The Stanford Research Systems CG792 clock generator is controlled remotely with SCPI commands. TestFlow's instrument library holds 107 commands for it, 50 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the CG792 on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Stanford Research Systems CG792 and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Stanford Research Systems CG792's VISA address
# Paste the address of your Stanford Research Systems CG792 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("SOURce1:REL") # Set Relative Phase Zero
print(inst.query("MODulation:MODE?")) # Read Modulation Mode
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Stanford Research Systems CG792 and writes the report from the measured results.
Describe the test in a sentence, for example “set relative phase zero on the CG792, then read modulation mode and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
107 commands in 4 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:REFerence:LOCK? | Read Reference Lock. Reads whether the reference oscillator is locked (LOCKED or UNLOCKED). | None |
| SYSTem:REFerence:EXTernal:STATus? | Read External Reference Status. Reads the external 10 MHz reference input voltage in volts. | None |
| SYSTem:REFerence:INTernal:TYPe? | Read Internal Reference Type. Reads the installed internal reference type (e.g. TCXO, OCXO or Rubidium). | None |
| SYSTem:REFerence:TCXO:FCONtrol <Trim> | Set TCXO Trim. Sets the TCXO fractional frequency trim (-49999e-9 to 49999e-9; default 0.0). | Number |
| SYSTem:REFerence:TCXO:FCONtrol? | Read TCXO Trim. Reads the TCXO frequency trim. | None |
| SYSTem:REFerence:OCXO:FCONtrol <Trim> | Set OCXO Trim. Sets the OCXO fractional frequency trim (-0.4e-6 to +0.4e-6; requires the OCXO option). | Number |
| SYSTem:REFerence:OCXO:FCONtrol? | Read OCXO Trim. Reads the OCXO frequency trim. | None |
| SYSTem:REFerence:OCXO:AGC? | Read OCXO AGC. Reads the OCXO automatic gain control status (ON or OFF). | None |
| SYSTem:REFerence:OCXO:HEAT? | Read OCXO Heater. Reads whether the OCXO heater is active (ON or OFF). | None |
| SYSTem:REFerence:OCXO:VARac? | Read OCXO Varactor. Reads the OCXO varactor tuning voltage in volts. | None |
| SYSTem:REFerence:RB:FCONtrol <Trim> | Set Rb Trim. Sets the rubidium reference frequency trim (default 0.0; requires the rubidium option). | Number |
| SYSTem:REFerence:RB:FCONtrol? | Read Rb Trim. Reads the rubidium reference frequency trim. | None |
| SYSTem:REFerence:RB:STATus? | Read Rb Status. Reads the rubidium reference status code. | None |
| SYSTem:REFerence:RB:TEMP<Sensor>? | Read Rb Temperature. Reads a rubidium reference temperature sensor in degrees C. | Number |
| SYSTem:DISPlay:LEVel <Level> | Set Display Brightness. Sets the display brightness in percent (20 to 100; default 50). | Number |
| SYSTem:DISPlay:LEVel? | Read Display Brightness. Reads the display brightness in percent. | None |
| SYSTem:DISPlay:OFF ON | Turn On Display. Turns the display on (default). | None |
| SYSTem:DISPlay:OFF OFF | Turn Off Display. Turns the display off immediately. | None |
| SYSTem:DISPlay:OFF <Timer> | Set Display Auto Off. Sets the display auto-off timer (MIN=1 minute,1H,2H,4H,8H,DAY or WEEK). | Text: MIN,1H,2H,4H,8H,DAY,WEEK |
| SYSTem:DISPlay:OFF? | Read Display State. Reads the display state or auto-off setting. | None |
| SYSTem:COMMunicate:LAN:DHCP ON | Turn On DHCP. Enables DHCP on the LAN interface (default). | None |
| SYSTem:COMMunicate:LAN:DHCP OFF | Turn Off DHCP. Disables DHCP and uses static addressing. | None |
| SYSTem:COMMunicate:LAN:DHCP? | Read DHCP State. Reads the DHCP enable state (ON or OFF). | None |
| SYSTem:COMMunicate:LAN:DHCP:STATus? | Read DHCP Status. Reads the DHCP lease status description. | None |
| SYSTem:COMMunicate:LAN:IPADdress <IP> | Set IP Address. Sets the static IP address in dot notation (used when DHCP is disabled). | Text |
| SYSTem:COMMunicate:LAN:IPADdress? | Read IP Address. Reads the static IP address. | None |
| SYSTem:COMMunicate:LAN:MAC? | Read MAC Address. Reads the LAN MAC address. | None |
| SYSTem:COMMunicate:LAN:RESet | Reset LAN Interface. Resets the LAN interface to apply new network settings (connection drops temporarily). | None |
| SYSTem:COMMunicate:LAN:STATus? | Read LAN Status. Reads the LAN link status (Connected or Disconnected). | None |
| SYSTem:COMMunicate:SERial:BAUD <Baud> | Set Serial Baud Rate. Sets the RS-232 baud rate (default 9600). | Number: 9600,19200,38400,57600,115200 |
| SYSTem:COMMunicate:SERial:BAUD? | Read Serial Baud Rate. Reads the RS-232 baud rate. | None |
| SYSTem:COMMunicate:USB:BAUD? | Read USB Baud Rate. Reads the USB virtual COM port baud rate (always 115200). | None |
| SYSTem:LOCK 1 | Turn On Remote Lockout. Enables remote lockout mode. | None |
| SYSTem:LOCK 0 | Turn Off Remote Lockout. Disables remote lockout mode. | None |
| SYSTem:BEEP OFF | Turn Off Beep. Turns the beep sound off. | None |
| SYSTem:BEEP LOW | Set Beep Low. Sets the beep loudness to low (default). | None |
| SYSTem:BEEP HIGH | Set Beep High. Sets the beep loudness to high. | None |
| SYSTem:BEEP? | Read Beep. Reads the beep loudness setting. | None |
| SYSTem:ERRor? | Read Next Error. Reads and removes the next error from the error queue as code and message. | None |
| SYSTem:ERRor:CLEAR | Clear Error Queue. Clears all entries from the error queue. | None |
| SYSTem:INFO:MEMory? | Read Memory Usage. Reads the MPU and front-panel free memory in bytes. | None |
| SYSTem:INFO:TEMPerature? | Read Internal Temperature. Reads the MPU and front-panel processor temperatures in degrees C. | None |
| SYSTem:INFO:UPTime? | Read Uptime. Reads the time since the last reset or power-on in seconds. | None |
| SYSTem:INFO:VOLTage? | Read Supply Voltages. Reads the 15 internal power rail voltages as a comma-separated list. | None |
| SYSTem:REBoot | Reboot. Reboots the CG792 without saving the instrument settings. | None |
| SYSTem:FACToryreset | Factory Reset. Resets to the factory configuration and clears all stored settings including communication parameters. | None |
| Command | What it does | Arguments |
|---|---|---|
| SOURce<Ch>:FREQuency <Freq> | Set Frequency. Sets the output frequency of a channel in Hz (1e-3 to 2.2e9; default 10e6) (channels 3 and 4 require the optional rear-panel clock channels). | Number: 1,2,3,4; Number |
| SOURce<Ch>:FREQuency? | Read Frequency. Reads the output frequency of a channel in Hz. | Number: 1,2,3,4 |
| SOURce<Ch>:FASTfrequency <Freq> | Set Fast Frequency. Sets a channel frequency about 2x faster without parameter checking (do not change modulation or mode afterwards; reset and reboot to restore). | Number: 1,2,3,4; Number |
| SOURce<Ch>:PHASe <Phase> | Set Phase. Sets the phase offset of a channel in degrees (-720 to 720). | Number: 1,2,3,4; Number |
| SOURce<Ch>:PHASe? | Read Phase. Reads the phase offset of a channel in degrees (resolution-limited). | Number: 1,2,3,4 |
| SOURce<Ch>:EXTPhase? | Read Precise Phase. Reads the phase offset of a channel in degrees with 15 decimal places. | Number: 1,2,3,4 |
| SOURce<Ch>:REL | Set Relative Phase Zero. Defines the current phase of a channel as zero without changing the output. | Number: 1,2,3,4 |
| SOURce<Ch>:STATe ON | Turn On Output. Enables the clock output of a channel. | Number: 1,2,3,4 |
| SOURce<Ch>:STATe OFF | Turn Off Output. Disables the clock output of a channel and sets it to zero volts. | Number: 1,2,3,4 |
| SOURce<Ch>:STATe INV | Set Output Invert Mode. Enables a channel with its differential outputs inverted while the rear digital modulation input is asserted. | Number: 1,2,3,4 |
| SOURce<Ch>:STATe BLANK | Set Output Blank Mode. Enables a channel with its CMOS and differential outputs blanked while the rear digital modulation input is asserted. | Number: 1,2,3,4 |
| SOURce<Ch>:STATe PRBS | Set Output PRBS. Enables a channel outputting a pseudo-random bit sequence (PRBS31 up to 100 MHz). | Number: 1,2,3,4 |
| SOURce<Ch>:STATe LOW | Set Output Hold Low. Disables the clock of a channel and holds its output at the LOW level. | Number: 1,2,3,4 |
| SOURce<Ch>:STATe HIGH | Set Output Hold High. Disables the clock of a channel and holds its output at the HIGH level. | Number: 1,2,3,4 |
| SOURce<Ch>:STATe? | Read Output State. Reads the output state of a channel (OFF,ON,INV,BLANK,PRBS,LOW or HIGH). | Number: 1,2,3,4 |
| SOURce<Ch>:SYNC <RefCh> | Sync Phase. Synchronizes the phase of channel Ch to channel RefCh by frequency detuning (only certain channel pairs can be synced directly). | Number: 1,2,3,4; Number: 1,2,3,4 |
| SOURce<Ch>:VOLTage:AMPLitude <Volt> | Set Amplitude. Sets the differential output peak-to-peak amplitude of a channel in volts (0 to 1.2; default 1.0). | Number: 1,2,3,4; Number |
| SOURce<Ch>:VOLTage:AMPLitude? | Read Amplitude. Reads the differential output amplitude of a channel in volts. | Number: 1,2,3,4 |
| SOURce<Ch>:VOLTage:OFFSet <Volt> | Set Offset. Sets the differential output DC offset of a channel in volts (-3 to 2; default 0.0). | Number: 1,2,3,4; Number |
| SOURce<Ch>:VOLTage:OFFSet? | Read Offset. Reads the differential output DC offset of a channel in volts. | Number: 1,2,3,4 |
| SOURce<Ch>:INST? | Read Module Installed. Returns 1 if a source module is installed in channel position Ch or 0 otherwise. | Number: 1,2,3,4 |
| SOURce<Ch>:MODulation:DEViation <Dev> | Set Modulation Deviation. Sets the modulation deviation of a channel (FM: fraction of carrier 0 to 75e-6; PM: seconds per volt of external input). | Number: 1,2,3,4; Number |
| SOURce<Ch>:MODulation:DEViation? | Read Modulation Deviation. Reads the modulation deviation of a channel. | Number: 1,2,3,4 |
| SOURce<Ch>:MODulation:JITTer ON | Turn On Channel Jitter. Enables jitter modulation on a channel. | Number: 1,2,3,4 |
| SOURce<Ch>:MODulation:JITTer OFF | Turn Off Channel Jitter. Disables jitter modulation on a channel (default). | Number: 1,2,3,4 |
| SOURce<Ch>:MODulation:JITTer? | Read Channel Jitter State. Reads the jitter modulation state of a channel (ON or OFF). | Number: 1,2,3,4 |
| Command | What it does | Arguments |
|---|---|---|
| MODulation:MODE OFF | Turn Off Modulation. Disables modulation (default). | None |
| MODulation:MODE <Mode> | Set Modulation Mode. Sets the modulation mode (FM=frequency,PM=external phase,JITTER=jitter modulation). | Text: FM,PM,JITTER |
| MODulation:MODE? | Read Modulation Mode. Reads the modulation mode (OFF,FM,PM or JITTER). | None |
| MODulation:TYPE <Type> | Set Modulation Type. Sets the modulation waveform type. | Text: SINe,TRIangle,RAMP,SQUare,NOISe,EXTernal |
| MODulation:TYPE? | Read Modulation Type. Reads the modulation waveform type. | None |
| MODulation:PERiod <Time> | Set Modulation Period. Sets the modulation period in seconds (0.1e-3 to 5; default 1.0). | Number |
| MODulation:PERiod? | Read Modulation Period. Reads the modulation period in seconds. | None |
| MODulation:PERiod:ACTual? | Read Actual Modulation Period. Reads the effective modulation period in seconds after quantization. | None |
| MODulation:RATE <Rate> | Set Modulation Sample Rate. Sets the modulation sample rate in samples per second (range depends on the other modulation settings). | Number |
| MODulation:RATE? | Read Modulation Sample Rate. Reads the modulation sample rate in samples per second. | None |
| MODulation:JITTer <Time> | Set Jitter Magnitude. Sets the peak-to-peak jitter magnitude in seconds (0 to 3e-3; default 0). | Number |
| MODulation:JITTer? | Read Jitter Magnitude. Reads the peak-to-peak jitter magnitude in seconds. | None |
| MODulation:BLANk ON | Turn On Modulation Blanking. Enables modulation blanking (modulation zeroed while the rear digital input is asserted). | None |
| MODulation:BLANk OFF | Turn Off Modulation Blanking. Disables modulation blanking (default). | None |
| MODulation:BLANk? | Read Modulation Blanking. Reads the modulation blanking state (ON or OFF). | None |
| MODulation:POLarity 0 | Set Blank Polarity Low. Holds the clock LOW while blanking is asserted (default). | None |
| MODulation:POLarity 1 | Set Blank Polarity High. Holds the clock HIGH while blanking is asserted. | None |
| MODulation:POLarity? | Read Blank Polarity. Reads the blanking polarity (0=LOW or 1=HIGH). | None |
| MODulation:ZERO 1 | Pause Modulation. Immediately pauses the modulation output without altering the settings. | None |
| MODulation:ZERO 0 | Resume Modulation. Resumes a paused modulation output. | None |
| Command | What it does | Arguments |
|---|---|---|
| *SAV <Location> | Save Settings. Saves the instrument settings to location 1 to 7 (location 0 holds the current settings). | Number: 1,2,3,4,5,6,7 |
| *RCL <Location> | Recall Settings. Recalls the instrument settings from location 0 to 8 (0=startup settings,8=factory defaults). | Number: 0,1,2,3,4,5,6,7,8 |
| *ESE <Mask> | Set Standard Event Enable. Sets the standard event status enable register (0 to 255). | Number |
| *ESE? | Read Standard Event Enable. Reads the standard event status enable register. | None |
| *ESR? | Read Standard Event Register. Reads and clears the standard event status register. | None |
| *SRE <Mask> | Set Service Request Enable. Sets the service request enable register (0 to 255). | Number |
| *SRE? | Read Service Request Enable. Reads the service request enable register. | None |
| *STB? | Read Status Byte. Reads the status byte (bit 2=error queue not empty,5=ESB,6=MSS) without clearing it. | None |
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). | None |
| *RST | Reset. Restores factory default settings (equivalent to *RCL 8). | None |
| *CLS | Clear Status. Clears the event registers and the error queue. | None |
| *TST? | Self Test. Runs the start-up self-test and returns PASS or FAIL. | None |
| *OPC | Set Operation Complete. Sets the OPC bit in the standard event status register when all prior commands have completed. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *WAI | Wait To Continue. Waits until all prior commands have completed (commands already execute sequentially). | None |
This reference is generated from TestFlow's instrument library, which is drafted from Stanford Research Systems's programming documentation for the CG792 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Stanford Research Systems's programming manual: check it before you rely on an edge case. Last updated October 14, 2026.
Yes. The Stanford Research Systems CG792 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 107 SCPI commands for it: 50 queries that read values or state, and 57 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, SOURce1:REL and MODulation:MODE?.
MODulation:MODE? (read modulation mode). Reads the modulation mode (OFF,FM,PM or JITTER). The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Stanford Research Systems CG792 through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.