The Rigol DP711 and DP712 power supply is controlled remotely with SCPI commands. TestFlow's instrument library holds 25 commands for it, 9 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the DP711 on a real bench.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Rigol DP711's VISA address
# Paste the address of your Rigol DP711 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write(":OUTPut ON") # Turn On
print(inst.query(":MEASure:VOLTage?")) # Measure Voltage
inst.close()Describe the test in a sentence, for example “turn on on the DP711, then measure voltage and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
25 commands in 8 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values. The DP711 and DP712 share this command set in TestFlow's library.
| Command | What it does | Arguments |
|---|---|---|
| :SOURce:VOLTage <Volt> | Set Voltage. Sets the output voltage in volts. | Number |
| :SOURce:VOLTage? | Read Voltage Setting. Reads the set output voltage. | None |
| :SOURce:CURRent <Amp> | Set Current. Sets the output current limit in amps. | Number |
| :SOURce:CURRent? | Read Current Setting. Reads the set output current limit. | None |
| :SOURce:VOLTage:PROTection <Volt> | Set OVP. Sets the over-voltage protection level in volts. | Number |
| :SOURce:VOLTage:PROTection:STATe ON | Enable OVP. Enables over-voltage protection. | None |
| :SOURce:VOLTage:PROTection:STATe OFF | Disable OVP. Disables over-voltage protection. | None |
| :SOURce:CURRent:PROTection <Amp> | Set OCP. Sets the over-current protection level in amps. | Number |
| :SOURce:CURRent:PROTection:STATe ON | Enable OCP. Enables over-current protection. | None |
| :SOURce:CURRent:PROTection:STATe OFF | Disable OCP. Disables over-current protection. | None |
| Command | What it does | Arguments |
|---|---|---|
| :OUTPut ON | Turn On. Enables the power supply output. | None |
| :OUTPut OFF | Turn Off. Disables the power supply output. | None |
| :OUTPut:STATe? | Read Output State. Reads whether the output is ON or OFF. | None |
| Command | What it does | Arguments |
|---|---|---|
| :MEASure:VOLTage? | Measure Voltage. Measures the output voltage in volts. | None |
| :MEASure:CURRent? | Measure Current. Measures the output current in amps. | None |
| :MEASure:POWer? | Measure Power. Measures the output power in watts. | None |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:ERRor? | Read Error. Reads the first message from the error queue. | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *SAV <Slot> | Save State. Saves the current instrument state to the specified storage slot. | Number |
| *RCL <Slot> | Recall State. Recalls an instrument state from the specified storage slot. | Number |
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). | None |
| *RST | Reset. Resets the instrument to its default state. | None |
| *TST? | Self Test. Runs the self-test and returns 0 for pass or 1 for failure. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Rigol's programming documentation for the DP711 and DP712 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Rigol's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The Rigol DP711 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 25 SCPI commands for it: 9 queries that read values or state, and 16 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, :OUTPut ON and :MEASure:VOLTage?.
:MEASure:VOLTage? (measure voltage). Measures the output voltage in volts. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Rigol DP711 through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.