In TestFlow's instrument library, the Aim-TTi CPX400DP takes 33 SCPI commands, 16 of them queries, and the Rohde & Schwarz HMP2030 takes 26 SCPI commands, 9 of them queries. That is 7 more on the CPX400DP. Counting distinct command headers (the command path without its arguments), 2 are accepted by both, 26 exist only on the CPX400DP, and 8 only on the HMP2030. 7% of the CPX400DP's command headers also exist on the HMP2030.
Only the CPX400DP has OP1, OP2, V1, V2, V1O, and V2O and 10 more. Only the HMP2030 has INSTrument and SYSTem.
Both libraries synchronise with *OPC?. Only the HMP2030 library has an error-queue read (SYSTem:ERRor?); the CPX400DP library has none.
TestFlow's library gives the MX100QP, MX100TP, MX103QP, MX180TP, PL303QMDP, PL303QMTP, QL355TP, QL564TP, and QPX600DP the same command set as the CPX400DP, so the CPX400DP column applies to them too. TestFlow's library gives the HMP4030 the same command set as the HMP2030, so the HMP2030 column applies to it too.
Describe the test; TestFlow's agent uses these command sets to drive your Aim-TTi CPX400DP or Rohde & Schwarz HMP2030 and writes the report from the measured results.
Counts come from TestFlow's instrument library, the command sets its AI agent uses to drive each instrument. A distinct command header is the command path without its arguments, so :OUTPut ON and :OUTPut OFF count once.
| Aim-TTi CPX400DP | Rohde & Schwarz HMP2030 | |
|---|---|---|
| Commands in TestFlow's library | 33 | 26 |
| Queries (read a value or state) | 16 | 9 |
| Settings and actions | 17 | 17 |
| Subsystems | 11 | 6 |
| Distinct command headers | 28 | 10 |
| Headers the other lacks | 26 | 8 |
| Command language | SCPI | SCPI |
| Operation complete | *OPC? | *OPC? |
| Error queue | Not in library | SYSTem:ERRor? |
| Models on this command set | CPX400DP, MX100QP, MX100TP, MX103QP, MX180TP, PL303QMDP, PL303QMTP, QL355TP, QL564TP, QPX600DP | HMP2030, HMP4030 |
2 command headers are in both libraries.
| Command | What it does |
|---|---|
| *IDN? | Identify. Returns instrument identification string (manufacturer model serial firmware) |
| *RST | Reset. Resets the instrument to factory default settings |
26 command headers in the CPX400DP library have no match in the HMP2030 library. Below are 12 of them from the 6 largest subsystems; the full list is in the Aim-TTi CPX400DP command reference.
| Command | What it does |
|---|---|
| I1 <Amp> | Set Current Ch1. Sets the current limit on channel 1 in Amps (0 to 20A, resolution 1mA) |
| I1? | Read Set Current Ch1. Returns the set current limit of channel 1 in Amps |
| Command | What it does |
|---|---|
| I2 <Amp> | Set Current Ch2. Sets the current limit on channel 2 in Amps (0 to 20A, resolution 1mA) |
| I2? | Read Set Current Ch2. Returns the set current limit of channel 2 in Amps |
| Command | What it does |
|---|---|
| OCP1 <Amp> | Set OCP Ch1. Sets the over-current protection trip level on channel 1 in Amps (resolution 10mA) |
| OCP1? | Read OCP Ch1. Returns the set OCP level of channel 1 in Amps |
| Command | What it does |
|---|---|
| OCP2 <Amp> | Set OCP Ch2. Sets the over-current protection trip level on channel 2 in Amps (resolution 10mA) |
| OCP2? | Read OCP Ch2. Returns the set OCP level of channel 2 in Amps |
| Command | What it does |
|---|---|
| OP1 1 | Turn On Ch1. Turns on output channel 1 |
| OP1? | Read State Ch1. Returns the output state of channel 1 (1=ON 0=OFF) |
| Command | What it does |
|---|---|
| OP2 1 | Turn On Ch2. Turns on output channel 2 |
| OP2? | Read State Ch2. Returns the output state of channel 2 (1=ON 0=OFF) |
8 command headers in the HMP2030 library have no match in the CPX400DP library. Below are 6 of them from the 3 largest subsystems; the full list is in the Rohde & Schwarz HMP2030 command reference.
| Command | What it does |
|---|---|
| *SAV <Slot> | Save State. Saves the current instrument state to the specified storage slot. |
| *RCL <Slot> | Recall State. Recalls an instrument state from the specified storage slot. |
| *CLS | Clear Status. Clears all event registers and the error queue. |
| *TST? | Self Test. Runs the self-test and returns 0 for pass or 1 for failure. |
| Command | What it does |
|---|---|
| INSTrument:NSELect 1 ; ... | Turn On CH1. Enables the output of channel 1. |
| Command | What it does |
|---|---|
| SYSTem:ERRor? | Read Error. Reads the first message from the error queue. |
With PyVISA and any VISA backend, this opens both instruments, identifies them, sends one setting, and reads one value from each. For the setting, the two libraries have no common command with a worked example on both, so each instrument uses its own: OP1 1 on the CPX400DP. For the reading, the two libraries have no common command with a worked example on both, so each instrument uses its own: OP1? on the CPX400DP and SYSTem:ERRor? on the HMP2030. For the basics, see the PyVISA tutorial.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find both VISA addresses
a = rm.open_resource("PASTE_CPX400DP_ADDRESS") # Aim-TTi CPX400DP
b = rm.open_resource("PASTE_HMP2030_ADDRESS") # Rohde & Schwarz HMP2030
for inst in (a, b):
inst.timeout = 5000 # ms
print(inst.query("*IDN?"))
# No shared setting with an example on both, so each uses its own command
a.write("OP1 1") # Turn On Ch1
# No shared reading with an example on both, so each uses its own command
print(a.query("OP1?")) # Read State Ch1
print(b.query("SYSTem:ERRor?")) # Read Error
a.close()
b.close()Describe the test; TestFlow's agent uses these command sets to drive your Aim-TTi CPX400DP or Rohde & Schwarz HMP2030 and writes the report from the measured results.
In TestFlow's library the CPX400DP has 33 SCPI commands and the HMP2030 has 26 SCPI commands. 2 command headers are common to both, 26 are only on the CPX400DP (mostly I1 and I2), and 8 are only on the HMP2030 (mostly IEEE 488.2 common (*) and INSTrument).
Partly. 2 command headers are accepted by both. 34 are not, for example I1 on the CPX400DP and *SAV on the HMP2030, so a script that uses those needs a separate branch for each instrument.
The CPX400DP: 33 commands for the CPX400DP against 26 for the HMP2030 in TestFlow's library. Of those, 16 on the CPX400DP and 9 on the HMP2030 are queries that read a value or state, and the library splits them into 11 and 6 subsystems.
Both libraries synchronise with *OPC?. Only the HMP2030 library has an error-queue read (SYSTem:ERRor?); the CPX400DP library has none. Each command named here is listed in the tables on this page and on each instrument's command reference.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.