Tabor Electronics instrument command references

Remote-control command sets for 6 Tabor Electronics instruments from TestFlow's instrument library, each with its arguments and a working PyVISA example.

The library covers 6 function generators from Tabor Electronics: 168 commands in total, 33 of them queries that read a value or a setting back. These are the commands TestFlow's agent sends when it automates a test on Tabor Electronics hardware, so every entry is one that drives a real instrument.

Tabor Electronics function generators

Commands shared across Tabor Electronics instruments

These commands appear on more than one Tabor Electronics instrument in the library, so a script that uses them carries over between models.

CommandWhat it doesModels
*CLSClears all event registers and the error queue.4 of 4
*IDN?Returns the instrument identification string (manufacturer, model, serial, firmware).4 of 4
*OPC?Returns 1 when all pending operations are complete.4 of 4
*RSTResets the instrument to its default state.4 of 4
*TRGGenerates a bus trigger.4 of 4
SYSTem:ERRor?Reads and clears the next error-queue entry.4 of 4
TRIGger:IMMediateIssues an immediate trigger.4 of 4
*WAIWaits until all pending operations are complete.3 of 4

Control a Tabor Electronics instrument from Python

The pattern is the same for every Tabor Electronics instrument here: open it through VISA, identify it, then write settings and query values. This example uses the Tabor Electronics SE5082; the full SE5082 reference has every command.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Tabor Electronics SE5082's VISA address

# Paste the address of your Tabor Electronics SE5082 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("TRIGger:IMMediate")  # Trigger Now
print(inst.query("SYSTem:ERRor?"))  # Read Error

inst.close()

Related guides

Frequently asked questions

Which Tabor Electronics instruments have a command reference here?

6 Tabor Electronics models (function generator): SE5082, WW1071, WW2571A, WW1072, WW2572A, WW1074. Each page lists every remote-control command TestFlow's agent uses for that instrument, with its arguments.

Do Tabor Electronics instruments use SCPI?

Yes. Every Tabor Electronics model in TestFlow's library is programmed with SCPI commands over its remote interfaces, including the IEEE 488.2 common commands such as *IDN? and *RST.

How do I control a Tabor Electronics instrument from Python?

Install PyVISA and a VISA backend, list the connected instruments with ResourceManager().list_resources(), open the Tabor Electronics instrument by its VISA address (USB, LAN or GPIB), then send commands with write() and read values with query(). Each model page has a working example.

Can I automate Tabor Electronics instruments without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on your Tabor Electronics instruments through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today