The Fluke 8845A multimeter is controlled remotely with SCPI commands. TestFlow's instrument library holds 113 commands for it, 33 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the 8845A on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Fluke 8845A and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Fluke 8845A's VISA address
# Paste the address of your Fluke 8845A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("FUNCtion \"VOLTage:DC\"") # Func DCV
print(inst.query("MEASure:VOLTage:DC?")) # Measure DCV
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Fluke 8845A and writes the report from the measured results.
Describe the test in a sentence, for example “func dcv on the 8845A, then measure dcv and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
113 commands in 20 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| CALCulate:FUNCtion <Function> | Set Math Function. Selects the math operation applied to readings. | Text: NULL,DB,DBM,AVERage,LIMit |
| CALCulate:STATe ON | Math On. Enables the math (CALCulate) operation. | None |
| CALCulate:STATe OFF | Math Off. Disables the math (CALCulate) operation. | None |
| CALCulate:NULL:OFFSet <Offset> | Set Null Offset. Sets the null (relative) offset value subtracted from each reading. | Number |
| CALCulate:NULL:OFFSet? | Read Null Offset. Returns the present null (relative) offset value. | None |
| CALCulate:DB:REFerence <Reference> | Set dB Reference. Sets the dB relative reference value in dBm. | Number |
| CALCulate:DB:REFerence? | Read dB Reference. Returns the present dB reference value. | None |
| CALCulate:DBM:REFerence <Reference> | Set dBm Reference. Sets the dBm reference resistance in ohms used for the dBm computation. | Number: 2,4,6,16,50,75,90,93,100,110,124,125,135,150,250,300,500,600,800,900,1000,1200,8000 |
| CALCulate:DBM:REFerence? | Read dBm Reference. Returns the present dBm reference resistance in ohms. | None |
| CALCulate:AVERage:MINimum? | Read Stat Min. Returns the minimum value found since the statistics filter was enabled. | None |
| CALCulate:AVERage:MAXimum? | Read Stat Max. Returns the maximum value found since the statistics filter was enabled. | None |
| CALCulate:AVERage:AVERage? | Read Stat Average. Returns the average of all readings since the statistics filter was enabled. | None |
| CALCulate:AVERage:COUNt? | Read Stat Count. Returns the number of readings included in the statistics calculation. | None |
| CALCulate:LIMit:LOWer <Lower> | Set Limit Lower. Sets the lower limit for the limit-test (pass/fail) math operation. | Number |
| CALCulate:LIMit:UPPer <Upper> | Set Limit Upper. Sets the upper limit for the limit-test (pass/fail) math operation. | Number |
| Command | What it does | Arguments |
|---|---|---|
| VOLTage:DC:RANGe <Range> | Set DCV Range. Sets the manual DC voltage range in volts. | Number: 0.1,1,10,100,1000 |
| VOLTage:DC:RANGe? | Read DCV Range. Returns the present DC voltage range in volts. | None |
| VOLTage:DC:RANGe:AUTO ON | DCV Autorange On. Enables autoranging for DC voltage. | None |
| VOLTage:DC:RANGe:AUTO OFF | DCV Autorange Off. Disables autoranging for DC voltage. | None |
| VOLTage:AC:RANGe <Range> | Set ACV Range. Sets the manual AC voltage range in volts. | Number: 0.1,1,10,100,750 |
| VOLTage:AC:RANGe:AUTO ON | ACV Autorange On. Enables autoranging for AC voltage. | None |
| VOLTage:AC:RANGe:AUTO OFF | ACV Autorange Off. Disables autoranging for AC voltage. | None |
| VOLTage:DC:NPLC <NPLC> | Set DCV NPLC. Sets the integration time for DC voltage in number of power line cycles. | Number: 0.02,0.2,1,10,100 |
| VOLTage:DC:RESolution <Resolution> | Set DCV Resolution. Sets the measurement resolution for DC voltage (absolute value in volts). | Number |
| VOLTage:AC:BANDwidth <Bandwidth> | Set ACV Bandwidth. Sets the AC voltage filter low-frequency limit in Hz (3 Hz slow / 20 Hz medium / 200 Hz fast). | Number: 3,20,200 |
| VOLTage:DC:IMPedance:AUTO ON | DCV Input Z Auto On. Enables automatic input impedance (>10 GOhm on the 100 mV/1 V/10 V ranges) for DC voltage. | None |
| VOLTage:DC:IMPedance:AUTO OFF | DCV Input Z Auto Off. Disables automatic input impedance and fixes DC voltage input impedance at 10 MOhm. | None |
| VOLTage:DC:FILTer:DIGital:STATe ON | DCV Avg Filter On. Enables the digital averaging filter for DC voltage to reduce noise. | None |
| VOLTage:DC:FILTer:DIGital:STATe OFF | DCV Avg Filter Off. Disables the digital averaging filter for DC voltage. | None |
| Command | What it does | Arguments |
|---|---|---|
| CONFigure:VOLTage:DC | Config DCV. Configures the meter for DC voltage measurement using default range and resolution. | None |
| CONFigure:VOLTage:DC <Range>,<Resolution> | Config DCV Range. Configures DC voltage with the specified range and resolution. | Number: 0.1,1,10,100,1000; Number |
| CONFigure:VOLTage:AC | Config ACV. Configures the meter for AC voltage measurement using default range and resolution. | None |
| CONFigure:CURRent:DC | Config DCI. Configures the meter for DC current measurement using default range and resolution. | None |
| CONFigure:CURRent:AC | Config ACI. Configures the meter for AC current measurement using default range and resolution. | None |
| CONFigure:RESistance | Config 2W Resistance. Configures the meter for 2-wire resistance measurement. | None |
| CONFigure:FRESistance | Config 4W Resistance. Configures the meter for 4-wire resistance measurement. | None |
| CONFigure:FREQuency | Config Frequency. Configures the meter for frequency measurement. | None |
| CONFigure:PERiod | Config Period. Configures the meter for period measurement. | None |
| CONFigure:CONTinuity | Config Continuity. Configures the meter for continuity measurement. | None |
| CONFigure:DIODe | Config Diode. Configures the meter for diode test measurement. | None |
| CONFigure? | Read Config. Returns the present function and range configuration as a quoted string. | None |
| Command | What it does | Arguments |
|---|---|---|
| FUNCtion "VOLTage:DC" | Func DCV. Selects DC voltage as the active measurement function. | None |
| FUNCtion "VOLTage:AC" | Func ACV. Selects AC voltage as the active measurement function. | None |
| FUNCtion "CURRent:DC" | Func DCI. Selects DC current as the active measurement function. | None |
| FUNCtion "CURRent:AC" | Func ACI. Selects AC current as the active measurement function. | None |
| FUNCtion "RESistance" | Func 2W Resistance. Selects 2-wire resistance as the active measurement function. | None |
| FUNCtion "FRESistance" | Func 4W Resistance. Selects 4-wire resistance as the active measurement function. | None |
| FUNCtion "FREQuency" | Func Frequency. Selects frequency as the active measurement function. | None |
| FUNCtion "PERiod" | Func Period. Selects period as the active measurement function. | None |
| FUNCtion "CONTinuity" | Func Continuity. Selects continuity as the active measurement function. | None |
| FUNCtion "DIODe" | Func Diode. Selects diode test as the active measurement function. | None |
| FUNCtion? | Read Function. Queries the currently selected measurement function (returns quoted string such as "VOLT:DC"). | None |
| Command | What it does | Arguments |
|---|---|---|
| MEASure:VOLTage:DC? | Measure DCV. Configures DC voltage and returns one measured value in volts. | None |
| MEASure:VOLTage:DC? <Range>,<Resolution> | Measure DCV Range. Configures DC voltage with given range and resolution and returns one measured value in volts. | Number: 0.1,1,10,100,1000; Number |
| MEASure:VOLTage:AC? | Measure ACV. Configures AC voltage and returns one measured value in volts RMS. | None |
| MEASure:CURRent:DC? | Measure DCI. Configures DC current and returns one measured value in amps. | None |
| MEASure:CURRent:AC? | Measure ACI. Configures AC current and returns one measured value in amps RMS. | None |
| MEASure:RESistance? | Measure 2W Resistance. Configures 2-wire resistance and returns one measured value in ohms. | None |
| MEASure:FRESistance? | Measure 4W Resistance. Configures 4-wire resistance and returns one measured value in ohms. | None |
| MEASure:FREQuency? | Measure Frequency. Configures frequency and returns one measured value in Hz. | None |
| MEASure:PERiod? | Measure Period. Configures period and returns one measured value in seconds. | None |
| MEASure:CONTinuity? | Measure Continuity. Configures continuity and returns one measured resistance value in ohms. | None |
| MEASure:DIODe? | Measure Diode. Configures diode test and returns the forward voltage in volts. | None |
| Command | What it does | Arguments |
|---|---|---|
| CURRent:DC:RANGe <Range> | Set DCI Range. Sets the manual DC current range in amps. | Number: 0.0001,0.001,0.01,0.1,1,3,10 |
| CURRent:DC:RANGe:AUTO ON | DCI Autorange On. Enables autoranging for DC current. | None |
| CURRent:DC:RANGe:AUTO OFF | DCI Autorange Off. Disables autoranging for DC current. | None |
| CURRent:AC:RANGe <Range> | Set ACI Range. Sets the manual AC current range in amps. | Number: 0.1,1,3,10 |
| CURRent:AC:RANGe:AUTO ON | ACI Autorange On. Enables autoranging for AC current. | None |
| CURRent:AC:RANGe:AUTO OFF | ACI Autorange Off. Disables autoranging for AC current. | None |
| CURRent:DC:NPLC <NPLC> | Set DCI NPLC. Sets the integration time for DC current in number of power line cycles. | Number: 0.02,0.2,1,10,100 |
| CURRent:AC:BANDwidth <Bandwidth> | Set ACI Bandwidth. Sets the AC current filter low-frequency limit in Hz (3 Hz slow / 20 Hz medium / 200 Hz fast). | Number: 3,20,200 |
| Command | What it does | Arguments |
|---|---|---|
| TRIGger:SOURce <Source> | Set Trigger Source. Sets the trigger source for the measurement. | Text: IMMediate,EXTernal,BUS |
| TRIGger:SOURce? | Read Trigger Source. Returns the present trigger source. | None |
| TRIGger:COUNt <Count> | Set Trigger Count. Sets the number of triggers the meter accepts before returning to idle (1 to 50000). | Number |
| TRIGger:COUNt? | Read Trigger Count. Returns the present trigger count. | None |
| TRIGger:DELay <Delay> | Set Trigger Delay. Sets the delay in seconds between the trigger and the start of the measurement. | Number |
| TRIGger:DELay? | Read Trigger Delay. Returns the present trigger delay in seconds. | None |
| TRIGger:DELay:AUTO ON | Trigger Delay Auto On. Enables automatic trigger delay based on function and range. | None |
| TRIGger:DELay:AUTO OFF | Trigger Delay Auto Off. Disables automatic trigger delay. | None |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:BEEPer:STATe ON | Beeper On. Enables the beeper. | None |
| SYSTem:BEEPer:STATe OFF | Beeper Off. Disables the beeper. | None |
| SYSTem:BEEPer | Beep. Issues a single beep. | None |
| SYSTem:ERRor? | Read Error. Reads and clears the oldest entry from the error queue (returns 0,"No error" if empty). | None |
| SYSTem:VERSion? | Read SCPI Version. Returns the SCPI version that the meter complies with. | None |
| SYSTem:LOCal | Local. Places the meter in local mode and enables the front-panel keys. | None |
| SYSTem:REMote | Remote. Places the meter in remote mode and disables the front-panel keys. | None |
| Command | What it does | Arguments |
|---|---|---|
| RESistance:RANGe <Range> | Set 2W Res Range. Sets the manual 2-wire resistance range in ohms. | Number: 100,1000,10000,100000,1000000,10000000,100000000,1000000000 |
| RESistance:RANGe:AUTO ON | Res 2W Autorange On. Enables autoranging for 2-wire resistance. | None |
| RESistance:RANGe:AUTO OFF | Res 2W Autorange Off. Disables autoranging for 2-wire resistance. | None |
| RESistance:NPLC <NPLC> | Set 2W Res NPLC. Sets the integration time for 2-wire resistance in number of power line cycles. | Number: 0.02,0.2,1,10,100 |
| Command | What it does | Arguments |
|---|---|---|
| FRESistance:RANGe <Range> | Set 4W Res Range. Sets the manual 4-wire resistance range in ohms. | Number: 100,1000,10000,100000,1000000,10000000,100000000,1000000000 |
| FRESistance:RANGe:AUTO ON | Res 4W Autorange On. Enables autoranging for 4-wire resistance. | None |
| FRESistance:RANGe:AUTO OFF | Res 4W Autorange Off. Disables autoranging for 4-wire resistance. | None |
| FRESistance:NPLC <NPLC> | Set 4W Res NPLC. Sets the integration time for 4-wire resistance in number of power line cycles. | Number: 0.02,0.2,1,10,100 |
| Command | What it does | Arguments |
|---|---|---|
| DISPlay ON | Display On. Turns the front-panel display on. | None |
| DISPlay OFF | Display Off. Turns the front-panel display off to speed up measurements. | None |
| DISPlay:TEXT <Message> | Set Display Text. Displays the specified text message on the front-panel display. | Text |
| DISPlay:TEXT:CLEar | Clear Display Text. Clears the text message from the front-panel display. | None |
| Command | What it does | Arguments |
|---|---|---|
| SAMPle:COUNt <Count> | Set Sample Count. Sets the number of samples taken per trigger (1 to 50000). | Number |
| SAMPle:COUNt? | Read Sample Count. Returns the present sample count per trigger. | None |
| Command | What it does | Arguments |
|---|---|---|
| READ? | Read Reading. Starts a new measurement and returns the reading using the current configuration. | None |
| Command | What it does | Arguments |
|---|---|---|
| FETCh? | Fetch Reading. Returns readings already stored in memory from the current trigger without starting a new measurement. | None |
| Command | What it does | Arguments |
|---|---|---|
| INITiate | Initiate. Changes the trigger state from idle to wait-for-trigger and stores readings in memory. | None |
| Command | What it does | Arguments |
|---|---|---|
| DATA:POINts? | Read Data Count. Returns the number of readings currently stored in reading memory. | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). | None |
| *RST | Reset. Resets the instrument to its default state. | None |
| *CLS | Clear Status. Clears all event registers and the error queue. | None |
| *TST? | Self Test. Runs the self-test and returns 0 for pass or 1 for failure. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *TRG | Trigger Bus. Generates a bus trigger when the trigger source is set to BUS. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Fluke's programming documentation for the 8845A and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Fluke's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The Fluke 8845A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 113 SCPI commands for it: 33 queries that read values or state, and 80 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, FUNCtion "VOLTage:DC" and MEASure:VOLTage:DC?.
MEASure:VOLTage:DC? (measure dcv). Configures DC voltage and returns one measured value in volts. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Fluke 8845A through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.