The Tektronix TTR503A and TTR506A vector network analyzer is controlled remotely with SCPI commands. TestFlow's instrument library holds 47 commands for it, 6 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the TTR503A on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Tektronix TTR503A or TTR506A and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Tektronix TTR503A's VISA address
# Paste the address of your Tektronix TTR503A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("OUTPut:STATe 1") # RF Power On
print(inst.query("CALCulate:SELected:DATA:FDATa?")) # Read Formatted Data
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Tektronix TTR503A or TTR506A and writes the report from the measured results.
Describe the test in a sentence, for example “rf power on on the TTR503A, then read formatted data and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
47 commands in 14 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values. The TTR503A and TTR506A share this command set in TestFlow's library.
| Command | What it does | Arguments |
|---|---|---|
| SENSe:FREQuency:STARt <Frequency> | Set Start Freq. Sets the sweep start frequency in Hz. | Number |
| SENSe:FREQuency:STOP <Frequency> | Set Stop Freq. Sets the sweep stop frequency in Hz. | Number |
| SENSe:FREQuency:CENTer <Frequency> | Set Center Freq. Sets the sweep center frequency in Hz. | Number |
| SENSe:FREQuency:SPAN <Frequency> | Set Span Freq. Sets the sweep frequency span in Hz. | Number |
| SENSe:FREQuency:CW <Frequency> | Set CW Freq. Sets the CW (fixed) frequency in Hz. | Number |
| SENSe:SWEep:POINts <Points> | Set Points. Sets the number of measurement points per sweep. | Number |
| SENSe:SWEep:TYPE <Type> | Set Sweep Type. Sets the sweep type. | Text: LINear,LOGarithmic,SEGMent,POWer |
| SENSe:BANDwidth:RESolution <Bandwidth> | Set IF Bandwidth. Sets the IF bandwidth in Hz. | Number |
| SENSe:AVERage:STATe 1 | Average On. Enables trace averaging. | None |
| SENSe:AVERage:STATe 0 | Average Off. Disables trace averaging. | None |
| SENSe:AVERage:COUNt <Count> | Set Average Count. Sets the number of sweeps to average. | Number |
| SENSe:AVERage:CLEar | Average Clear. Restarts (clears) the averaging measurement. | None |
| SENSe:CORRection:STATe 1 | Correction On. Turns measurement error correction (calibration) on. | None |
| SENSe:CORRection:STATe 0 | Correction Off. Turns measurement error correction (calibration) off. | None |
| Command | What it does | Arguments |
|---|---|---|
| CALCulate:PARameter:COUNt <Count> | Set Param Count. Sets the number of measurement parameters (traces) for the channel. | Number |
| CALCulate:PARameter<Trace>:DEFine <Parameter> | Define Measurement. Assigns an S-parameter to the specified trace. | Number: 1,2,3,4; Text: S11,S12,S21,S22 |
| CALCulate:SELected:FORMat <Format> | Set Format. Sets the display/data format of the selected trace. | Text: MLOGarithmic,MLINear,PHASe,GDELay,SMITh,SLINear,SLOGarithmic,SCOMplex,SADMittance,SWR,REAL,IMAGinary |
| CALCulate:SELected:DATA:FDATa? | Read Formatted Data. Returns the formatted trace data array of the selected trace. | None |
| CALCulate:SELected:DATA:SDATa? | Read Complex Data. Returns the complex (real/imag) trace data of the selected trace. | None |
| CALCulate:SELected:MARKer<Marker>:STATe 1 | Marker On. Turns on the specified marker on the selected trace. | Number: 1,2,3,4,5,6,7,8 |
| CALCulate:SELected:MARKer<Marker>:STATe 0 | Marker Off. Turns off the specified marker on the selected trace. | Number: 1,2,3,4,5,6,7,8 |
| CALCulate:SELected:MARKer<Marker>:X <Frequency> | Set Marker X. Sets the marker stimulus position in Hz. | Number: 1,2,3,4,5,6,7,8; Number |
| CALCulate:SELected:MARKer<Marker>:Y? | Read Marker Y. Returns the marker response value. | Number: 1,2,3,4,5,6,7,8 |
| CALCulate:SELected:MARKer<Marker>:FUNCtion:TYPE MAXimum ; CALCulate:SELected:MARKer<Marker>:FUNCtion:EXECute | Marker Search Max. Moves the marker to the trace maximum. | Number: 1,2,3,4,5,6,7,8 |
| CALCulate:SELected:MARKer<Marker>:FUNCtion:TYPE MINimum ; CALCulate:SELected:MARKer<Marker>:FUNCtion:EXECute | Marker Search Min. Moves the marker to the trace minimum. | Number: 1,2,3,4,5,6,7,8 |
| Command | What it does | Arguments |
|---|---|---|
| INITiate:CONTinuous 1 | Continuous On. Enables continuous (free-run) triggering. | None |
| INITiate:CONTinuous 0 | Continuous Off. Disables continuous triggering (hold/single mode). | None |
| INITiate:IMMediate | Trigger Single. Triggers a single sweep when not in continuous mode. | None |
| Command | What it does | Arguments |
|---|---|---|
| DISPlay:CHANnel:TRACe:Y:SCALe:AUTO | Autoscale. Autoscales the selected trace to fit the display. | None |
| DISPlay:ENABle 1 | Display Enable. Enables display updates. | None |
| DISPlay:ENABle 0 | Display Disable. Disables display updates to speed up remote measurements. | None |
| Command | What it does | Arguments |
|---|---|---|
| OUTPut:STATe 1 | RF Power On. Turns the RF source power output on. | None |
| OUTPut:STATe 0 | RF Power Off. Turns the RF source power output off. | None |
| Command | What it does | Arguments |
|---|---|---|
| MMEMory:STORe '<Filename>' | Save State. Saves the instrument state to the named file. | Text |
| MMEMory:LOAD '<Filename>' | Recall State. Recalls an instrument state from the named file. | Text |
| Command | What it does | Arguments |
|---|---|---|
| SOURce:POWer:LEVel <Power> | Set Power Level. Sets the source output power level in dBm. | Number |
| Command | What it does | Arguments |
|---|---|---|
| TRIGger:SOURce <Source> | Set Trigger Source. Sets the trigger source for the sweep. | Text: INTernal,EXTernal,MANual,BUS |
| Command | What it does | Arguments |
|---|---|---|
| ABORt | Abort. Resets the trigger system and stops the current measurement. | None |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:ERRor? | Read Error. Reads the next message from the error queue. | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *RST | Preset. Presets the analyzer to its default measurement state. | None |
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). | None |
| *CLS | Clear Status. Clears all event registers and the error queue. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *WAI | Wait To Continue. Waits until all pending operations are complete before continuing. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Tektronix's programming documentation for the TTR503A and TTR506A and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Tektronix's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The Tektronix TTR503A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 47 SCPI commands for it: 6 queries that read values or state, and 41 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut:STATe 1 and CALCulate:SELected:DATA:FDATa?.
CALCulate:SELected:DATA:FDATa? (read formatted data). Returns the formatted trace data array of the selected trace. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Tektronix TTR503A through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.