The Sorensen XG40-21 power supply is controlled remotely with SCPI commands. TestFlow's instrument library holds 26 commands for it, 10 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the XG40-21 on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Sorensen XG40-21 and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Sorensen XG40-21's VISA address
# Paste the address of your Sorensen XG40-21 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write(":OUTPut:STATe ON") # Turn On
print(inst.query(":MEASure:VOLTage?")) # Measure Voltage
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Sorensen XG40-21 and writes the report from the measured results.
Describe the test in a sentence, for example “turn on on the XG40-21, then measure voltage and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
26 commands in 8 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| :SOURce:VOLTage <Volt> | Set Voltage. Sets the output voltage in volts. | Number |
| :SOURce:VOLTage? | Read Voltage Setting. Reads the programmed output voltage. | None |
| :SOURce:CURRent <Amp> | Set Current. Sets the output current limit in amps. | Number |
| :SOURce:CURRent? | Read Current Setting. Reads the programmed output current limit. | None |
| :SOURce:VOLTage:PROTection <Volt> | Set OVP. Sets the over-voltage protection trip level in volts. | Number |
| :SOURce:VOLTage:PROTection? | Read OVP. Reads the over-voltage protection trip level. | None |
| Command | What it does | Arguments |
|---|---|---|
| :OUTPut:STATe ON | Turn On. Enables the power supply output. | None |
| :OUTPut:STATe OFF | Turn Off. Disables the power supply output. | None |
| :OUTPut:STATe? | Read Output State. Reads whether the output is ON or OFF. | None |
| :OUTPut:PROTection:FOLDback <Mode> | Set Foldback. Sets foldback mode: 0 off, 1 trip on CV, 2 trip on CC. | Text: CC,CV,NONE |
| :OUTPut:PROTection:CLEar | Clear Protection. Clears a latched protection (OVP/OCP/foldback) trip. | None |
| Command | What it does | Arguments |
|---|---|---|
| :MEASure:VOLTage? | Measure Voltage. Measures the actual output voltage in volts. | None |
| :MEASure:CURRent? | Measure Current. Measures the actual output current in amps. | None |
| Command | What it does | Arguments |
|---|---|---|
| :SYSTem:ERRor? | Read Error. Reads the next message from the error queue. | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *SAV <Slot> | Save State. Saves the current instrument state to the specified storage slot. | Number |
| *RCL <Slot> | Recall State. Recalls an instrument state from the specified storage slot. | Number |
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). | None |
| *RST | Reset. Resets the instrument to its default state. | None |
| *CLS | Clear Status. Clears all event registers and the error queue. | None |
| *TST? | Self Test. Runs the self-test and returns 0 for pass or 1 for failure. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *WAI | Wait To Continue. Waits until all pending operations are complete before continuing. | None |
| *TRG | Trigger Bus. Generates a bus trigger when the instrument is in wait-for-trigger state. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Sorensen's programming documentation for the XG40-21 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Sorensen's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The Sorensen XG40-21 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 26 SCPI commands for it: 10 queries that read values or state, and 16 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, :OUTPut:STATe ON and :MEASure:VOLTage?.
:MEASure:VOLTage? (measure voltage). Measures the actual output voltage in volts. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Sorensen XG40-21 through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.