Power Supply · SCPI command comparison

Keysight E36311A vs Rohde & Schwarz HMC8043: SCPI commands and remote control compared

In TestFlow's instrument library, the Keysight E36311A takes 26 SCPI commands, 9 of them queries, and the Rohde & Schwarz HMC8043 takes 70 SCPI commands, 28 of them queries. That is 44 more on the HMC8043. Counting distinct command headers (the command path without its arguments), 13 are accepted by both, 5 exist only on the E36311A, and 50 only on the HMC8043. 72% of the E36311A's command headers also exist on the HMC8043.

Both libraries have commands under OUTPut, MEASure, and SYSTem. Only the E36311A has SOURce. Only the HMC8043 has VOLTage, FUSE, CURRent, POWer, INSTrument, and DISPlay and 1 more.

Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?.

TestFlow's library gives the E36312A the same command set as the E36311A, so the E36311A column applies to it too.

E36311A commands
26
HMC8043 commands
70
Shared headers
13
Unique headers
55

Run this on your bench

Describe the test; TestFlow's agent uses these command sets to drive your Keysight E36311A or Rohde & Schwarz HMC8043 and writes the report from the measured results.

Get started

E36311A vs HMC8043 at a glance

Counts come from TestFlow's instrument library, the command sets its AI agent uses to drive each instrument. A distinct command header is the command path without its arguments, so :OUTPut ON and :OUTPut OFF count once.

Keysight E36311ARohde & Schwarz HMC8043
Commands in TestFlow's library2670
Queries (read a value or state)928
Settings and actions1742
Subsystems811
Distinct command headers1863
Headers the other lacks550
Command languageSCPISCPI
Operation complete*OPC?*OPC?
Error queueSYSTem:ERRor?SYSTem:ERRor?
Models on this command setE36311A, E36312AHMC8043

Commands both accept

13 command headers are in both libraries. Here are 12, taken across subsystems. Where the HMC8043 library writes the command differently, its form is shown under the E36311A's.

CommandWhat it does
OUTPut ON,(@1)HMC8043: OUTPut ONTurn On CH1. Enables the output of channel 1.
MEASure:VOLTage? (@<Channel>)HMC8043: MEASure:VOLTage?Measure Voltage. Measures the output voltage of the selected channel in volts.
SYSTem:ERRor?Read Error. Reads the first message from the error queue.
*SAV <Slot>Save State. Saves the current instrument state to the specified storage slot.
OUTPut? (@<Channel>)HMC8043: OUTPut?Read Output State. Reads whether the selected channel output is ON or OFF.
MEASure:CURRent? (@<Channel>)HMC8043: MEASure:CURRent?Measure Current. Measures the output current of the selected channel in amps.
*RCL <Slot>Recall State. Recalls an instrument state from the specified storage slot.
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).
*RSTReset. Resets the instrument to its default state.
*CLSClear Status. Clears all event registers and the error queue.
*TST?Self Test. Runs the self-test and returns 0 for pass or 1 for failure.
*OPC?Operation Complete. Returns 1 when all pending operations are complete.

Only on the Keysight E36311A

5 command headers in the E36311A library have no match in the HMC8043 library. Below are 4 of them from the 1 largest subsystem; the full list is in the Keysight E36311A command reference.

SOURce (5 only on the E36311A)

CommandWhat it does
SOURce:VOLTage <Volt>,(@<Channel>)Set Voltage. Sets the output voltage of the selected channel in volts.
SOURce:VOLTage? (@<Channel>)Read Voltage Setting. Reads the set output voltage of the selected channel.
SOURce:CURRent <Amp>,(@<Channel>)Set Current. Sets the output current limit of the selected channel in amps.
SOURce:CURRent? (@<Channel>)Read Current Setting. Reads the set output current limit of the selected channel.

Only on the Rohde & Schwarz HMC8043

50 command headers in the HMC8043 library have no match in the E36311A library. Below are 24 of them from the 6 largest subsystems; the full list is in the Rohde & Schwarz HMC8043 command reference.

VOLTage (11 only on the HMC8043)

CommandWhat it does
VOLTage <Voltage>Set Voltage. Voltage setpoint of the selected channel (manual p.26).
VOLTage?Read Voltage Setpoint. Return the selected channel's voltage setpoint in V (manual p.26).
VOLTage:STEP <Step>Set Voltage Step. Step size of Voltage_Up and Voltage_Down (manual p.27).
VOLTage:PROTection <State>Set OVP. Turn the selected channel's over-voltage protection on or off (manual p.34).

FUSE (8 only on the HMC8043)

CommandWhat it does
FUSE <State>Set Fuse. Turn the selected channel's electronic fuse on or off (manual p.32).
FUSE?Read Fuse. Return 1 when the selected channel's fuse is on, else 0 (manual p.32).
FUSE:DELay <Delay>Set Fuse Delay. Delay before the selected channel's fuse trips (manual p.32).
FUSE:DELay?Read Fuse Delay. Return the selected channel's fuse delay in s (manual p.33).

POWer (6 only on the HMC8043)

CommandWhat it does
POWer:PROTection <State>Set OPP. Turn the selected channel's over-power protection on or off (manual p.36).
POWer:PROTection?Read OPP. Return 1 when the selected channel's OPP is on, else 0 (manual p.37).
POWer:PROTection:LEVel <Power>Set OPP Level. Over-power protection level of the selected channel (manual p.37).
POWer:PROTection:LEVel?Read OPP Level. Return the selected channel's OPP level in W (manual p.37).

SYSTem (6 only on the HMC8043)

CommandWhat it does
SYSTem:VERSion?Read Version. Return the firmware version and the SCPI version (manual p.23).
SYSTem:REMoteRemote. Switch to remote control (manual p.23).
SYSTem:LOCalLocal. Return to front-panel control; also the only way to unlock after Remote_Lock (manual p.23).
SYSTem:RWLockRemote Lock. Remote control with the front panel locked until Local is sent (manual p.23).

CURRent (4 only on the HMC8043)

CommandWhat it does
CURRent <Current>Set Current. Current limit of the selected channel; 0.1 mA steps below 1 A, 1 mA above (manual p.28).
CURRent?Read Current Setpoint. Return the selected channel's current setpoint in A (manual p.28).
CURRent:STEP <Step>Set Current Step. Step size of Current_Up and Current_Down (manual p.28).
CURRent:STEP?Read Current Step. Return the current step size in A (manual p.29).

MEASure (4 only on the HMC8043)

CommandWhat it does
MEASure:POWer?Measure Power. Return the power measured at the selected channel's output in W (manual p.38).
MEASure:ENERgy:STATe <State>Set Energy Meter. Turn the selected channel's energy meter on or off (manual p.38).
MEASure:ENERgy?Read Energy. Return the energy the selected channel has delivered since the meter started, in Ws; the meter must be on (manual p.38).
MEASure:ENERgy:RESetReset Energy Meter. Set the selected channel's energy meter back to zero (manual p.39).

Control both from Python

With PyVISA and any VISA backend, this opens both instruments, identifies them, sends one setting, and reads one value from each. For the setting, both libraries hold OUTPut (turn on ch1); the HMC8043 library writes it as OUTPut ON. For the reading, both libraries hold MEASure:VOLTage? (measure voltage); the HMC8043 library writes it as MEASure:VOLTage?. For the basics, see the PyVISA tutorial.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find both VISA addresses

a = rm.open_resource("PASTE_E36311A_ADDRESS")  # Keysight E36311A
b = rm.open_resource("PASTE_HMC8043_ADDRESS")  # Rohde & Schwarz HMC8043
for inst in (a, b):
    inst.timeout = 5000  # ms
    print(inst.query("*IDN?"))

# The same setting on both: Turn On CH1
a.write("OUTPut ON,(@1)")
b.write("OUTPut ON")

# The same reading on both: Measure Voltage
print(a.query("MEASure:VOLTage? (@1)"))
print(b.query("MEASure:VOLTage?"))

a.close()
b.close()

Run this on your bench

Describe the test; TestFlow's agent uses these command sets to drive your Keysight E36311A or Rohde & Schwarz HMC8043 and writes the report from the measured results.

Get started

Frequently asked questions

What is the difference between the Keysight E36311A and the Rohde & Schwarz HMC8043 for remote control?

In TestFlow's library the E36311A has 26 SCPI commands and the HMC8043 has 70 SCPI commands. 13 command headers are common to both, 5 are only on the E36311A (mostly SOURce), and 50 are only on the HMC8043 (mostly VOLTage and FUSE).

Can I use the same SCPI code for the Keysight E36311A and the Rohde & Schwarz HMC8043?

Partly. 13 command headers are accepted by both, including OUTPut, MEASure:VOLTage?, and SYSTem:ERRor?. 55 are not, for example SOURce:VOLTage on the E36311A and VOLTage on the HMC8043, so a script that uses those needs a separate branch for each instrument.

Which has more remote commands, the E36311A or the HMC8043?

The HMC8043: 26 commands for the E36311A against 70 for the HMC8043 in TestFlow's library. Of those, 9 on the E36311A and 28 on the HMC8043 are queries that read a value or state, and the library splits them into 8 and 11 subsystems.

How do the E36311A and HMC8043 signal operation complete and report errors?

Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?. Each command named here is listed in the tables on this page and on each instrument's command reference.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.