Radio Test Set · SCPI command reference

Viavi ALT-8000 SCPI commands

The Viavi ALT-8000 radio test set is controlled remotely with SCPI commands. TestFlow's instrument library holds 45 commands for it, 13 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the ALT-8000 on a real bench.

Commands
45
Queries
13
Subsystems
8
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Viavi ALT-8000 and writes the report from the measured results.

Get started

Control the Viavi ALT-8000 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Viavi ALT-8000's VISA address

# Paste the address of your Viavi ALT-8000 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("RALTimeter:ASIMulation:MODE MANual")  # Set Simulation Mode
print(inst.query("RALTimeter:ASIMulation:MODE?"))  # Read Simulation Mode

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Viavi ALT-8000 and writes the report from the measured results.

Get started

Run a ALT-8000 test without writing code

Describe the test in a sentence, for example “set simulation mode on the ALT-8000, then read simulation mode and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

45 commands in 8 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

RALT subsystem (32)

CommandWhat it doesArguments
RALTimeter:ASIMulation:MODE <Mode>Set Simulation Mode. Selects manual (linear ramp) or profile (multi-leg) altitude simulation.Text: MANual,PROFile
RALTimeter:ASIMulation:MODE?Read Simulation Mode. Returns the altitude simulation mode.None
RALTimeter:ASIMulation:MANual:CHANnel<Ch>:ALTitude <Feet>Set Altitude. Sets the simulated altitude in feet (-20 to 5500); manual mode with test paused.Number: 1,2,3; Number: -20,5500
RALTimeter:ASIMulation:MANual:CHANnel<Ch>:ALTitude?Read Altitude. Returns the currently simulated altitude in feet.Number: 1,2,3
RALTimeter:ASIMulation:MANual:CHANnel<Ch>:RATE <Rate>Set Altitude Rate. Sets the simulated altitude rate in ft/min (0 to 120000; 0 = static altitude).Number: 1,2,3; Number: 0,120000
RALTimeter:ASIMulation:MANual:CHANnel<Ch>:STARt <Feet>Set Start Altitude. Sets the simulated start altitude in feet (-20 to 5500).Number: 1,2,3; Number: -20,5500
RALTimeter:ASIMulation:MANual:CHANnel<Ch>:STOP <Feet>Set Stop Altitude. Sets the simulated stop altitude in feet (-20 to 5500).Number: 1,2,3; Number: -20,5500
RALTimeter:ASIMulation:PROFile:LIST?Read Profile List. Returns the list of stored altitude profiles.None
RALTimeter:ASIMulation:PROFile:CHANnel<Ch>:STORe <Name>Store Profile. Stores the current altitude profile under a name (1 to 20 characters).Number: 1,2,3; Text
RALTimeter:TEST:STARtStart Test. Starts the simulation test.None
RALTimeter:TEST:STOPStop Test. Stops the simulation test.None
RALTimeter:TEST:PAUSePause Test. Pauses the test.None
RALTimeter:TEST:RESumeResume Test. Resumes the test.None
RALTimeter:TEST:RUNNing?Read Test Running. Returns 1 if the test is running, 0 if not.None
RALTimeter:MEASure:CHANnel<Ch>:DATA?Measure Channel Data. Returns frequency, power, sweep rate, FM deviation, PRF and related measurements with validity flags.Number: 1,2,3
RALTimeter:SETup:CONNection <Conn>Set Connection. Selects the RF connection type.Text: DIRect,FEEDer,COUPler
RALTimeter:SETup:UUT:TYPE <Type>Set UUT Type. Manually sets the UUT type.Text: FMCW,CDF,PULSe
RALTimeter:SETup:UUT:ADETect <Mode>Set UUT Detect Mode. Sets UUT type detection to automatic or manual.Text: AUTO,MANual
RALTimeter:SETup:AID:MODE <Mode>Set AID Mode. Selects fixed (ARINC) or variable AID.Text: FIXed,VARiable
RALTimeter:SETup:AID:VALue <Feet>Set AID Value. Sets the AID in feet (0 to 99; with fixed AID only 0, 20, 40, 57 or 80 is accepted).Number: 0,99
RALTimeter:SETup:LEVel:MODE <Mode>Set Level Mode. Sets the RF level mode.Text: AUTO,MANual
RALTimeter:SETup:CHANnel<Ch>:LEVel <dBm>Set RF Level. Sets the RF level in dBm when level mode is manual (-76 to 17).Number: 1,2,3; Number: -76,17
RALTimeter:SETup:LEVel:OFFSet <dB>Set Level Offset. Sets the altitude RF level offset in dB (-20 to 20 in 0.5 dB steps).Number: -20,20
RALTimeter:SETup:CHANnel<Ch>:OFFSet <Feet>Set Altitude Offset. Sets the altitude offset in feet (0 to 100 in 0.5 ft steps).Number: 1,2,3; Number: 0,100
RALTimeter:SETup:CHANnel<Ch>:LOSS:CABLe:RX <dB>Set Cable RX Loss. Sets the cable RX loss in dB (0.0 to 9.9).Number: 1,2,3; Number: 0,9.9
RALTimeter:SETup:CHANnel<Ch>:LOSS:CABLe:TX <dB>Set Cable TX Loss. Sets the cable TX loss in dB (0.0 to 9.9).Number: 1,2,3; Number: 0,9.9
RALTimeter:SETup:CHANnel<Ch>:LOSS:EXTernal:RX <dB>Set External RX Loss. Sets the external RX loss in dB (0.0 to 50.0).Number: 1,2,3; Number: 0,50
RALTimeter:SETup:CHANnel<Ch>:LOSS:EXTernal:TX <dB>Set External TX Loss. Sets the external TX loss in dB (0.0 to 20.0).Number: 1,2,3; Number: 0,20
RALTimeter:SETTings:CHANnel<Ch>:RECall <Name>Recall Settings. Recalls a named settings file.Number: 1,2,3; Text
RALTimeter:SETTings:CHANnel<Ch>:STORe <Name>Store Settings. Stores the current settings under a file name.Number: 1,2,3; Text
RALTimeter:SETTings:CHANnel<Ch>:DEFaultDefault Settings. Sets factory default settings.Number: 1,2,3
RALTimeter:STATus:CHANnel<Ch>:UNLock:OVERall?Read Unlock Status. Returns the overall hardware lock status (1 = unlocked, 0 = locked).Number: 1,2,3

Configure (CONFigure) (2)

CommandWhat it doesArguments
CONFigure:VERSions?Read Versions. Returns the software/firmware versions.None
CONFigure:TEMPeratures?Read Temperatures. Returns internal temperatures.None

System (SYSTem) (2)

CommandWhat it doesArguments
SYSTem:ERRor?Read System Error. Returns the oldest error message in the error queue.None
SYSTem:ERRor:COUNt?Read Error Count. Returns the number of error messages in the queue.None

OPT subsystem (1)

CommandWhat it doesArguments
OPTions:LIST?Read Options. Returns the list of installed options.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (5)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string.None
*RSTReset. Resets the instrument to the *RST default settings.None
*CLSClear Status. Clears all event registers and the error queue.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete before continuing.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Viavi's programming documentation for the ALT-8000 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Viavi's programming manual: check it before you rely on an edge case. Last updated September 27, 2026.

Frequently asked questions

Does the Viavi ALT-8000 support SCPI remote control?

Yes. The Viavi ALT-8000 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 45 SCPI commands for it: 13 queries that read values or state, and 32 settings and actions.

How do I control the Viavi ALT-8000 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, RALTimeter:ASIMulation:MODE MANual and RALTimeter:ASIMulation:MODE?.

Which command reads a value from the Viavi ALT-8000?

RALTimeter:ASIMulation:MODE? (read simulation mode). Returns the altitude simulation mode. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Viavi ALT-8000 without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Viavi ALT-8000 through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.