAFG turn Off. None
AFG:PERIod <Seconds>AFG period. Number
AFG:PULse:WIDth <Width>AFG width. Number
AFG:RAMP:SYMmetry <Percentage>AFG symetry. Number: 10,20,30,40,50,60,70,80,90

DIS subsystem (8)

CommandWhat it doesArguments
DISplay:WAVEView1:CURSor:CURSOR1:MODe <Mode>Cursor mode. Text: INDEPENDENT,TRACK
DISplay:WAVEView1:CURSor:CURSOR1:VBArs:DELTa?Cursor dT. None
DISplay:WAVEView1:CH<Digital Channel>_DALL:STATE ONBits ON. Text: 1,2,3,4
DISplay:WAVEView1:CH<Digital Channel>_DALL:STATE OFFBits OFF. Text: 1,2,3,4
DISplay:GLObal:CH<Digital Channel>:STATE <State>D channel display. Text: 1,2,3,4; Text: ON,OFF
DISplay:WAVEView<WAVEView>:CH<Digital Channel>_D<Bit>:STATE ONWaveView display. Text: 1; Text: 1,2,3,4; Text: 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15
DISplay:WAVEView<WAVEView>:CH<Digital Channel>_D<Bit>:STATE OFFWaveView Hide. Text: 1; Text: 1,2,3,4; Text: 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15
DISplay:WAVEView<WAVEView>:CH<Digital Channel>_DALL:VERTical:POSition <Vertical_position>D Vertical position. Text: 1; Text: 1,2,3,4; Text: 5,4,3,2,1,0,-1,-2,-3,-4,-5

Trigger (TRIGger) (7)

CommandWhat it doesArguments
TRIGger:A:EDGE:SLOpe <Slope>Trigget slope. Text: RISe,FALL,EITHer
TRIGger:A:EDGE:COUPling <Coupling>Trigger coupling. Text: DC,HFRej,LFRej,NOISErej
TRIGger:A:LEVel:<Channel> <Volt>Trigger level. Text: CH1,CH2,CH3,CH4; Number
TRIGger:A:TYPe LOGIc ; TRIGger:A:LOGIc:FUNCtion <Condition>D trigger condition. Text: AND,OR,NANd,NOR
TRIGger:A:LOGIc:POLarity <Polarity>D trigger polarity. Text: POSitive,NEGative,EITher
TRIGger:A:MODe <Mode>D trigger mode. Text: NORMal,AUTO
TRIGger:A:LOGICPattern:CH<Digital Channel>_D<Bit> <State>D trigger pattern. Text: 1,2,3,4; Text: 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15; Text: HIGH,LOW,X

CURS subsystem (6)

CommandWhat it doesArguments
CURSor:SOUrce <Channel>Cursor channel. Text: CH1,CH2,CH3,CH4
CURSor:FUNCtion WAVEFORMCursers ON. None
CURSor:FUNCtion OFFCursers OFF. None
CURSor:DDT?Cursers dV/dT. None
CURSor:HBArs:DELTa?Cursor dV. None
CURSor:HBArs:POSITION<Position>?Cursor voltage. None

MEASU subsystem (5)

CommandWhat it doesArguments
MEASUrement:IMMed:SOUrce <Channel> ; MEASUrement:IMMed:TYPe <Measurement> ; MEASUrement:IMMed:VALue?Measurement. Text: CH1,CH2,CH3,CH4; Text: AMPLITUDE,BASE,FALLTIME,FREQUENCY,MAXIMUM,MEAN,MINIMUM,NDUTY,NOVERSHOOT,NWIDTH,PDUTY,PERIOD,PK2Pk,POVERSHOOT,PWIDTH,RISETIME,RMS,TOP
MEASUrement:IMMed:SOUrce <Channel> ; MEASUrement:IMMed:VALue?Measurement Channel. Text: CH1,CH2,CH3,CH4
MEASUrement:IMMed:TYPe <Measurement>Measurement Type. Text: AMPLITUDE,BASE,FALLTIME,FREQUENCY,MAXIMUM,MEAN,MINIMUM,NDUTY,NOVERSHOOT,NWIDTH,PDUTY,PERIOD,PK2Pk,POVERSHOOT,PWIDTH,RISETIME,RMS,TOP
MEASUrement:IMMed:VALue?Measure. None
MEASUrement:IMMed:DELay:EDGE1 <Edge> ; MEASUrement:IMMed:SOUrce1 <Source_1> ; MEASUrement:IMMed:SOUrce2 <Source_2> ; MEASUrement:IMMed:TYPe DELayMeasure delay. Text: FALL,RISe; Text: CH1,CH2,CH3,CH4; Text: CH1,CH2,CH3,CH4

CH subsystem (5)

CommandWhat it doesArguments
CH<Digital Channel>_D<Bit>:LABel:COLor <Color>Digital label color. Text: 1,2,3,4; Text: 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15; Text
CH<Digital Bit>:LABel:FONT:<Font> <State>Digital label font. Text; Text: BOLD,ITALic,UNDERline; Text: ON,OFF
CH<Digital Channel>_D<Bit>:LABel:FONT:SIZE <Size>Digital font size. Text: 1,2,3,4; Text: 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15; Number
CH<Digital Channel>_D<Bit>:LABel:FONT:TYPE "<FontName>"Digital font type. Text: 1,2,3,4; Text: 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15; Text: Arial,Helvetica,Courier,Courier New,Times New Roman
CH<Digital Channel>_D<Bit>:LABel:NAMe "<Label>"Digital label name. Text: 1,2,3,4; Text: 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15; Text

Acquisition (ACQuire) (4)

CommandWhat it doesArguments
ACQuire:STOPAfter SEQuence ;STATE RUNSingle seq. None
ACQuire:STOPAfter RUNSTop ;STATE RUN ;:DISplay:PERSistence AutoRUN. None
ACQuire:STOPAfter RUNSTop ;STATE Stop ;:DISplay:PERSistence AutoSTOP. None
ACQuire:STOPAfter RUNSTop ;STATE Stop ;:DISplay:PERSistence INFIniteINFInite. None

Other subsystem (4)

CommandWhat it doesArguments
<Channel>:LABel:NAMe <Text>Chan label. Text: CH1,CH2,CH3,CH4; Text
<Channel>:POSition <Position>Channel position. Text: CH1,CH2,CH3,CH4; Number
<Channel>:SCALE <Scale>Channel scale. Text: CH1,CH2,CH3,CH4; Number
<Output Variable>=<Equation>Math. Number; Text
CommandWhat it doesArguments
SEARCH:SEARCH<Search>:TRIGger:A:LOGIc:LOGICPattern:CH<Digital Bit> <State>Search pattern. Number; Text; Text: H,L,X
SEARCH:SEARCH<Search>:TRIGger:A:LOGIc:WHEn <Condition>Search condition. Number; Text: TRUe,FALSe,MOREThan,LESSThan,EQual,UNEQual
SEARCH:SEARCH<Search>:TRIGger:A:PULSEWidth:HIGHLimit <Width>Search puls width. Number; Number
SEARCH:SEARCH<Search>:TRIGger:A:TIMEOut:TIMe <Time>Search TIMEOUT. Number; Number

HORIZONTAL subsystem (2)

CommandWhat it doesArguments
HORIZONTAL:POSITION <Position>Time position. Number
HORIZONTAL:SCALE <Scale>Time scale. Number

SEL subsystem (2)

CommandWhat it doesArguments
SELect:<Channel> ONShow channel. Text: CH1,CH2,CH3,CH4
SELect:<Channel> OFFHide channel. Text: CH1,CH2,CH3,CH4

TRIGGER subsystem (1)

CommandWhat it doesArguments
TRIGGER:A:EDGE:SOURCE <Channel>Trigger channel. Text: CH1,CH2,CH3,CH4

Save (SAVE) (1)

CommandWhat it doesArguments
SAVe:IMAGe:INKSaver ON ; SAVe:IMAGe:FILEFormat PNG ; SAVe:IMAGe "imgx.png" ; wait(100) ; FILESystem:DELEte "imgx.png"Capture. None

S subsystem (1)

CommandWhat it doesArguments
Set?Get settings. None

DIGGRP subsystem (1)

CommandWhat it doesArguments
DIGGRP<Digital Channel>:D<Bit>:THReshold <Threshold>Digital Threshold. Text: 1,2,3,4; Text: 0,1,2,3,4,5,6,7; Number

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_namer>Save2Variable. Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Number

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Tektronix's programming documentation for the MSO54B and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Tektronix's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Tektronix MSO54B support SCPI remote control?

Yes. The Tektronix MSO54B accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 70 SCPI commands for it: 7 queries that read values or state, and 63 settings and actions.

How do I control the Tektronix MSO54B from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, ACQuire:STOPAfter RUNSTop ;STATE RUN ;:DISplay:PERSistence Auto and Set?.

Which command reads a value from the Tektronix MSO54B?

Set? (get settings). The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Tektronix MSO54B without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Tektronix MSO54B through the TestFlow desktop app, and writes the report from the measured results.