Power Supply · SCPI command reference

Siglent SPD1305X SCPI commands

The Siglent SPD1305X power supply is controlled remotely with SCPI commands. TestFlow's instrument library holds 21 commands for it, 9 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the SPD1305X on a real bench.

Commands
21
Queries
9
Subsystems
8
Models covered
1

Control the Siglent SPD1305X from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Siglent SPD1305X's VISA address

# Paste the address of your Siglent SPD1305X (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("OUTPut CH1,ON")  # Turn On CH1
print(inst.query("MEASure:VOLTage? CH1"))  # Measure Voltage

inst.close()

Run a SPD1305X test without writing code

Describe the test in a sentence, for example “turn on ch1 on the SPD1305X, then measure voltage and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

21 commands in 8 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

CH subsystem (4)

CommandWhat it doesArguments
CH<Channel>:VOLTage <Volt>Set Voltage. Sets the output voltage of the selected channel in volts.Number: 1; Number
CH<Channel>:VOLTage?Read Voltage Setting. Reads the set output voltage of the selected channel.Number: 1
CH<Channel>:CURRent <Amp>Set Current. Sets the output current limit of the selected channel in amps.Number: 1; Number
CH<Channel>:CURRent?Read Current Setting. Reads the set output current limit of the selected channel.Number: 1

Measurement (MEASure) (3)

CommandWhat it doesArguments
MEASure:VOLTage? CH<Channel>Measure Voltage. Measures the output voltage of the selected channel in volts.Number: 1
MEASure:CURRent? CH<Channel>Measure Current. Measures the output current of the selected channel in amps.Number: 1
MEASure:POWer? CH<Channel>Measure Power. Measures the output power of the selected channel in watts.Number: 1

Output (OUTPut) (2)

CommandWhat it doesArguments
OUTPut CH1,ONTurn On CH1. Enables the output of channel 1.None
OUTPut CH1,OFFTurn Off CH1. Disables the output of channel 1.None

System (SYSTem) (1)

CommandWhat it doesArguments
SYSTem:ERRor?Read Error. Reads the first message from the error queue.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (8)

CommandWhat it doesArguments
*SAV <Slot>Save State. Saves the current instrument state to the specified storage slot.Number
*RCL <Slot>Recall State. Recalls an instrument state from the specified storage slot.Number
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*TST?Self Test. Runs the self-test and returns 0 for pass or 1 for failure.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete before continuing.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Siglent's programming documentation for the SPD1305X and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Siglent's programming manual: check it before you rely on an edge case. Last updated June 18, 2026.

Frequently asked questions

Does the Siglent SPD1305X support SCPI remote control?

Yes. The Siglent SPD1305X accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 21 SCPI commands for it: 9 queries that read values or state, and 12 settings and actions.

How do I control the Siglent SPD1305X from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut CH1,ON and MEASure:VOLTage? CH1.

Which command reads a value from the Siglent SPD1305X?

MEASure:VOLTage? CH1 (measure voltage). Measures the output voltage of the selected channel in volts. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Siglent SPD1305X without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Siglent SPD1305X through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.