Remote-control command sets for 22 inTEST instruments from TestFlow's instrument library, each with its arguments and a working PyVISA example.
The library covers 22 thermal forcing systems from inTEST: 363 commands in total, 171 of them queries that read a value or a setting back. These are the commands TestFlow's agent sends when it automates a test on inTEST hardware, so every entry is one that drives a real instrument.
73 SCPI commands, 34 queries
74 SCPI commands, 35 queries
72 SCPI commands, 34 queries
72 SCPI commands, 34 queries
72 SCPI commands, 34 queries
These commands appear on more than one inTEST instrument in the library, so a script that uses them carries over between models.
| Command | What it does | Models |
|---|---|---|
| *CLS | Clears the ESR and TESR status registers. | 5 of 5 |
| *ESE | Sets the standard event status enable mask (0-255). | 5 of 5 |
| *ESR? | Reads and clears the standard event status register (command, execution, device and query errors). | 5 of 5 |
| *IDN? | Returns the instrument identification string (manufacturer, model, serial, firmware). | 5 of 5 |
| *RST | Resets to the Cycle screen with errors and limits reset and setpoint 5 active; wait 4 s after. | 5 of 5 |
| *SRE | Sets the service request enable mask (0-255). | 5 of 5 |
| *STB? | Reads the status byte (ready, MSS, ESB, MAV, TESR summary, EROR summary). | 5 of 5 |
| *TST? | Self-test query (dummy; always returns 0). | 5 of 5 |
The pattern is the same for every inTEST instrument here: open it through VISA, identify it, then write settings and query values. This example uses the inTEST ATS-505; the full ATS-505 reference has every command.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the inTEST ATS-505's VISA address
# Paste the address of your inTEST ATS-505 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("SETN 0") # Select Setpoint
print(inst.query("SETN?")) # Read Selected Setpoint
inst.close()22 inTEST models (thermal forcing system): ATS-505, ATS-515, ATS-535, ATS-605, ATS-615, ATS-625, ATS-635, ATS-525, ATS-545, ATS-645, ATS-710E, ATS-730E, ATS-750E, ATS-770E, ATS-810E, ATS-830E, ATS-850E, ATS-870E, ECO-560, ECO-660, ECO-710E, ECO-810E. Each page lists every remote-control command TestFlow's agent uses for that instrument, with its arguments.
Yes. Every inTEST model in TestFlow's library is programmed with SCPI commands over its remote interfaces, including the IEEE 488.2 common commands such as *IDN? and *RST.
Install PyVISA and a VISA backend, list the connected instruments with ResourceManager().list_resources(), open the inTEST instrument by its VISA address (USB, LAN or GPIB), then send commands with write() and read values with query(). Each model page has a working example.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on your inTEST instruments through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.