Power Supply · SCPI command reference

GW Instek GPP-4323 SCPI commands

The GW Instek GPP-4323 power supply is controlled remotely with SCPI commands. TestFlow's instrument library holds 30 commands for it, 9 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the GPP-4323 on a real bench.

Commands
30
Queries
9
Subsystems
8
Models covered
1

Control the GW Instek GPP-4323 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the GW Instek GPP-4323's VISA address

# Paste the address of your GW Instek GPP-4323 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write(":OUTPut1:STATe ON")  # Turn On CH1
print(inst.query(":MEASure1:VOLTage?"))  # Measure Voltage

inst.close()

Run a GPP-4323 test without writing code

Describe the test in a sentence, for example “turn on ch1 on the GPP-4323, then measure voltage and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

30 commands in 8 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Output (OUTPut) (11)

CommandWhat it doesArguments
:OUTPut1:STATe ONTurn On CH1. Enables the output of channel 1.None
:OUTPut1:STATe OFFTurn Off CH1. Disables the output of channel 1.None
:OUTPut2:STATe ONTurn On CH2. Enables the output of channel 2.None
:OUTPut2:STATe OFFTurn Off CH2. Disables the output of channel 2.None
:OUTPut3:STATe ONTurn On CH3. Enables the output of channel 3.None
:OUTPut3:STATe OFFTurn Off CH3. Disables the output of channel 3.None
:OUTPut4:STATe ONTurn On CH4. Enables the output of channel 4.None
:OUTPut4:STATe OFFTurn Off CH4. Disables the output of channel 4.None
:OUTPut<Channel>:OVP <Volt>Set OVP. Sets the over-voltage protection level of the selected channel.Number: 1,2,3,4; Number
:OUTPut<Channel>:OVP:STATe ONEnable OVP. Enables over-voltage protection on the selected channel.Number: 1,2,3,4
:OUTPut<Channel>:OVP:STATe OFFDisable OVP. Disables over-voltage protection on the selected channel.Number: 1,2,3,4

Source (SOURce) (4)

CommandWhat it doesArguments
:SOURce<Channel>:VOLTage <Volt>Set Voltage. Sets the output voltage of the selected channel in volts.Number: 1,2,3,4; Number
:SOURce<Channel>:VOLTage?Read Voltage Setting. Reads the set output voltage of the selected channel.Number: 1,2,3,4
:SOURce<Channel>:CURRent <Amp>Set Current. Sets the output current limit of the selected channel in amps.Number: 1,2,3,4; Number
:SOURce<Channel>:CURRent?Read Current Setting. Reads the set output current limit of the selected channel.Number: 1,2,3,4

Measurement (MEASure) (3)

CommandWhat it doesArguments
:MEASure<Channel>:VOLTage?Measure Voltage. Measures the output voltage of the selected channel in volts.Number: 1,2,3,4
:MEASure<Channel>:CURRent?Measure Current. Measures the output current of the selected channel in amps.Number: 1,2,3,4
:MEASure<Channel>:POWEr?Measure Power. Measures the output power of the selected channel in watts.Number: 1,2,3,4

System (SYSTem) (1)

CommandWhat it doesArguments
SYSTem:ERRor?Read Error. Reads the first message from the error queue.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (8)

CommandWhat it doesArguments
*SAV <Slot>Save State. Saves the current instrument state to the specified storage slot.Number
*RCL <Slot>Recall State. Recalls an instrument state from the specified storage slot.Number
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*TST?Self Test. Runs the self-test and returns 0 for pass or 1 for failure.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete before continuing.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from GW Instek's programming documentation for the GPP-4323 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by GW Instek's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the GW Instek GPP-4323 support SCPI remote control?

Yes. The GW Instek GPP-4323 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 30 SCPI commands for it: 9 queries that read values or state, and 21 settings and actions.

How do I control the GW Instek GPP-4323 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, :OUTPut1:STATe ON and :MEASure1:VOLTage?.

Which command reads a value from the GW Instek GPP-4323?

:MEASure1:VOLTage? (measure voltage). Measures the output voltage of the selected channel in volts. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the GW Instek GPP-4323 without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the GW Instek GPP-4323 through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.