Oscilloscope · SCPI command reference

Teledyne LeCroy SDA 8080HD, SDA 8130, SDA 8160, SDA 8200, SDA 8300, and SDA8000HD SCPI commands

The Teledyne LeCroy SDA 8080HD, SDA 8130, SDA 8160, SDA 8200, SDA 8300, and SDA8000HD oscilloscope is controlled remotely with SCPI commands. TestFlow's instrument library holds 30 commands for it, 9 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the SDA 8080HD on a real bench.

Commands
30
Queries
9
Subsystems
15
Models covered
6

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Teledyne LeCroy SDA 8080HD, SDA 8130, SDA 8160, SDA 8200, SDA 8300, or SDA8000HD and writes the report from the measured results.

Get started

Control the Teledyne LeCroy SDA 8080HD from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Teledyne LeCroy SDA 8080HD's VISA address

# Paste the address of your Teledyne LeCroy SDA 8080HD (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("TRMD AUTO")  # Run Continuous
print(inst.query("TDIV?"))  # Read Timebase Scale

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Teledyne LeCroy SDA 8080HD, SDA 8130, SDA 8160, SDA 8200, SDA 8300, or SDA8000HD and writes the report from the measured results.

Get started

Run a SDA 8080HD test without writing code

Describe the test in a sentence, for example “run continuous on the SDA 8080HD, then read timebase scale and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

30 commands in 15 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values. The SDA 8080HD, SDA 8130, SDA 8160, SDA 8200, SDA 8300, and SDA8000HD share this command set in TestFlow's library.

C subsystem (9)

CommandWhat it doesArguments
C<n>:TRA ONChannel On. Enables channel display and acquisition.Number: 1,2,3,4,5,6,7,8
C<n>:TRA OFFChannel Off. Disables channel display and acquisition.Number: 1,2,3,4,5,6,7,8
C<n>:VDIV <VoltDiv>Channel Scale. Sets channel vertical scale (V/div).Number: 1,2,3,4,5,6,7,8; Number
C<n>:VDIV?Read Channel Scale. Reads channel vertical scale.Number: 1,2,3,4,5,6,7,8
C<n>:OFST <Volt>Channel Offset. Sets channel vertical offset (volts).Number: 1,2,3,4,5,6,7,8; Number
C<n>:OFST?Read Channel Offset. Reads channel vertical offset.Number: 1,2,3,4,5,6,7,8
C<n>:CPL <Mode>Channel Coupling. Sets channel input coupling mode.Number: 1,2,3,4,5,6,7,8; Text: A1M,D1M,D50,GND
C<n>:WF? DAT1Read Waveform Data. Reads raw waveform sample data.Number: 1,2,3,4,5,6,7,8
C<n>:WF? DESCRead Waveform Preamble. Reads waveform metadata and scaling info.Number: 1,2,3,4,5,6,7,8

TRMD subsystem (3)

CommandWhat it doesArguments
TRMD SINGLESingle Acquisition. Arms scope for one triggered acquisition.None
TRMD AUTORun Continuous. Starts continuous waveform acquisition.None
TRMD STOPStop Acquisition. Stops waveform acquisition.None

TDIV subsystem (2)

CommandWhat it doesArguments
TDIV <SecDiv>Timebase Scale. Sets horizontal time scale (seconds/div).Number
TDIV?Read Timebase Scale. Reads current timebase scale.None

TRDL subsystem (2)

CommandWhat it doesArguments
TRDL <Sec>Timebase Offset. Sets horizontal time offset.Number
TRDL?Read Timebase Offset. Reads current timebase offset.None

TRLV subsystem (2)

CommandWhat it doesArguments
TRLV <Volt>Trigger Level. Sets trigger voltage level.Number
TRLV?Read Trigger Level. Reads current trigger level.None

Other subsystem (2)

CommandWhat it doesArguments
<Source>:PAVA? <Type>Read Measurement. Reads measurement numeric value.Text: C1,C2,C3,C4,F1,F2,F3,F4; Text: AMPL,AREA,BASE,DLY,DUTY,FALL,FREQ,MAX,MEAN,MIN,OVSN,OVSP,PHASE,PKPK,PER,RISE,RMS,SDEV,TOP,WID,WIDN
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

ASET subsystem (1)

CommandWhat it doesArguments
ASETAuto Setup. Automatically configures scope for detected signals.None

TRSE subsystem (1)

CommandWhat it doesArguments
TRSE EDGE,SR,<Source>Trigger Source. Selects trigger source.Text: C1,C2,C3,C4,EX,LINE

TRSL subsystem (1)

CommandWhat it doesArguments
TRSL <Slope>Trigger Slope. Selects trigger edge polarity.Text: POS,NEG

PACU subsystem (1)

CommandWhat it doesArguments
PACU <n>,<Type>,<Source>Measurement. Defines a measurement type and source.Number: 1,2,3,4,5,6,7,8; Text: AMPL,AREA,BASE,DLY,DUTY,FALL,FREQ,MAX,MEAN,MIN,OVSN,OVSP,PHASE,PKPK,PER,RISE,RMS,SDEV,TOP,WID,WIDN; Text: C1,C2,C3,C4,F1,F2,F3,F4

PADL subsystem (1)

CommandWhat it doesArguments
PADL <n>Clear Measurement. Clears measurement configuration.Number: 1,2,3,4,5,6,7,8

HCSU subsystem (1)

CommandWhat it doesArguments
HCSU DEV,PNG,FORMAT,LANDSCAPE,BCKG,WHITE,DEST,REMOTE,AREA,GRIDAREAONLYCapture. Captures and saves display image as PNG.None

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last mearurment to a variableText

IEEE 488.2 common commands (2)

CommandWhat it doesArguments
*IDN?Identify. Returns instrument identification string.None
*RSTReset. Resets instrument to default state.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Teledyne LeCroy's programming documentation for the SDA 8080HD, SDA 8130, SDA 8160, SDA 8200, SDA 8300, and SDA8000HD and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Teledyne LeCroy's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Teledyne LeCroy SDA 8080HD support SCPI remote control?

Yes. The Teledyne LeCroy SDA 8080HD accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 30 SCPI commands for it: 9 queries that read values or state, and 21 settings and actions.

How do I control the Teledyne LeCroy SDA 8080HD from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, TRMD AUTO and TDIV?.

Which command reads a value from the Teledyne LeCroy SDA 8080HD?

TDIV? (read timebase scale). Reads current timebase scale. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Teledyne LeCroy SDA 8080HD without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Teledyne LeCroy SDA 8080HD through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.