Function Generator · SCPI command reference

Keithley 3390 SCPI commands

The Keithley 3390 function generator is controlled remotely with SCPI commands. TestFlow's instrument library holds 88 commands for it, 10 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the 3390 on a real bench.

Commands
88
Queries
10
Subsystems
19
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Keithley 3390 and writes the report from the measured results.

Get started

Control the Keithley 3390 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Keithley 3390's VISA address

# Paste the address of your Keithley 3390 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("OUTPut ON")  # Turn On Output
print(inst.query("OUTPut?"))  # Read Output State

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Keithley 3390 and writes the report from the measured results.

Get started

Run a 3390 test without writing code

Describe the test in a sentence, for example “turn on output on the 3390, then read output state and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

88 commands in 19 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Output (OUTPut) (8)

CommandWhat it doesArguments
OUTPut ONTurn On Output. Enables the output.None
OUTPut OFFTurn Off Output. Disables the output.None
OUTPut?Read Output State. Reads whether the output is on.None
OUTPut:LOAD <Ohm>Set Output Load. Sets the output load in ohms (1 to 10k); use INF for high-Z.Number
OUTPut:POLarity NORMalSet Output Polarity Normal. Sets output polarity to normal.None
OUTPut:POLarity INVertedSet Output Polarity Inverted. Sets output polarity to inverted.None
OUTPut:SYNC ONTurn On Sync. Enables the Sync output.None
OUTPut:SYNC OFFTurn Off Sync. Disables the Sync output.None

Voltage (VOLTage) (7)

CommandWhat it doesArguments
VOLTage <Amp>Set Amplitude. Sets the output amplitude (Vpp).Number
VOLTage?Read Amplitude. Reads the output amplitude.None
VOLTage:OFFSet <Volt>Set Voltage Offset. Sets the DC offset voltage.Number
VOLTage:OFFSet?Read Voltage Offset. Reads the DC offset voltage.None
VOLTage:HIGH <Volt>Set Voltage High. Sets the high voltage level.Number
VOLTage:LOW <Volt>Set Voltage Low. Sets the low voltage level.Number
VOLTage:UNIT <Unit>Set Voltage Unit. Sets the amplitude unit.Text: VPP,VRMS,DBM

Frequency (FREQuency) (6)

CommandWhat it doesArguments
FREQuency <Freq>Set Frequency. Sets the output frequency in Hz.Number
FREQuency?Read Frequency. Reads the output frequency.None
FREQuency:STARt <Freq>Set Sweep Start Freq. Sets the sweep start frequency.Number
FREQuency:STOP <Freq>Set Sweep Stop Freq. Sets the sweep stop frequency.Number
FREQuency:CENTer <Freq>Set Sweep Center Freq. Sets the sweep center frequency.Number
FREQuency:SPAN <Freq>Set Sweep Span. Sets the sweep frequency span.Number

Apply (APPLy) (6)

CommandWhat it doesArguments
APPLy:SINusoid <Freq>,<Amp>,<Offset>Apply Sine. Sets sine with the given frequency, amplitude and offset.Number; Number; Number
APPLy:SQUare <Freq>,<Amp>,<Offset>Apply Square. Sets square with the given frequency, amplitude and offset.Number; Number; Number
APPLy:RAMP <Freq>,<Amp>,<Offset>Apply Ramp. Sets ramp with the given frequency, amplitude and offset.Number; Number; Number
APPLy:PULSe <Freq>,<Amp>,<Offset>Apply Pulse. Sets pulse with the given frequency, amplitude and offset.Number; Number; Number
APPLy:NOISe DEF,<Amp>,<Offset>Apply Noise. Sets noise with the given amplitude and offset.Number; Number
APPLy:USER <Freq>,<Amp>,<Offset>Apply User. Sets the user/arb waveform with the given frequency, amplitude and offset.Number; Number; Number

Burst (BURSt) (6)

CommandWhat it doesArguments
BURSt:STATe ONEnable Burst. Enables burst mode.None
BURSt:STATe OFFDisable Burst. Disables burst mode.None
BURSt:MODE <Mode>Set Burst Mode. Sets the burst mode.Text: TRIGgered,GATed
BURSt:NCYCles <N>Set Burst Cycles. Sets the number of cycles per burst.Number
BURSt:INTernal:PERiod <Sec>Set Burst Period. Sets the internal burst period.Number
BURSt:PHASe <Deg>Set Burst Phase. Sets the burst start phase.Number

Function (FUNCtion) (5)

CommandWhat it doesArguments
FUNCtion <Shape>Set Function. Sets the output waveform shape.Text: SINusoid,SQUare,RAMP,PULSe,NOISe,DC,USER
FUNCtion?Read Function. Reads the output waveform shape.None
FUNCtion:RAMP:SYMMetry <Pct>Set Ramp Symmetry. Sets the ramp symmetry percentage.Number
FUNCtion:SQUare:DCYCle <Pct>Set Square Duty Cycle. Sets the square-wave duty cycle percentage.Number
FUNCtion:USER <Name>Select Arb Waveform. Selects the active arbitrary waveform.Text

AM subsystem (5)

CommandWhat it doesArguments
AM:STATe ONEnable AM. Enables AM modulation.None
AM:STATe OFFDisable AM. Disables AM modulation.None
AM:DEPTh <Pct>Set AM Deviation. Sets the AM depth percentage.Number
AM:SOURce <Src>Set AM Source. Sets the AM modulation source.Text: INTernal,EXTernal
AM:INTernal:FREQuency <Freq>Set AM Int Freq. Sets the internal AM modulating frequency.Number

FM subsystem (5)

CommandWhat it doesArguments
FM:STATe ONEnable FM. Enables FM modulation.None
FM:STATe OFFDisable FM. Disables FM modulation.None
FM:DEViation <Freq>Set FM Deviation. Sets the FM frequency deviation.Number
FM:SOURce <Src>Set FM Source. Sets the FM modulation source.Text: INTernal,EXTernal
FM:INTernal:FREQuency <Freq>Set FM Int Freq. Sets the internal FM modulating frequency.Number

PM subsystem (5)

CommandWhat it doesArguments
PM:STATe ONEnable PM. Enables PM modulation.None
PM:STATe OFFDisable PM. Disables PM modulation.None
PM:DEViation <Deg>Set PM Deviation. Sets the PM phase deviation.Number
PM:SOURce <Src>Set PM Source. Sets the PM modulation source.Text: INTernal,EXTernal
PM:INTernal:FREQuency <Freq>Set PM Int Freq. Sets the internal PM modulating frequency.Number

System (SYSTem) (5)

CommandWhat it doesArguments
SYSTem:BEEPer:STATe ONEnable Beeper. Enables the beeper.None
SYSTem:BEEPer:STATe OFFDisable Beeper. Disables the beeper.None
SYSTem:BEEPerBeep Now. Sounds the beeper once.None
SYSTem:ERRor?Read Error. Reads and clears the next error-queue entry.None
SYSTem:VERSion?Read SCPI Version. Returns the SCPI version.None

PULS subsystem (4)

CommandWhat it doesArguments
PULSe:WIDTh <Sec>Set Pulse Width. Sets the pulse width in seconds.Number
PULSe:PERiod <Sec>Set Pulse Period. Sets the pulse period in seconds.Number
PULSe:DCYCle <Pct>Set Pulse Duty Cycle. Sets the pulse duty cycle percentage.Number
PULSe:TRANsition <Sec>Set Pulse Edge Time. Sets the pulse edge transition time.Number

FSK subsystem (4)

CommandWhat it doesArguments
FSKey:STATe ONEnable FSK. Enables FSK modulation.None
FSKey:STATe OFFDisable FSK. Disables FSK modulation.None
FSKey:FREQuency <Freq>Set FSK Hop Freq. Sets the FSK hop frequency.Number
FSKey:INTernal:RATE <Rate>Set FSK Rate. Sets the FSK internal rate.Number

Sweep (SWEep) (4)

CommandWhat it doesArguments
SWEep:STATe ONEnable Sweep. Enables the frequency sweep.None
SWEep:STATe OFFDisable Sweep. Disables the frequency sweep.None
SWEep:TIME <Sec>Set Sweep Time. Sets the sweep time in seconds.Number
SWEep:SPACing <Type>Set Sweep Spacing. Sets the sweep spacing.Text: LINear,LOGarithmic

PWM subsystem (3)

CommandWhat it doesArguments
PWM:STATe ONEnable PWM. Enables PWM modulation.None
PWM:STATe OFFDisable PWM. Disables PWM modulation.None
PWM:DEViation <Sec>Set PWM Deviation. Sets the PWM width deviation.Number

Trigger (TRIGger) (3)

CommandWhat it doesArguments
TRIGger:SOURce <Src>Set Trigger Source. Sets the trigger source.Text: IMMediate,EXTernal,BUS
TRIGger:SLOPe <Slope>Set Trigger Slope. Sets the external trigger slope.Text: POSitive,NEGative
TRIGgerTrigger Now. Issues an immediate trigger.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (9)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*TST?Self Test. Runs the self-test and returns 0 for pass.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete.None
*TRGTrigger Bus. Generates a bus trigger.None
*SAV <Slot>Save State Slot. Stores the current state to a memory slot (0 to 4).Number
*RCL <Slot>Recall State Slot. Recalls a state from a memory slot (0 to 4).Number

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Keithley's programming documentation for the 3390 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Keithley's programming manual: check it before you rely on an edge case. Last updated July 8, 2026.

Frequently asked questions

Does the Keithley 3390 support SCPI remote control?

Yes. The Keithley 3390 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 88 SCPI commands for it: 10 queries that read values or state, and 78 settings and actions.

How do I control the Keithley 3390 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut ON and OUTPut?.

Which command reads a value from the Keithley 3390?

OUTPut? (read output state). Reads whether the output is on. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Keithley 3390 without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Keithley 3390 through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.