The B&K Precision 5492B multimeter is controlled remotely with SCPI commands. TestFlow's instrument library holds 52 commands for it, 16 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the 5492B on a real bench.
Commands
52
Queries
16
Subsystems
13
Models covered
1
Run this on your bench
Describe the test; TestFlow's agent uses this command set to drive your B&K Precision 5492B and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
Describe the test in a sentence, for example “func dcv on the 5492B, then measure dcv and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
Set Rel Offset. Sets the reference value used by the relative (null) operation.
Text: VOLTage:DC,VOLTage:AC,CURRent:DC,CURRent:AC,RESistance,FRESistance,FREQuency,PERiod; Number
<Output Variable>=<Equation>
Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)
Number; Text
Calculate (CALCulate) (5)
Command
What it does
Arguments
CALCulate2:STATe ON
MinMax On. Enables the min/max/average statistics operation.
None
CALCulate2:STATe OFF
MinMax Off. Disables the min/max/average statistics operation.
None
CALCulate2:FORMat MINimum;:CALCulate2:DATA?
Read Min. Returns the minimum of the collected statistics.
None
CALCulate2:FORMat MAXimum;:CALCulate2:DATA?
Read Max. Returns the maximum of the collected statistics.
None
CALCulate2:FORMat MEAN;:CALCulate2:DATA?
Read Average. Returns the average of the collected statistics.
None
UNIT subsystem (4)
Command
What it does
Arguments
UNIT:VOLTage:AC DB
DB On. Enables the dB math operation.
None
UNIT:VOLTage:AC V
DB Off. Disables the dB math operation.
None
UNIT:VOLTage:AC DBM
DBm On. Enables the dBm math operation.
None
UNIT:VOLTage:AC:DBM:IMPedance <Impedance>
Set dBm Reference. Sets the dBm reference resistance in ohms.
Number: 1-9999
Read (READ) (1)
Command
What it does
Arguments
READ?
Read Value. Triggers and returns one new measurement of the active function.
None
Fetch (FETCh) (1)
Command
What it does
Arguments
FETCh?
Fetch Value. Returns the last measurement without re-triggering.
None
Trigger (TRIGger) (1)
Command
What it does
Arguments
:TRIGger:SOURce <Source>
Set Trigger Source. Sets the trigger source.
Text: IMMediate,EXTernal,BUS
Initiate (INITiate) (1)
Command
What it does
Arguments
:INITiate
Init Trigger. Places the meter in the wait-for-trigger state.
None
WAIT subsystem (1)
Command
What it does
Arguments
wait(<ms>)
Wait. Waits for number of milliseconds
Number
SAVE subsystem (1)
Command
What it does
Arguments
save2var <Variable_name>
Save2Variable. Saves last measurement to a variable
Text
IEEE 488.2 common commands (3)
Command
What it does
Arguments
*IDN?
Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).
None
*RST
Reset. Resets the instrument to its default state.
None
*TRG
Trigger Bus. Generates a bus trigger when the instrument is in wait-for-trigger state.
None
Where these commands come from
This reference is generated from TestFlow's instrument library, which is drafted from B&K Precision's programming documentation for the 5492B and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by B&K Precision's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Frequently asked questions
Does the B&K Precision 5492B support SCPI remote control?
Yes. The B&K Precision 5492B accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 52 SCPI commands for it: 16 queries that read values or state, and 36 settings and actions.
How do I control the B&K Precision 5492B from Python?
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, FUNCtion "VOLT:DC" and MEASure:VOLTage:DC?.
Which command reads a value from the B&K Precision 5492B?
MEASure:VOLTage:DC? (measure dcv). Configures DC voltage and returns one measured value in volts. The full list of queries is in the command reference on this page, grouped by subsystem.
Can I automate the B&K Precision 5492B without writing code?
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the B&K Precision 5492B through the TestFlow desktop app, and writes the report from the measured results.
Your next test, automated today