The Tabor Electronics SE5082 function generator is controlled remotely with SCPI commands. TestFlow's instrument library holds 45 commands for it, 9 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the SE5082 on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Tabor Electronics SE5082 and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Tabor Electronics SE5082's VISA address
# Paste the address of your Tabor Electronics SE5082 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("TRIGger:IMMediate") # Trigger Now
print(inst.query("SYSTem:ERRor?")) # Read Error
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Tabor Electronics SE5082 and writes the report from the measured results.
Describe the test in a sentence, for example “trigger now on the SE5082, then read error and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
45 commands in 7 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| INSTrument:SELect 1 ; OUTPut ON | Turn On Output CH1. Enables channel 1 output. | None |
| INSTrument:SELect 1 ; OUTPut OFF | Turn Off Output CH1. Disables channel 1 output. | None |
| INSTrument:SELect 1 ; OUTPut? | Read Output State CH1. Reads channel 1 output state. | None |
| INSTrument:SELect 1 ; FUNCtion:SHAPe <Shape> | Set Function CH1. Sets the output waveform shape for channel 1. | Text: SINusoid,TRIangle,SQUare,RAMP,SINC,GAUSsian,EXPonential,NOISe,DC |
| INSTrument:SELect 1 ; FUNCtion:SHAPe? | Read Function CH1. Reads the output waveform shape for channel 1. | None |
| INSTrument:SELect 1 ; FREQuency <Freq> | Set Frequency CH1. Sets the output frequency in Hz for channel 1. | Number |
| INSTrument:SELect 1 ; FREQuency? | Read Frequency CH1. Reads the output frequency for channel 1. | None |
| INSTrument:SELect 1 ; VOLTage <Amp> | Set Amplitude CH1. Sets the output amplitude (Vpp) for channel 1. | Number |
| INSTrument:SELect 1 ; VOLTage? | Read Amplitude CH1. Reads the output amplitude for channel 1. | None |
| INSTrument:SELect 1 ; VOLTage:OFFSet <Volt> | Set Voltage Offset CH1. Sets the DC offset voltage for channel 1. | Number |
| INSTrument:SELect 1 ; VOLTage:OFFSet? | Read Voltage Offset CH1. Reads the DC offset voltage for channel 1. | None |
| INSTrument:SELect 1 ; SINusoid:PHASe <Deg> | Set Phase CH1. Sets the output phase in degrees for channel 1. | Number: -360-360 |
| INSTrument:SELect 1 ; SQUare:DCYCle <Pct> | Set Square Duty Cycle CH1. Sets the square-wave duty cycle for channel 1. | Number: 0-99.99 |
| INSTrument:SELect 1 ; PULSe:WIDTh <Sec> | Set Pulse Width CH1. Sets the pulse width in seconds for channel 1. | Number |
| INSTrument:SELect 1 ; PULSe:WIDTh:PERCent <Pct> | Set Pulse Duty Cycle CH1. Sets the pulse duty cycle for channel 1. | Number: 0.01-99.99 |
| INSTrument:SELect 1 ; PULSe:TRANsition <Sec> | Set Pulse Edge CH1. Sets the pulse edge transition time for channel 1. | Number |
| INSTrument:SELect 1 ; FUNCtion:MODE USER ; TRACe:SELect <Segment> | Set Arb Waveform CH1. Selects the arbitrary waveform for channel 1. | Number: 1-32000 |
| INSTrument:SELect 1 ; FUNCtion:MODE MODulation ; MODulation:TYPE AM | Enable AM CH1. Enables AM modulation on channel 1. | None |
| INSTrument:SELect 1 ; MODulation:TYPE OFF | Disable AM CH1. Disables AM modulation on channel 1. | None |
| INSTrument:SELect 1 ; AM:DEPTh <Pct> | Set AM Deviation CH1. Sets the AM depth percentage for channel 1. | Number: 0-200 |
| INSTrument:SELect 1 ; AM:INTernal:FREQuency <Freq> | Set AM Int Freq CH1. Sets the internal AM modulating frequency for channel 1. | Number |
| INSTrument:SELect 1 ; FUNCtion:MODE MODulation ; MODulation:TYPE FM | Enable FM CH1. Enables FM modulation on channel 1. | None |
| INSTrument:SELect 1 ; FM:DEViation <Freq> | Set FM Deviation CH1. Sets the FM frequency deviation for channel 1. | Number |
| INSTrument:SELect 1 ; FM:FREQuency <Freq> | Set FM Int Freq CH1. Sets the internal FM modulating frequency for channel 1. | Number |
| INSTrument:SELect 1 ; FUNCtion:MODE MODulation ; MODulation:TYPE FSK | Enable FSK CH1. Enables FSK modulation on channel 1. | None |
| INSTrument:SELect 1 ; FSK:FREQuency:SHIFted <Freq> | Set FSK Hop Freq CH1. Sets the FSK hop frequency for channel 1. | Number |
| INSTrument:SELect 1 ; FUNCtion:MODE MODulation ; MODulation:TYPE SWEep | Enable Sweep CH1. Enables the frequency sweep on channel 1. | None |
| INSTrument:SELect 1 ; SWEep:TIMe <Sec> | Set Sweep Time CH1. Sets the sweep time for channel 1. | Number: 0.0000005-0.01 |
| INSTrument:SELect 1 ; SWEep:SPACing <Type> | Set Sweep Spacing CH1. Sets the sweep spacing for channel 1. | Text: LINear,LOGarithmic |
| INSTrument:SELect 1 ; SWEep:FREQuency <Freq> | Set Sweep Start Freq CH1. Sets the sweep start frequency for channel 1. | Number |
| INSTrument:SELect 1 ; SWEep:FREQuency:STOP <Freq> | Set Sweep Stop Freq CH1. Sets the sweep stop frequency for channel 1. | Number |
| INSTrument:SELect 1 ; INITiate:CONTinuous OFF | Enable Burst CH1. Enables burst mode on channel 1. | None |
| INSTrument:SELect 1 ; INITiate:CONTinuous ON | Disable Burst CH1. Disables burst mode on channel 1. | None |
| INSTrument:SELect 1 ; TRIGger:COUNt <N> | Set Burst Cycles CH1. Sets the number of cycles per burst for channel 1. | Number: 1-16777216 |
| Command | What it does | Arguments |
|---|---|---|
| TRIGger:IMMediate | Trigger Now. Issues an immediate trigger. | None |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:ERRor? | Read Error. Reads and clears the next error-queue entry. | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). | None |
| *RST | Reset. Resets the instrument to its default state. | None |
| *CLS | Clear Status. Clears all event registers and the error queue. | None |
| *TST? | Self Test. Runs the self-test and returns 0 for pass. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *TRG | Trigger Bus. Generates a bus trigger. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Tabor Electronics's programming documentation for the SE5082 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Tabor Electronics's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The Tabor Electronics SE5082 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 45 SCPI commands for it: 9 queries that read values or state, and 36 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, TRIGger:IMMediate and SYSTem:ERRor?.
SYSTem:ERRor? (read error). Reads and clears the next error-queue entry. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Tabor Electronics SE5082 through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.