Function Generator · SCPI command reference

Tabor Electronics SE5082 SCPI commands

The Tabor Electronics SE5082 function generator is controlled remotely with SCPI commands. TestFlow's instrument library holds 45 commands for it, 9 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the SE5082 on a real bench.

Commands
45
Queries
9
Subsystems
7
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Tabor Electronics SE5082 and writes the report from the measured results.

Get started

Control the Tabor Electronics SE5082 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Tabor Electronics SE5082's VISA address

# Paste the address of your Tabor Electronics SE5082 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("TRIGger:IMMediate")  # Trigger Now
print(inst.query("SYSTem:ERRor?"))  # Read Error

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Tabor Electronics SE5082 and writes the report from the measured results.

Get started

Run a SE5082 test without writing code

Describe the test in a sentence, for example “trigger now on the SE5082, then read error and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

45 commands in 7 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Instrument (INSTrument) (34)

CommandWhat it doesArguments
INSTrument:SELect 1 ; OUTPut ONTurn On Output CH1. Enables channel 1 output.None
INSTrument:SELect 1 ; OUTPut OFFTurn Off Output CH1. Disables channel 1 output.None
INSTrument:SELect 1 ; OUTPut?Read Output State CH1. Reads channel 1 output state.None
INSTrument:SELect 1 ; FUNCtion:SHAPe <Shape>Set Function CH1. Sets the output waveform shape for channel 1.Text: SINusoid,TRIangle,SQUare,RAMP,SINC,GAUSsian,EXPonential,NOISe,DC
INSTrument:SELect 1 ; FUNCtion:SHAPe?Read Function CH1. Reads the output waveform shape for channel 1.None
INSTrument:SELect 1 ; FREQuency <Freq>Set Frequency CH1. Sets the output frequency in Hz for channel 1.Number
INSTrument:SELect 1 ; FREQuency?Read Frequency CH1. Reads the output frequency for channel 1.None
INSTrument:SELect 1 ; VOLTage <Amp>Set Amplitude CH1. Sets the output amplitude (Vpp) for channel 1.Number
INSTrument:SELect 1 ; VOLTage?Read Amplitude CH1. Reads the output amplitude for channel 1.None
INSTrument:SELect 1 ; VOLTage:OFFSet <Volt>Set Voltage Offset CH1. Sets the DC offset voltage for channel 1.Number
INSTrument:SELect 1 ; VOLTage:OFFSet?Read Voltage Offset CH1. Reads the DC offset voltage for channel 1.None
INSTrument:SELect 1 ; SINusoid:PHASe <Deg>Set Phase CH1. Sets the output phase in degrees for channel 1.Number: -360-360
INSTrument:SELect 1 ; SQUare:DCYCle <Pct>Set Square Duty Cycle CH1. Sets the square-wave duty cycle for channel 1.Number: 0-99.99
INSTrument:SELect 1 ; PULSe:WIDTh <Sec>Set Pulse Width CH1. Sets the pulse width in seconds for channel 1.Number
INSTrument:SELect 1 ; PULSe:WIDTh:PERCent <Pct>Set Pulse Duty Cycle CH1. Sets the pulse duty cycle for channel 1.Number: 0.01-99.99
INSTrument:SELect 1 ; PULSe:TRANsition <Sec>Set Pulse Edge CH1. Sets the pulse edge transition time for channel 1.Number
INSTrument:SELect 1 ; FUNCtion:MODE USER ; TRACe:SELect <Segment>Set Arb Waveform CH1. Selects the arbitrary waveform for channel 1.Number: 1-32000
INSTrument:SELect 1 ; FUNCtion:MODE MODulation ; MODulation:TYPE AMEnable AM CH1. Enables AM modulation on channel 1.None
INSTrument:SELect 1 ; MODulation:TYPE OFFDisable AM CH1. Disables AM modulation on channel 1.None
INSTrument:SELect 1 ; AM:DEPTh <Pct>Set AM Deviation CH1. Sets the AM depth percentage for channel 1.Number: 0-200
INSTrument:SELect 1 ; AM:INTernal:FREQuency <Freq>Set AM Int Freq CH1. Sets the internal AM modulating frequency for channel 1.Number
INSTrument:SELect 1 ; FUNCtion:MODE MODulation ; MODulation:TYPE FMEnable FM CH1. Enables FM modulation on channel 1.None
INSTrument:SELect 1 ; FM:DEViation <Freq>Set FM Deviation CH1. Sets the FM frequency deviation for channel 1.Number
INSTrument:SELect 1 ; FM:FREQuency <Freq>Set FM Int Freq CH1. Sets the internal FM modulating frequency for channel 1.Number
INSTrument:SELect 1 ; FUNCtion:MODE MODulation ; MODulation:TYPE FSKEnable FSK CH1. Enables FSK modulation on channel 1.None
INSTrument:SELect 1 ; FSK:FREQuency:SHIFted <Freq>Set FSK Hop Freq CH1. Sets the FSK hop frequency for channel 1.Number
INSTrument:SELect 1 ; FUNCtion:MODE MODulation ; MODulation:TYPE SWEepEnable Sweep CH1. Enables the frequency sweep on channel 1.None
INSTrument:SELect 1 ; SWEep:TIMe <Sec>Set Sweep Time CH1. Sets the sweep time for channel 1.Number: 0.0000005-0.01
INSTrument:SELect 1 ; SWEep:SPACing <Type>Set Sweep Spacing CH1. Sets the sweep spacing for channel 1.Text: LINear,LOGarithmic
INSTrument:SELect 1 ; SWEep:FREQuency <Freq>Set Sweep Start Freq CH1. Sets the sweep start frequency for channel 1.Number
INSTrument:SELect 1 ; SWEep:FREQuency:STOP <Freq>Set Sweep Stop Freq CH1. Sets the sweep stop frequency for channel 1.Number
INSTrument:SELect 1 ; INITiate:CONTinuous OFFEnable Burst CH1. Enables burst mode on channel 1.None
INSTrument:SELect 1 ; INITiate:CONTinuous ONDisable Burst CH1. Disables burst mode on channel 1.None
INSTrument:SELect 1 ; TRIGger:COUNt <N>Set Burst Cycles CH1. Sets the number of cycles per burst for channel 1.Number: 1-16777216

Trigger (TRIGger) (1)

CommandWhat it doesArguments
TRIGger:IMMediateTrigger Now. Issues an immediate trigger.None

System (SYSTem) (1)

CommandWhat it doesArguments
SYSTem:ERRor?Read Error. Reads and clears the next error-queue entry.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (6)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*TST?Self Test. Runs the self-test and returns 0 for pass.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*TRGTrigger Bus. Generates a bus trigger.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Tabor Electronics's programming documentation for the SE5082 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Tabor Electronics's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Tabor Electronics SE5082 support SCPI remote control?

Yes. The Tabor Electronics SE5082 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 45 SCPI commands for it: 9 queries that read values or state, and 36 settings and actions.

How do I control the Tabor Electronics SE5082 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, TRIGger:IMMediate and SYSTem:ERRor?.

Which command reads a value from the Tabor Electronics SE5082?

SYSTem:ERRor? (read error). Reads and clears the next error-queue entry. The full list of queries is in the command reference on this page, grouped by subsystem.