The Stanford Research Systems DS360 function generator is controlled remotely with SCPI commands. TestFlow's instrument library holds 25 commands for it, 4 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the DS360 on a real bench.
Commands
25
Queries
4
Subsystems
14
Models covered
1
Run this on your bench
Describe the test; TestFlow's agent uses this command set to drive your Stanford Research Systems DS360 and writes the report from the measured results.
Control the Stanford Research Systems DS360 from Python
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Stanford Research Systems DS360's VISA address
# Paste the address of your Stanford Research Systems DS360 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("FUNC 0") # Set Function
print(inst.query("FREQ?")) # Read Frequency
inst.close()
Run this on your bench
Describe the test; TestFlow's agent uses this command set to drive your Stanford Research Systems DS360 and writes the report from the measured results.
Describe the test in a sentence, for example “set function on the DS360, then read frequency and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
25 commands in 14 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
OUTE subsystem (2)
Command
What it does
Arguments
OUTE 1
Turn On Output. Enables the output.
None
OUTE 0
Turn Off Output. Disables the output.
None
Frequency (FREQuency) (2)
Command
What it does
Arguments
FREQ <Freq>
Set Frequency. Sets the output frequency in Hz.
Number
FREQ?
Read Frequency. Reads the output frequency.
None
AMPL subsystem (2)
Command
What it does
Arguments
AMPL <Amp>VP
Set Amplitude. Sets the output amplitude (append VP/VR/DB for units).
Number
AMPL?
Read Amplitude. Reads the output amplitude.
None
OUTM subsystem (2)
Command
What it does
Arguments
OUTM 1
Set Output Balanced. Selects balanced output.
None
OUTM 0
Set Output Unbalanced. Selects unbalanced output.
None
MENA subsystem (2)
Command
What it does
Arguments
MENA 1
Enable Sweep. Enables the sweep.
None
MENA 0
Disable Sweep. Disables the sweep.
None
Function (FUNCtion) (1)
Command
What it does
Arguments
FUNC <Shape>
Set Function. Sets the output function (0=Sine,1=2-tone,2=White noise,3=Pink noise,4=Arb).
Number: 0,1,2,3,4
OFFS subsystem (1)
Command
What it does
Arguments
OFFS <Volt>
Set Offset. Sets the DC offset voltage.
Number
TERM subsystem (1)
Command
What it does
Arguments
TERM <Z>
Set Output Amplitude Impedance. Sets the output impedance/termination.
Number
STFR subsystem (1)
Command
What it does
Arguments
STFR <Freq>
Set Sweep Start. Sets the sweep start frequency in Hz.
Number
SPFR subsystem (1)
Command
What it does
Arguments
SPFR <Freq>
Set Sweep Stop. Sets the sweep stop frequency in Hz.
Number
Other subsystem (1)
Command
What it does
Arguments
<Output Variable>=<Equation>
Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)
Number; Text
WAIT subsystem (1)
Command
What it does
Arguments
wait(<ms>)
Wait. Waits for number of milliseconds
Number
SAVE subsystem (1)
Command
What it does
Arguments
save2var <Variable_name>
Save2Variable. Saves last measurement to a variable
Text
IEEE 488.2 common commands (7)
Command
What it does
Arguments
*TRG
Trigger Now. Issues a trigger.
None
*IDN?
Identify. Returns the instrument identification string.
None
*RST
Reset. Resets the instrument to its default state.
None
*CLS
Clear Status. Clears the status registers.
None
*TST?
Self Test. Runs the self-test and returns 0 for pass.
None
*RCL <Slot>
Recall Setting. Recalls a stored setting.
Number
*SAV <Slot>
Save Setting. Stores the current setting.
Number
Where these commands come from
This reference is generated from TestFlow's instrument library, which is drafted from Stanford Research Systems's programming documentation for the DS360 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Stanford Research Systems's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Frequently asked questions
Does the Stanford Research Systems DS360 support SCPI remote control?
Yes. The Stanford Research Systems DS360 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 25 SCPI commands for it: 4 queries that read values or state, and 21 settings and actions.
How do I control the Stanford Research Systems DS360 from Python?
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, FUNC 0 and FREQ?.
Which command reads a value from the Stanford Research Systems DS360?
FREQ? (read frequency). Reads the output frequency. The full list of queries is in the command reference on this page, grouped by subsystem.