Power Supply · SCPI command reference

Keysight E36231A SCPI commands

The Keysight E36231A power supply is controlled remotely with SCPI commands. TestFlow's instrument library holds 24 commands for it, 3 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the E36231A on a real bench.

Commands
24
Queries
3
Subsystems
8
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Keysight E36231A and writes the report from the measured results.

Get started

Control the Keysight E36231A from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Keysight E36231A's VISA address

# Paste the address of your Keysight E36231A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("OUTPut:STATe ON")  # Turn On
print(inst.query("MEASure:CURRent?"))  # Measure current

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Keysight E36231A and writes the report from the measured results.

Get started

Run a E36231A test without writing code

Describe the test in a sentence, for example “turn on on the E36231A, then measure current and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

24 commands in 8 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Output (OUTPut) (7)

CommandWhat it doesArguments
OUTPut:STATe ONTurn On. None
OUTPut:STATe OFFTurn Off. None
OUTPut:STATe?Status. None
OUTPut:STATe:DELay:FALL <delay>State fall delay. Number
OUTPut:STATe:DELay:RISE <delay>State rise delay. Number
OUTPut:STATe:PMODe <VOLTage | CURRent>Power mode. Text: VOLTage,CURRent
OUTPut:RELay <ON | OFF>Output Relay. Text: ON,OFF

Source (SOURce) (5)

CommandWhat it doesArguments
SOURce:CURRent:LEVel:IMMediate:AMPLitude <current>Set Current. Number: MIN,MAX
SOURce:VOLTage:LEVel:IMMediate:AMPLitude <voltage>Set voltage. Number: MIN,MAX
SOURce:CURRent:TRIGgered <current>Current trigger. Text: MIN,MAX
SOURce:CURRent:LEVel:IMMediate:STEP:INCRement <current>Current step. Number
SOURce:CURRent:PROTection:LEVel:AMPLitude <current>Current protection. Number

Display (DISPlay) (4)

CommandWhat it doesArguments
DISPlay:TEXT:DATA "<Message>"Display text. Text
DISPlay:WINDow:TEXT:DATA ""Display clear. None
DISPlay:WINDow:STATe ONDisplay ON. None
DISPlay:WINDow:STATe OFFDisplay OFF. None

Measurement (MEASure) (2)

CommandWhat it doesArguments
MEASure:CURRent?Measure current. None
MEASure:VOLTage:DC?Measure voltage. None

Sense (SENSe) (2)

CommandWhat it doesArguments
SENSe:DLOG:FUNCtion:CURRent <ON | OFF>Sense current. Text: ON,OFF
SENSe:DLOG:FUNCtion:VOLTage <ON | OFF>Sense volt. Text: ON,OFF

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Number

System (SYSTem) (1)

CommandWhat it doesArguments
SYSTem:BEEPer:STATe <ON | OFF>Beep. Text: ON,OFF

IEEE 488.2 common commands (2)

CommandWhat it doesArguments
*CLSCLS. None
*RSTRST. None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Keysight's programming documentation for the E36231A and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Keysight's programming manual: check it before you rely on an edge case. Last updated November 12, 2026.

Frequently asked questions

Does the Keysight E36231A support SCPI remote control?

Yes. The Keysight E36231A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 24 SCPI commands for it: 3 queries that read values or state, and 21 settings and actions.

How do I control the Keysight E36231A from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut:STATe ON and MEASure:CURRent?.

Which command reads a value from the Keysight E36231A?

MEASure:CURRent? (measure current). The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Keysight E36231A without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Keysight E36231A through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.