The Anritsu MT8860C radio test set is controlled remotely with SCPI commands. TestFlow's instrument library holds 158 commands for it, 65 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the MT8860C on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Anritsu MT8860C and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Anritsu MT8860C's VISA address
# Paste the address of your Anritsu MT8860C (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("MEASCFG 1,AUTOCFG") # Auto Configure
print(inst.query("MEASCFG? 1,PERPKTS")) # Read PER Packets
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Anritsu MT8860C and writes the report from the measured results.
Describe the test in a sentence, for example “auto configure on the MT8860C, then read per packets and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
158 commands in 8 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| MEASCFG 1,WLANSTD,<Value> | Set WLAN Standard. Sets the WLAN standard. | Text: A,B,G,N |
| MEASCFG? 1,WLANSTD | Read WLAN Standard. Reads the WLAN standard. | None |
| MEASCFG 1,MODE,<Value> | Set Measurement Mode. Sets the measurement mode (TXMODE or RXMODE). | Text: TXMODE,RXMODE |
| MEASCFG? 1,MODE | Read Measurement Mode. Reads the measurement mode (TXMODE or RXMODE). | None |
| MEASCFG 1,TESTMODE,<Value> | Set Test Mode. Sets the test mode (NETWORK = standard WLAN protocol connection, DIRECT = chipset control software). | Text: NETWORK,DIRECT |
| MEASCFG? 1,TESTMODE | Read Test Mode. Reads the test mode (NETWORK = standard WLAN protocol connection, DIRECT = chipset control software). | None |
| MEASCFG 1,CHANNELNUM,<Value> | Set Channel Number. Sets the primary channel number. | Number |
| MEASCFG? 1,CHANNELNUM | Read Channel Number. Reads the primary channel number. | None |
| MEASCFG 1,TXRATE,<Value> | Set TX Rate. Sets the reference radio transmission rate in Mbps. | Number: 1,2,5.5,6,9,11,12,18,24,36,48,54 |
| MEASCFG? 1,TXRATE | Read TX Rate. Reads the reference radio transmission rate in Mbps. | None |
| MEASCFG 1,TXPWR,<Value> | Set TX Power. Sets the MT8860C transmit power at the test port in dBm (-100 to 0). | Number: -100,0 |
| MEASCFG? 1,TXPWR | Read TX Power. Reads the MT8860C transmit power at the test port in dBm (-100 to 0). | None |
| MEASCFG 1,DUTPWR,<Value> | Set DUT Power. Sets the expected DUT transmit power in dBm (-30 to +30). | Number: -30,30 |
| MEASCFG? 1,DUTPWR | Read DUT Power. Reads the expected DUT transmit power in dBm (-30 to +30). | None |
| MEASCFG 1,NUMMEAS,<Value> | Set Number Of Measurements. Sets the number of measurements (triggers) included in Tx results (1 to 1000). | Number: 1,1000 |
| MEASCFG? 1,NUMMEAS | Read Number Of Measurements. Reads the number of measurements (triggers) included in Tx results (1 to 1000). | None |
| MEASCFG 1,PKTLEN,<Value> | Set Packet Length. Sets the packet length in bytes (Rx mode 60 to 1500). | Number |
| MEASCFG? 1,PKTLEN | Read Packet Length. Reads the packet length in bytes (Rx mode 60 to 1500). | None |
| MEASCFG 1,PKTTYPE,<Value> | Set Packet Type. Sets the packet type transmitted by the MT8860C. | Text: UNICAST,BROADCAST |
| MEASCFG? 1,PKTTYPE | Read Packet Type. Reads the packet type transmitted by the MT8860C. | None |
| MEASCFG 1,PAYLOAD,<Value> | Set Payload. Sets the payload data pattern. | Text: ZEROS,0101,1010,PN7,RANDOM,COUNT |
| MEASCFG? 1,PAYLOAD | Read Payload. Reads the payload data pattern. | None |
| MEASCFG 1,PREAMBLE,<Value> | Set Preamble. Sets the preamble type of the reference radio (802.11b/g/a). | Text: LONG,SHORT |
| MEASCFG? 1,PREAMBLE | Read Preamble. Reads the preamble type of the reference radio (802.11b/g/a). | None |
| MEASCFG 1,PERPKTS,<Value> | Set PER Packets. Sets the number of packets for the PER test. | Number |
| MEASCFG? 1,PERPKTS | Read PER Packets. Reads the number of packets for the PER test. | None |
| MEASCFG 1,PERDELAY,<Value> | Set PER Delay. Sets the PER measurement delay in s. | Number |
| MEASCFG? 1,PERDELAY | Read PER Delay. Reads the PER measurement delay in s. | None |
| MEASCFG 1,FRAMETYPE,<Value> | Set Frame Type. Sets the frame type analysed in network mode. | Text: DATA,ACK |
| MEASCFG? 1,FRAMETYPE | Read Frame Type. Reads the frame type analysed in network mode. | None |
| MEASCFG 1,RANGE,<Value> | Set Range. Sets the input range hold. | Text: AUTO,1,1L,2,2L,3,3L |
| MEASCFG? 1,RANGE | Read Range. Reads the input range hold. | None |
| MEASCFG 1,AUTORNGMODE,<Value> | Set Auto Range Mode. Sets the auto ranging mode. | Text: LOW,HIGH |
| MEASCFG? 1,AUTORNGMODE | Read Auto Range Mode. Reads the auto ranging mode. | None |
| MEASCFG 1,RFOPT,<Value> | Set RF Optimization. Sets the RF optimization mode. | Text: LOWNOISE,LOWACP |
| MEASCFG? 1,RFOPT | Read RF Optimization. Reads the RF optimization mode. | None |
| MEASCFG 1,RADIOSEL,<Value> | Set Radio Selection. Sets the reference radio (internal or external). | Text: INT,EXT |
| MEASCFG? 1,RADIOSEL | Read Radio Selection. Reads the reference radio (internal or external). | None |
| MEASCFG 1,LEVMODE,<Value> | Set Leveling Mode. Sets the levelling mode for external reference radio Rx tests. | Text: NORMAL,PAYLOAD |
| MEASCFG? 1,LEVMODE | Read Leveling Mode. Reads the levelling mode for external reference radio Rx tests. | None |
| MEASCFG 1,OBWPCT,<Value> | Set OBW Percentage. Sets the occupied bandwidth power percentage (0.0 to 100.0). | Number: 0,100 |
| MEASCFG? 1,OBWPCT | Read OBW Percentage. Reads the occupied bandwidth power percentage (0.0 to 100.0). | None |
| MEASCFG 1,PDPCT,<Value> | Set Power Distribution Percentage. Sets the power distribution percentage (0.0 to 100.0). | Number: 0,100 |
| MEASCFG? 1,PDPCT | Read Power Distribution Percentage. Reads the power distribution percentage (0.0 to 100.0). | None |
| MEASCFG 1,TXINTERVAL,<Value> | Set TX Interval. Sets the frame transmission interval for network Rx tests in ms (0 to 65535). | Number: 0,65535 |
| MEASCFG? 1,TXINTERVAL | Read TX Interval. Reads the frame transmission interval for network Rx tests in ms (0 to 65535). | None |
| MEASCFG 1,PLINTERVAL,<Value> | Set Loopback Interval. Sets the packet loopback interval for network Tx tests in ms (5 to 50). | Number: 5,50 |
| MEASCFG? 1,PLINTERVAL | Read Loopback Interval. Reads the packet loopback interval for network Tx tests in ms (5 to 50). | None |
| MEASCFG 1,IFINTERVAL,<Value> | Set Inter Frame Interval. Sets the inter frame interval in us. | Number |
| MEASCFG? 1,IFINTERVAL | Read Inter Frame Interval. Reads the inter frame interval in us. | None |
| MEASCFG 1,PRETRG,<Value> | Set Pre Trigger. Sets the pre trigger time in s. | Number |
| MEASCFG? 1,PRETRG | Read Pre Trigger. Reads the pre trigger time in s. | None |
| MEASCFG 1,MACADDR,<Value> | Set MAC Address. Sets the DUT MAC address (12 hex characters). | Text |
| MEASCFG? 1,MACADDR | Read MAC Address. Reads the DUT MAC address (12 hex characters). | None |
| MEASCFG 1,DUTIP,<Value> | Set DUT IP. Sets the DUT IP address. | Text |
| MEASCFG? 1,DUTIP | Read DUT IP. Reads the DUT IP address. | None |
| MEASCFG 1,NWTYPE,<Value> | Set Network Type. Sets the network type. | Text: ADHOC,AP,STA |
| MEASCFG? 1,NWTYPE | Read Network Type. Reads the network type. | None |
| MEASCFG 1,BEACONINT,<Value> | Set Beacon Interval. Sets the beacon interval. | Number |
| MEASCFG? 1,BEACONINT | Read Beacon Interval. Reads the beacon interval. | None |
| MEASCFG 1,OPERRATESET,<Value> | Set Operational Rate Set. Sets the operational rate set. | Text: ALL,SINGLE |
| MEASCFG? 1,OPERRATESET | Read Operational Rate Set. Reads the operational rate set. | None |
| MEASCFG 1,IPPROP,<Value> | Set IP Properties. Sets the WLAN IP property mode. | Text: AUTO,MANUAL |
| MEASCFG? 1,IPPROP | Read IP Properties. Reads the WLAN IP property mode. | None |
| MEASCFG 1,TRGSRC,FR | Set Trigger Source Free Run. Sets the trigger source to free run. | None |
| MEASCFG 1,TRGSRC,RF,<Power>,<Edge> | Set Trigger Source RF. Sets the trigger source to RF power level (-60 to +20 dBm) with edge. | Number: -60,20; Text: RISE,FALL |
| MEASCFG 1,TRGSRC,EXT,<Edge> | Set Trigger Source External. Sets the trigger source to the external BNC with edge. | Text: RISE,FALL |
| MEASCFG 1,TRGSRC,VIDEO,<Edge> | Set Trigger Source Video. Sets the trigger source to the digital power comparator with edge. | Text: RISE,FALL |
| MEASCFG? 1,TRGSRC | Read Trigger Source. Reads the trigger source configuration. | None |
| MEASCFG 1,GATE,<Gate>,<Delay>,<Width> | Set Gate. Configures a measurement gate: delay and width in s (max 5.95 ms). | Number: 1,2; Number; Number |
| MEASCFG? 1,GATE,<Gate> | Read Gate. Reads the measurement gate configuration. | Number: 1,2 |
| MEASCFG 1,NWSSID,<Length>,<SSID> | Set Network SSID. Sets the network SSID (length and text up to 32 characters). | Number: 1,32; Text |
| MEASCFG 1,IPPARMS,<IP>,<Subnet> | Set WLAN IP Parameters. Sets the MT8860C WLAN IP address and subnet mask. | Text; Text |
| MEASCFG 1,SFMASK,<Upper>,<Lower_Side>,<Lower_Middle> | Set Spectral Flatness Mask. Sets the spectrum flatness mask limits in dB (5 to -10). | Number; Number; Number |
| MEASCFG 1,PROFAVG,<Profile>,ON | Turn On Profile Average. Turns on averaging of a profile. | Text: POWER,SPECTRUM1 |
| MEASCFG 1,PROFAVG,<Profile>,OFF | Turn Off Profile Average. Turns off averaging of a profile. | Text: POWER,SPECTRUM1 |
| MEASCFG 1,PROFCAP,<Profile>,<Start>,<Stop> | Set Profile Capture. Sets the profile capture start and stop time in s. | Text: POWER; Number; Number |
| MEASCFG 1,AUTOCFG | Auto Configure. Automatically configures the measurement settings for the DUT signal. | None |
| MEASCFG 1,ABORT | Abort Measurement. Aborts the current measurement operation. | None |
| MEASCFG 1,SCAN | Scan Networks. Requests the internal reference radio to scan for available networks. | None |
| MEASCFG? 1,NWAVAIL | Read Networks Available. Reads the networks found by the scan. | None |
| MEASCFG? 1,NWINFO,<Index> | Read Network Info. Reads the SSID, RSSI and security info of a found network. | Number |
| MEASCFG 1,NWSELECT,<Index> | Select Network. Selects (connects to) a network from the scan list. | Number |
| MEASCFG 1,CLEARDHCP | Clear DHCP. Clears the IP addresses allocated by DHCP. | None |
| MEASCFG? 1,BSSID | Read BSSID. Reads the BSSID. | None |
| MEASCFG? 1,UNITMACADDR | Read Unit MAC Address. Reads the MAC address of the MT8860C. | None |
| MEASCFG? 1,STATUS | Read Measurement Status. Reads the measurement status. | None |
| MEASCFG? 1,ERRLST | Read Measurement Errors. Reads and clears the measurement system error list. | None |
| MEASCFG? 1,ERRMESS,<Error> | Read Error Message. Reads the description of an error number reported by ERRLST. | Text |
| MEASCFG? 1,RADIOERR | Read Radio Error. Reads the reference radio error report. | None |
| MEASCFG? 1,CFGCHG | Read Configuration Change. Reads the configuration change status. | None |
| MEASCFG 1,PATHSTATE,ON | Turn On Path Loss Table. Enables the path loss table. | None |
| MEASCFG 1,PATHSTATE,OFF | Turn Off Path Loss Table. Disables the path loss table. | None |
| MEASCFG 1,PATHADD,<Channel>,<Offset> | Add Path Loss Entry. Adds a path loss table element for a channel (offset in dB). | Number; Number |
| MEASCFG 1,PATHDEL,<Channel> | Delete Path Loss Entry. Deletes a path loss table element. | Number |
| MEASCFG? 1,PATHTBL | Read Path Loss Table. Reads all points of the path loss table. | None |
| MEASCFG 1,EVMCFG,MODE,<Mode> | Set EVM Analysis Mode. Sets whether EVM analysis lengths are set automatically or manually. | Text: AUTO,MANUAL |
| MEASCFG 1,EVMCFG,CHANEST,<Method> | Set EVM Channel Estimation. Sets the EVM channel estimation method. | Text: TRAINSEQ,FULLPKT |
| MEASCFG 1,EVMCFG,FILTER,<Filter> | Set EVM Filter. Sets the DSSS filter type. | Text: NONE,GAUSSIAN,RNYQUIST |
| MEASCFG 1,EVMCFG,ALPHA,<Alpha> | Set EVM Alpha. Sets the root Nyquist filter alpha (0.3 to 1.0). | Number: 0.3,1.0 |
| MEASCFG 1,EVMCFG,BT,<BT> | Set EVM BT. Sets the Gaussian filter BT (0.3 to 1.0). | Number: 0.3,1.0 |
| MEASCFG 1,EVMCFG,EVMDSSS,<Method> | Set EVM DSSS Method. Sets the DSSS EVM calculation method. | Text: USERDEF,1KSAMPLES |
| MEASCFG 1,EVMCFG,EVMCHIP,<Chips> | Set EVM DSSS Chips. Sets the DSSS EVM analysis length (220 to 11000 chips). | Number: 220,11000 |
| MEASCFG 1,EVMCFG,EVMSYM,<Symbols> | Set EVM OFDM Symbols. Sets the OFDM EVM analysis length (16 to 500 symbols). | Number: 16,500 |
| MEASCFG 1,EVMCFG,CHIPCLK,<Chips> | Set EVM Chip Clock Length. Sets the DSSS chip clock analysis length (3300 to 30250). | Number: 3300,30250 |
| MEASCFG 1,EVMCFG,SYMCLK,<Symbols> | Set EVM Symbol Clock Length. Sets the OFDM symbol clock analysis length (16 to 500). | Number: 16,500 |
| MEASCFG 1,EVMCFG,TRACKING,<Mode> | Set EVM Tracking. Sets the EVM pilot tracking type. | Text: PHASE,PHASEMAG |
| MEASCFG 1,SMSEL,<Mask> | Select Spectral Mask. Selects the DSSS spectral mask (1 to 5). | Number: 1,2,3,4,5 |
| MEASCFG 1,SMLIM,<Mask>,<Limit2>,<Limit1> | Set Spectral Mask Limits. Sets user mask limits in dB (35-22 MHz and 22-11 MHz sections). | Number: 2,3,4,5; Number; Number |
| MEASCFG 1,SMDEF,<Mask> | Default Spectral Mask. Sets a user spectral mask to the default values. | Number: 2,3,4,5 |
| MEASCFG 1,SIGGEN,MODE,<Mode> | Set SigGen Mode. Sets the signal generator output mode (CF framed, CS carrier suppression, CM modulated, CW). | Text: CF,CS,CM,CW |
| MEASCFG 1,SIGGEN,STATE,ENABLE | Enable SigGen. Starts signal generator transmission. | None |
| MEASCFG 1,SIGGEN,STATE,DISABLE | Disable SigGen. Stops signal generator transmission. | None |
| MEASCFG? 1,SIGGEN,STATE | Read SigGen State. Reads the signal generator state. | None |
| MEASCFG 1,MUTE,ENABLE | Enable Mute. Mutes the test port output (93 dB attenuation). | None |
| MEASCFG 1,MUTE,DISABLE | Disable Mute. Un-mutes the test port output. | None |
| MEASCFG 1,NCONFIG,FREQBAND,<Band> | Set 11n Frequency Band. Sets the 802.11n frequency band. | Text: 2PT4GHZ,5GHZ |
| MEASCFG 1,NCONFIG,GUARDINT,<Interval> | Set 11n Guard Interval. Sets the 802.11n guard interval. | Text: LONG,SHORT |
| MEASCFG 1,NCONFIG,MCSINDEX,<MCS> | Set 11n MCS Index. Sets the 802.11n MCS index. | Number: 0,1,2,3,4,5,6,7,32 |
| MEASCFG 1,NCONFIG,PPDUFORMAT,<Format> | Set 11n PPDU Format. Sets the 802.11n PPDU format. | Text: NONHT,HTMF,HTGF |
| MEASCFG 1,NCONFIG,PPDUTYPE,<Type> | Set 11n PPDU Type. Sets the 802.11n PPDU type. | Text: 20MHZ,40MHZ,40MHZD,40MHZL |
| MEASCFG? 1,NCONFIG,INFO | Read 11n Configuration. Reads the 802.11n configuration. | None |
| MEASCFG? 1,MEAS,<Measurements> | Measure. Requests measurements on captured packets; list of mnemonics e.g. AP,EV,FT,MS,OB,PP,SM,TT,PER. | Text: AP,CC,CF,CL,CO,CP,CS,EV,FE,FT,MS,OB,PD,PP,SC,SD,SF,SM,TT,FRR,PER |
| MEASCFG? 1,MEAS,AP | Measure Average Power. Measures average power (gate mean/high/low in dBm). | None |
| MEASCFG? 1,MEAS,EV | Measure EVM. Performs EVM analysis (rms/peak/min in % and dB). | None |
| MEASCFG? 1,MEAS,FT | Measure Frequency Tolerance. Measures the centre frequency error in Hz and ppm. | None |
| MEASCFG? 1,MEAS,SM | Measure Spectral Mask. Performs the spectral mask measurement. | None |
| MEASCFG? 1,MEAS,PER | Measure PER. Measures the packet error rate. | None |
| MEASCFG? 1,RDPROF,<Profile>,<Type>,<Format> | Read Profile. Reads profile data (trace) from the captured raw data. | Text: POWER,SPECTRUM1,SPECTRUM2,CCDF1,CCDF2,EVMCHAN,EVMTIME,CONSTELLATION,FLATNESS; Text: RAW,MEAN,HIGH,LOW,LAST; Text: ASCII,BINARY |
| Command | What it does | Arguments |
|---|---|---|
| SYSCFG REF,<Source> | Set Reference. Selects the internal or external 10 MHz reference. | Text: INT,EXT |
| SYSCFG? REF | Read Reference. Reads the 10 MHz reference setting. | None |
| SYSCFG BNC,<BNC>,<State> | Set BNC. Configures a BNC input/output. | Text: OUT1,OUT2,IN1,IN2; Text: VIDTRG,TXTRG,RFTRG,EXT,GOLDTX |
| SYSCFG GPIBADDR,<Address> | Set GPIB Address. Sets the GPIB address (1 to 30). | Number: 1,30 |
| SYSCFG LAN,MODE,<Mode> | Set LAN Mode. Sets the LAN IPv4 address mode (applied after power cycle). | Text: AUTO,MANUAL |
| SYSCFG LAN,ADDR,<IP>,<Subnet> | Set LAN Address. Sets the manual LAN IPv4 address and subnet mask. | Text; Text |
| SYSCFG? LAN | Read LAN. Reads the LAN IP properties in use. | None |
| SYSCFG? OPTIONS,<Instrument>,<Option> | Read Options. Reads enabled options (instrument 0 = platform, 1 = instrument; option 0 = all). | Number: 0,1; Number |
| SYSCFG? ERRLST | Read System Errors. Reads and clears the system error list. | None |
| SYSCFG? STERR | Read Startup Errors. Reads the start-up errors. | None |
| SYSCFG RST | Instrument Reset. Resets the measurement configurations to default settings. | None |
| SYSCFG FRST | Factory Reset. Resets all settings including path loss table, GPIB and LAN settings to factory defaults. | None |
| Command | What it does | Arguments |
|---|---|---|
| BOOTSTATUS? | Read Boot Status. Reads the start-up self test status (0 ready, 1 running, -1 failed). | None |
| Command | What it does | Arguments |
|---|---|---|
| SHUTDOWN | Shutdown. Performs the system shutdown sequence before powering down. | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *ESE <Mask> | Set Event Status Enable. Sets the event status enable register. | Number: 0,255 |
| *ESR? | Read Event Status Register. Reads the event status register. | None |
| *INE <Mask> | Set Instrument Status Enable. Sets the instrument status enable register. | Number: 0,255 |
| *INS? | Read Instrument Status. Reads the instrument status register. | None |
| *SRE <Mask> | Set Service Request Enable. Sets the service request enable register. | Number: 0,255 |
| *STB? | Read Status Byte. Reads the status byte register. | None |
| *IDN? | Identify. Returns the manufacturer, model number, serial number and software revision. | None |
| *RST | Reset. Resets the instrument. | None |
| *CLS | Clear Status. Clears the GPIB status bytes. | None |
| *TST? | Self Test. Runs the self test and returns the result. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *WAI | Wait To Continue. Waits until all pending operations are complete. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Anritsu's programming documentation for the MT8860C and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Anritsu's programming manual: check it before you rely on an edge case. Last updated September 27, 2026.
Yes. The Anritsu MT8860C accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 158 SCPI commands for it: 65 queries that read values or state, and 93 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, MEASCFG 1,AUTOCFG and MEASCFG? 1,PERPKTS.
MEASCFG? 1,PERPKTS (read per packets). Reads the number of packets for the PER test. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Anritsu MT8860C through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.