Multimeter · SCPI command reference

Fluke 8588A SCPI commands

The Fluke 8588A multimeter is controlled remotely with SCPI commands. TestFlow's instrument library holds 114 commands for it, 34 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the 8588A on a real bench.

Commands
114
Queries
34
Subsystems
20
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Fluke 8588A and writes the report from the measured results.

Get started

Control the Fluke 8588A from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Fluke 8588A's VISA address

# Paste the address of your Fluke 8588A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("FUNCtion \"VOLTage:DC\"")  # Func DCV
print(inst.query("MEASure:VOLTage:DC?"))  # Measure DCV

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Fluke 8588A and writes the report from the measured results.

Get started

Run a 8588A test without writing code

Describe the test in a sentence, for example “func dcv on the 8588A, then measure dcv and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

114 commands in 20 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Calculate (CALCulate) (15)

CommandWhat it doesArguments
CALCulate:FUNCtion <Function>Set Math Function. Selects the math operation applied to readings.Text: NULL,DB,DBM,AVERage,LIMit
CALCulate:MATH:STATe ONMath On. Enables the math (CALCulate) operation.None
CALCulate:MATH:STATe OFFMath Off. Disables the math (CALCulate) operation.None
CALCulate:MATH:CFACtor <Offset>Set Null Offset. Sets the null (relative) offset value subtracted from each reading.Number
CALCulate:MATH:CFACtor?Read Null Offset. Returns the present null (relative) offset value.None
CALCulate:DB:REFerence <Reference>Set dB Reference. Sets the dB relative reference value in dBm.Number
CALCulate:DB:REFerence?Read dB Reference. Returns the present dB reference value.None
CALCulate:DBM:REFerence <Reference>Set dBm Reference. Sets the dBm reference resistance in ohms used for the dBm computation.Number: 2,4,8,16,50,75,93,110,124,125,135,150,250,300,500,600,800,900,1000,1200,8000
CALCulate:DBM:REFerence?Read dBm Reference. Returns the present dBm reference resistance in ohms.None
CALCulate:SSTatistics:MINimum?Read Stat Min. Returns the minimum value found since the statistics filter was enabled.None
CALCulate:SSTatistics:MAXimum?Read Stat Max. Returns the maximum value found since the statistics filter was enabled.None
CALCulate:SSTatistics:AVERage?Read Stat Average. Returns the average of all readings since the statistics filter was enabled.None
CALCulate:SSTatistics:COUNt?Read Stat Count. Returns the number of readings included in the statistics calculation.None
CALCulate:LIMit:LOWer <Lower>Set Limit Lower. Sets the lower limit for the limit-test (pass/fail) math operation.Number
CALCulate:LIMit:UPPer <Upper>Set Limit Upper. Sets the upper limit for the limit-test (pass/fail) math operation.Number

Function (FUNCtion) (13)

CommandWhat it doesArguments
FUNCtion "VOLTage:DC"Func DCV. Selects DC voltage as the active measurement function.None
FUNCtion "VOLTage:AC"Func ACV. Selects AC voltage as the active measurement function.None
FUNCtion "CURRent:DC"Func DCI. Selects DC current as the active measurement function.None
FUNCtion "CURRent:AC"Func ACI. Selects AC current as the active measurement function.None
FUNCtion "RESistance"Func 2W Resistance. Selects 2-wire resistance as the active measurement function.None
FUNCtion "FRESistance"Func 4W Resistance. Selects 4-wire resistance as the active measurement function.None
FUNCtion "FREQuency"Func Frequency. Selects frequency as the active measurement function.None
FUNCtion "PERiod"Func Period. Selects period as the active measurement function.None
FUNCtion "CONTinuity"Func Continuity. Selects continuity as the active measurement function.None
FUNCtion "DIODe"Func Diode. Selects diode test as the active measurement function.None
FUNCtion "CAPacitance"Func Capacitance. Selects capacitance as the active measurement function (8846A only).None
FUNCtion "TEMPerature:RTD"Func Temperature. Selects temperature (RTD) as the active measurement function (8846A only).None
FUNCtion?Read Function. Queries the currently selected measurement function (returns quoted string such as "VOLT:DC").None

Measurement (MEASure) (12)

CommandWhat it doesArguments
MEASure:VOLTage:DC?Measure DCV. Configures DC voltage and returns one measured value in volts.None
MEASure:VOLTage:DC? <Range>,<Resolution>Measure DCV Range. Configures DC voltage with given range and resolution and returns one measured value in volts.Number: 0.1,1,10,100,1000; Number
MEASure:VOLTage:AC?Measure ACV. Configures AC voltage and returns one measured value in volts RMS.None
MEASure:CURRent:DC?Measure DCI. Configures DC current and returns one measured value in amps.None
MEASure:CURRent:AC?Measure ACI. Configures AC current and returns one measured value in amps RMS.None
MEASure:RESistance?Measure 2W Resistance. Configures 2-wire resistance and returns one measured value in ohms.None
MEASure:FRESistance?Measure 4W Resistance. Configures 4-wire resistance and returns one measured value in ohms.None
MEASure:FREQuency?Measure Frequency. Configures frequency and returns one measured value in Hz.None
MEASure:PERiod?Measure Period. Configures period and returns one measured value in seconds.None
MEASure:DIODe?Measure Diode. Configures diode test and returns the forward voltage in volts.None
MEASure:CAPacitance?Measure Capacitance. Configures capacitance and returns one measured value in farads (8846A only).None
MEASure:TEMPerature:RTD?Measure Temperature. Configures temperature and returns one measured value in degrees (8846A only).None

Voltage (VOLTage) (12)

CommandWhat it doesArguments
VOLTage:DC:RANGe <Range>Set DCV Range. Sets the manual DC voltage range in volts.Number: 0.1,1,10,100,1000
VOLTage:DC:RANGe?Read DCV Range. Returns the present DC voltage range in volts.None
VOLTage:DC:RANGe:AUTO ONDCV Autorange On. Enables autoranging for DC voltage.None
VOLTage:DC:RANGe:AUTO OFFDCV Autorange Off. Disables autoranging for DC voltage.None
VOLTage:AC:RANGe <Range>Set ACV Range. Sets the manual AC voltage range in volts.Number: 0.1,1,10,100,750
VOLTage:AC:RANGe:AUTO ONACV Autorange On. Enables autoranging for AC voltage.None
VOLTage:AC:RANGe:AUTO OFFACV Autorange Off. Disables autoranging for AC voltage.None
VOLTage:DC:NPLC <NPLC>Set DCV NPLC. Sets the integration time for DC voltage in number of power line cycles.Number: 0.02,0.2,1,10,100
VOLTage:DC:RESolution <Resolution>Set DCV Resolution. Sets the measurement resolution for DC voltage (absolute value in volts).Number
VOLTage:AC:FILTer <Bandwidth>Set ACV Bandwidth. Sets the AC voltage filter low-frequency limit in Hz (3 Hz slow / 20 Hz medium / 200 Hz fast).Number: 0.1,1,10,40,100,1000
VOLTage:DC:IMPedance AUTODCV Input Z Auto On. Enables automatic input impedance (>10 GOhm on the 100 mV/1 V/10 V ranges) for DC voltage.None
VOLTage:DC:IMPedance:AUTO OFFDCV Input Z Auto Off. Disables automatic input impedance and fixes DC voltage input impedance at 10 MOhm.None

Configure (CONFigure) (11)

CommandWhat it doesArguments
CONFigure:VOLTage:DCConfig DCV. Configures the meter for DC voltage measurement using default range and resolution.None
CONFigure:VOLTage:DC <Range>,<Resolution>Config DCV Range. Configures DC voltage with the specified range and resolution.Number: 0.1,1,10,100,1000; Number
CONFigure:VOLTage:ACConfig ACV. Configures the meter for AC voltage measurement using default range and resolution.None
CONFigure:CURRent:DCConfig DCI. Configures the meter for DC current measurement using default range and resolution.None
CONFigure:CURRent:ACConfig ACI. Configures the meter for AC current measurement using default range and resolution.None
CONFigure:RESistanceConfig 2W Resistance. Configures the meter for 2-wire resistance measurement.None
CONFigure:FRESistanceConfig 4W Resistance. Configures the meter for 4-wire resistance measurement.None
CONFigure:FREQuencyConfig Frequency. Configures the meter for frequency measurement.None
CONFigure:PERiodConfig Period. Configures the meter for period measurement.None
CONFigure:CAPacitanceConfig Capacitance. Configures the meter for capacitance measurement (8846A only).None
CONFigure?Read Config. Returns the present function and range configuration as a quoted string.None

Current (CURRent) (8)

CommandWhat it doesArguments
CURRent:DC:RANGe <Range>Set DCI Range. Sets the manual DC current range in amps.Number: 0.0001,0.001,0.01,0.1,1,3,10
CURRent:DC:RANGe:AUTO ONDCI Autorange On. Enables autoranging for DC current.None
CURRent:DC:RANGe:AUTO OFFDCI Autorange Off. Disables autoranging for DC current.None
CURRent:AC:RANGe <Range>Set ACI Range. Sets the manual AC current range in amps.Number: 0.1,1,3,10
CURRent:AC:RANGe:AUTO ONACI Autorange On. Enables autoranging for AC current.None
CURRent:AC:RANGe:AUTO OFFACI Autorange Off. Disables autoranging for AC current.None
CURRent:DC:NPLC <NPLC>Set DCI NPLC. Sets the integration time for DC current in number of power line cycles.Number: 0.02,0.2,1,10,100
CURRent:AC:FILTer <Bandwidth>Set ACI Bandwidth. Sets the AC current filter low-frequency limit in Hz (3 Hz slow / 20 Hz medium / 200 Hz fast).Number: 0.1,1,10,40,100,1000

Trigger (TRIGger) (8)

CommandWhat it doesArguments
TRIGger:SOURce <Source>Set Trigger Source. Sets the trigger source for the measurement.Text: IMMediate,EXTernal,BUS
TRIGger:SOURce?Read Trigger Source. Returns the present trigger source.None
TRIGger:COUNt <Count>Set Trigger Count. Sets the number of triggers the meter accepts before returning to idle (1 to 50000).Number
TRIGger:COUNt?Read Trigger Count. Returns the present trigger count.None
TRIGger:DELay <Delay>Set Trigger Delay. Sets the delay in seconds between the trigger and the start of the measurement.Number
TRIGger:DELay?Read Trigger Delay. Returns the present trigger delay in seconds.None
TRIGger:DELay:AUTO ONTrigger Delay Auto On. Enables automatic trigger delay based on function and range.None
TRIGger:DELay:AUTO OFFTrigger Delay Auto Off. Disables automatic trigger delay.None

System (SYSTem) (7)

CommandWhat it doesArguments
SYSTem:BEEPer:STATe ONBeeper On. Enables the beeper.None
SYSTem:BEEPer:STATe OFFBeeper Off. Disables the beeper.None
SYSTem:BEEPerBeep. Issues a single beep.None
SYSTem:ERRor?Read Error. Reads and clears the oldest entry from the error queue (returns 0,"No error" if empty).None
SYSTem:VERSion?Read SCPI Version. Returns the SCPI version that the meter complies with.None
SYSTem:LOCalLocal. Places the meter in local mode and enables the front-panel keys.None
SYSTem:REMoteRemote. Places the meter in remote mode and disables the front-panel keys.None

RES subsystem (4)

CommandWhat it doesArguments
RESistance:RANGe <Range>Set 2W Res Range. Sets the manual 2-wire resistance range in ohms.Number: 100,1000,10000,100000,1000000,10000000,100000000,1000000000
RESistance:RANGe:AUTO ONRes 2W Autorange On. Enables autoranging for 2-wire resistance.None
RESistance:RANGe:AUTO OFFRes 2W Autorange Off. Disables autoranging for 2-wire resistance.None
RESistance:NPLC <NPLC>Set 2W Res NPLC. Sets the integration time for 2-wire resistance in number of power line cycles.Number: 0.02,0.2,1,10,100

FRES subsystem (4)

CommandWhat it doesArguments
FRESistance:RANGe <Range>Set 4W Res Range. Sets the manual 4-wire resistance range in ohms.Number: 100,1000,10000,100000,1000000,10000000,100000000,1000000000
FRESistance:RANGe:AUTO ONRes 4W Autorange On. Enables autoranging for 4-wire resistance.None
FRESistance:RANGe:AUTO OFFRes 4W Autorange Off. Disables autoranging for 4-wire resistance.None
FRESistance:NPLC <NPLC>Set 4W Res NPLC. Sets the integration time for 4-wire resistance in number of power line cycles.Number: 0.02,0.2,1,10,100

Display (DISPlay) (4)

CommandWhat it doesArguments
DISPlay ONDisplay On. Turns the front-panel display on.None
DISPlay OFFDisplay Off. Turns the front-panel display off to speed up measurements.None
DISPlay:TEXT <Message>Set Display Text. Displays the specified text message on the front-panel display.Text
DISPlay:TEXT:CLEarClear Display Text. Clears the text message from the front-panel display.None

SAMP subsystem (2)

CommandWhat it doesArguments
SAMPle:COUNt <Count>Set Sample Count. Sets the number of samples taken per trigger (1 to 50000).Number
SAMPle:COUNt?Read Sample Count. Returns the present sample count per trigger.None

Read (READ) (1)

CommandWhat it doesArguments
READ?Read Reading. Starts a new measurement and returns the reading using the current configuration.None

Fetch (FETCh) (1)

CommandWhat it doesArguments
FETCh?Fetch Reading. Returns readings already stored in memory from the current trigger without starting a new measurement.None

Initiate (INITiate) (1)

CommandWhat it doesArguments
INITiateInitiate. Changes the trigger state from idle to wait-for-trigger and stores readings in memory.None

DATA subsystem (1)

CommandWhat it doesArguments
DATA:POINts?Read Data Count. Returns the number of readings currently stored in reading memory.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (7)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*TST?Self Test. Runs the self-test and returns 0 for pass or 1 for failure.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*TRGTrigger Bus. Generates a bus trigger when the trigger source is set to BUS.None
*WAIWait To Continue. Waits until all pending operations are complete before continuing.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Fluke's programming documentation for the 8588A and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Fluke's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Fluke 8588A support SCPI remote control?

Yes. The Fluke 8588A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 114 SCPI commands for it: 34 queries that read values or state, and 80 settings and actions.

How do I control the Fluke 8588A from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, FUNCtion "VOLTage:DC" and MEASure:VOLTage:DC?.

Which command reads a value from the Fluke 8588A?

MEASure:VOLTage:DC? (measure dcv). Configures DC voltage and returns one measured value in volts. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Fluke 8588A without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Fluke 8588A through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.