Function Generator · SCPI command reference

Tabor Electronics WW1074 SCPI commands

The Tabor Electronics WW1074 function generator is controlled remotely with SCPI commands. TestFlow's instrument library holds 32 commands for it, 8 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the WW1074 on a real bench.

Commands
32
Queries
8
Subsystems
7
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Tabor Electronics WW1074 and writes the report from the measured results.

Get started

Control the Tabor Electronics WW1074 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Tabor Electronics WW1074's VISA address

# Paste the address of your Tabor Electronics WW1074 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("TRIGger:IMMediate")  # Trigger Now
print(inst.query("SYSTem:ERRor?"))  # Read Error

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Tabor Electronics WW1074 and writes the report from the measured results.

Get started

Run a WW1074 test without writing code

Describe the test in a sentence, for example “trigger now on the WW1074, then read error and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

32 commands in 7 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Instrument (INSTrument) (21)

CommandWhat it doesArguments
INSTrument:SELect <Channel> ; OUTPut ONTurn On Output. Enables the selected channel output.Number: 1,2,3,4
INSTrument:SELect <Channel> ; OUTPut OFFTurn Off Output. Disables the selected channel output.Number: 1,2,3,4
INSTrument:SELect <Channel> ; OUTPut?Read Output State. Reads the selected channel output state.Number: 1,2,3,4
INSTrument:SELect <Channel> ; OUTPut:LOAD <Ohm>Set Output Load. Sets the selected channel output load in ohms; use INFinity for high-Z.Number: 1,2,3,4; Number: 50-1000000
INSTrument:SELect <Channel> ; FUNCtion:SHAPe <Shape>Set Function. Sets the output waveform shape for the selected channel.Number: 1,2,3,4; Text: SINusoid,TRIangle,SQUare,PULSe,RAMP,SINC,GAUSsian,EXPonential,NOISe,DC
INSTrument:SELect <Channel> ; FUNCtion:SHAPe?Read Function. Reads the output waveform shape for the selected channel.Number: 1,2,3,4
INSTrument:SELect <Channel> ; FREQuency <Freq>Set Frequency. Sets the output frequency in Hz for the selected channel.Number: 1,2,3,4; Number
INSTrument:SELect <Channel> ; FREQuency?Read Frequency. Reads the output frequency for the selected channel.Number: 1,2,3,4
INSTrument:SELect <Channel> ; VOLTage <Amp>Set Amplitude. Sets the output amplitude (Vpp) for the selected channel.Number: 1,2,3,4; Number
INSTrument:SELect <Channel> ; VOLTage?Read Amplitude. Reads the output amplitude for the selected channel.Number: 1,2,3,4
INSTrument:SELect <Channel> ; VOLTage:OFFSet <Volt>Set Voltage Offset. Sets the DC offset voltage for the selected channel.Number: 1,2,3,4; Number
INSTrument:SELect <Channel> ; VOLTage:OFFSet?Read Voltage Offset. Reads the DC offset voltage for the selected channel.Number: 1,2,3,4
INSTrument:SELect <Channel> ; SINusoid:PHASe <Deg>Set Phase. Sets the output phase in degrees for the selected channel.Number: 1,2,3,4; Number: 0-360
INSTrument:SELect <Channel> ; SQUare:DCYCle <Pct>Set Square Duty Cycle. Sets the square-wave duty cycle for the selected channel.Number: 1,2,3,4; Number: 0-99.99
INSTrument:SELect <Channel> ; PULSe:WIDth <Pct>Set Pulse Width. Sets the pulse width in seconds for the selected channel.Number: 1,2,3,4; Number: 0-99.999
INSTrument:SELect <Channel> ; PULSe:TRANsition <Pct>Set Pulse Edge. Sets the pulse edge transition time for the selected channel.Number: 1,2,3,4; Number: 0-99.999
INSTrument:SELect <Channel> ; FUNCtion:MODE USER ; TRACe:SELect <Segment>Set Arb Waveform. Selects the arbitrary waveform for the selected channel.Number: 1,2,3,4; Number: 1-10000
INSTrument:SELect <Channel> ; TRIGger:BURSt ONEnable Burst. Enables burst mode on the selected channel.Number: 1,2,3,4
INSTrument:SELect <Channel> ; TRIGger:BURSt OFFDisable Burst. Disables burst mode on the selected channel.Number: 1,2,3,4
INSTrument:SELect <Channel> ; TRIGger:BURSt:COUNt <N>Set Burst Cycles. Sets the number of cycles per burst for the selected channel.Number: 1,2,3,4; Number: 1-1000000
INSTrument:SELect <Channel> ; TRIGger:SOURce:ADVance <Src>Set Trigger Source. Sets the trigger source.Number: 1,2,3,4; Text: EXTernal,BUS,MIXed

Trigger (TRIGger) (1)

CommandWhat it doesArguments
TRIGger:IMMediateTrigger Now. Issues an immediate trigger.None

System (SYSTem) (1)

CommandWhat it doesArguments
SYSTem:ERRor?Read Error. Reads and clears the next error-queue entry.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (6)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete.None
*TRGTrigger Bus. Generates a bus trigger.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Tabor Electronics's programming documentation for the WW1074 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Tabor Electronics's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Tabor Electronics WW1074 support SCPI remote control?

Yes. The Tabor Electronics WW1074 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 32 SCPI commands for it: 8 queries that read values or state, and 24 settings and actions.

How do I control the Tabor Electronics WW1074 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, TRIGger:IMMediate and SYSTem:ERRor?.

Which command reads a value from the Tabor Electronics WW1074?

SYSTem:ERRor? (read error). Reads and clears the next error-queue entry. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Tabor Electronics WW1074 without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Tabor Electronics WW1074 through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.