The B&K Precision 4079B and 4080B function generator is controlled remotely with SCPI commands. TestFlow's instrument library holds 38 commands for it, 5 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the 4079B on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your B&K Precision 4079B or 4080B and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the B&K Precision 4079B's VISA address
# Paste the address of your B&K Precision 4079B (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write(":OUTPut1:STATe ON") # Turn On Output
print(inst.query("*TST?")) # Self Test
inst.close()Describe the test; TestFlow's agent uses this command set to drive your B&K Precision 4079B or 4080B and writes the report from the measured results.
Describe the test in a sentence, for example “turn on output on the 4079B, then self test and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
38 commands in 7 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values. The 4079B and 4080B share this command set in TestFlow's library.
| Command | What it does | Arguments |
|---|---|---|
| :SOURce<Channel>:FUNCtion <Shape> | Set Function. Sets the basic waveform type for the selected channel. | Number: 1,2; Text: SINusoid,SQUare,TRIangle,ARBitrary,PULSe |
| :SOURce<Channel>:FREQuency <Freq> | Set Frequency. Sets the output frequency in Hz for the selected channel. | Number: 1,2; Number |
| :SOURce<Channel>:VOLTage:AMPLitude <Vpp> | Set Amplitude. Sets the output amplitude (Vpp) for the selected channel. | Number: 1,2; Number: 0.01-10 |
| :SOURce<Channel>:VOLTage:OFFSet <Volt> | Set Voltage Offset. Sets the DC offset voltage for the selected channel. | Number: 1,2; Number: 0.01-4.99 |
| :SOURce<Channel>:PHASe <Deg> | Set Phase. Sets the output phase in degrees for the selected channel. | Number: 1,2; Number: -180-180 |
| :SOURce<Channel>:DCYCle <Pct> | Set Square Duty Cycle. Sets the square/pulse duty cycle percentage for the selected channel. | Number: 1,2; Number: 1-100 |
| :SOURce<Channel>:PULSe:WIDth <Sec> | Set Pulse Width. Sets the pulse width in seconds for the selected channel. | Number: 1,2; Number |
| :SOURce<Channel>:PULSe:RISe <Sec> | Set Pulse Rise. Sets the pulse rise time for the selected channel. | Number: 1,2; Number |
| :SOURce<Channel>:PULSe:FALl <Sec> | Set Pulse Fall. Sets the pulse fall time for the selected channel. | Number: 1,2; Number |
| :SOURce<Channel>:AM:DEPTh <Pct> | Set AM Depth. Sets the AM depth percentage for the selected channel. | Number: 1,2; Number: 0-100 |
| :SOURce<Channel>:AM:FREQuency <Freq> | Set AM Freq. Sets the AM modulating frequency for the selected channel. | Number: 1,2; Number |
| :SOURce<Channel>:FM:DEViation <Freq> | Set FM Deviation. Sets the FM frequency deviation for the selected channel. | Number: 1,2; Number |
| :SOURce<Channel>:FM:FREQuency <Freq> | Set FM Freq. Sets the FM modulating frequency for the selected channel. | Number: 1,2; Number |
| :SOURce<Channel>:FSK:HIFrequency <Freq> | Set FSK Hop Freq. Sets the FSK hop frequency for the selected channel. | Number: 1,2; Number |
| :SOURce<Channel>:SWEep:STATe ON | Enable Sweep. Enables the frequency sweep on the selected channel. | Number: 1,2 |
| :SOURce<Channel>:SWEep:STATe OFF | Disable Sweep. Disables the frequency sweep on the selected channel. | Number: 1,2 |
| :SOURce<Channel>:SWEep:TIME <Sec> | Set Sweep Time. Sets the sweep time in seconds for the selected channel. | Number: 1,2; Number |
| :SOURce<Channel>:SWEep:STARt <Freq> | Set Sweep Start Freq. Sets the sweep start frequency for the selected channel. | Number: 1,2; Number |
| :SOURce<Channel>:SWEep:STOP <Freq> | Set Sweep Stop Freq. Sets the sweep stop frequency for the selected channel. | Number: 1,2; Number |
| :SOURce<Channel>:SWEep:SPACing <Type> | Set Sweep Spacing. Sets the sweep spacing (linear/log) for the selected channel. | Number: 1,2; Text: LIN,LOG |
| Command | What it does | Arguments |
|---|---|---|
| :OUTPut<Channel>:STATe ON | Turn On Output. Enables the selected channel output. | Number: 1,2 |
| :OUTPut<Channel>:STATe OFF | Turn Off Output. Disables the selected channel output. | Number: 1,2 |
| :OUTPut<Channel>:STATe? | Read Output State. Reads the selected channel output state and settings. | Number: 1,2 |
| :OUTPut<Channel>:TERMinator OFF | Set Output Load HighZ. Sets the selected channel output load to high-impedance. | Number: 1,2 |
| Command | What it does | Arguments |
|---|---|---|
| :TRIGger<Channel>:BURSt <N> | Set Burst Cycles. Sets the number of cycles per burst for the selected channel. | Number: 1,2; Number: 2-999999 |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). | None |
| *RST | Reset. Resets the instrument to its default state. | None |
| *CLS | Clear Status. Clears all event registers and the error queue. | None |
| *TST? | Self Test. Runs the self-test and returns 0 for pass. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *WAI | Wait To Continue. Waits until all pending operations are complete. | None |
| *TRG | Trigger Bus. Generates a bus trigger. | None |
| *SAV <Slot> | Save State Slot. Stores the current state to a memory slot. | Number |
| *RCL <Slot> | Recall State Slot. Recalls a state from a memory slot. | Number |
| *OPT? | Read Options. Queries the installed options. | None |
This reference is generated from TestFlow's instrument library, which is drafted from B&K Precision's programming documentation for the 4079B and 4080B and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by B&K Precision's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The B&K Precision 4079B accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 38 SCPI commands for it: 5 queries that read values or state, and 33 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, :OUTPut1:STATe ON and *TST?.
*TST? (self test). Runs the self-test and returns 0 for pass. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the B&K Precision 4079B through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.