In TestFlow's instrument library, the Aim-TTi CPX400DP takes 33 SCPI commands, 16 of them queries, and the Rohde & Schwarz HMC8043 takes 70 SCPI commands, 28 of them queries. That is 37 more on the HMC8043. Counting distinct command headers (the command path without its arguments), 2 are accepted by both, 26 exist only on the CPX400DP, and 61 only on the HMC8043. 7% of the CPX400DP's command headers also exist on the HMC8043.
Only the CPX400DP has OP1, OP2, V1, V2, V1O, and V2O and 10 more. Only the HMC8043 has VOLTage, OUTPut, FUSE, SYSTem, CURRent, and POWer and 4 more.
Both libraries synchronise with *OPC?. Only the HMC8043 library has an error-queue read (SYSTem:ERRor?); the CPX400DP library has none.
TestFlow's library gives the MX100QP, MX100TP, MX103QP, MX180TP, PL303QMDP, PL303QMTP, QL355TP, QL564TP, and QPX600DP the same command set as the CPX400DP, so the CPX400DP column applies to them too.
Describe the test; TestFlow's agent uses these command sets to drive your Aim-TTi CPX400DP or Rohde & Schwarz HMC8043 and writes the report from the measured results.
Counts come from TestFlow's instrument library, the command sets its AI agent uses to drive each instrument. A distinct command header is the command path without its arguments, so :OUTPut ON and :OUTPut OFF count once.
| Aim-TTi CPX400DP | Rohde & Schwarz HMC8043 | |
|---|---|---|
| Commands in TestFlow's library | 33 | 70 |
| Queries (read a value or state) | 16 | 28 |
| Settings and actions | 17 | 42 |
| Subsystems | 11 | 11 |
| Distinct command headers | 28 | 63 |
| Headers the other lacks | 26 | 61 |
| Command language | SCPI | SCPI |
| Operation complete | *OPC? | *OPC? |
| Error queue | Not in library | SYSTem:ERRor? |
| Models on this command set | CPX400DP, MX100QP, MX100TP, MX103QP, MX180TP, PL303QMDP, PL303QMTP, QL355TP, QL564TP, QPX600DP | HMC8043 |
2 command headers are in both libraries.
| Command | What it does |
|---|---|
| *IDN? | Identify. Returns instrument identification string (manufacturer model serial firmware) |
| *RST | Reset. Resets the instrument to factory default settings |
26 command headers in the CPX400DP library have no match in the HMC8043 library. Below are 12 of them from the 6 largest subsystems; the full list is in the Aim-TTi CPX400DP command reference.
| Command | What it does |
|---|---|
| I1 <Amp> | Set Current Ch1. Sets the current limit on channel 1 in Amps (0 to 20A, resolution 1mA) |
| I1? | Read Set Current Ch1. Returns the set current limit of channel 1 in Amps |
| Command | What it does |
|---|---|
| I2 <Amp> | Set Current Ch2. Sets the current limit on channel 2 in Amps (0 to 20A, resolution 1mA) |
| I2? | Read Set Current Ch2. Returns the set current limit of channel 2 in Amps |
| Command | What it does |
|---|---|
| OCP1 <Amp> | Set OCP Ch1. Sets the over-current protection trip level on channel 1 in Amps (resolution 10mA) |
| OCP1? | Read OCP Ch1. Returns the set OCP level of channel 1 in Amps |
| Command | What it does |
|---|---|
| OCP2 <Amp> | Set OCP Ch2. Sets the over-current protection trip level on channel 2 in Amps (resolution 10mA) |
| OCP2? | Read OCP Ch2. Returns the set OCP level of channel 2 in Amps |
| Command | What it does |
|---|---|
| OP1 1 | Turn On Ch1. Turns on output channel 1 |
| OP1? | Read State Ch1. Returns the output state of channel 1 (1=ON 0=OFF) |
| Command | What it does |
|---|---|
| OP2 1 | Turn On Ch2. Turns on output channel 2 |
| OP2? | Read State Ch2. Returns the output state of channel 2 (1=ON 0=OFF) |
61 command headers in the HMC8043 library have no match in the CPX400DP library. Below are 24 of them from the 6 largest subsystems; the full list is in the Rohde & Schwarz HMC8043 command reference.
| Command | What it does |
|---|---|
| VOLTage <Voltage> | Set Voltage. Voltage setpoint of the selected channel (manual p.26). |
| VOLTage? | Read Voltage Setpoint. Return the selected channel's voltage setpoint in V (manual p.26). |
| VOLTage:STEP <Step> | Set Voltage Step. Step size of Voltage_Up and Voltage_Down (manual p.27). |
| VOLTage:PROTection <State> | Set OVP. Turn the selected channel's over-voltage protection on or off (manual p.34). |
| Command | What it does |
|---|---|
| FUSE <State> | Set Fuse. Turn the selected channel's electronic fuse on or off (manual p.32). |
| FUSE? | Read Fuse. Return 1 when the selected channel's fuse is on, else 0 (manual p.32). |
| FUSE:DELay <Delay> | Set Fuse Delay. Delay before the selected channel's fuse trips (manual p.32). |
| FUSE:DELay? | Read Fuse Delay. Return the selected channel's fuse delay in s (manual p.33). |
| Command | What it does |
|---|---|
| SYSTem:ERRor? | Read Error. Read and remove the oldest error, e.g. 0,"No error" or -102,"Syntax error" (manual p.23). |
| SYSTem:VERSion? | Read Version. Return the firmware version and the SCPI version (manual p.23). |
| SYSTem:REMote | Remote. Switch to remote control (manual p.23). |
| SYSTem:LOCal | Local. Return to front-panel control; also the only way to unlock after Remote_Lock (manual p.23). |
| Command | What it does |
|---|---|
| *CLS | Clear Status. Clear the status registers and the error queue (manual p.19). |
| *OPC? | Operation Complete. Return 1 once every previous command has finished (manual p.20). |
| *WAI | Wait. Hold further commands until every previous one has been executed (manual p.21). |
| *TST? | Self Test. Run the self-test and return its result, 0 when it passed (manual p.21). |
| Command | What it does |
|---|---|
| MEASure:VOLTage? | Measure Voltage. Return the voltage measured at the selected channel's output in V (manual p.38). |
| MEASure:CURRent? | Measure Current. Return the current measured at the selected channel's output in A (manual p.38). |
| MEASure:POWer? | Measure Power. Return the power measured at the selected channel's output in W (manual p.38). |
| MEASure:ENERgy:STATe <State> | Set Energy Meter. Turn the selected channel's energy meter on or off (manual p.38). |
| Command | What it does |
|---|---|
| OUTPut ON | Output On. Turn the selected channel's output on together with the master output (manual p.30). |
| OUTPut? | Read Output. Return 1 when the selected channel's output is on, else 0 (manual p.30). |
| OUTPut:CHANnel ON | Channel Output On. Arm the selected channel; it outputs once the master output is on (manual p.30). |
| OUTPut:CHANnel? | Read Channel Output. Return 1 when the selected channel is armed, else 0 (manual p.31). |
With PyVISA and any VISA backend, this opens both instruments, identifies them, sends one setting, and reads one value from each. For the setting, the two libraries have no common command with a worked example on both, so each instrument uses its own: OP1 1 on the CPX400DP and VOLTage UP on the HMC8043. For the reading, the two libraries have no common command with a worked example on both, so each instrument uses its own: OP1? on the CPX400DP and MEASure:VOLTage? on the HMC8043. For the basics, see the PyVISA tutorial.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find both VISA addresses
a = rm.open_resource("PASTE_CPX400DP_ADDRESS") # Aim-TTi CPX400DP
b = rm.open_resource("PASTE_HMC8043_ADDRESS") # Rohde & Schwarz HMC8043
for inst in (a, b):
inst.timeout = 5000 # ms
print(inst.query("*IDN?"))
# No shared setting with an example on both, so each uses its own command
a.write("OP1 1") # Turn On Ch1
b.write("VOLTage UP") # Voltage Up
# No shared reading with an example on both, so each uses its own command
print(a.query("OP1?")) # Read State Ch1
print(b.query("MEASure:VOLTage?")) # Measure Voltage
a.close()
b.close()Describe the test; TestFlow's agent uses these command sets to drive your Aim-TTi CPX400DP or Rohde & Schwarz HMC8043 and writes the report from the measured results.
In TestFlow's library the CPX400DP has 33 SCPI commands and the HMC8043 has 70 SCPI commands. 2 command headers are common to both, 26 are only on the CPX400DP (mostly I1 and I2), and 61 are only on the HMC8043 (mostly VOLTage and FUSE).
Partly. 2 command headers are accepted by both. 87 are not, for example I1 on the CPX400DP and VOLTage on the HMC8043, so a script that uses those needs a separate branch for each instrument.
The HMC8043: 33 commands for the CPX400DP against 70 for the HMC8043 in TestFlow's library. Of those, 16 on the CPX400DP and 28 on the HMC8043 are queries that read a value or state, and the library splits them into 11 and 11 subsystems.
Both libraries synchronise with *OPC?. Only the HMC8043 library has an error-queue read (SYSTem:ERRor?); the CPX400DP library has none. Each command named here is listed in the tables on this page and on each instrument's command reference.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.