The Keysight N6952A power supply is controlled remotely with SCPI commands. TestFlow's instrument library holds 108 commands for it, 42 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the N6952A on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Keysight N6952A and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Keysight N6952A's VISA address
# Paste the address of your Keysight N6952A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("OUTP ON") # Output On
print(inst.query("MEAS:VOLT?")) # Measure Voltage
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Keysight N6952A and writes the report from the measured results.
Describe the test in a sentence, for example “output on on the N6952A, then measure voltage and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
108 commands in 16 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| CURR:LIM <current> | Set Current Limit. Sets the positive current limit used in voltage priority mode. | Number: 0 to 102% of rating, or MIN|MAX (units amperes; negative limit set separately) |
| CURR:LIM? | Query Current Limit. Returns the positive current limit used in voltage priority mode. | None |
| CURR:LIM:NEG <current> | Set Negative Current Limit. Sets the negative current limit. | Number: -10.2% of rating to 0 (up to -102% with power dissipator), or MIN|MAX (units amperes) |
| CURR:PROT:STAT <state> | Set Over-Current Protection State. Enables or disables over-current protection. | Text: 0|OFF|1|ON |
| CURR:PROT:STAT? | Query Over-Current Protection State. Returns 0 or 1 for the over-current protection state. | None |
| CURR:PROT:DEL <seconds> | Set Over-Current Protection Delay. Sets the delay before over-current protection becomes active. | Number: 0 to 0.255 seconds, or MIN|MAX |
| CURR:SHAR <state> | Set Current Sharing. Enables or disables current sharing between paralleled units. | Text: 0|OFF|1|ON |
| CURR:SHAR? | Query Current Sharing. Returns 0 or 1 for the current sharing state. | None |
| CURR <current> | Set Current. Sets the output current in amperes (current priority mode). | Number: -10.2% to 102% of current rating in A, or MIN/MAX |
| CURR? | Query Current Setting. Returns the programmed output current. | None |
| CURR:LIM:POS <current> | Set Positive Current Limit. Sets the positive current limit (voltage priority mode). | Number: 0 to current rating in A, or MIN/MAX |
| CURR:LIM:POS? | Query Positive Current Limit. Returns the positive current limit. | None |
| CURR:LIM:NEG? MIN | Query Most-Negative Current Limit. Returns the most-negative current limit, which reveals whether a power dissipator is recognized. | None |
| CURR:TRIG <current> | Set Triggered Current. Sets the current step level transferred when a step is triggered. | Number: -10.2% to 102% of current rating in A, or MIN/MAX |
| CURR:MODE <mode> | Set Current Transient Mode. Sets the current transient mode. | Text: FIXed|STEP|LIST|ARB |
| CURR:PROT:DEL <time> | Set Over-Current Protection Delay (CURR:PROT:DEL). Sets the over-current protection delay time. | Number: delay in seconds, or MIN/MAX |
| CURR:PROT:DEL? | Query Over-Current Protection Delay. Returns the over-current protection delay. | None |
| CURR:PROT:DEL:STAR <event> | Set Over-Current Delay Start. Selects what starts the over-current protection delay timer. | Text: SCHange|CCTRans |
| CURR:PROT:STAT ON | Enable Over-Current Protection. Enables OCP so the output turns off when it transitions from CV to current limit. | None |
| CURR:PROT:STAT OFF | Disable Over-Current Protection. Disables over-current protection. | None |
| CURR:PROT:DEL:STAR <source> | Set OCP Delay Start. Selects what starts the over-current delay timer. | Text: SCH (output settings change) or CCTR (any transition into current limit) |
| CURR:SLEW <rate> | Set Current Slew Rate. Sets the rate at which current changes to a new setting. | Text: Amperes per second number, or MAX / INF for fastest |
| CURR:SLEW? | Query Current Slew Rate. Returns the current slew rate. | None |
| CURR:SHAR:STAT <state> | Set Current Sharing (CURR:SHAR:STAT). Enables or disables current sharing on paralleled units. | Text: 0|OFF|1|ON |
| CURR:SHAR:STAT? | Query Current Sharing (CURR:SHAR:STAT?). Returns whether current sharing is enabled. | None |
| Command | What it does | Arguments |
|---|---|---|
| OUTP ON | Output On. Enables the output. | None |
| OUTP OFF | Output Off. Disables the output. | None |
| OUTP? | Output State. Returns 0 if the output is off or 1 if it is on. | None |
| OUTP:PROT:CLE | Clear Latched Protection. Clears a latched protection condition after its cause is removed. | None |
| OUTP:PROT:MODE <mode> | Set Output Protection Mode. Selects the turn-off behavior for protection conditions. | Text: HIGHZ|LOWZ |
| OUTP:COUP <state> | Set Output Couple. Enables or disables output on/off coupling between units. | Text: 0|OFF|1|ON |
| OUTP:PROT:USER:SOUR <source> | Set User Protection Source. Selects the expression that triggers user-defined protection. | Text: EXPR1..EXPR8 |
| OUTP:PROT:USER:STAT <state> | Set User Protection State. Enables or disables user-defined protection. | Text: 0|OFF|1|ON |
| OUTP:INH:MODE <mode> | Set Inhibit Mode. Sets how the Inhibit input controls the output. | Text: LATChing|LIVE|OFF |
| OUTP:PROT:WDOG ON | Enable Output Watchdog. Enables the watchdog that shuts the output down if no remote I/O activity occurs. | None |
| OUTP:PROT:WDOG:DEL <seconds> | Set Watchdog Delay. Sets the watchdog timeout period. | Number: 1 to 3600 seconds |
| OUTP:PROT:TEMP:MARG? | Get Over-Temperature Margin. Returns the remaining margin to over-temperature protection in degrees C. | None |
| OUTP:REL:LOCK ON | Lock Output Relays Closed. Leaves the output relays closed at all times, removing relay turn-on and turn-off delays. | None |
| OUTP:DEL:RISE <seconds> | Set Output Turn-On Delay. Sets the output turn-on sequence delay. | Number: delay in seconds, non-negative |
| OUTP:DEL:FALL <seconds> | Set Output Turn-Off Delay. Sets the output turn-off sequence delay. | Number: delay in seconds, non-negative |
| Command | What it does | Arguments |
|---|---|---|
| VOLT <voltage> | Set Voltage. Sets the output voltage in voltage priority mode. | Number: 0.1% to 102% of rating, or MIN|MAX (units volts) |
| VOLT? | Query Voltage. Returns the programmed output voltage. | None |
| VOLT:LIM <voltage> | Set Voltage Limit. Sets the voltage limit used in current priority mode. | Number: 0.1% to 102% of rating, or MIN|MAX (units volts) |
| VOLT:LIM? | Query Voltage Limit. Returns the voltage limit used in current priority mode. | None |
| VOLT:PROT <voltage> | Set Over-Voltage Protection. Sets the over-voltage protection level. | Number: 0 to 120% of rating, or MIN|MAX (units volts) |
| VOLT:PROT? | Query Over-Voltage Protection. Returns the over-voltage protection level. | None |
| VOLT:TRIG <voltage> | Set Triggered Voltage. Sets the voltage step level transferred when a step is triggered. | Number: 0 to voltage rating in V, or MIN/MAX |
| VOLT:MODE <mode> | Set Voltage Transient Mode. Sets the voltage transient mode. | Text: FIXed|STEP|LIST|ARB |
| VOLT:SLEW <rate> | Set Voltage Slew Rate. Sets the rate at which voltage changes to a new setting. | Text: Volts per second number, or MAX / INF for fastest |
| VOLT:BWID <mode> | Set Voltage Bandwidth Mode. Selects the voltage compensation bandwidth mode. | Text: LOW,HIGH1 |
| VOLT:MODE STEP | Set Transient Mode Step. Enables the voltage step transient function. | None |
| VOLT:SLEW? | Query Voltage Slew Rate. Returns the voltage slew rate. | None |
| Command | What it does | Arguments |
|---|---|---|
| MEAS:VOLT? | Measure Voltage. Takes a measurement and returns the averaged DC output voltage. | None |
| MEAS:CURR? | Measure Current. Takes a measurement and returns the averaged DC output current. | None |
| MEAS:POW? | Measure Power. Takes a measurement and returns the averaged DC output power. | None |
| MEAS:VOLT:ACDC? | Measure RMS Voltage. Returns the total RMS (AC plus DC) output voltage. | None |
| MEAS:CURR:ACDC? | Measure RMS Current. Returns the total RMS (AC plus DC) output current. | None |
| MEAS:VOLT:MAX? | Measure Maximum Voltage. Returns the maximum digitized voltage value. | None |
| MEAS:VOLT:MIN? | Measure Minimum Voltage. Returns the minimum digitized voltage value. | None |
| MEAS:CURR:MAX? | Measure Maximum Current. Returns the maximum digitized current value. | None |
| MEAS:CURR:MIN? | Measure Minimum Current. Returns the minimum digitized current value. | None |
| Command | What it does | Arguments |
|---|---|---|
| SENS:ELOG:PER <seconds> | Set Elog Integration Period. Sets the Elog integration period. | Number: 0.0001024 to 60 s |
| SENS:SWE:NPLC <cycles> | Set Measurement NPLC. Sets the measurement time in power line cycles. | Number: Number of power line cycles |
| SENS:WIND <window> | Set Measurement Window. Selects the window function used for average measurements. | Text: RECT (rectangular) or HANN (Hanning) |
| SENS:SWE:TINT <seconds> | Set Measurement Time Interval. Sets the time interval between measurement samples. | Number: 5.12e-6 to 40000 seconds |
| SENS:SWE:POIN <points> | Set Measurement Points. Sets the number of samples in a measurement acquisition. | Number: Sample points, up to 512 K |
| SENS:AHO:RES | Reset Amp-Hours. Resets the accumulated amp-hours to zero. | None |
| SENS:WHO:RES | Reset Watt-Hours. Resets the accumulated watt-hours to zero. | None |
| SENS:FAUL:STAT <state> | Set Sense Fault Detection. Enables or disables remote sense lead fault detection. | Text: 0|OFF|1|ON |
| SENS:FAUL:STAT? | Query Sense Fault Detection. Returns whether remote sense fault detection is enabled. | None |
| Command | What it does | Arguments |
|---|---|---|
| FETC:VOLT? | Fetch Voltage. Returns the averaged voltage from the previously acquired data without a new measurement. | None |
| FETC:CURR? | Fetch Current. Returns the averaged current from the previously acquired data without a new measurement. | None |
| FETC:ELOG? <records> | Fetch Elog Records. Returns and removes the requested Elog records from the buffer. | Number: 1 to 1000 records |
| FETC:POW? | Fetch Power. Returns the average power from the most recent acquisition. | None |
| FETC:AHO? | Get Amp-Hours. Returns accumulated amp-hours. | None |
| FETC:WHO? | Get Watt-Hours. Returns accumulated watt-hours. | None |
| Command | What it does | Arguments |
|---|---|---|
| FUNC VOLT | Set Voltage Priority Mode. Sets the output regulation to voltage priority. | None |
| FUNC CURR | Set Current Priority Mode. Sets the output regulation to current priority. | None |
| FUNC? | Query Regulation Mode. Returns CURR or VOLT for the current regulation priority. | None |
| FUNC <mode> | Set Priority Mode. Selects voltage or current priority mode; the output turns off and settings revert to reset values. | Text: CURR (current priority) or VOLT (voltage priority) |
| Command | What it does | Arguments |
|---|---|---|
| DIG:PIN<n>:FUNC <function> | Set Digital Pin Function. Sets the function of a digital port pin. | Number: pin 1 to 7; Text: DIO|DINP|EXPR1..EXPR8|FAUL|INH|ONC|OFFC|TINP|TOUT |
| DIG:PIN<n>:POL <polarity> | Set Digital Pin Polarity. Sets the signal polarity of a digital port pin. | Number: pin 1 to 7; Text: POS|NEG |
| DIG:OUTP:DATA <value> | Set Digital Output Data. Sets the output data for pins configured as digital I/O. | Number: 0 to 127 (bit weights on pins 1 to 7) |
| DIG:INP:DATA? | Read Digital Input Data. Returns the data on pins configured as digital input. | None |
| Command | What it does | Arguments |
|---|---|---|
| TRIG:TRAN:SOUR <source> | Set Transient Trigger Source. Selects the trigger source for output transients. | Text: BUS|IMMediate|PIN1..PIN7|EXPR1..EXPR8 |
| TRIG:ACQ:SOUR <source> | Set Acquisition Trigger Source. Selects the trigger source for measurements and Elog. | Text: BUS,CURRent1,EXTernal,PIN1-PIN7,EXPRession1-EXPRession8,TRANsient1,VOLTage1 |
| TRIG:TRAN | Trigger Transient. Generates a transient trigger on the master unit. | None |
| TRIG:ELOG | Trigger Elog. Generates an immediate trigger to start Elog data collection. | None |
| Command | What it does | Arguments |
|---|---|---|
| RES:STAT ON | Enable Output Resistance. Enables output resistance programming. | None |
| RES <ohms> | Set Output Resistance (RES). Sets the output resistance level for resistance programming. | Number: 0 to 6.4 (ohm) |
| RES? | Query Output Resistance. Returns the programmed output resistance level. | None |
| RES:STAT <state> | Set Output Resistance Enable. Enables or disables output resistance programming. | Text: 0|OFF|1|ON |
| Command | What it does | Arguments |
|---|---|---|
| ABOR:TRAN | Abort Transient. Cancels triggered transient actions. | None |
| ABOR:ACQ | Abort Acquisition. Cancels triggered measurements. | None |
| ABOR:ELOG | Abort Elog. Stops external data logging. | None |
| Command | What it does | Arguments |
|---|---|---|
| SYST:ERR? | Error Query. Reads and clears one error from the error queue. | None |
| SYST:TEMP:AMB? | Get Ambient Temperature. Returns the ambient air inlet temperature in degrees C. | None |
| Command | What it does | Arguments |
|---|---|---|
| INIT:TRAN | Initiate Transient. Arms the transient trigger system on the source. | None |
| INIT:ELOG | Initiate Elog. Starts the external data logging trigger system. | None |
| Command | What it does | Arguments |
|---|---|---|
| ARB:COUN <count> | Set Arb Repeat Count. Sets how many times the arbitrary waveform repeats. | Number: 1 to 256, or INFinity |
| Command | What it does | Arguments |
|---|---|---|
| STAT:OPER:COND? | Query Operation Status. Returns the operation status condition register, used to check trigger and measurement states. | None |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the manufacturer, model, serial number and firmware revision string. | None |
| *RST | Reset. Resets the instrument to its *RST values, which leave the output off. | None |
| *CLS | Clear Status. Clears the event registers, status byte and error queue. | None |
| *ESR? | Event Status Register Query. Reads and clears the standard event status register. | None |
| *OPT? | Query Installed Options. Returns the installed options. | None |
| *STB? | Query Status Byte. Returns the status byte register value. | None |
| *OPC? | Query Operation Complete. Returns 1 when all pending operations are complete. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Keysight's programming documentation for the N6952A and checked when the agent runs it. The library marks this instrument as supporting *OPC? for operation-complete synchronisation. It reads errors back with SYSTem:ERRor?. Ranges, timing, and option-dependent commands are defined by Keysight's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The Keysight N6952A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 108 SCPI commands for it: 42 queries that read values or state, and 66 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTP ON and MEAS:VOLT?.
MEAS:VOLT? (measure voltage). Takes a measurement and returns the averaged DC output voltage. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Keysight N6952A through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.