Thermal Forcing System · SCPI command reference

inTEST ATS-710E, ATS-730E, ATS-750E, ATS-770E, ATS-810E, ATS-830E, ATS-850E, and ATS-870E SCPI commands

The inTEST ATS-710E, ATS-730E, ATS-750E, ATS-770E, ATS-810E, ATS-830E, ATS-850E, and ATS-870E thermal forcing system is controlled remotely with SCPI commands. TestFlow's instrument library holds 72 commands for it, 34 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the ATS-710E on a real bench.

Commands
72
Queries
34
Subsystems
37
Models covered
8

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your inTEST ATS-710E, ATS-730E, ATS-750E, ATS-770E, ATS-810E, ATS-830E, ATS-850E, or ATS-870E and writes the report from the measured results.

Get started

Control the inTEST ATS-710E from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the inTEST ATS-710E's VISA address

# Paste the address of your inTEST ATS-710E (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("SETN 0")  # Select Setpoint
print(inst.query("SETN?"))  # Read Selected Setpoint

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your inTEST ATS-710E, ATS-730E, ATS-750E, ATS-770E, ATS-810E, ATS-830E, ATS-850E, or ATS-870E and writes the report from the measured results.

Get started

Run a ATS-710E test without writing code

Describe the test in a sentence, for example “select setpoint on the ATS-710E, then read selected setpoint and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

72 commands in 37 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values. The ATS-710E, ATS-730E, ATS-750E, ATS-770E, ATS-810E, ATS-830E, ATS-850E, and ATS-870E share this command set in TestFlow's library.

Other subsystem (4)

CommandWhat it doesArguments
%RMRemote Mode. Enters remote mode (front panel shows a Return to Local button).None
%LLLocal Lockout. Enters local lockout (front panel disabled).None
%GLGo To Local. Returns the system to local (front panel) control.None
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

FLOW subsystem (3)

CommandWhat it doesArguments
FLOW 1Turn On Flow. Turns on the main nozzle air flow.None
FLOW 0Turn Off Flow. Turns off the main nozzle air flow.None
FLOW?Read Flow State. Reads the main air flow state (1 on or 0 off).None

HEAD subsystem (3)

CommandWhat it doesArguments
HEAD 1Head Down. Lowers the test head (ignored if the head is locked).None
HEAD 0Head Up. Raises the test head (ignored if the head is locked).None
HEAD?Read Head State. Reads the head position (1 down or 0 up).None

COOL subsystem (3)

CommandWhat it doesArguments
COOL 1Turn On Compressor. Turns on the compressor (about 60 s before cooling is ready).None
COOL 0Turn Off Compressor. Turns off the compressor.None
COOL?Read Compressor State. Reads the compressor state (1 on or 0 off).None

DUTM subsystem (3)

CommandWhat it doesArguments
DUTM 1Control On DUT. Switches to DUT control mode (temperature controlled on the DUT sensor).None
DUTM 0Control On Air. Switches to air control mode (temperature controlled on the air sensor).None
DUTM?Read Control Mode. Reads the control mode (1 DUT or 0 air).None

LRNM subsystem (3)

CommandWhat it doesArguments
LRNM 1Turn On Learn Mode. Turns on DUT automatic tuning (learning mode).None
LRNM 0Turn Off Learn Mode. Turns off DUT automatic tuning (learning mode).None
LRNM?Read Learn Mode. Reads the DUT learning mode state (1 on or 0 off).None

CYCL subsystem (3)

CommandWhat it doesArguments
CYCL 1Start Cycling. Starts temperature cycling through the enabled setpoints.None
CYCL 0Stop Cycling. Stops cycling (also required after end of cycling or stop-on-fail).None
CYCL?Read Cycle Number. Reads the current cycle number.None

SETN subsystem (2)

CommandWhat it doesArguments
SETN <Setpoint_Num>Select Setpoint. Selects the active setpoint: 0 hot, 1 ambient, 2 cold on the Operator screen (0-17 on the Cycle screen).Number: 0,17
SETN?Read Selected Setpoint. Reads the number of the currently selected setpoint.None

SETP subsystem (2)

CommandWhat it doesArguments
SETP <Temp>Set Setpoint. Sets the temperature of the selected setpoint in °C (must be within LLIM/ULIM).Number: -99.9,225.0
SETP?Read Setpoint. Reads the temperature of the selected setpoint in °C.None

RAMP subsystem (2)

CommandWhat it doesArguments
RAMP <Rate>Set Ramp Rate. Sets the ramp rate of the selected setpoint in °C/min (0-99.9 in 0.1 steps or 100-9999).Number: 0,9999
RAMP?Read Ramp Rate. Reads the ramp rate of the selected setpoint in °C/min.None

SOAK subsystem (2)

CommandWhat it doesArguments
SOAK <Seconds>Set Soak Time. Sets the soak time of the selected setpoint in seconds (0-9999).Number: 0,9999
SOAK?Read Soak Time. Reads the soak time of the selected setpoint in seconds.None

WNDW subsystem (2)

CommandWhat it doesArguments
WNDW <Window>Set Window. Sets the at-temperature window (±°C) of the selected setpoint (0.1-9.9).Number: 0.1,9.9
WNDW?Read Window. Reads the at-temperature window of the selected setpoint.None

ULIM subsystem (2)

CommandWhat it doesArguments
ULIM <Temp>Set Upper Limit. Sets the upper air temperature limit in °C.Number: 25,225
ULIM?Read Upper Limit. Reads the upper air temperature limit in °C.None

LLIM subsystem (2)

CommandWhat it doesArguments
LLIM <Temp>Set Lower Limit. Sets the lower air temperature limit in °C.Number: -99,25
LLIM?Read Lower Limit. Reads the lower air temperature limit in °C.None

ADMD subsystem (2)

CommandWhat it doesArguments
ADMD <Temp>Set Max Air DUT Difference. Sets the maximum allowed air-to-DUT temperature difference in °C (10-300).Number: 10,300
ADMD?Read Max Air DUT Difference. Reads the maximum allowed air-to-DUT temperature difference in °C.None

DSNS subsystem (2)

CommandWhat it doesArguments
DSNS <Type>Set DUT Sensor Type. Sets the DUT sensor type (0 none, 1 T-type thermocouple, 2 K-type thermocouple).Number: 0,1,2
DSNS?Read DUT Sensor Type. Reads the DUT sensor type.None

DUTC subsystem (2)

CommandWhat it doesArguments
DUTC <Constant>Set DUT Thermal Constant. Sets the DUT thermal constant (20-500; higher values for larger mass and less overshoot).Number: 20,500
DUTC?Read DUT Thermal Constant. Reads the DUT thermal constant.None

TTIM subsystem (2)

CommandWhat it doesArguments
TTIM <Seconds>Set Test Time. Sets the maximum test time per setpoint in seconds (0-9999).Number: 0,9999
TTIM?Read Test Time. Reads the maximum test time per setpoint in seconds.None

CYCC subsystem (2)

CommandWhat it doesArguments
CYCC <Count>Set Cycle Count. Sets the number of temperature cycles to run (1-9999).Number: 1,9999
CYCC?Read Cycle Count. Reads the configured cycle count.None

SFIL subsystem (2)

CommandWhat it doesArguments
SFIL "<File_Name>"Load Setup File. Loads a stored setup file (1-12); wait 2 s after.Text
SFIL?Read Setup File. Reads the number of the loaded setup file.None

SETD subsystem (1)

CommandWhat it doesArguments
SETD?Read Dynamic Setpoint. Reads the live (ramping) setpoint in °C.None

TEMP subsystem (1)

CommandWhat it doesArguments
TEMP?Read Temperature. Reads the main control temperature in °C (air in air mode or DUT in DUT mode).None

TMPA subsystem (1)

CommandWhat it doesArguments
TMPA?Read Air Temperature. Reads the air temperature in °C regardless of control mode.None

TMPD subsystem (1)

CommandWhat it doesArguments
TMPD?Read DUT Temperature. Reads the DUT temperature in °C regardless of control mode.None

FLWR subsystem (1)

CommandWhat it doesArguments
FLWR?Read Flow Rate SCFM. Reads the measured main air flow rate in scfm.None

FLRL subsystem (1)

CommandWhat it doesArguments
FLRL?Read Flow Rate LPS. Reads the measured main air flow rate in liters per second.None

NEXT subsystem (1)

CommandWhat it doesArguments
NEXTNext Setpoint. Steps to the next setpoint while cycling (error if not cycling).None

RSTO subsystem (1)

CommandWhat it doesArguments
RSTOReset Operator. Forces the Operator screen and resets errors with setpoint 1 (ambient) active; wait 4 s after.None

CLER subsystem (1)

CommandWhat it doesArguments
CLERClear Errors. Clears the device error register (EROR); wait 4 s after.None

TECR subsystem (1)

CommandWhat it doesArguments
TECR?Read Temp Condition. Reads the temperature condition register (b0 at temp, b1 not at temp, b2 end of test, b3 end of cycle, b4 end of all cycles, b5 stopped, b7 datalog).None

TESR subsystem (1)

CommandWhat it doesArguments
TESR?Read Temp Event. Reads the latched temperature event register (same bits as TECR; cleared when read).None

EROR subsystem (1)

CommandWhat it doesArguments
EROR?Read Error Register. Reads the 16-bit device error register (overheat, low flow, low air pressure, sensor open etc.).None

AUXC subsystem (1)

CommandWhat it doesArguments
AUXC?Read Aux Condition. Reads the auxiliary condition register (head, compressor, DUT mode, flow, ready, manual/program, ramp mode).None

WHAT subsystem (1)

CommandWhat it doesArguments
WHAT?Read System State. Reads what the system is currently doing (operator/manual or cycle/program).None

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (8)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets to the Cycle screen with errors and limits reset and setpoint 5 active; wait 4 s after.None
*CLSClear Status. Clears the ESR and TESR status registers.None
*TST?Self Test. Self-test query (dummy; always returns 0).None
*ESR?Read Event Status. Reads and clears the standard event status register (command, execution, device and query errors).None
*ESE <Mask>Set Event Status Enable. Sets the standard event status enable mask (0-255).Number: 0,255
*STB?Read Status Byte. Reads the status byte (ready, MSS, ESB, MAV, TESR summary, EROR summary).None
*SRE <Mask>Set Service Request Enable. Sets the service request enable mask (0-255).Number: 0,255

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from inTEST's programming documentation for the ATS-710E, ATS-730E, ATS-750E, ATS-770E, ATS-810E, ATS-830E, ATS-850E, and ATS-870E and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by inTEST's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the inTEST ATS-710E support SCPI remote control?

Yes. The inTEST ATS-710E accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 72 SCPI commands for it: 34 queries that read values or state, and 38 settings and actions.

How do I control the inTEST ATS-710E from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, SETN 0 and SETN?.

Which command reads a value from the inTEST ATS-710E?

SETN? (read selected setpoint). Reads the number of the currently selected setpoint. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the inTEST ATS-710E without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the inTEST ATS-710E through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.