Dynamic Load · SCPI command reference

Chroma 63102A SCPI commands

The Chroma 63102A dynamic load is controlled remotely with SCPI commands. TestFlow's instrument library holds 31 commands for it, 2 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the 63102A on a real bench.

Commands
31
Queries
2
Subsystems
11
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Chroma 63102A and writes the report from the measured results.

Get started

Control the Chroma 63102A from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Chroma 63102A's VISA address

# Paste the address of your Chroma 63102A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write(":CONFigure:REMote ON")  # Remote control
print(inst.query("MEAS:VOLT?"))  # Measure voltage

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Chroma 63102A and writes the report from the measured results.

Get started

Run a 63102A test without writing code

Describe the test in a sentence, for example “remote control on the 63102A, then measure voltage and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

31 commands in 11 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Current (CURRent) (10)

CommandWhat it doesArguments
CURR:STAT:L1 <Amp>Static Current low. Sets the static current lower valueNumber
CURR:STAT:L2 <Amp>Static Current High. Sets the static current higher value (Always set low and high)Number
CURR:STAT:RISE <Slew>Current rise slew. Sets the current rising slew rateNumber
CURR:STAT:FALL <Slew>Current fall slew. Sets the current falling slew rateNumber
CURR:DYN:L1 <Amp>DYN Current low. Sets the dynamic current lower valueNumber
CURR:DYN:L2 <Amp>DYN Current high. Sets the dynamic current higher valueNumber
CURR:DYN:T1 <Time>DYN Low time. Sets the period of low valueNumber
CURR:DYN:T2 <Time>DYN High time. Sets the period of high valueNumber
CURR:DYN:RISE <Slew>DYN Current rise. Sets the rise time for dynamic modeNumber
CURR:DYN:FALL <Slew>DYN Current fall. Sets the falling time for dynamic modeNumber

Voltage (VOLTage) (5)

CommandWhat it doesArguments
VOLT:L1 <Volt>VStatic voltage low. Sets the lower value of CV modeNumber
VOLT:L2 <Volt>VStatic voltave high. Sets the higher value of the CV modeNumber
VOLTage:CURRent <Amp>Static voltage current limit. Sets the current limitNumber
VOLT:MODE FASTVoltage fast. Sets voltage fast modeNone
VOLT:MODE SLOWVoltage slow. Sets voltage slow modeNone

RES subsystem (4)

CommandWhat it doesArguments
RES:L1 <OHM> OHMResistance low. Sets the lower value of dynamic resistive loadNumber
RES:L2 <OHM> OHMResistance high. Sets the higher value of dynamic resistive load (Set low and high for constant)Number
RES:RISE <Slew>Resistance rise. Sets resistive load riseNumber
RES:FALL <Slew>Resistance fall. Sets resistive load fallNumber

Configure (CONFigure) (3)

CommandWhat it doesArguments
:CONFigure:REMote ONRemote control. Sets control to remoteNone
CONF:VOLT:LATC ONVoltage latch ON. Enables voltage latchNone
CONF:VOLT:LATC OFFVoltage latch OFF. Disables voltage latchNone

LOAD subsystem (2)

CommandWhat it doesArguments
LOAD 1Turn On. Turns the load onNone
LOAD 0Turn Off. Turns the load offNone

Measurement (MEASure) (2)

CommandWhat it doesArguments
MEAS:VOLT?Measure voltage. Measures the voltageNone
MEAS:CURR?Measure current. Measures the currentNone

MODE subsystem (1)

CommandWhat it doesArguments
MODE <Mode>Mode. Sets the load modeText: CRH,CRL,CCH,CCL,CCDL,CCDH,CV

Channels (CHANnel) (1)

CommandWhat it doesArguments
CHANnel <Channel>Channel select. Selects the channelNumber: 1,2,3,4,5,6,7,8

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last mearurment to a variableText

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Chroma's programming documentation for the 63102A and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Chroma's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Chroma 63102A support SCPI remote control?

Yes. The Chroma 63102A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 31 SCPI commands for it: 2 queries that read values or state, and 29 settings and actions.

How do I control the Chroma 63102A from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, :CONFigure:REMote ON and MEAS:VOLT?.

Which command reads a value from the Chroma 63102A?

MEAS:VOLT? (measure voltage). Measures the voltage The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Chroma 63102A without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Chroma 63102A through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today