The Keysight N5767A power supply is controlled remotely with SCPI commands. TestFlow's instrument library holds 75 commands for it, 39 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the N5767A on a real bench.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Keysight N5767A's VISA address
# Paste the address of your Keysight N5767A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("OUTPut:PROTection:CLEar") # Clear Output Protection
print(inst.query("MEASure:VOLTage:DC?")) # Measure DC Voltage
inst.close()Describe the test in a sentence, for example “clear output protection on the N5767A, then measure dc voltage and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
75 commands in 10 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| VOLTage:LEVel <value> | Set Voltage. Sets the immediate output voltage level in volts. | Number: 0 to rated output voltage; MIN | MAX |
| VOLTage:LEVel? | Query Voltage Setting. Returns the programmed output voltage level in volts. | None |
| VOLTage:LEVel:TRIGgered <value> | Set Triggered Voltage. Sets the triggered output voltage level transferred on trigger. | Number: 0 to rated output voltage; MIN | MAX |
| VOLTage:LEVel:TRIGgered? | Query Triggered Voltage. Returns the triggered output voltage level in volts. | None |
| VOLTage:LIMit:LOW <value> | Set Low Voltage Limit. Sets the low voltage limit below which voltage programming is ignored. | Number: 0 to maximum low limit for model; MIN | MAX |
| VOLTage:LIMit:LOW? | Query Low Voltage Limit. Returns the low voltage limit in volts. | None |
| VOLTage:PROTection:LEVel <value> | Set Over-Voltage Protection Level. Sets the over-voltage protection trip level in volts. | Number: model minimum to model maximum protection limit; MIN | MAX |
| VOLTage:PROTection:LEVel? | Query Over-Voltage Protection Level. Returns the over-voltage protection level in volts. | None |
| VOLT <voltage> | Set Voltage (VOLT). Programs the output voltage setpoint. | Number: 0 to 60 V |
| VOLT? | Query Voltage Setting (VOLT?). Returns the programmed output voltage setting. | None |
| VOLT:PROT:LEV <voltage> | Set Over-Voltage Protection. Sets the over-voltage protection trip level. | Number: 0 to 60 V, must be above the voltage setting |
| VOLT:PROT:LEV? | Query Over-Voltage Protection. Returns the over-voltage protection trip level. | None |
| VOLT:LIM:LOW <voltage> | Set Under-Voltage Limit. Sets the under-voltage limit for programming the voltage. | Number: 0 to 60 V, must be below the voltage setting |
| Command | What it does | Arguments |
|---|---|---|
| STATus:OPERation:EVENt? | Read Operation Event Register. Returns the operation event register, which clears on read (CC, CV, WTG bits). | None |
| STATus:OPERation:CONDition? | Read Operation Condition Register. Returns the live operation condition register (CC, CV, WTG bits). | None |
| STATus:OPERation:ENABle <value> | Set Operation Enable Mask. Sets the operation enable mask for the operation summary bit. | Number: 0 to 32767 |
| STATus:OPERation:ENABle? | Query Operation Enable Mask. Returns the operation enable mask. | None |
| STATus:QUEStionable:EVENt? | Read Questionable Event Register. Returns the questionable event register (OV, OC, PF, OT, INH, UNR), clears on read. | None |
| STATus:QUEStionable:CONDition? | Read Questionable Condition Register. Returns the live questionable condition register. | None |
| STATus:QUEStionable:ENABle <value> | Set Questionable Enable Mask. Sets the questionable enable mask for the questionable summary bit. | Number: 0 to 32767 |
| STATus:QUEStionable:ENABle? | Query Questionable Enable Mask. Returns the questionable enable mask. | None |
| STATus:PRESet | Preset Status Registers. Sets defined PTR bits and clears NTR and enable registers. | None |
| STAT:OPER? | Operation Status Query. Returns the operation status register value. | None |
| STAT:QUES? | Questionable Status Query. Returns the questionable status register value. | None |
| Command | What it does | Arguments |
|---|---|---|
| CURRent:LEVel <value> | Set Current. Sets the immediate output current level in amperes. | Number: 0 to rated output current; MIN | MAX |
| CURRent:LEVel? | Query Current Setting. Returns the programmed output current level in amperes. | None |
| CURRent:LEVel:TRIGgered <value> | Set Triggered Current. Sets the triggered output current level transferred on trigger. | Number: 0 to rated output current; MIN | MAX |
| CURRent:LEVel:TRIGgered? | Query Triggered Current. Returns the triggered output current level in amperes. | None |
| CURRent:PROTection:STATe <state> | Enable Over-Current Protection. Enables or disables over-current protection. | Text: ON | OFF |
| CURRent:PROTection:STATe? | Query Over-Current Protection State. Returns the over-current protection enable state. | None |
| CURR <current> | Set Current (CURR). Programs the output current limit setpoint. | Number: 0 to 25 A |
| CURR? | Query Current Setting (CURR?). Returns the programmed output current setting. | None |
| CURR:PROT:STAT <state> | Set Over-Current Protection. Enables or disables over-current protection. | Text: ON or OFF |
| CURR:PROT:STAT? | Query Over-Current Protection. Returns the over-current protection state. | None |
| Command | What it does | Arguments |
|---|---|---|
| OUTPut:STATe <state> | Set Output Enable. Enables or disables the power supply output. | Text: ON | OFF |
| OUTPut:STATe? | Query Output Enable. Returns 1 if the output is on, 0 if off. | None |
| OUTPut:PON:STATe <mode> | Set Power-On State. Selects reset state or last-off state at power-on. | Text: RST | AUTO |
| OUTPut:PON:STATe? | Query Power-On State. Returns the power-on state mode. | None |
| OUTPut:PROTection:CLEar | Clear Output Protection. Clears latched protection signals that disabled the output. | None |
| OUTP:STAT ON | Output On. Turns the power supply output on. | None |
| OUTP:STAT OFF | Output Off. Turns the power supply output off. | None |
| OUTP:STAT? | Output State Query. Returns 1 when the output is on and 0 when it is off. | None |
| OUTP:PROT:CLE | Clear Protection. Clears a tripped protection condition. | None |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:ERRor? | Query Error. Returns the next error number and message from the error queue. | None |
| SYSTem:VERSion? | Query SCPI Version. Returns the SCPI version number the instrument complies with. | None |
| SYSTem:COMMunicate:RLSTate <mode> | Set Remote Local State. Sets front panel control, remote control, or remote with front panel locked. | Text: LOCal | REMote | RWLock |
| SYSTem:COMMunicate:RLSTate? | Query Remote Local State. Returns the remote/local state of the instrument. | None |
| SYST:ERR? | Error Query. Returns and clears the most recent error from the error queue. | None |
| Command | What it does | Arguments |
|---|---|---|
| MEASure:VOLTage:DC? | Measure DC Voltage. Performs a measurement and returns the DC output voltage in volts. | None |
| MEASure:CURRent:DC? | Measure DC Current. Performs a measurement and returns the DC output current in amperes. | None |
| MEAS:VOLT? | Measure Voltage. Returns the measured output voltage. | None |
| MEAS:CURR? | Measure Current. Returns the measured output current. | None |
| Command | What it does | Arguments |
|---|---|---|
| INITiate | Initiate Trigger System. Initiates the trigger system so the next trigger changes the output. | None |
| INITiate:CONTinuous <state> | Set Continuous Trigger Initiation. Enables or disables continuous initiation of output triggers. | Text: ON | OFF |
| INITiate:CONTinuous? | Query Continuous Trigger Initiation. Returns the continuous trigger initiation state. | None |
| Command | What it does | Arguments |
|---|---|---|
| TRIGger | Immediate Trigger. Generates an immediate output trigger if the trigger system is initiated. | None |
| TRIGger:SOURce BUS | Set Trigger Source. Selects the bus as the output trigger source. | None |
| TRIGger:SOURce? | Query Trigger Source. Returns the output trigger source. | None |
| Command | What it does | Arguments |
|---|---|---|
| ABORt | Abort Trigger. Cancels trigger actions in progress and returns the trigger system to idle. | None |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify Instrument. Returns manufacturer, model, serial number and firmware revision. | None |
| *RST | Reset Instrument. Resets the power supply to its factory-defined state. | None |
| *TRG | Generate Trigger. Generates a bus trigger when the trigger source is BUS. | None |
| *CLS | Clear Status. Clears event registers, status byte and error queue. | None |
| *ESR? | Read Standard Event Register. Returns the standard event status register and clears it. | None |
| *ESE <value> | Set Standard Event Enable. Sets the standard event status enable register mask. | Number: 0 to 255 |
| *ESE? | Query Standard Event Enable. Returns the standard event status enable register mask. | None |
| *SRE <value> | Set Service Request Enable. Sets the service request enable register mask. | Number: 0 to 255 |
| *SRE? | Query Service Request Enable. Returns the service request enable register mask. | None |
| *STB? | Read Status Byte. Returns the status byte register without clearing it. | None |
| *OPC | Operation Complete. Sets the OPC bit in the standard event register when pending operations complete. | None |
| *OPC? | Operation Complete Query. Returns 1 when all pending operations are complete. | None |
| *WAI | Wait To Continue. Holds off further commands until all pending operations complete. | None |
| *OPT? | Query Option Numbers. Returns installed option identifiers; 0 means none. | None |
| *RCL <state> | Recall Instrument State. Restores a previously saved instrument state from memory location. | Number: 0 to 15 |
| *SAV <state> | Save Instrument State. Stores the present instrument state to memory location. | Number: 0 to 15 |
This reference is generated from TestFlow's instrument library, which is drafted from Keysight's programming documentation for the N5767A and checked when the agent runs it. The library marks this instrument as supporting *OPC? for operation-complete synchronisation. It reads errors back with SYSTem:ERRor?. Ranges, timing, and option-dependent commands are defined by Keysight's programming manual: check it before you rely on an edge case. Last updated November 12, 2026.
Yes. The Keysight N5767A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 75 SCPI commands for it: 39 queries that read values or state, and 36 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut:PROTection:CLEar and MEASure:VOLTage:DC?.
MEASure:VOLTage:DC? (measure dc voltage). Performs a measurement and returns the DC output voltage in volts. The full list of queries is in the command reference on this page, grouped by subsystem.