The Rigol DS2072A oscilloscope is controlled remotely with SCPI commands. TestFlow's instrument library holds 154 commands for it, 48 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the DS2072A on a real bench.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Rigol DS2072A's VISA address
# Paste the address of your Rigol DS2072A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write(":AUToscale") # Auto Scale
print(inst.query(":MEASure:VPP? CHANnel1")) # Measure Vpp
inst.close()Describe the test in a sentence, for example “auto scale on the DS2072A, then measure vpp and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
154 commands in 20 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| :MEASure:SOURce <Source> | Measure Source. Sets the source of the automatic measurement parameters. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VPP <Source> | Enable Measure Vpp. Enables the peak-to-peak voltage measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VPP? <Source> | Measure Vpp. Queries the measured peak-to-peak voltage of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VMAX <Source> | Enable Measure Vmax. Enables the maximum voltage measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VMAX? <Source> | Measure Vmax. Queries the measured maximum voltage of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VMIN <Source> | Enable Measure Vmin. Enables the minimum voltage measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VMIN? <Source> | Measure Vmin. Queries the measured minimum voltage of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VTOP <Source> | Enable Measure Vtop. Enables the top value of the waveform measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VTOP? <Source> | Measure Vtop. Queries the measured top value of the waveform of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VBASe <Source> | Enable Measure Vbase. Enables the base value of the waveform measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VBASe? <Source> | Measure Vbase. Queries the measured base value of the waveform of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VAMP <Source> | Enable Measure Vamp. Enables the amplitude (Vtop - Vbase) measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VAMP? <Source> | Measure Vamp. Queries the measured amplitude (Vtop - Vbase) of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VAVG <Source> | Enable Measure Vavg. Enables the average voltage measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VAVG? <Source> | Measure Vavg. Queries the measured average voltage of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VRMS <Source> | Enable Measure Vrms. Enables the RMS voltage measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:VRMS? <Source> | Measure Vrms. Queries the measured RMS voltage of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:PERiod <Source> | Enable Measure Period. Enables the period measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:PERiod? <Source> | Measure Period. Queries the measured period of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:FREQuency <Source> | Enable Measure Frequency. Enables the frequency measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:FREQuency? <Source> | Measure Frequency. Queries the measured frequency of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:RTIMe <Source> | Enable Measure Rise Time. Enables the rise time measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:RTIMe? <Source> | Measure Rise Time. Queries the measured rise time of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:FTIMe <Source> | Enable Measure Fall Time. Enables the fall time measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:FTIMe? <Source> | Measure Fall Time. Queries the measured fall time of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:PWIDth <Source> | Enable Measure Positive Width. Enables the positive pulse width measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:PWIDth? <Source> | Measure Positive Width. Queries the measured positive pulse width of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:NWIDth <Source> | Enable Measure Negative Width. Enables the negative pulse width measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:NWIDth? <Source> | Measure Negative Width. Queries the measured negative pulse width of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:PDUTy <Source> | Enable Measure Positive Duty. Enables the positive duty cycle measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:PDUTy? <Source> | Measure Positive Duty. Queries the measured positive duty cycle of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:NDUTy <Source> | Enable Measure Negative Duty. Enables the negative duty cycle measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:NDUTy? <Source> | Measure Negative Duty. Queries the measured negative duty cycle of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:OVERshoot <Source> | Enable Measure Overshoot. Enables the overshoot measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:OVERshoot? <Source> | Measure Overshoot. Queries the measured overshoot of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:PREShoot <Source> | Enable Measure Preshoot. Enables the preshoot measurement on the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:PREShoot? <Source> | Measure Preshoot. Queries the measured preshoot of the specified source. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:CLEar ALL | Clear Measurements. Clears all the automatic measurement items currently displayed. | None |
| :MEASure:AMSource <Source> | Measure All Source. Sets the source of the all-parameter measurement function. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:STATistic:DISPlay ON | Statistics On. Turns on the statistic function for the automatic measurements. | None |
| :MEASure:STATistic:DISPlay OFF | Statistics Off. Turns off the statistic function for the automatic measurements. | None |
| :MEASure:STATistic:RESet | Statistics Reset. Clears the measurement statistic history and restarts the statistics. | None |
| :MEASure:SETup:MAX <Percent> | Threshold Upper. Sets the upper measurement threshold as a percentage of the amplitude. | Number |
| :MEASure:SETup:MID <Percent> | Threshold Middle. Sets the middle measurement threshold as a percentage of the amplitude. | Number |
| :MEASure:SETup:MIN <Percent> | Threshold Lower. Sets the lower measurement threshold as a percentage of the amplitude. | Number |
| :MEASure:SETup:DSA <Source> | Delay Source A. Sets source A of the delay measurement. | Text: CHANnel1,CHANnel2 |
| :MEASure:SETup:DSB <Source> | Delay Source B. Sets source B of the delay measurement. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:SETup:PSA <Source> | Phase Source A. Sets source A of the phase measurement. | Text: CHANnel1,CHANnel2 |
| :MEASure:SETup:PSB <Source> | Phase Source B. Sets source B of the phase measurement. | Text: CHANnel1,CHANnel2,MATH |
| :MEASure:COUNter:SOURce <Source> | Counter Source. Sets the source of the hardware frequency counter. | Text: CHANnel1,CHANnel2,EXT |
| :MEASure:COUNter:SOURce OFF | Counter Off. Disables the hardware frequency counter. | None |
| :MEASure:COUNter:VALue? | Get Counter Value. Queries the frequency counter measurement result in Hz. | None |
| Command | What it does | Arguments |
|---|---|---|
| :CHANnel<Channel>:DISPlay ON | Channel On. Turns on the display of the specified analog channel. | Text: 1,2 |
| :CHANnel<Channel>:DISPlay OFF | Channel Off. Turns off the display of the specified analog channel. | Text: 1,2 |
| :CHANnel<Channel>:DISPlay? | Get Channel State. Queries the on/off status of the specified analog channel (returns 1 or 0). | Text: 1,2 |
| :CHANnel<Channel>:COUPling <Coupling> | Channel Coupling. Sets the input coupling mode of the specified analog channel. | Text: 1,2; Text: AC,DC,GND |
| :CHANnel<Channel>:COUPling? | Get Channel Coupling. Queries the input coupling mode of the specified analog channel. | Text: 1,2 |
| :CHANnel<Channel>:SCALe <Scale> | Channel Scale. Sets the vertical scale of the specified channel in V/div. | Text: 1,2; Number |
| :CHANnel<Channel>:SCALe? | Get Channel Scale. Queries the vertical scale of the specified channel in V/div. | Text: 1,2 |
| :CHANnel<Channel>:OFFSet <Offset> | Channel Offset. Sets the vertical offset of the specified channel in volts. | Text: 1,2; Number |
| :CHANnel<Channel>:OFFSet? | Get Channel Offset. Queries the vertical offset of the specified channel in volts. | Text: 1,2 |
| :CHANnel<Channel>:PROBe <Ratio> | Channel Probe Ratio. Sets the probe attenuation ratio of the specified channel. | Text: 1,2; Number: 0.01,0.02,0.05,0.1,0.2,0.5,1,2,5,10,20,50,100,200,500,1000 |
| :CHANnel<Channel>:UNITs <Unit> | Channel Unit. Sets the amplitude display unit of the specified channel. | Text: 1,2; Text: VOLTage,WATT,AMPere,UNKNown |
| :CHANnel<Channel>:BWLimit <Limit> | Bandwidth Limit On. Enables the bandwidth limit of the specified channel at the selected cut-off frequency. | Text: 1,2; Text: 20M,100M |
| :CHANnel<Channel>:BWLimit OFF | Bandwidth Limit Off. Disables the bandwidth limit of the specified channel (full bandwidth). | Text: 1,2 |
| :CHANnel<Channel>:INVert ON | Channel Invert On. Turns on waveform invert for the specified channel. | Text: 1,2 |
| :CHANnel<Channel>:INVert OFF | Channel Invert Off. Turns off waveform invert for the specified channel. | Text: 1,2 |
| :CHANnel<Channel>:VERNier ON | Fine Adjust On. Turns on the fine adjustment of the vertical scale for the specified channel. | Text: 1,2 |
| :CHANnel<Channel>:VERNier OFF | Fine Adjust Off. Turns off the fine adjustment of the vertical scale (1-2-5 steps only). | Text: 1,2 |
| :CHANnel<Channel>:TCAL <Delay> | Channel Delay Calibration. Sets the channel delay calibration time in seconds to compensate for probe/cable skew. | Text: 1,2; Number |
| Command | What it does | Arguments |
|---|---|---|
| :TRIGger:MODE <Type> | Trigger Type. Selects the trigger type. | Text: EDGE,PULSe,RUNT,WIND,NEDG,SLOPe,VIDeo,PATTern,DELay,TIMeout,DURATion,SHOLd,RS232,IIC,SPI,USB,CAN |
| :TRIGger:MODE? | Get Trigger Type. Queries the trigger type currently selected. | None |
| :TRIGger:SWEep <Sweep> | Trigger Sweep. Sets the trigger mode to auto, normal or single. | Text: AUTO,NORMal,SINGle |
| :TRIGger:COUPling <Coupling> | Trigger Coupling. Sets the trigger coupling type (edge trigger with an analog source only). | Text: DC,AC,LFReject,HFReject |
| :TRIGger:HOLDoff <Time> | Trigger Holdoff. Sets the trigger holdoff time in seconds. | Number |
| :TRIGger:NREJect ON | Noise Reject On. Enables trigger noise rejection to reduce false triggering. | None |
| :TRIGger:NREJect OFF | Noise Reject Off. Disables trigger noise rejection. | None |
| :TRIGger:STATus? | Get Trigger Status. Queries the current trigger status (TD, WAIT, RUN, AUTO or STOP). | None |
| :TRIGger:EDGe:SOURce <Source> | Trigger Edge Source. Sets the trigger source used by the edge trigger. | Text: CHANnel1,CHANnel2,EXT,ACLine |
| :TRIGger:EDGe:SLOPe <Slope> | Trigger Edge Slope. Sets the edge type (rising, falling or either) used by the edge trigger. | Text: POSitive,NEGative,RFALl |
| :TRIGger:EDGe:LEVel <Level> | Trigger Edge Level. Sets the edge trigger level in the amplitude unit of the trigger source. | Number |
| :TRIGger:EDGe:LEVel? | Get Trigger Edge Level. Queries the edge trigger level. | None |
| :TRIGger:PULSe:SOURce <Source> | Trigger Pulse Source. Sets the trigger source used by the pulse width trigger. | Text: CHANnel1,CHANnel2,EXT |
| :TRIGger:PULSe:WHEN <Condition> | Trigger Pulse When. Sets the trigger condition of the pulse width trigger. | Text: PGReater,PLESs,NGReater,NLESs,PGLess,NGLess |
| :TRIGger:PULSe:LWIDth <Width> | Trigger Pulse Lower Width. Sets the lower pulse width limit of the pulse width trigger in seconds. | Number |
| :TRIGger:PULSe:UWIDth <Width> | Trigger Pulse Upper Width. Sets the upper pulse width limit of the pulse width trigger in seconds. | Number |
| :TRIGger:PULSe:LEVel <Level> | Trigger Pulse Level. Sets the trigger level of the pulse width trigger. | Number |
| Command | What it does | Arguments |
|---|---|---|
| :WAVeform:SOURce <Source> | Waveform Source. Sets the channel whose waveform data will be read. | Text: CHANnel1,CHANnel2,MATH |
| :WAVeform:MODE <Mode> | Waveform Mode. Sets the reading mode of the waveform data (screen data or internal memory data). | Text: NORMal,RAW,MAXimum |
| :WAVeform:FORMat <Format> | Waveform Format. Sets the return format of the waveform data. | Text: WORD,BYTE,ASCii |
| :WAVeform:STARt <Point> | Waveform Start. Sets the start point of the waveform data reading. | Number |
| :WAVeform:STOP <Point> | Waveform Stop. Sets the stop point of the waveform data reading. | Number |
| :WAVeform:DATA? | Get Waveform Data. Reads the waveform data of the selected source in the selected format. | None |
| :WAVeform:PREamble? | Get Waveform Preamble. Queries the waveform parameters (format, type, points, count, X/Y increments, origins and references). | None |
| :WAVeform:XINCrement? | Get X Increment. Queries the time between two neighbouring waveform points on the X axis. | None |
| :WAVeform:XORigin? | Get X Origin. Queries the start time of the waveform data on the X axis. | None |
| :WAVeform:XREFerence? | Get X Reference. Queries the reference time of the waveform data on the X axis. | None |
| :WAVeform:YINCrement? | Get Y Increment. Queries the voltage value per unit of the waveform data on the Y axis. | None |
| :WAVeform:YORigin? | Get Y Origin. Queries the vertical offset of the waveform data relative to the Y reference. | None |
| :WAVeform:YREFerence? | Get Y Reference. Queries the vertical reference position of the waveform data on the Y axis. | None |
| Command | What it does | Arguments |
|---|---|---|
| :CURSor:MODE <Mode> | Cursor Mode. Enables cursor measurement in the selected mode. | Text: MANual,TRACk,AUTO,XY |
| :CURSor:MODE OFF | Cursor Off. Disables the cursor measurement function. | None |
| :CURSor:MANual:SOURce <Source> | Cursor Source. Sets the channel the manual cursors measure. | Text: CHANnel1,CHANnel2,MATH |
| :CURSor:MANual:TYPE <Type> | Cursor Type. Sets the manual cursor type (X for time, Y for amplitude). | Text: TIME,AMPLitude |
| :CURSor:MANual:CAX <Position> | Cursor AX. Sets the horizontal position of cursor A in screen pixels. | Number: 0-699 |
| :CURSor:MANual:CBX <Position> | Cursor BX. Sets the horizontal position of cursor B in screen pixels. | Number: 0-699 |
| :CURSor:MANual:CAY <Position> | Cursor AY. Sets the vertical position of cursor A in screen pixels. | Number: 0-399 |
| :CURSor:MANual:CBY <Position> | Cursor BY. Sets the vertical position of cursor B in screen pixels. | Number: 0-399 |
| :CURSor:MANual:XDELta? | Get Cursor dX. Queries the time difference between cursor A and cursor B. | None |
| :CURSor:MANual:YDELta? | Get Cursor dY. Queries the amplitude difference between cursor A and cursor B. | None |
| Command | What it does | Arguments |
|---|---|---|
| :TIMebase:MAIN:SCALe <Scale> | Timebase Scale. Sets the main timebase scale in s/div. | Number |
| :TIMebase:MAIN:SCALe? | Get Timebase Scale. Queries the main timebase scale in s/div. | None |
| :TIMebase:MAIN:OFFSet <Offset> | Timebase Offset. Sets the main timebase (horizontal) offset in seconds relative to the trigger point. | Number |
| :TIMebase:MAIN:OFFSet? | Get Timebase Offset. Queries the main timebase (horizontal) offset in seconds. | None |
| :TIMebase:MODE <Mode> | Timebase Mode. Sets the horizontal timebase mode (YT, XY or Roll). | Text: MAIN,XY,ROLL |
| :TIMebase:DELay:ENABle ON | Delayed Sweep On. Enables the delayed sweep (zoom) window. | None |
| :TIMebase:DELay:ENABle OFF | Delayed Sweep Off. Disables the delayed sweep (zoom) window. | None |
| :TIMebase:DELay:SCALe <Scale> | Delayed Timebase Scale. Sets the delayed timebase scale in s/div. | Number |
| :TIMebase:DELay:OFFSet <Offset> | Delayed Timebase Offset. Sets the delayed timebase offset in seconds. | Number |
| Command | What it does | Arguments |
|---|---|---|
| :ACQuire:TYPE <Type> | Acquire Type. Sets the acquisition mode of the oscilloscope. | Text: NORMal,AVERages,PEAK,HRESolution |
| :ACQuire:TYPE? | Get Acquire Type. Queries the acquisition mode currently selected. | None |
| :ACQuire:AVERages <Count> | Acquire Averages. Sets the number of averages in the average acquisition mode (powers of 2). | Number |
| :ACQuire:AVERages? | Get Acquire Averages. Queries the number of averages used in the average acquisition mode. | None |
| :ACQuire:MDEPth <Depth> | Memory Depth. Sets the memory depth in points (AUTO or a discrete value that depends on the number of enabled channels). | Text |
| :ACQuire:MDEPth? | Get Memory Depth. Queries the current memory depth in points or AUTO. | None |
| :ACQuire:SRATe? | Get Sample Rate. Queries the current sample rate in Sa/s. | None |
| Command | What it does | Arguments |
|---|---|---|
| :DISPlay:TYPE <Type> | Display Type. Sets the waveform display mode to vectors or dots. | Text: VECTors,DOTS |
| :DISPlay:GRADing:TIME <Time> | Persistence Time. Sets the waveform persistence time in seconds (MIN or INFinite also accepted). | Text: MIN,0.05,0.1,0.2,0.5,1,2,5,10,20,INFinite |
| :DISPlay:GRID <Grid> | Display Grid. Sets the screen grid type. | Text: FULL,HALF,NONE |
| :DISPlay:WBRightness <Percent> | Waveform Brightness. Sets the waveform display brightness from 0 to 100 percent. | Number |
| :DISPlay:GBRightness <Percent> | Grid Brightness. Sets the screen grid brightness from 0 to 100 percent. | Number |
| :DISPlay:CLEar | Clear Display. Clears all the waveforms currently displayed on the screen. | None |
| Command | What it does | Arguments |
|---|---|---|
| :SYSTem:BEEPer ON | Beeper On. Turns on the instrument beeper. | None |
| :SYSTem:BEEPer OFF | Beeper Off. Turns off the instrument beeper. | None |
| :SYSTem:ERRor? | Get Error. Queries and clears the next message in the system error queue. | None |
| Command | What it does | Arguments |
|---|---|---|
| [PNG:DISPlay:DATA?] | Capture. Reads the screenshot of the current display back to the controller as a PNG image. | None |
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| :CALibrate:STARt | Self Calibration Start. Starts the instrument self-calibration; disconnect all inputs before running it. | None |
| :CALibrate:QUIT | Self Calibration Quit. Exits the self-calibration procedure. | None |
| Command | What it does | Arguments |
|---|---|---|
| :AUToscale | Auto Scale. Enables the waveform auto setting function to display the input signals at the best status. | None |
| Command | What it does | Arguments |
|---|---|---|
| :RUN | Run. Starts the oscilloscope acquisition (equivalent to pressing RUN on the front panel). | None |
| Command | What it does | Arguments |
|---|---|---|
| :STOP | Stop. Stops the oscilloscope acquisition and freezes the displayed waveform. | None |
| Command | What it does | Arguments |
|---|---|---|
| :SINGle | Single Trigger. Sets the oscilloscope to the single trigger mode so it triggers once and then stops. | None |
| Command | What it does | Arguments |
|---|---|---|
| :TFORce | Force Trigger. Generates a trigger signal forcefully (valid in normal and single trigger modes). | None |
| Command | What it does | Arguments |
|---|---|---|
| :CLEar | Clear Waveforms. Clears all the waveforms currently displayed on the screen. | None |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial number, firmware version). | None |
| *RST | Reset. Restores the instrument to its factory default state. | None |
| *CLS | Clear Status. Clears all the event registers and the error queue. | None |
| *TST? | Self Test. Runs the instrument self-test and returns the result. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *ESR? | Get Event Status. Queries and clears the standard event status register. | None |
| *STB? | Get Status Byte. Queries the status byte register. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Rigol's programming documentation for the DS2072A and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Rigol's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The Rigol DS2072A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 154 SCPI commands for it: 48 queries that read values or state, and 106 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, :AUToscale and :MEASure:VPP? CHANnel1.
:MEASure:VPP? CHANnel1 (measure vpp). Queries the measured peak-to-peak voltage of the specified source. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Rigol DS2072A through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.