The ITECH IT-M3140 power supply is controlled remotely with SCPI commands. TestFlow's instrument library holds 23 commands for it, 5 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the IT-M3140 on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your ITECH IT-M3140 and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the ITECH IT-M3140's VISA address
# Paste the address of your ITECH IT-M3140 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("OUTP ON") # Turn on
print(inst.query("MEAS:VOLT?")) # Measure volt
inst.close()Describe the test; TestFlow's agent uses this command set to drive your ITECH IT-M3140 and writes the report from the measured results.
Describe the test in a sentence, for example “turn on on the IT-M3140, then measure volt and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
23 commands in 8 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| VOLT <Voltage> | Set Voltage. | Number |
| VOLT:SLEW <V/ms> | Volt slew rate. | Number |
| VOLT:PROT <OVP> | Set OVP. | Number |
| VOLT:PROT:STAT ON | OVP Enable. | None |
| VOLT:PROT:STAT OFF | OVP Disable. | None |
| Command | What it does | Arguments |
|---|---|---|
| CURR <Current> | Set Current. | Number |
| CURR:SLEW <Slew_rate> | Current slew rate. | Number |
| CURR:PROT <Over current> | Set OCP. | Number |
| CURR:PROT:STAT ON | OCP Enable. | None |
| CURR:PROT:STAT OFF | OCP Disable. | None |
| Command | What it does | Arguments |
|---|---|---|
| OUTP ON | Turn on. | None |
| OUTP OFF | Turn off. | None |
| OUTP? | Status. | None |
| Command | What it does | Arguments |
|---|---|---|
| MEAS:VOLT? | Measure volt. | None |
| MEAS:CURR? | Measure current. | None |
| MEASure:POWer? | Measure power. | None |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:ERRor? | Read errors. | None |
| SYSTem:<LOCal/REMote> | Sys remote. | Text: LOCal,REMote,RWLock |
| SYST:POS <State> | Sys POSetup. | Text: RST,Last,Last+Off |
| Command | What it does | Arguments |
|---|---|---|
| wait(<Ms>) | Wait. | Number |
| Command | What it does | Arguments |
|---|---|---|
| TRIG; | Trigger output. | None |
| Command | What it does | Arguments |
|---|---|---|
| *RST | Reset. | None |
| *CLS | Clear status. | None |
This reference is generated from TestFlow's instrument library, which is drafted from ITECH's programming documentation for the IT-M3140 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by ITECH's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The ITECH IT-M3140 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 23 SCPI commands for it: 5 queries that read values or state, and 18 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTP ON and MEAS:VOLT?.
MEAS:VOLT? (measure volt). The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the ITECH IT-M3140 through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.