In TestFlow's instrument library, the Keithley 3390 takes 88 SCPI commands, 10 of them queries, and the Tektronix AFG31022 takes 95 SCPI commands, 12 of them queries. That is 7 more on the AFG31022. Counting distinct command headers (the command path without its arguments), 12 are accepted by both, 62 exist only on the 3390, and 69 only on the AFG31022. 16% of the 3390's command headers also exist on the AFG31022.
Both libraries have commands under OUTPut, SYSTem, and TRIGger. Only the 3390 has VOLTage, FREQuency, APPLy, BURSt, FUNCtion, and AM and 6 more. Only the AFG31022 has SOURce and DISPlay.
Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?.
TestFlow's library gives the AFG3102C, AFG31052, AFG31102, AFG31152, AFG31252, and AFG3252C the same command set as the AFG31022, so the AFG31022 column applies to them too.
Describe the test; TestFlow's agent uses these command sets to drive your Keithley 3390 or Tektronix AFG31022 and writes the report from the measured results.
Counts come from TestFlow's instrument library, the command sets its AI agent uses to drive each instrument. A distinct command header is the command path without its arguments, so :OUTPut ON and :OUTPut OFF count once.
| Keithley 3390 | Tektronix AFG31022 | |
|---|---|---|
| Commands in TestFlow's library | 88 | 95 |
| Queries (read a value or state) | 10 | 12 |
| Settings and actions | 78 | 83 |
| Subsystems | 19 | 9 |
| Distinct command headers | 74 | 81 |
| Headers the other lacks | 62 | 69 |
| Command language | SCPI | SCPI |
| Operation complete | *OPC? | *OPC? |
| Error queue | SYSTem:ERRor? | SYSTem:ERRor? |
| Models on this command set | 3390 | AFG31022, AFG3102C, AFG31052, AFG31102, AFG31152, AFG31252, AFG3252C |
12 command headers are in both libraries. Where the AFG31022 library writes the command differently, its form is shown under the 3390's.
| Command | What it does |
|---|---|
| OUTPut:POLarity NORMalAFG31022: OUTPut<Channel>:POLarity NORMal | Set Output Polarity Normal. Sets output polarity to normal. |
| SYSTem:BEEPer:STATe ON | Enable Beeper. Enables the beeper. |
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). |
| SYSTem:ERRor? | Read Error. Reads and clears the next error-queue entry. |
| *RST | Reset. Resets the instrument to its default state. |
| *CLS | Clear Status. Clears all event registers and the error queue. |
| *TST? | Self Test. Runs the self-test and returns 0 for pass. |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. |
| *WAI | Wait To Continue. Waits until all pending operations are complete. |
| *TRG | Trigger Bus. Generates a bus trigger. |
| *SAV <Slot> | Save State Slot. Stores the current state to a memory slot (0 to 4). |
| *RCL <Slot> | Recall State Slot. Recalls a state from a memory slot (0 to 4). |
62 command headers in the 3390 library have no match in the AFG31022 library. Below are 24 of them from the 6 largest subsystems; the full list is in the Keithley 3390 command reference.
| Command | What it does |
|---|---|
| VOLTage <Amp> | Set Amplitude. Sets the output amplitude (Vpp). |
| VOLTage? | Read Amplitude. Reads the output amplitude. |
| VOLTage:OFFSet <Volt> | Set Voltage Offset. Sets the DC offset voltage. |
| VOLTage:OFFSet? | Read Voltage Offset. Reads the DC offset voltage. |
| Command | What it does |
|---|---|
| APPLy:SINusoid <Freq>,<Amp>,<Offset> | Apply Sine. Sets sine with the given frequency, amplitude and offset. |
| APPLy:SQUare <Freq>,<Amp>,<Offset> | Apply Square. Sets square with the given frequency, amplitude and offset. |
| APPLy:RAMP <Freq>,<Amp>,<Offset> | Apply Ramp. Sets ramp with the given frequency, amplitude and offset. |
| APPLy:PULSe <Freq>,<Amp>,<Offset> | Apply Pulse. Sets pulse with the given frequency, amplitude and offset. |
| Command | What it does |
|---|---|
| FREQuency <Freq> | Set Frequency. Sets the output frequency in Hz. |
| FREQuency? | Read Frequency. Reads the output frequency. |
| FREQuency:STARt <Freq> | Set Sweep Start Freq. Sets the sweep start frequency. |
| FREQuency:STOP <Freq> | Set Sweep Stop Freq. Sets the sweep stop frequency. |
| Command | What it does |
|---|---|
| BURSt:STATe ON | Enable Burst. Enables burst mode. |
| BURSt:MODE <Mode> | Set Burst Mode. Sets the burst mode. |
| BURSt:NCYCles <N> | Set Burst Cycles. Sets the number of cycles per burst. |
| BURSt:INTernal:PERiod <Sec> | Set Burst Period. Sets the internal burst period. |
| Command | What it does |
|---|---|
| FUNCtion <Shape> | Set Function. Sets the output waveform shape. |
| FUNCtion? | Read Function. Reads the output waveform shape. |
| FUNCtion:RAMP:SYMMetry <Pct> | Set Ramp Symmetry. Sets the ramp symmetry percentage. |
| FUNCtion:SQUare:DCYCle <Pct> | Set Square Duty Cycle. Sets the square-wave duty cycle percentage. |
| Command | What it does |
|---|---|
| AM:STATe ON | Enable AM. Enables AM modulation. |
| AM:DEPTh <Pct> | Set AM Deviation. Sets the AM depth percentage. |
| AM:SOURce <Src> | Set AM Source. Sets the AM modulation source. |
| AM:INTernal:FREQuency <Freq> | Set AM Int Freq. Sets the internal AM modulating frequency. |
69 command headers in the AFG31022 library have no match in the 3390 library. Below are 14 of them from the 5 largest subsystems; the full list is in the Tektronix AFG31022 command reference.
| Command | What it does |
|---|---|
| SOURce<Channel>:FUNCtion:SHAPe <Shape> | Set Function. Sets the output waveform shape for the selected channel. |
| SOURce<Channel>:FUNCtion:SHAPe? | Read Function. Reads the output waveform shape for the selected channel. |
| SOURce<Channel>:FREQuency:FIXed <Freq> | Set Frequency. Sets the output frequency in Hz for the selected channel. |
| SOURce<Channel>:FREQuency:FIXed? | Read Frequency. Reads the output frequency for the selected channel. |
| Command | What it does |
|---|---|
| OUTPut<Channel>:STATe ON | Turn On Output. Enables the selected channel output. |
| OUTPut<Channel>:STATe? | Read Output State. Reads whether the selected channel output is on. |
| OUTPut<Channel>:IMPedance <Ohm> | Set Output Impedance. Sets the the selected channel output load impedance in ohms (1 to 10k). |
| OUTPut<Channel>:IMPedance? | Read Output Impedance. Reads the the selected channel output load impedance. |
| Command | What it does |
|---|---|
| TRIGger:SEQuence:SOURce <Src> | Set Trigger Source. Sets the trigger source. |
| TRIGger:SEQuence:SLOPe <Slope> | Set Trigger Slope. Sets the external trigger slope. |
| TRIGger:SEQuence:TIMer <Sec> | Set Trigger Timer. Sets the internal trigger timer period. |
| TRIGger:SEQuence:IMMediate | Trigger Now. Issues an immediate (manual) trigger. |
| Command | What it does |
|---|---|
| DISPlay:BRIGhtness <Level> | Enable Display. Sets the display brightness (0 to 1). |
| Command | What it does |
|---|---|
| *OPT? | Read Options. Queries the installed options. |
With PyVISA and any VISA backend, this opens both instruments, identifies them, sends one setting, and reads one value from each. For the setting, both libraries hold OUTPut:POLarity (set output polarity normal); the AFG31022 library writes it as OUTPut1:POLarity NORMal. For the reading, both libraries hold SYSTem:ERRor? (read error), and the same line runs on each. For the basics, see the PyVISA tutorial.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find both VISA addresses
a = rm.open_resource("PASTE_3390_ADDRESS") # Keithley 3390
b = rm.open_resource("PASTE_AFG31022_ADDRESS") # Tektronix AFG31022
for inst in (a, b):
inst.timeout = 5000 # ms
print(inst.query("*IDN?"))
# The same setting on both: Set Output Polarity Normal
a.write("OUTPut:POLarity NORMal")
b.write("OUTPut1:POLarity NORMal")
# The same reading on both: Read Error
print(a.query("SYSTem:ERRor?"))
print(b.query("SYSTem:ERRor?"))
a.close()
b.close()Describe the test; TestFlow's agent uses these command sets to drive your Keithley 3390 or Tektronix AFG31022 and writes the report from the measured results.
In TestFlow's library the 3390 has 88 SCPI commands and the AFG31022 has 95 SCPI commands. 12 command headers are common to both, 62 are only on the 3390 (mostly VOLTage and APPLy), and 69 are only on the AFG31022 (mostly SOURce and OUTPut).
Partly. 12 command headers are accepted by both, including OUTPut:POLarity, SYSTem:BEEPer:STATe, and SYSTem:ERRor?. 131 are not, for example VOLTage on the 3390 and SOURce<Channel>:FUNCtion:SHAPe on the AFG31022, so a script that uses those needs a separate branch for each instrument.
The AFG31022: 88 commands for the 3390 against 95 for the AFG31022 in TestFlow's library. Of those, 10 on the 3390 and 12 on the AFG31022 are queries that read a value or state, and the library splits them into 19 and 9 subsystems.
Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?. Each command named here is listed in the tables on this page and on each instrument's command reference.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.