The Tabor Electronics WW1074 function generator is controlled remotely with SCPI commands. TestFlow's instrument library holds 32 commands for it, 8 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the WW1074 on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Tabor Electronics WW1074 and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Tabor Electronics WW1074's VISA address
# Paste the address of your Tabor Electronics WW1074 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("TRIGger:IMMediate") # Trigger Now
print(inst.query("SYSTem:ERRor?")) # Read Error
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Tabor Electronics WW1074 and writes the report from the measured results.
Describe the test in a sentence, for example “trigger now on the WW1074, then read error and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
32 commands in 7 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| INSTrument:SELect <Channel> ; OUTPut ON | Turn On Output. Enables the selected channel output. | Number: 1,2,3,4 |
| INSTrument:SELect <Channel> ; OUTPut OFF | Turn Off Output. Disables the selected channel output. | Number: 1,2,3,4 |
| INSTrument:SELect <Channel> ; OUTPut? | Read Output State. Reads the selected channel output state. | Number: 1,2,3,4 |
| INSTrument:SELect <Channel> ; OUTPut:LOAD <Ohm> | Set Output Load. Sets the selected channel output load in ohms; use INFinity for high-Z. | Number: 1,2,3,4; Number: 50-1000000 |
| INSTrument:SELect <Channel> ; FUNCtion:SHAPe <Shape> | Set Function. Sets the output waveform shape for the selected channel. | Number: 1,2,3,4; Text: SINusoid,TRIangle,SQUare,PULSe,RAMP,SINC,GAUSsian,EXPonential,NOISe,DC |
| INSTrument:SELect <Channel> ; FUNCtion:SHAPe? | Read Function. Reads the output waveform shape for the selected channel. | Number: 1,2,3,4 |
| INSTrument:SELect <Channel> ; FREQuency <Freq> | Set Frequency. Sets the output frequency in Hz for the selected channel. | Number: 1,2,3,4; Number |
| INSTrument:SELect <Channel> ; FREQuency? | Read Frequency. Reads the output frequency for the selected channel. | Number: 1,2,3,4 |
| INSTrument:SELect <Channel> ; VOLTage <Amp> | Set Amplitude. Sets the output amplitude (Vpp) for the selected channel. | Number: 1,2,3,4; Number |
| INSTrument:SELect <Channel> ; VOLTage? | Read Amplitude. Reads the output amplitude for the selected channel. | Number: 1,2,3,4 |
| INSTrument:SELect <Channel> ; VOLTage:OFFSet <Volt> | Set Voltage Offset. Sets the DC offset voltage for the selected channel. | Number: 1,2,3,4; Number |
| INSTrument:SELect <Channel> ; VOLTage:OFFSet? | Read Voltage Offset. Reads the DC offset voltage for the selected channel. | Number: 1,2,3,4 |
| INSTrument:SELect <Channel> ; SINusoid:PHASe <Deg> | Set Phase. Sets the output phase in degrees for the selected channel. | Number: 1,2,3,4; Number: 0-360 |
| INSTrument:SELect <Channel> ; SQUare:DCYCle <Pct> | Set Square Duty Cycle. Sets the square-wave duty cycle for the selected channel. | Number: 1,2,3,4; Number: 0-99.99 |
| INSTrument:SELect <Channel> ; PULSe:WIDth <Pct> | Set Pulse Width. Sets the pulse width in seconds for the selected channel. | Number: 1,2,3,4; Number: 0-99.999 |
| INSTrument:SELect <Channel> ; PULSe:TRANsition <Pct> | Set Pulse Edge. Sets the pulse edge transition time for the selected channel. | Number: 1,2,3,4; Number: 0-99.999 |
| INSTrument:SELect <Channel> ; FUNCtion:MODE USER ; TRACe:SELect <Segment> | Set Arb Waveform. Selects the arbitrary waveform for the selected channel. | Number: 1,2,3,4; Number: 1-10000 |
| INSTrument:SELect <Channel> ; TRIGger:BURSt ON | Enable Burst. Enables burst mode on the selected channel. | Number: 1,2,3,4 |
| INSTrument:SELect <Channel> ; TRIGger:BURSt OFF | Disable Burst. Disables burst mode on the selected channel. | Number: 1,2,3,4 |
| INSTrument:SELect <Channel> ; TRIGger:BURSt:COUNt <N> | Set Burst Cycles. Sets the number of cycles per burst for the selected channel. | Number: 1,2,3,4; Number: 1-1000000 |
| INSTrument:SELect <Channel> ; TRIGger:SOURce:ADVance <Src> | Set Trigger Source. Sets the trigger source. | Number: 1,2,3,4; Text: EXTernal,BUS,MIXed |
| Command | What it does | Arguments |
|---|---|---|
| TRIGger:IMMediate | Trigger Now. Issues an immediate trigger. | None |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:ERRor? | Read Error. Reads and clears the next error-queue entry. | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). | None |
| *RST | Reset. Resets the instrument to its default state. | None |
| *CLS | Clear Status. Clears all event registers and the error queue. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *WAI | Wait To Continue. Waits until all pending operations are complete. | None |
| *TRG | Trigger Bus. Generates a bus trigger. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Tabor Electronics's programming documentation for the WW1074 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Tabor Electronics's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The Tabor Electronics WW1074 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 32 SCPI commands for it: 8 queries that read values or state, and 24 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, TRIGger:IMMediate and SYSTem:ERRor?.
SYSTem:ERRor? (read error). Reads and clears the next error-queue entry. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Tabor Electronics WW1074 through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.