The Keysight E36233A power supply is controlled remotely with SCPI commands. TestFlow's instrument library holds 29 commands for it, 5 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the E36233A on a real bench.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Keysight E36233A's VISA address
# Paste the address of your Keysight E36233A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("OUTPut:STATe ON, (@1)") # Turn On
print(inst.query("MEASure:CURRent? (@1)")) # Measure current
inst.close()Describe the test in a sentence, for example “turn on on the E36233A, then measure current and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
29 commands in 10 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| OUTPut:STATe ON, (@<Channel>) | Turn On. Turning on the power supply | Text: 1,2 |
| OUTPut:STATe OFF, (@<Channel>) | Turn Off. Turning off the power supply (seeting output to 0 voltage) | Text: 1,2 |
| OUTPut:STATe? (@<Channel>) | Status. Reads if the power supply is ON or OFF | Text: 1,2 |
| OUTPut:STATe:DELay:FALL <delay> , (@<Channel>) | State fall delay. Sets the falling delay | Number; Text: 1,2 |
| OUTPut:STATe:DELay:RISE <delay> , (@<Channel>) | State rise delay. Sets the rising delay | Number; Text: 1,2 |
| OUTPut:STATe:PMODe <VOLTage | CURRent> , (@<Channel>) | Power mode. Sets the mode if current source or voltage source | Text: VOLTage,CURRent; Text: 1,2 |
| OUTPut:RELay <ON | OFF> , (@<Channel>) | Output Relay. Turning the output relay ON or OFF | Text: ON,OFF; Text: 1,2 |
| Command | What it does | Arguments |
|---|---|---|
| SOURce:CURRent:LEVel:IMMediate:AMPLitude <current>, (@<Channel>) | Set Current. Sets the power supply current limit | Number: MIN,MAX; Text: 1,2 |
| SOURce:VOLTage:LEVel:IMMediate:AMPLitude <voltage> , (@<Channel>) | Set voltage. Sets the power supply voltage | Number: MIN,MAX; Text: 1,2 |
| SOURce:CURRent:TRIGgered <current> , (@<Channel>) | Current trigger. Sets the current trigger | Text: MIN,MAX; Text: 1,2 |
| SOURce:CURRent:LEVel:IMMediate:STEP:INCRement <current> , (@<Channel>) | Current step. Sets the current step value | Number; Text: 1,2 |
| SOURce:CURRent:PROTection:LEVel:AMPLitude <current> , (@<Channel>) | Current protection. Sets the current protection value | Number; Text: 1,2 |
| Command | What it does | Arguments |
|---|---|---|
| DISPlay:TEXT:DATA "<Message>" | Display text. Display text on power supply screen | Text |
| DISPlay:WINDow:TEXT:DATA "" | Display clear. Clears display text | None |
| DISPlay:WINDow:STATe ON | Display ON. Enable text display on power supply screen | None |
| DISPlay:WINDow:STATe OFF | Display OFF. Disable text display on power supply screen | None |
| Command | What it does | Arguments |
|---|---|---|
| CURR:PROT:CLE (@<Channel>) | Clear protection. Clears the current protection value | Text: 1,2 |
| CURR:PROT:STAT ON, (@<Channel>) | Enable protection. Enables the current protection | Text: 1,2 |
| CURR:PROT:STAT OFF, (@<Channel>) | Disable protection. Disables the current protection | Text: 1,2 |
| CURR:PROT:TRIP? | Check protection. Checks if protection tripped or not | None |
| Command | What it does | Arguments |
|---|---|---|
| MEASure:CURRent? (@<Channel>) | Measure current. Measures the power supply current | Text: 1,2 |
| MEASure:VOLTage:DC? (@<Channel>) | Measure voltage. Measures the power supply voltage | Text: 1,2 |
| Command | What it does | Arguments |
|---|---|---|
| SENSe:DLOG:FUNCtion:CURRent <ON | OFF> , (@<Channel>) | Sense current. Sets the sense function to sens current | Text: ON,OFF; Text: 1,2 |
| SENSe:DLOG:FUNCtion:VOLTage <ON | OFF> , (@<Channel>) | Sense volt. Sets the sense function to sens voltage | Text: ON,OFF; Text: 1,2 |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:BEEPer:STATe <ON | OFF> | Beep. Sets the beep on or off | Text: ON,OFF |
| SYST:ERR? | Check errors. Checks if there is an error | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last mearurment to a variable | Text |
This reference is generated from TestFlow's instrument library, which is drafted from Keysight's programming documentation for the E36233A and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Keysight's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The Keysight E36233A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 29 SCPI commands for it: 5 queries that read values or state, and 24 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut:STATe ON, (@1) and MEASure:CURRent? (@1).
MEASure:CURRent? (@1) (measure current). Measures the power supply current The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Keysight E36233A through the TestFlow desktop app, and writes the report from the measured results.