Oscilloscope · SCPI command reference

Tektronix MDO34 SCPI commands

The Tektronix MDO34 oscilloscope is controlled remotely with SCPI commands. TestFlow's instrument library holds 66 commands for it, 19 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the MDO34 on a real bench.

Commands
66
Queries
19
Subsystems
14
Models covered
1

Control the Tektronix MDO34 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Tektronix MDO34's VISA address

# Paste the address of your Tektronix MDO34 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("ACQuire:STOPAfter RUNSTop ;STATE RUN ;:DISplay:PERSistence Auto")  # RUN
print(inst.query("RF:MEASUre:ACPR:LA1DB?"))  # RF Cent2 low Side1

inst.close()

Run a MDO34 test without writing code

Describe the test in a sentence, for example “run on the MDO34, then rf cent2 low side1 and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

66 commands in 14 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

RF subsystem (31)

CommandWhat it doesArguments
RF:CLIPPing?RF:CLIPPing. Queries whether the RF input/measurement is clipping/overloading (signal level too high for valid measurement).None
RF:DETECTionmethod:MODe <AUTO,MANual>RF detect mode. Sets RF detector selection to automatic or manual (who chooses detector behavior: scope or user).Text: AUTO,MANual
RF:DETECTionmethod:RF_<> <>RF Timeout. Selects RF detection/trace behavior (e.g., normal/average/max hold/min hold) and detector type (sample/average/peak).Text: AVErage,MAXHold,MINHold,NORMal; Text: PLUSpeak,MINUSpeak,SAMple,AVErage
RF:FREQuency <Frequency_center>RF freq center. Sets the RF analysis center frequency.Number
RF:POSition <RF_position>RF position. Adjusts vertical display position/offset of the RF trace on the screen.Number: 10,9,8,7,6,5,4,3,2,1,0,-1,-2,-3,-4,-5,-6,-7,-8,-9,-10
RF:REFLevel <RF_level>RF Level. Sets RF reference level to AUTO (instrument automatically scales reference level).Text: AUTO
RF:LABel "<RF_label>"RF Label. Adds/sets a custom label for the RF measurement/trace display.Text
RF:MEASUre:ACPR:ADJACENTPAIRs <Pairs>RF ADJ Pairs. Sets how many adjacent channel pairs are used in ACPR measurement (1st, 2nd, 3rd adjacents).Text: 1,2,3
RF:MEASUre:ACPR:CHANBW <Bandwidth>RF bandwidth. Sets the channel bandwidth used for ACPR measurement integration.Number
RF:MEASUre:ACPR:CHANSPACing <Center to Center spacing>RF spacing. Sets center-to-center channel spacing for ACPR (defines adjacent channel offsets).Number
RF:MEASUre:ACPR:LA1DB?RF Cent2 low Side1. Queries ACPR result for lower adjacent channel 1 relative to carrier (in dB).None
RF:MEASUre:ACPR:LA2DB?RF Cent2 low Side2. Queries ACPR result for lower adjacent channel 2 (in dB).None
RF:MEASUre:ACPR:LA3DB?RF Cent2 low Side3. Queries ACPR result for lower adjacent channel 3 (in dB).None
RF:MEASUre:ACPR:UA1DB?RF Cent2 Up Side1. Queries ACPR result for upper adjacent channel 1 (in dB).None
RF:MEASUre:ACPR:UA2DB?RF Cent2 Up Side2. Queries ACPR result for upper adjacent channel 2 (in dB).None
RF:MEASUre:ACPR:UA3DB?RF Cent2 Up Side2. Queries ACPR result for upper adjacent channel 3 (in dB).None
RF:MEASUre:TYPe <Measure_type>RF measure type. Selects which RF measurement application is active: Channel Power (CP), ACPR, or Occupied BW (OBW).Text: NONe,CP,ACPR,OBW
RF:MEASUre:<Mode>:POWer?RF measure power. Reads the measured power result for the selected RF measurement mode.Text: CP,ACPR,OBW
RF:MEASUre:<Mode>:CHANBW?RF measure BW. Reads the configured/measured channel bandwidth parameter for the selected RF mode.Text: CP,ACPR,OBW
RF:MEASUre:OBW:LOWERFreq?RF measure Low Freq. Queries the lower frequency edge of occupied bandwidth measurement.None
RF:MEASUre:OBW:UPPERFreq?RF measure Up Freq. Queries the upper frequency edge of occupied bandwidth measurement.None
RF:PRObe:AUTOZero EXECuteRF AUTO Zero. Performs RF probe auto-zero calibration to reduce offset and measurement error.None
RF:PRObe:DEGAUss EXECuteRF Probe Degauss. Runs RF probe degauss cycle (reduces hysteresis/magnetization effects in the probe).None
RF:PRObe:PREAmp:MODe <BYPass,AUTO>RF Probe mode. Sets RF probe preamp mode: bypass preamp or automatically control it.Text: BYPass,AUTO
RF:REFLevel <Level>RF Ref Level. Sets the RF reference level (here using AUTO so instrument scales for best dynamic range).Text: AUTO
RF:SCAle <Scale>RF Scale. Sets RF display amplitude scale (e.g., dB/div depending on units/mode).Number
RF:SPAN <SPAN>RF SPAN. Sets the frequency span around center frequency for RF analysis.Number
RF:STARt <Start_frequency>RF Start Freq. Sets the start frequency for the RF spectrum/analysis view.Number
RF:STOP <Stop_frequency>RF Stop Freq. Sets the stop frequency for the RF spectrum/analysis view.Number
RF:UNIts <Units>RF Units. Sets RF amplitude units (power, voltage-referenced dB, or current-referenced dB).Text: DBM,DBUW,DBMV,DBUV,DBMA,DBUA
RF:WINdow <Window>RF Window. Selects FFT/windowing function to control spectral leakage vs amplitude accuracy.Text: RECTangular,HAMming,HANning,BLAckmanharris,KAIser,FLATtop

CURS subsystem (8)

CommandWhat it doesArguments
CURSor:SOUrce <Channel>Cursor channel. Assigns cursor measurements to operate on a specific channel waveform.Text: CH1,CH2,CH3,CH4
CURSor:MODe <Mode>Cursor mode. Sets whether cursors move independently or as a coupled pair (dependent tracking).Text: TRACk,INDependent
CURSor:FUNCtion WAVEFORMCursers ON. Enables waveform cursors mode so delta time/voltage can be read using cursor functions.None
CURSor:FUNCtion OFFCursers OFF. Disables cursor functionality (no cursor readouts active).None
CURSor:DDT?Cursers dV/dT. Returns the computed slope (ΔV/ΔT) based on current cursor positions.None
CURSor:VBArs:DELTa?Cursor dT. Returns time delta (ΔT) between vertical bar cursors (timing cursors).None
CURSor:HBArs:DELTa?Cursor dV. Returns voltage delta (ΔV) between horizontal bar cursors (amplitude cursors).None
CURSor:HBArs:POSITION<Position>?Cursor voltage. Reads the current voltage position of a specified horizontal cursor bar.Number: 1,2

MEASU subsystem (5)

CommandWhat it doesArguments
MEASUrement:IMMed:SOUrce <Channel> ; MEASUrement:IMMed:TYPe <Measurement> ; MEASUrement:IMMed:VALue?Measurement. Configures the immediate measurement (source + type) and then queries the current numeric result.Text: CH1,CH2,CH3,CH4; Text: AMPlitude,RMS,PK2Pk,FREQuency,HIGH,LOW,MAXimum,MEAN,MEDian,MINImum,NDUty,PDUty,NOVershoot,NWIdth,PERIod,POVershoot,PWIdth,RISe,FALL
MEASUrement:IMMed:SOUrce <Channel> ; MEASUrement:IMMed:VALue?Measurement Channel. Sets the measurement source channel (and often immediately reads the current value based on the already-selected measurement type).Text: CH1,CH2,CH3,CH4
MEASUrement:IMMed:TYPe <Measurement>Measurement Type. Selects what measurement algorithm to compute for the “immediate measurement” engine.Text: AMPlitude,RMS,PK2Pk,FREQuency,HIGH,LOW,MAXimum,MEAN,MEDian,MINImum,NDUty,PDUty,NOVershoot,NWIdth,PERIod,POVershoot,PWIdth,RISe,FALL
MEASUrement:IMMed:VALue?Measure. Reads the numeric value of the currently configured immediate measurement (source + type).None
MEASUrement:IMMed:DELay:EDGE1 <Edge> ; MEASUrement:IMMed:SOUrce1 <Source_1> ; MEASUrement:IMMed:SOUrce2 <Source_2> ; MEASUrement:IMMed:DELay:EDGE2 <Edge>Measure delay. Configures a delay measurement between Source1 and Source2 using specified edge direction (rise/fall).Text: FALL,RISe; Text: CH1,CH2,CH3,CH4; Text: CH1,CH2,CH3,CH4

Acquisition (ACQuire) (4)

CommandWhat it doesArguments
ACQuire:STOPAfter SEQuence ;STATE RUNSingle seq. Arms the scope to acquire one sequence and then stop automatically (single-shot capture).None
ACQuire:STOPAfter RUNSTop ;STATE RUN ;:DISplay:PERSistence AutoRUN. Starts continuous acquisition and sets display persistence to Auto so older traces fade automatically.None
ACQuire:STOPAfter RUNSTop ;STATE Stop ;:DISplay:PERSistence AutoSTOP. Stops acquisition (freezes waveform updates) while keeping persistence mode configured as Auto.None
ACQuire:STOPAfter RUNSTop ;STATE Stop ;:DISplay:PERSistence INFIniteINFInite. Stops acquisition and sets Infinite persistence (accumulates traces without fading).None

Other subsystem (4)

CommandWhat it doesArguments
<Channel>:LABel "<Text>"Chan label. Sets a custom label string for the selected analog channel (shown on UI and screenshots).Text: CH1,CH2,CH3,CH4; Text
<Channel>:POSition <Position>Channel position. Moves the channel waveform vertically (display offset in divisions).Text: CH1,CH2,CH3,CH4; Number: 5,4,3,2,1,0,-1,-2,-3,-4,-5
<Channel>:SCALE <Scale>Channel scale. Sets the channel vertical scale (Volts/div), changing waveform amplitude scaling.Text: CH1,CH2,CH3,CH4; Number
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

Trigger (TRIGger) (3)

CommandWhat it doesArguments
TRIGger:A:EDGE:SLOpe <Slope>Trigget slope. Chooses the edge direction that triggers (rising, falling, or either).Text: RISe,FALL,EITHer
TRIGger:A:EDGE:COUPling <Coupling>Trigger coupling. Sets trigger coupling/filtering to reduce false triggers (AC coupling, HF/LF reject, noise reject).Text: DC,AC,HFRej,LFRej,NOISErej
TRIGger:A:LEVel:<Channel> <Volt>Trigger level. Sets the trigger threshold voltage for the chosen trigger channel.Text: CH1,CH2,CH3,CH4; Number

SEL subsystem (3)

CommandWhat it doesArguments
SELect:<Channel> ONShow channel. Turns ON display of the selected channel waveform.Text: CH1,CH2,CH3,CH4
SELect:<Channel> OFFHide channel. Turns OFF display of the selected channel waveform (channel still exists but is hidden).Text: CH1,CH2,CH3,CH4
SELect:RF_<Mode> <ON/OFF>RF Display. Enables/disables RF display trace for a specific detector/trace mode (avg/maxhold/minhold/normal).Text: AVErage,MAXHold,MINHold,NORMal; Text: ON,OFF

HORIZONTAL subsystem (2)

CommandWhat it doesArguments
HORIZONTAL:POSITION <Position>Time position. Shifts the waveform horizontally relative to the trigger position (pre/post-trigger view).Number
HORIZONTAL:SCALE <Scale>Time scale. Sets the timebase scale (Seconds/div), zooming in/out in time.Number

TRIGGER subsystem (1)

CommandWhat it doesArguments
TRIGGER:A:EDGE:SOURCE <Channel>Trigger channel. Selects which analog channel is used as the edge trigger source.Text: CH1,CH2,CH3,CH4

H subsystem (1)

CommandWhat it doesArguments
Hardcopy:Layout Landscape ; SAVe:IMAGe:INKSaver ON ; SAVe:IMAGe:FILEFormat PNGCapture. Takes a PNG screenshot, saves it temporarily, waits for file creation, reads the PNG back to the controller, then deletes the temp file.None

S subsystem (1)

CommandWhat it doesArguments
Set?Get settings. Queries the instrument for its current setup / configuration string (used to restore or log state).None

ROS subsystem (1)

CommandWhat it doesArguments
ROSc:SOUrce <Source>Oscilator source. Selects reference oscillator source: internal timebase or external reference input for better frequency accuracy/locking.Text: INTERnal,EXTernal

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last mearurment to a variableText

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Tektronix's programming documentation for the MDO34 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Tektronix's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Tektronix MDO34 support SCPI remote control?

Yes. The Tektronix MDO34 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 66 SCPI commands for it: 19 queries that read values or state, and 47 settings and actions.

How do I control the Tektronix MDO34 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, ACQuire:STOPAfter RUNSTop ;STATE RUN ;:DISplay:PERSistence Auto and RF:MEASUre:ACPR:LA1DB?.

Which command reads a value from the Tektronix MDO34?

RF:MEASUre:ACPR:LA1DB? (rf cent2 low side1). Queries ACPR result for lower adjacent channel 1 relative to carrier (in dB). The full list of queries is in the command reference on this page, grouped by subsystem.