Power Supply · SCPI command reference

ITECH IT-N6300 SCPI commands

The ITECH IT-N6300 power supply is controlled remotely with SCPI commands. TestFlow's instrument library holds 20 commands for it, 5 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the IT-N6300 on a real bench.

Commands
20
Queries
5
Subsystems
8
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your ITECH IT-N6300 and writes the report from the measured results.

Get started

Control the ITECH IT-N6300 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the ITECH IT-N6300's VISA address

# Paste the address of your ITECH IT-N6300 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("VOLT:PROT:STAT ON")  # OVP Enable
print(inst.query("MEAS:VOLT?"))  # Measure volt

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your ITECH IT-N6300 and writes the report from the measured results.

Get started

Run a IT-N6300 test without writing code

Describe the test in a sentence, for example “ovp enable on the IT-N6300, then measure volt and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

20 commands in 8 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Voltage (VOLTage) (4)

CommandWhat it doesArguments
VOLT <Voltage>Set Voltage. Number
VOLT:PROT <OVP>Set OVP. Number
VOLT:PROT:STAT ONOVP Enable. None
VOLT:PROT:STAT OFFOVP Disable. None

Current (CURRent) (4)

CommandWhat it doesArguments
CURR <Current>Set Current. Number
CURR:PROT <Over current>Set OCP. Number
CURR:PROT:STAT ONOCP Enable. None
CURR:PROT:STAT OFFOCP Disable. None

Output (OUTPut) (3)

CommandWhat it doesArguments
OUTP ON,(@<Channel>)Turn on. Number: 1,2,3
OUTP OFF,(@<Channel>)Turn off. Number: 1,2,3
OUTP? (@<Channel>)Status. Number: 1,2,3

Measurement (MEASure) (3)

CommandWhat it doesArguments
MEAS:VOLT?Measure volt. None
MEAS:CURR?Measure current. None
MEASure:POWer?Measure power. None

System (SYSTem) (2)

CommandWhat it doesArguments
SYSTem:ERRor?Read errors. None
SYSTem:<LOCal/REMote>Sys remote. Text: LOCal,REMote,RWLock

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<Ms>)Wait. Number

Trigger (TRIGger) (1)

CommandWhat it doesArguments
TRIG;Trigger output. None

IEEE 488.2 common commands (2)

CommandWhat it doesArguments
*RSTReset. None
*CLSClear status. None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from ITECH's programming documentation for the IT-N6300 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by ITECH's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the ITECH IT-N6300 support SCPI remote control?

Yes. The ITECH IT-N6300 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 20 SCPI commands for it: 5 queries that read values or state, and 15 settings and actions.

How do I control the ITECH IT-N6300 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, VOLT:PROT:STAT ON and MEAS:VOLT?.

Which command reads a value from the ITECH IT-N6300?

MEAS:VOLT? (measure volt). The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the ITECH IT-N6300 without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the ITECH IT-N6300 through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.