Radio Test Set · SCPI command reference

Anritsu MT8852B SCPI commands

The Anritsu MT8852B radio test set is controlled remotely with SCPI commands. TestFlow's instrument library holds 193 commands for it, 70 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the MT8852B on a real bench.

Commands
193
Queries
70
Subsystems
83
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Anritsu MT8852B and writes the report from the measured results.

Get started

Control the Anritsu MT8852B from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Anritsu MT8852B's VISA address

# Paste the address of your Anritsu MT8852B (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("SYSCFG AUTH,STATE,ON")  # Turn On Authentication
print(inst.query("OPMD?"))  # Read Operation Mode

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Anritsu MT8852B and writes the report from the measured results.

Get started

Run a MT8852B test without writing code

Describe the test in a sentence, for example “turn on authentication on the MT8852B, then read operation mode and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

193 commands in 83 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

SYSCFG subsystem (31)

CommandWhat it doesArguments
SYSCFG EUTADDR,<Address>Set EUT Address. Sets the EUT Bluetooth address (12 hex characters) when the address source is MANUAL.Text
SYSCFG? EUTADDRRead EUT Address. Reads the EUT Bluetooth address.None
SYSCFG EUTSRCE,<Source>Set EUT Address Source. Sets the EUT address source.Text: MANUAL,RS232,INQUIRY,USB,BLE2WIRE,USBADAPTOR,USBBLE2WIRE
SYSCFG? EUTSRCERead EUT Address Source. Reads the EUT address source.None
SYSCFG? EUTFEATRead EUT Features. Reads the EUT supported features (16 hex characters).None
SYSCFG? EUTNAMERead EUT Name. Reads the EUT user-friendly name.None
SYSCFG? BTADDRRead Tester BT Address. Reads the MT8852B Bluetooth address.None
SYSCFG CONFIG,FILTER,<Filter>Set Measurement Filter. Sets the measurement filter bandwidth for frequency tests.Text: 1.3MHZ,2MHZ
SYSCFG CONFIG,RANGE,<Range>Set Power Range. Sets the measurement power range (AUTO or 1 to 6).Text: AUTO,0,1,2,3,4,5,6
SYSCFG? CONFIG,RANGERead Power Range. Reads the measurement power range.None
SYSCFG CONFIG,LKTIMO,<Seconds>Set Link Timeout. Sets the link supervision timeout (1 to 40 s).Number: 1,40
SYSCFG CONFIG,MODINDEX,<Index>Set Tester Mod Index. Sets the tester modulation index (0.25 to 0.50).Number: 0.25,0.50
SYSCFG CONFIG,GPIB,<Address>Set GPIB Address. Sets the GPIB address (1 to 30).Number: 1,30
SYSCFG BNCOUTPUT,<Output1>,<Output2>Set BNC Output. Sets the rear panel BNC outputs.Text: TXON,TXDATA,RXDATA,CORRFIRED; Text: RXON,TXDATA,RXDATA,CORRFIRED
SYSCFG DISPSOUND,FOLTST,<Mode>Set Follow Test Display. Sets the follow test display mode.Text: OFF,SUM,EXT
SYSCFG AUTH,STATE,ONTurn On Authentication. Enables connection authentication.None
SYSCFG AUTH,STATE,OFFTurn Off Authentication. Disables connection authentication.None
SYSCFG AUTH,PINCODE,<PIN>Set PIN Code. Sets the authentication PIN code.Text
SYSCFG INQSET,NAME,ONTurn On Inquiry Name. Requests user-friendly names during inquiry.None
SYSCFG INQSET,NAME,OFFTurn Off Inquiry Name. Does not request user-friendly names during inquiry.None
SYSCFG INQSET,RNUM,<Count>Set Inquiry Responses. Sets the number of responses before inquiry termination (1 to 50).Number: 1,50
SYSCFG INQSET,TIMEOUT,<Seconds>Set Inquiry Timeout. Sets the inquiry timeout (5 to 60 s).Number: 5,60
SYSCFG PAGSET,PAGETO,<Seconds>Set Page Timeout. Sets the page timeout (2 to 30 s).Number: 2,30
SYSCFG SCPTSET,LOOPCNT,<Count>Set Loop Count. Sets the number of loops for test/script looping (2 to 100).Number: 2,100
SYSCFG SCPTSET,LPCONT,ONTurn On Loop Continuous. Loops the test/script continuously.None
SYSCFG SCPTSET,LPCONT,OFFTurn Off Loop Continuous. Stops continuous looping.None
SYSCFG SCPTSET,LPSTFAIL,ONTurn On Loop Stop On Fail. Stops looping on a failure.None
SYSCFG SCPTSET,LPSTFAIL,OFFTurn Off Loop Stop On Fail. Does not stop looping on a failure.None
SYSCFG? IDENTRead Tester Identity. Reads the tester identity (same as *IDN?).None
SYSCFG? VERNUMRead Firmware Versions. Reads the tester firmware version numbers.None
SYSCFG? HWINFORead Hardware Info. Reads the hardware information (PCB serial numbers and revisions).None

OPMD subsystem (3)

CommandWhat it doesArguments
OPMD <Mode>Set Operation Mode. Sets the operation mode of the instrument.Text: SCRIPT,SIGGEN,ESIGGEN,LESIGGEN,CWMEAS,ECWMEAS
OPMD STEST,<Test>Set Single Test Mode. Sets single test mode with the selected test.Text: OP,PC,EPC,MI,IC,CD,SS,MS,MP,ERP,ECM,EDP,EBS,EFS,EMP,LEOP,LEICD,LEMI,LESS,LEPRI,LEMP
OPMD?Read Operation Mode. Reads the operation mode in the form of the set command.None

SCPTCFG subsystem (3)

CommandWhat it doesArguments
SCPTCFG <Script>,<Test>,ONTurn On Script Test. Includes a test in the script.Number: 3,4,5,6,7,8,9,10; Text: OP,PC,EPC,MI,IC,CD,SS,MS,MP,ERP,ECM,EDP,EBS,EFS,EMP,LEOP,LEICD,LEMI,LESS,LEPRI,LEMP,STDTSTS,EDRTSTS,BLETSTS,PCTSTS,ALLTSTS
SCPTCFG <Script>,<Test>,OFFTurn Off Script Test. Removes a test from the script.Number: 3,4,5,6,7,8,9,10; Text: OP,PC,EPC,MI,IC,CD,SS,MS,MP,ERP,ECM,EDP,EBS,EFS,EMP,LEOP,LEICD,LEMI,LESS,LEPRI,LEMP,STDTSTS,EDRTSTS,BLETSTS,PCTSTS,ALLTSTS
SCPTCFG? <Script>Read Script Tests. Reads the ON/OFF list of tests in a script.Number: 1,2,3,4,5,6,7,8,9,10

OPCFG subsystem (3)

CommandWhat it doesArguments
OPCFG <Script>,<Variable>,<Value>Set Output Power Config. Sets a Output Power test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: LRXFREQ,MRXFREQ,HRXFREQ,HOPMODE,HOPPING,LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,NUMPKTS,PKTTYPE,TSTCTRL,AVGMXLIM,AVGMNLIM,PEAKLIM; Text
OPCFG? <Script>,<Variable>Read Output Power Config. Reads a Output Power test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: LRXFREQ,MRXFREQ,HRXFREQ,HOPMODE,HOPPING,LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,NUMPKTS,PKTTYPE,TSTCTRL,AVGMXLIM,AVGMNLIM,PEAKLIM
OPCFG <Script>,DEFAULTDefault Output Power Config. Sets the Output Power test to its default settings.Number: 3,4,5,6,7,8,9,10

PCCFG subsystem (3)

CommandWhat it doesArguments
PCCFG <Script>,<Variable>,<Value>Set Power Control Config. Sets a Power Control test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,LRXFREQ,MRXFREQ,HRXFREQ,NUMCYC,PKTTYPE,TSTCTRL,MXSTEPLIM,MNSTEPLIM,NUMPKTS,MINPWR,PWRDELAY; Text
PCCFG? <Script>,<Variable>Read Power Control Config. Reads a Power Control test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,LRXFREQ,MRXFREQ,HRXFREQ,NUMCYC,PKTTYPE,TSTCTRL,MXSTEPLIM,MNSTEPLIM,NUMPKTS,MINPWR,PWRDELAY
PCCFG <Script>,DEFAULTDefault Power Control Config. Sets the Power Control test to its default settings.Number: 3,4,5,6,7,8,9,10

EPCCFG subsystem (3)

CommandWhat it doesArguments
EPCCFG <Script>,<Variable>,<Value>Set Enhanced Power Control Config. Sets a Enhanced Power Control test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LRXFREQ,MRXFREQ,HRXFREQ,LTXFREQ,MTXFREQ,HTXFREQ,NUMCYC,NUMPKTS,PKTTYPE,DHXPKT,TSTCTRL,MXSTEPLIM,MNSTEPLIM,MXEPCLIM,MXRPTLIM,MINPWR; Text
EPCCFG? <Script>,<Variable>Read Enhanced Power Control Config. Reads a Enhanced Power Control test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LRXFREQ,MRXFREQ,HRXFREQ,LTXFREQ,MTXFREQ,HTXFREQ,NUMCYC,NUMPKTS,PKTTYPE,DHXPKT,TSTCTRL,MXSTEPLIM,MNSTEPLIM,MXEPCLIM,MXRPTLIM,MINPWR
EPCCFG <Script>,DEFAULTDefault Enhanced Power Control Config. Sets the Enhanced Power Control test to its default settings.Number: 3,4,5,6,7,8,9,10

ICCFG subsystem (3)

CommandWhat it doesArguments
ICCFG <Script>,<Variable>,<Value>Set Initial Carrier Config. Sets a Initial Carrier test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: HOPMODE,HOPPING,LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,LRXFREQ,MRXFREQ,HRXFREQ,NUMPKTS,TSTCTRL,MXPOSLIM,MXNEGLIM; Text
ICCFG? <Script>,<Variable>Read Initial Carrier Config. Reads a Initial Carrier test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: HOPMODE,HOPPING,LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,LRXFREQ,MRXFREQ,HRXFREQ,NUMPKTS,TSTCTRL,MXPOSLIM,MXNEGLIM
ICCFG <Script>,DEFAULTDefault Initial Carrier Config. Sets the Initial Carrier test to its default settings.Number: 3,4,5,6,7,8,9,10

CDCFG subsystem (3)

CommandWhat it doesArguments
CDCFG <Script>,<Variable>,<Value>Set Carrier Drift Config. Sets a Carrier Drift test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: HOPMODE,HOPPING,LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,LRXFREQ,MRXFREQ,HRXFREQ,NUMPKTS,PKTSIZE,TSTCTRL,DFT1LIM,DFT3LIM,DFT5LIM,DFTNPLIM,DFTRATE; Text
CDCFG? <Script>,<Variable>Read Carrier Drift Config. Reads a Carrier Drift test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: HOPMODE,HOPPING,LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,LRXFREQ,MRXFREQ,HRXFREQ,NUMPKTS,PKTSIZE,TSTCTRL,DFT1LIM,DFT3LIM,DFT5LIM,DFTNPLIM,DFTRATE
CDCFG <Script>,DEFAULTDefault Carrier Drift Config. Sets the Carrier Drift test to its default settings.Number: 3,4,5,6,7,8,9,10

SSCFG subsystem (3)

CommandWhat it doesArguments
SSCFG <Script>,<Variable>,<Value>Set Single Slot Sensitivity Config. Sets a Single Slot Sensitivity test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,LRXFREQ,MTXFREQ,MRXFREQ,HTXFREQ,HRXFREQ,HOPPING,NUMPKTS,TXPWR,DIRTYTX,DIRTYTAB,DRIFTS,BERLIM,FERLIM,PKTCOUNT; Text
SSCFG? <Script>,<Variable>Read Single Slot Sensitivity Config. Reads a Single Slot Sensitivity test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,LRXFREQ,MTXFREQ,MRXFREQ,HTXFREQ,HRXFREQ,HOPPING,NUMPKTS,TXPWR,DIRTYTX,DIRTYTAB,DRIFTS,BERLIM,FERLIM,PKTCOUNT
SSCFG <Script>,DEFAULTDefault Single Slot Sensitivity Config. Sets the Single Slot Sensitivity test to its default settings.Number: 3,4,5,6,7,8,9,10

MSCFG subsystem (3)

CommandWhat it doesArguments
MSCFG <Script>,<Variable>,<Value>Set Multi Slot Sensitivity Config. Sets a Multi Slot Sensitivity test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,LRXFREQ,MTXFREQ,MRXFREQ,HTXFREQ,HRXFREQ,HOPPING,NUMPKTS,TXPWR,DIRTYTX,DIRTYTAB,DRIFTS,PKTTYPE,BERLIM,FERLIM,PKTCOUNT; Text
MSCFG? <Script>,<Variable>Read Multi Slot Sensitivity Config. Reads a Multi Slot Sensitivity test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,LRXFREQ,MTXFREQ,MRXFREQ,HTXFREQ,HRXFREQ,HOPPING,NUMPKTS,TXPWR,DIRTYTX,DIRTYTAB,DRIFTS,PKTTYPE,BERLIM,FERLIM,PKTCOUNT
MSCFG <Script>,DEFAULTDefault Multi Slot Sensitivity Config. Sets the Multi Slot Sensitivity test to its default settings.Number: 3,4,5,6,7,8,9,10

MICFG subsystem (3)

CommandWhat it doesArguments
MICFG <Script>,<Variable>,<Value>Set Modulation Index Config. Sets a Modulation Index test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,LRXFREQ,MTXFREQ,MRXFREQ,HTXFREQ,HRXFREQ,NUMPKTS,PKTTYPE,TSTCTRL,F1AVGMIN,F1AVGMAX,F2MAXLIM,F1F2MAX,TOGGLE; Text
MICFG? <Script>,<Variable>Read Modulation Index Config. Reads a Modulation Index test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,LRXFREQ,MTXFREQ,MRXFREQ,HTXFREQ,HRXFREQ,NUMPKTS,PKTTYPE,TSTCTRL,F1AVGMIN,F1AVGMAX,F2MAXLIM,F1F2MAX,TOGGLE
MICFG <Script>,DEFAULTDefault Modulation Index Config. Sets the Modulation Index test to its default settings.Number: 3,4,5,6,7,8,9,10

MPCFG subsystem (3)

CommandWhat it doesArguments
MPCFG <Script>,<Variable>,<Value>Set Max Input Power Config. Sets a Max Input Power test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,LRXFREQ,MTXFREQ,MRXFREQ,HTXFREQ,HRXFREQ,NUMPKTS,TXPWR,BERLIM,FERLIM,PKTCOUNT; Text
MPCFG? <Script>,<Variable>Read Max Input Power Config. Reads a Max Input Power test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,LRXFREQ,MTXFREQ,MRXFREQ,HTXFREQ,HRXFREQ,NUMPKTS,TXPWR,BERLIM,FERLIM,PKTCOUNT
MPCFG <Script>,DEFAULTDefault Max Input Power Config. Sets the Max Input Power test to its default settings.Number: 3,4,5,6,7,8,9,10

ERPCFG subsystem (3)

CommandWhat it doesArguments
ERPCFG <Script>,<Variable>,<Value>Set EDR Relative Power Config. Sets a EDR Relative Power test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: NUMPKTS,DHXPKT,TSTCTRL,PTXLEV,HOPPING,HOPMODE,LRXFREQ,MRXFREQ,HRXFREQ,LTXFREQ,MTXFREQ,HTXFREQ,LFREQSEL,MFREQSEL,HFREQSEL,PDIFFLH,PDIFFLL,MINCHECK; Text
ERPCFG? <Script>,<Variable>Read EDR Relative Power Config. Reads a EDR Relative Power test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: NUMPKTS,DHXPKT,TSTCTRL,PTXLEV,HOPPING,HOPMODE,LRXFREQ,MRXFREQ,HRXFREQ,LTXFREQ,MTXFREQ,HTXFREQ,LFREQSEL,MFREQSEL,HFREQSEL,PDIFFLH,PDIFFLL,MINCHECK
ERPCFG <Script>,DEFAULTDefault EDR Relative Power Config. Sets the EDR Relative Power test to its default settings.Number: 3,4,5,6,7,8,9,10

ECMCFG subsystem (3)

CommandWhat it doesArguments
ECMCFG <Script>,<Variable>,<Value>Set EDR Carrier Modulation Config. Sets a EDR Carrier Modulation test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: NUMBLKS,DHXPKT,TSTCTRL,HOPPING,HOPMODE,LRXFREQ,MRXFREQ,HRXFREQ,LTXFREQ,MTXFREQ,HTXFREQ,LFREQSEL,MFREQSEL,HFREQSEL,INITFRQLH,INITFRQLL,FREQERLH,FREQERLL,BLKFRQLH,BLKFRQLL,LRMSDEVM,HRMSDEVM,LPKDEVM,HPKDEVM,LPCTDEVM,HPCTDEVM; Text
ECMCFG? <Script>,<Variable>Read EDR Carrier Modulation Config. Reads a EDR Carrier Modulation test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: NUMBLKS,DHXPKT,TSTCTRL,HOPPING,HOPMODE,LRXFREQ,MRXFREQ,HRXFREQ,LTXFREQ,MTXFREQ,HTXFREQ,LFREQSEL,MFREQSEL,HFREQSEL,INITFRQLH,INITFRQLL,FREQERLH,FREQERLL,BLKFRQLH,BLKFRQLL,LRMSDEVM,HRMSDEVM,LPKDEVM,HPKDEVM,LPCTDEVM,HPCTDEVM
ECMCFG <Script>,DEFAULTDefault EDR Carrier Modulation Config. Sets the EDR Carrier Modulation test to its default settings.Number: 3,4,5,6,7,8,9,10

EDPCFG subsystem (3)

CommandWhat it doesArguments
EDPCFG <Script>,<Variable>,<Value>Set EDR Differential Phase Config. Sets a EDR Differential Phase test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: NUMPKTS,DHXPKT,HOPPING,LTXFREQ,MTXFREQ,HTXFREQ,LFREQSEL,MFREQSEL,HFREQSEL,PCTPKT; Text
EDPCFG? <Script>,<Variable>Read EDR Differential Phase Config. Reads a EDR Differential Phase test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: NUMPKTS,DHXPKT,HOPPING,LTXFREQ,MTXFREQ,HTXFREQ,LFREQSEL,MFREQSEL,HFREQSEL,PCTPKT
EDPCFG <Script>,DEFAULTDefault EDR Differential Phase Config. Sets the EDR Differential Phase test to its default settings.Number: 3,4,5,6,7,8,9,10

EBSCFG subsystem (3)

CommandWhat it doesArguments
EBSCFG <Script>,<Variable>,<Value>Set EDR Sensitivity Config. Sets a EDR Sensitivity test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: DHXPKT,DIRTYTX,DIRTYTAB,DRIFTS,HOPPING,PKTCOUNT,THBITCNT,TTBITCNT,TXPWR,LRXFREQ,MRXFREQ,HRXFREQ,LTXFREQ,MTXFREQ,HTXFREQ,LFREQSEL,MFREQSEL,HFREQSEL,THERR,TTERR; Text
EBSCFG? <Script>,<Variable>Read EDR Sensitivity Config. Reads a EDR Sensitivity test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: DHXPKT,DIRTYTX,DIRTYTAB,DRIFTS,HOPPING,PKTCOUNT,THBITCNT,TTBITCNT,TXPWR,LRXFREQ,MRXFREQ,HRXFREQ,LTXFREQ,MTXFREQ,HTXFREQ,LFREQSEL,MFREQSEL,HFREQSEL,THERR,TTERR
EBSCFG <Script>,DEFAULTDefault EDR Sensitivity Config. Sets the EDR Sensitivity test to its default settings.Number: 3,4,5,6,7,8,9,10

EFSCFG subsystem (3)

CommandWhat it doesArguments
EFSCFG <Script>,<Variable>,<Value>Set EDR BER Floor Config. Sets a EDR BER Floor test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: DHXPKT,PKTCOUNT,HOPPING,THBITCNT,TTBITCNT,TXPWR,LRXFREQ,MRXFREQ,HRXFREQ,LTXFREQ,MTXFREQ,HTXFREQ,LFREQSEL,MFREQSEL,HFREQSEL,THERR,TTERR; Text
EFSCFG? <Script>,<Variable>Read EDR BER Floor Config. Reads a EDR BER Floor test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: DHXPKT,PKTCOUNT,HOPPING,THBITCNT,TTBITCNT,TXPWR,LRXFREQ,MRXFREQ,HRXFREQ,LTXFREQ,MTXFREQ,HTXFREQ,LFREQSEL,MFREQSEL,HFREQSEL,THERR,TTERR
EFSCFG <Script>,DEFAULTDefault EDR BER Floor Config. Sets the EDR BER Floor test to its default settings.Number: 3,4,5,6,7,8,9,10

EMPCFG subsystem (3)

CommandWhat it doesArguments
EMPCFG <Script>,<Variable>,<Value>Set EDR Max Input Power Config. Sets a EDR Max Input Power test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: DHXPKT,TXPWR,NUMBITS,HOPPING,PKTCOUNT,LRXFREQ,MRXFREQ,HRXFREQ,LTXFREQ,MTXFREQ,HTXFREQ,LFREQSEL,MFREQSEL,HFREQSEL,BERLIM; Text
EMPCFG? <Script>,<Variable>Read EDR Max Input Power Config. Reads a EDR Max Input Power test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: DHXPKT,TXPWR,NUMBITS,HOPPING,PKTCOUNT,LRXFREQ,MRXFREQ,HRXFREQ,LTXFREQ,MTXFREQ,HTXFREQ,LFREQSEL,MFREQSEL,HFREQSEL,BERLIM
EMPCFG <Script>,DEFAULTDefault EDR Max Input Power Config. Sets the EDR Max Input Power test to its default settings.Number: 3,4,5,6,7,8,9,10

LEOPCFG subsystem (3)

CommandWhat it doesArguments
LEOPCFG <Script>,<Variable>,<Value>Set BLE Output Power Config. Sets a BLE Output Power test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,LEPKTTYPE,NUMPKTS,AVGMXLIM,AVGMNLIM,PEAKLIM; Text
LEOPCFG? <Script>,<Variable>Read BLE Output Power Config. Reads a BLE Output Power test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,LEPKTTYPE,NUMPKTS,AVGMXLIM,AVGMNLIM,PEAKLIM
LEOPCFG <Script>,DEFAULTDefault BLE Output Power Config. Sets the BLE Output Power test to its default settings.Number: 3,4,5,6,7,8,9,10

LEICDCFG subsystem (3)

CommandWhat it doesArguments
LEICDCFG <Script>,<Variable>,<Value>Set BLE Carrier Drift Config. Sets a BLE Carrier Drift test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,LEPKTTYPE,NUMPKTS,MXPOSLIM,MXNEGLIM,DFTBLELIM,INITDFTBLERATE,DFTBLERATE; Text
LEICDCFG? <Script>,<Variable>Read BLE Carrier Drift Config. Reads a BLE Carrier Drift test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,LEPKTTYPE,NUMPKTS,MXPOSLIM,MXNEGLIM,DFTBLELIM,INITDFTBLERATE,DFTBLERATE
LEICDCFG <Script>,DEFAULTDefault BLE Carrier Drift Config. Sets the BLE Carrier Drift test to its default settings.Number: 3,4,5,6,7,8,9,10

LEMICFG subsystem (3)

CommandWhat it doesArguments
LEMICFG <Script>,<Variable>,<Value>Set BLE Modulation Config. Sets a BLE Modulation test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,LEPKTTYPE,NUMPKTS,F1AVGMIN,F1AVGMAX,F2MAXLIM,F1F2MAX,TOGGLE; Text
LEMICFG? <Script>,<Variable>Read BLE Modulation Config. Reads a BLE Modulation test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LTXFREQ,MTXFREQ,HTXFREQ,LEPKTTYPE,NUMPKTS,F1AVGMIN,F1AVGMAX,F2MAXLIM,F1F2MAX,TOGGLE
LEMICFG <Script>,DEFAULTDefault BLE Modulation Config. Sets the BLE Modulation test to its default settings.Number: 3,4,5,6,7,8,9,10

LESSCFG subsystem (3)

CommandWhat it doesArguments
LESSCFG <Script>,<Variable>,<Value>Set BLE Sensitivity Config. Sets a BLE Sensitivity test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LRXFREQ,MRXFREQ,HRXFREQ,LEPKTTYPE,NUMPKTS,TXPWR,FERLIM,FERLIMMODE,DIRTYTX,LETSTMODE; Text
LESSCFG? <Script>,<Variable>Read BLE Sensitivity Config. Reads a BLE Sensitivity test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LRXFREQ,MRXFREQ,HRXFREQ,LEPKTTYPE,NUMPKTS,TXPWR,FERLIM,FERLIMMODE,DIRTYTX,LETSTMODE
LESSCFG <Script>,DEFAULTDefault BLE Sensitivity Config. Sets the BLE Sensitivity test to its default settings.Number: 3,4,5,6,7,8,9,10

LEPRICFG subsystem (3)

CommandWhat it doesArguments
LEPRICFG <Script>,<Variable>,<Value>Set BLE PER Integrity Config. Sets a BLE PER Integrity test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: MRXFREQ,NUMCYC,LEPKTTYPE,NUMPKTS,PKTNUMMODE,TXPWR,FERLIMMODE,LOWPERLIM,HIGHPERLIM; Text
LEPRICFG? <Script>,<Variable>Read BLE PER Integrity Config. Reads a BLE PER Integrity test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: MRXFREQ,NUMCYC,LEPKTTYPE,NUMPKTS,PKTNUMMODE,TXPWR,FERLIMMODE,LOWPERLIM,HIGHPERLIM
LEPRICFG <Script>,DEFAULTDefault BLE PER Integrity Config. Sets the BLE PER Integrity test to its default settings.Number: 3,4,5,6,7,8,9,10

LEMPCFG subsystem (3)

CommandWhat it doesArguments
LEMPCFG <Script>,<Variable>,<Value>Set BLE Max Input Config. Sets a BLE Max Input test parameter or limit for the script (see manual chapters 12/13 for values).Number: 3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LRXFREQ,MRXFREQ,HRXFREQ,LEPKTTYPE,NUMPKTS,TXPWR,FERLIMMODE,FERLIM; Text
LEMPCFG? <Script>,<Variable>Read BLE Max Input Config. Reads a BLE Max Input test parameter or limit.Number: 1,2,3,4,5,6,7,8,9,10; Text: LFREQSEL,MFREQSEL,HFREQSEL,LRXFREQ,MRXFREQ,HRXFREQ,LEPKTTYPE,NUMPKTS,TXPWR,FERLIMMODE,FERLIM
LEMPCFG <Script>,DEFAULTDefault BLE Max Input Config. Sets the BLE Max Input test to its default settings.Number: 3,4,5,6,7,8,9,10

SCPTSEL subsystem (2)

CommandWhat it doesArguments
SCPTSEL <Script>Select Script. Selects the script to be executed (in single test mode the selected test is executed).Number: 1,2,3,4,5,6,7,8,9,10
SCPTSEL?Read Selected Script. Reads the selected script.None

SCPTTSTGP subsystem (2)

CommandWhat it doesArguments
SCPTTSTGP <Script>,<Group>,ONTurn On Script Test Group. Turns on all tests of a test group in the script.Number: 3,4,5,6,7,8,9,10; Text: STDTSTS,EDRTSTS,BLETSTS,ALLTSTS
SCPTTSTGP <Script>,<Group>,OFFTurn Off Script Test Group. Turns off all tests of a test group in the script.Number: 3,4,5,6,7,8,9,10; Text: STDTSTS,EDRTSTS,BLETSTS,ALLTSTS

SCPTNM subsystem (2)

CommandWhat it doesArguments
SCPTNM <Script>,<Name>Set Script Name. Sets the script name (up to 9 characters; scripts 3 to 10).Number: 3,4,5,6,7,8,9,10; Text
SCPTNM? <Script>Read Script Name. Reads the script name.Number: 1,2,3,4,5,6,7,8,9,10

SCRIPTMODE subsystem (2)

CommandWhat it doesArguments
SCRIPTMODE <Script>,<Mode>Set Script Mode. Determines how the tests within the script are run.Number: 3,4,5,6,7,8,9,10; Text: STANDARD,NULLPKT,SINGLEPAYLOAD
SCRIPTMODE? <Script>Read Script Mode. Reads the script mode.Number: 1,2,3,4,5,6,7,8,9,10

TXPWR subsystem (2)

CommandWhat it doesArguments
TXPWR <Script>,<Power>Set Script TX Power. Sets the default tester transmit power for a script (0.0 to -90.0 dBm in 0.1 dB steps).Number: 1,2,3,4,5,6,7,8,9,10; Number: 0,-90
TXPWR? <Script>Read Script TX Power. Reads the default tester transmit power of a script.Number: 1,2,3,4,5,6,7,8,9,10

EUTMAXPWR subsystem (2)

CommandWhat it doesArguments
EUTMAXPWR <Script>,ONTurn On EUT Max Power. Sets the EUT to maximum power at the start of a test.Number: 1,2,3,4,5,6,7,8,9,10
EUTMAXPWR <Script>,OFFTurn Off EUT Max Power. Disables setting the EUT to maximum power at the start of a test.Number: 1,2,3,4,5,6,7,8,9,10

TSTPAUSE subsystem (2)

CommandWhat it doesArguments
TSTPAUSE <Script>,ONTurn On Test Pause. Uses a Test Pause LMP test control between test control format changes.Number: 1,2,3,4,5,6,7,8,9,10
TSTPAUSE <Script>,OFFTurn Off Test Pause. Does not use a Test Pause LMP test control.Number: 1,2,3,4,5,6,7,8,9,10

LEPKTLEN subsystem (2)

CommandWhat it doesArguments
LEPKTLEN <Script>,<Length>Set BLE Packet Length. Sets the BLE data packet length (2 to 255 bytes).Number: 1,2,3,4,5,6,7,8,9,10; Number: 2,255
LEPKTLEN? <Script>Read BLE Packet Length. Reads the BLE data packet length.Number: 1,2,3,4,5,6,7,8,9,10

LOCK subsystem (2)

CommandWhat it doesArguments
LOCK <Script>,<Password>Lock Script. Locks a script so it cannot be altered (default password 1234).Number: 3,4,5,6,7,8,9; Number
LOCK? <Script>Read Script Lock. Returns TRUE if the script is locked.Number: 1,2,3,4,5,6,7,8,9

ORESULT subsystem (2)

CommandWhat it doesArguments
ORESULT SCRIPT,<Ext_Code>Read Script Results. Returns the summary results of the whole script (extension code 0 = standard).Number: 0,1,2
ORESULT TEST,<Ext_Code>,<Test>Read Test Results. Returns the summary results of a single test.Number: 0,1,2; Text: OP,PC,EPC,MI,IC,CD,SS,MS,MP,ERP,ECM,EDP,EBS,EFS,EMP,LEOP,LEICD,LEMI,LESS,LEPRI,LEMP,LEOP2M,LEICD2M,LEMI2M,LESS2M

SIGGEN subsystem (2)

CommandWhat it doesArguments
SIGGEN <Parameters>Set BR Signal Generator. Configures the Basic Rate signal generator: pattern,CHAN|FREQ,channel/freq,mod index,power,ON|OFF (e.g. DATA10101010,CHAN,3,0.26,-20,ON).Text
SIGGEN?Read Signal Generator. Reads the signal generator configuration.None

LESIGGEN subsystem (2)

CommandWhat it doesArguments
LESIGGEN <Parameters>Set BLE Signal Generator. Configures the BLE signal generator: syncword,pattern,spacing,channel,numpkts,power,dirty,altcrc,START|STOP (e.g. 71764129,PRBS9,625,2402,0,-20.0,ON,OFF,START).Text
LESIGGEN?Read BLE Signal Generator. Reads the BLE signal generator configuration.None

ECWMEAS subsystem (2)

CommandWhat it doesArguments
ECWMEAS?Read EDR CW Measurement. Reads the EDR CW measurement configuration.None
ECWMEAS <Modulation>,CHAN,<Channel>,<Gate_Width>Set EDR CW Measurement. Configures EDR CW measurement mode on a channel (-2 to 98) with gate width in s.Text: PI4,8DPSK; Number; Number

CONEUTNAME subsystem (2)

CommandWhat it doesArguments
CONEUTNAME <Script>,ONTurn On Connect EUT Name. Requests the EUT user-friendly name on connection.Number: 1,2,3,4,5,6,7,8,9,10
CONEUTNAME <Script>,OFFTurn Off Connect EUT Name. Does not request the EUT user-friendly name on connection.Number: 1,2,3,4,5,6,7,8,9,10

PATHOFF subsystem (2)

CommandWhat it doesArguments
PATHOFF <Script>,<Mode>Set Path Offset Mode. Sets the path offset mode for a script.Number: 1,2,3,4,5,6,7,8,9,10; Text: OFF,FIXED,TABLE
PATHOFF? <Script>Read Path Offset Mode. Reads the path offset mode.Number: 1,2,3,4,5,6,7,8,9,10

FIXEDOFF subsystem (2)

CommandWhat it doesArguments
FIXEDOFF <Script>,<Offset>Set Fixed Offset. Sets the fixed path offset value in dB.Number: 1,2,3,4,5,6,7,8,9,10; Number
FIXEDOFF? <Script>Read Fixed Offset. Reads the fixed path offset value.Number: 1,2,3,4,5,6,7,8,9,10

SCPTRST subsystem (1)

CommandWhat it doesArguments
SCPTRST <Script>Reset Script. Resets a script (1 to 10 or ALL) to its default values.Text: 1,2,3,4,5,6,7,8,9,10,ALL

LEPKTMODE subsystem (1)

CommandWhat it doesArguments
LEPKTMODE <Script>,<Mode>Set BLE Packet Mode. Sets the BLE data packet length mode.Number: 1,2,3,4,5,6,7,8,9,10; Text: AUTO,MANUAL

UNLOCK subsystem (1)

CommandWhat it doesArguments
UNLOCK <Script>,<Password>Unlock Script. Unlocks a locked script.Number: 3,4,5,6,7,8,9,10; Number

Run control (1)

CommandWhat it doesArguments
RUNRun. Runs the selected test or script depending on the operation mode.None

ABORT subsystem (1)

CommandWhat it doesArguments
ABORTAbort. Aborts the test or script immediately.None

STATUS subsystem (1)

CommandWhat it doesArguments
STATUSRead Status. Requests the instrument measurement status string.None

XRESULT subsystem (1)

CommandWhat it doesArguments
XRESULT <Test>,<Stage>Read Extended Results. Returns the extended results for a test stage (e.g. HOPONL, HOPOFFM; ERP uses e.g. HOPOFFLMAX).Text: OP,PC,EPC,MI,IC,CD,SS,MS,MP,ERP,ECM,EDP,EBS,EFS,EMP,LEOP,LEICD,LEMI,LESS,LEPRI,LEMP; Text: HOPONL,HOPONM,HOPONH,HOPONALL,HOPONANY,HOPOFFL,HOPOFFM,HOPOFFH

ESIGGEN subsystem (1)

CommandWhat it doesArguments
ESIGGEN <Parameters>Set EDR Signal Generator. Configures the EDR signal generator: PI4|8DPSK,DATAPRBS9|DATAPRBS15,CHAN|FREQ,channel,power,ON|OFF (e.g. PI4,DATAPRBS15,CHAN,7,-40.0,ON).Text

LEPKTGEN subsystem (1)

CommandWhat it doesArguments
LEPKTGEN <Parameters>Set BLE Packet Generator. Configures the BLE 5 packet generator (adds packet length and BLE|2LE|LR8|LR2 packet type; options 35/36).Text

CWMEAS subsystem (1)

CommandWhat it doesArguments
CWMEAS <Channel_Mode>,<Channel>,<Gate_Width>Set CW Measurement. Configures CW measurement mode: channel (-2 to 98) or frequency (Hz) and gate width (0.1 ms to 3 ms).Text: CHAN,FREQ; Number; Number

CWRESULT subsystem (1)

CommandWhat it doesArguments
CWRESULT <Type>Read CW Result. Reads the CW measurement result (frequency offset in Hz, power in dBm, or +/- modulation in Hz).Text: FREQOFF,POWER,MOD

ECWRESULT subsystem (1)

CommandWhat it doesArguments
ECWRESULT <Type>Read EDR CW Result. Reads the EDR CW measurement result.Text: PKPWR,RMSPWR,PKDEVM,RMSDEVM

CFGBLECAP subsystem (1)

CommandWhat it doesArguments
CFGBLECAP <Channel>,<Trigger>Configure BLE Capture. Configures capture of a BLE test packet on a BLE RF channel (0 to 39).Number: 0,39; Text: RF,EXT

SETBLECAPTYP subsystem (1)

CommandWhat it doesArguments
SETBLECAPTYP <Type>Set BLE Capture Type. Sets the low energy packet type to capture.Text: BLE,2LE,BLR

MEASBLECAP subsystem (1)

CommandWhat it doesArguments
MEASBLECAP <Measurement>,<Mod_Type>,<Syncword>Measure BLE Capture. Captures and makes a BLE Tx measurement (e.g. LEOP,NA,71764129).Text: LEOP,LEICD,LEICD2M,LEICDLR8,LEMI,LEMI2M; Text; Text

ABORTCAP subsystem (1)

CommandWhat it doesArguments
ABORTCAPAbort BLE Capture. Aborts the BLE measurement capture.None

CONNECT subsystem (1)

CommandWhat it doesArguments
CONNECTConnect. Connects to the EUT address (does not request EUT features).None

DISCONNECT subsystem (1)

CommandWhat it doesArguments
DISCONNECTDisconnect. Disconnects from the device.None

TESTMODE subsystem (1)

CommandWhat it doesArguments
TESTMODEEUT Test Mode. Puts the EUT into test mode.None

EUTRESET subsystem (1)

CommandWhat it doesArguments
EUTRESETEUT Reset. Sends an HCI Reset to the DUT.None

EUTRMTPWR subsystem (1)

CommandWhat it doesArguments
EUTRMTPWR <Step>EUT Remote Power. Changes the EUT Tx power state.Text: MIN,DEC,INC,MAX

EUTINIT subsystem (1)

CommandWhat it doesArguments
EUTINITEUT Peripheral Mode. Puts the MT8852B into Bluetooth Peripheral mode (*RST returns to Central mode).None

INQUIRY subsystem (1)

CommandWhat it doesArguments
INQUIRYInquiry. Performs an inquiry for Bluetooth devices.None

INQCANCEL subsystem (1)

CommandWhat it doesArguments
INQCANCELCancel Inquiry. Cancels an inquiry operation.None

INQRSP subsystem (1)

CommandWhat it doesArguments
INQRSP?Read Inquiry Response. Returns the addresses and names found by the inquiry.None

GETEUTFEAT subsystem (1)

CommandWhat it doesArguments
GETEUTFEATGet EUT Features. Obtains the supported features from the EUT.None

CONTIME subsystem (1)

CommandWhat it doesArguments
CONTIME?Read Connection Time. Returns the time taken to make the connection in ms (option 15).None

TSTDELAY subsystem (1)

CommandWhat it doesArguments
TSTDELAY <Script>,<Packets>Set Test Delay. Sets the test control delay in packets (0 to 100).Number: 1,2,3,4,5,6,7,8,9,10; Number: 0,100

WRDTY subsystem (1)

CommandWhat it doesArguments
WRDTY <Script>,<Test>Write Dirty Parameters. Writes the dirty parameter settings to the core.Number: 1,2,3,4,5,6,7,8,9,10; Text: SS,MS

PATHEDIT subsystem (1)

CommandWhat it doesArguments
PATHEDIT <Table>,CHAN,<Channel>,<Offset>Edit Path Loss Table. Adds or changes an entry (channel 0 to 78, offset 0.0 to -40.0 dB) in a path loss table.Number: 1,2,3,4,5; Number: 0,78; Number

PATHDEL subsystem (1)

CommandWhat it doesArguments
PATHDEL <Table>,CHAN,<Channel>Delete Path Loss Entry. Deletes an entry from a path loss table.Number: 1,2,3,4,5; Number: 0,78

PATHRD subsystem (1)

CommandWhat it doesArguments
PATHRD <Table>,CHANRead Path Loss Table. Reads a complete path loss table.Number: 1,2,3,4,5

PATHTBL subsystem (1)

CommandWhat it doesArguments
PATHTBL <Script>,<Table>Set Path Table. Selects the path offset table used by a script.Number: 1,2,3,4,5,6,7,8,9,10; Number: 1,2,3,4,5

PATHTBLCLR subsystem (1)

CommandWhat it doesArguments
PATHTBLCLR <Table>Clear Path Table. Clears a user path table.Number: 1,2,3,4,5

OPTSTATUS subsystem (1)

CommandWhat it doesArguments
OPTSTATUS?Read Options. Returns the enabled options.None

ERRLST subsystem (1)

CommandWhat it doesArguments
ERRLSTRead Error List. Reads and clears the recorded error states latch.None

BOOTSTATUS subsystem (1)

CommandWhat it doesArguments
BOOTSTATUS?Read Boot Status. Returns the startup self test status (0 passed, 1 running, -1 failed).None

STERR subsystem (1)

CommandWhat it doesArguments
STERRRead Self Test Errors. Returns the results of the most recent self test without running it.None

CONT subsystem (1)

CommandWhat it doesArguments
CONTContinue After Self Test. Continues the startup sequence after non-DSP self test failures.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (19)

CommandWhat it doesArguments
*ESE <Mask>Set Event Status Enable. Sets the Standard Event Status Enable register (8-bit decimal mask).Number: 0,255
*ESE?Read Event Status Enable. Reads the Standard Event Status Enable register.None
*ESR?Read Event Status Register. Reads and clears the Standard Event Status register.None
*SRE <Mask>Set Service Request Enable. Sets the Service Request Enable register (8-bit decimal mask).Number: 0,255
*STB?Read Status Byte. Reads the Status Byte register.None
*INE <Mask>Set Instrument Status Enable. Sets the Instrument Status Enable register.Number: 0,255
*INS?Read Instrument Status. Reads the Instrument Status register.None
*ETE <Mask>Set EUT Fail Enable. Sets the EUT Fail Enable register.Number: 0,255
*ETF?Read EUT Fail Register. Reads and clears the EUT Fail register.None
*EETF?Read EDR EUT Fail Register. Reads and clears the EDR EUT Fail register.None
*LEETF?Read BLE EUT Fail Register. Reads and clears the BLE EUT Fail register.None
*CHG?Read Change Register. Reads the Change register.None
*OPCOperation Complete Set. Sets the OPC bit in the ESR when all pending operations are complete.None
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial number, software revision).None
*RSTReset. Resets the MT8852B to its default state (same as the PRESET key).None
*CLSClear Status. Clears all GPIB status data structures except the MAV bit.None
*TST?Self Test. Runs a self test and returns ALL TESTS PASSED or SELFTEST FAILED.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Wait to continue (decoded but no action on the MT8852B).None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Anritsu's programming documentation for the MT8852B and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Anritsu's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Anritsu MT8852B support SCPI remote control?

Yes. The Anritsu MT8852B accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 193 SCPI commands for it: 70 queries that read values or state, and 123 settings and actions.

How do I control the Anritsu MT8852B from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, SYSCFG AUTH,STATE,ON and OPMD?.

Which command reads a value from the Anritsu MT8852B?

OPMD? (read operation mode). Reads the operation mode in the form of the set command. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Anritsu MT8852B without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Anritsu MT8852B through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.