In TestFlow's instrument library, the Keithley 3390 takes 88 SCPI commands, 10 of them queries, and the Siglent SDG2042X takes 77 SCPI commands, 9 of them queries. That is 11 more on the 3390. Counting distinct command headers (the command path without its arguments), 9 are accepted by both, 65 exist only on the 3390, and 17 only on the SDG2042X. 12% of the 3390's command headers also exist on the SDG2042X.
Only the 3390 has OUTPut, VOLTage, FREQuency, APPLy, BURSt, and FUNCtion and 9 more. Only the SDG2042X has C, COUP, ROSC, BUZZ, and SCSV.
Both libraries synchronise with *OPC?. Only the 3390 library has an error-queue read (SYSTem:ERRor?); the SDG2042X library has none.
TestFlow's library gives the SDG6022X the same command set as the SDG2042X, so the SDG2042X column applies to it too.
Describe the test; TestFlow's agent uses these command sets to drive your Keithley 3390 or Siglent SDG2042X and writes the report from the measured results.
Counts come from TestFlow's instrument library, the command sets its AI agent uses to drive each instrument. A distinct command header is the command path without its arguments, so :OUTPut ON and :OUTPut OFF count once.
| Keithley 3390 | Siglent SDG2042X | |
|---|---|---|
| Commands in TestFlow's library | 88 | 77 |
| Queries (read a value or state) | 10 | 9 |
| Settings and actions | 78 | 68 |
| Subsystems | 19 | 9 |
| Distinct command headers | 74 | 26 |
| Headers the other lacks | 65 | 17 |
| Command language | SCPI | SCPI |
| Operation complete | *OPC? | *OPC? |
| Error queue | SYSTem:ERRor? | Not in library |
| Models on this command set | 3390 | SDG2042X, SDG6022X |
9 command headers are in both libraries.
| Command | What it does |
|---|---|
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). |
| *RST | Reset. Resets the instrument to its default state. |
| *CLS | Clear Status. Clears all event registers and the error queue. |
| *TST? | Self Test. Runs the self-test and returns 0 for pass. |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. |
| *WAI | Wait To Continue. Waits until all pending operations are complete. |
| *TRG | Trigger Bus. Generates a bus trigger. |
| *SAV <Slot> | Save State Slot. Stores the current state to a memory slot (0 to 4). |
| *RCL <Slot> | Recall State Slot. Recalls a state from a memory slot (0 to 4). |
65 command headers in the 3390 library have no match in the SDG2042X library. Below are 24 of them from the 6 largest subsystems; the full list is in the Keithley 3390 command reference.
| Command | What it does |
|---|---|
| VOLTage <Amp> | Set Amplitude. Sets the output amplitude (Vpp). |
| VOLTage? | Read Amplitude. Reads the output amplitude. |
| VOLTage:OFFSet <Volt> | Set Voltage Offset. Sets the DC offset voltage. |
| VOLTage:OFFSet? | Read Voltage Offset. Reads the DC offset voltage. |
| Command | What it does |
|---|---|
| APPLy:SINusoid <Freq>,<Amp>,<Offset> | Apply Sine. Sets sine with the given frequency, amplitude and offset. |
| APPLy:SQUare <Freq>,<Amp>,<Offset> | Apply Square. Sets square with the given frequency, amplitude and offset. |
| APPLy:RAMP <Freq>,<Amp>,<Offset> | Apply Ramp. Sets ramp with the given frequency, amplitude and offset. |
| APPLy:PULSe <Freq>,<Amp>,<Offset> | Apply Pulse. Sets pulse with the given frequency, amplitude and offset. |
| Command | What it does |
|---|---|
| FREQuency <Freq> | Set Frequency. Sets the output frequency in Hz. |
| FREQuency? | Read Frequency. Reads the output frequency. |
| FREQuency:STARt <Freq> | Set Sweep Start Freq. Sets the sweep start frequency. |
| FREQuency:STOP <Freq> | Set Sweep Stop Freq. Sets the sweep stop frequency. |
| Command | What it does |
|---|---|
| BURSt:STATe ON | Enable Burst. Enables burst mode. |
| BURSt:MODE <Mode> | Set Burst Mode. Sets the burst mode. |
| BURSt:NCYCles <N> | Set Burst Cycles. Sets the number of cycles per burst. |
| BURSt:INTernal:PERiod <Sec> | Set Burst Period. Sets the internal burst period. |
| Command | What it does |
|---|---|
| FUNCtion <Shape> | Set Function. Sets the output waveform shape. |
| FUNCtion? | Read Function. Reads the output waveform shape. |
| FUNCtion:RAMP:SYMMetry <Pct> | Set Ramp Symmetry. Sets the ramp symmetry percentage. |
| FUNCtion:SQUare:DCYCle <Pct> | Set Square Duty Cycle. Sets the square-wave duty cycle percentage. |
| Command | What it does |
|---|---|
| OUTPut ON | Turn On Output. Enables the output. |
| OUTPut? | Read Output State. Reads whether the output is on. |
| OUTPut:LOAD <Ohm> | Set Output Load. Sets the output load in ohms (1 to 10k); use INF for high-Z. |
| OUTPut:POLarity NORMal | Set Output Polarity Normal. Sets output polarity to normal. |
17 command headers in the SDG2042X library have no match in the 3390 library. Below are 9 of them from the 6 largest subsystems; the full list is in the Siglent SDG2042X command reference.
| Command | What it does |
|---|---|
| C<Channel>:OUTP ON | Turn On Output. Enables the selected channel output. |
| C<Channel>:OUTP? | Read Output State. Reads the selected channel output state and settings. |
| C<Channel>:BSWV WVTP,<Shape> | Set Function. Sets the basic waveform type for the selected channel. |
| C<Channel>:BSWV? | Read Basic Waveform. Reads all basic-waveform parameters for the selected channel. |
| Command | What it does |
|---|---|
| BUZZ ON | Buzzer On. Enables the buzzer. |
| Command | What it does |
|---|---|
| COUP TRACE,ON | Enable Channel Coupling. Enables channel tracking/coupling. |
| Command | What it does |
|---|---|
| *OPT? | Read Options. Queries the installed options. |
| Command | What it does |
|---|---|
| ROSC INT | Set Clock Internal. Uses the internal reference clock. |
| Command | What it does |
|---|---|
| SCSV <Minutes> | Screen Save On. Enables the screen saver. |
With PyVISA and any VISA backend, this opens both instruments, identifies them, sends one setting, and reads one value from each. For the setting, the two libraries have no common command with a worked example on both, so each instrument uses its own: OUTPut ON on the 3390 and C1:OUTP ON on the SDG2042X. For the reading, the two libraries have no common command with a worked example on both, so each instrument uses its own: OUTPut? on the 3390 and *TST? on the SDG2042X. For the basics, see the PyVISA tutorial.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find both VISA addresses
a = rm.open_resource("PASTE_3390_ADDRESS") # Keithley 3390
b = rm.open_resource("PASTE_SDG2042X_ADDRESS") # Siglent SDG2042X
for inst in (a, b):
inst.timeout = 5000 # ms
print(inst.query("*IDN?"))
# No shared setting with an example on both, so each uses its own command
a.write("OUTPut ON") # Turn On Output
b.write("C1:OUTP ON") # Turn On Output
# No shared reading with an example on both, so each uses its own command
print(a.query("OUTPut?")) # Read Output State
print(b.query("*TST?")) # Self Test
a.close()
b.close()Describe the test; TestFlow's agent uses these command sets to drive your Keithley 3390 or Siglent SDG2042X and writes the report from the measured results.
In TestFlow's library the 3390 has 88 SCPI commands and the SDG2042X has 77 SCPI commands. 9 command headers are common to both, 65 are only on the 3390 (mostly VOLTage and APPLy), and 17 are only on the SDG2042X (mostly C and BUZZ).
Partly. 9 command headers are accepted by both. 82 are not, for example VOLTage on the 3390 and C<Channel>:OUTP on the SDG2042X, so a script that uses those needs a separate branch for each instrument.
The 3390: 88 commands for the 3390 against 77 for the SDG2042X in TestFlow's library. Of those, 10 on the 3390 and 9 on the SDG2042X are queries that read a value or state, and the library splits them into 19 and 9 subsystems.
Both libraries synchronise with *OPC?. Only the 3390 library has an error-queue read (SYSTem:ERRor?); the SDG2042X library has none. Each command named here is listed in the tables on this page and on each instrument's command reference.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.