The Rohde & Schwarz SGT100A vector signal generator is controlled remotely with SCPI commands. TestFlow's instrument library holds 47 commands for it, 19 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the SGT100A on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Rohde & Schwarz SGT100A and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Rohde & Schwarz SGT100A's VISA address
# Paste the address of your Rohde & Schwarz SGT100A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("OUTPut:STATe ON") # Turn On RF Output
print(inst.query("OUTPut:STATe?")) # Read RF Output State
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Rohde & Schwarz SGT100A and writes the report from the measured results.
Describe the test in a sentence, for example “turn on rf output on the SGT100A, then read rf output state and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
47 commands in 7 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| SOURce:FREQuency:CW <Freq> | Set Frequency. Sets the frequency of the RF output signal in CW/fixed mode in Hz (1 MHz to 6 GHz depending on installed options). | Number |
| SOURce:FREQuency:CW? | Read Frequency. Reads the current CW/fixed RF output frequency in Hz. | None |
| SOURce:FREQuency:OFFSet <Freq> | Set Frequency Offset. Sets a frequency offset value added to the displayed/programmed RF frequency to account for external mixers etc. | Number |
| SOURce:FREQuency:OFFSet? | Read Frequency Offset. Reads the current RF frequency offset value in Hz. | None |
| SOURce:POWer:LEVel:IMMediate:AMPLitude <Power> | Set Power Level. Sets the RF output level (power) applied to the DUT, in dBm. | Number |
| SOURce:POWer:LEVel:IMMediate:AMPLitude? | Read Power Level. Reads the current RF output level in dBm. | None |
| SOURce:POWer:ALC:STATe ON | Turn On ALC. Activates the internal automatic level control (ALC) permanently. | None |
| SOURce:POWer:ALC:STATe OFF | Turn Off ALC. Deactivates the automatic level control; the instrument operates in Sample and Hold mode. | None |
| SOURce:POWer:ALC:STATe? | Read ALC State. Reads the current ALC (automatic level control) state. | None |
| SOURce:ROSCillator:SOURce <Source> | Set Reference Oscillator Source. Selects between the internal or an external reference oscillator frequency. | Text: INTernal,EXTernal |
| SOURce:ROSCillator:SOURce? | Read Reference Oscillator Source. Reads whether the internal or external reference oscillator is selected. | None |
| SOURce:ROSCillator:EXTernal:FREQuency <Freq> | Set External Reference Frequency. Selects the expected frequency of the external reference input signal (10 MHz, 5 MHz, 13 MHz, or a variable/user-defined value). | Text: 10MHZ,100MHZ,1000MHZ,13MHZ |
| SOURce:ROSCillator:EXTernal:FREQuency? | Read External Reference Frequency. Reads the configured external reference input frequency setting. | None |
| SOURce:PHASe <Phase> | Set Phase. Sets the phase variation of the RF output signal relative to the current phase, in degrees (-720 to 720). | Number: -720,720 |
| SOURce:PHASe? | Read Phase. Reads the current RF phase variation setting in degrees. | None |
| SOURce:BB:ARBitrary:STATe ON | Turn On ARB. Activates the ARB (arbitrary waveform) generator baseband signal. | None |
| SOURce:BB:ARBitrary:STATe OFF | Turn Off ARB. Deactivates the ARB (arbitrary waveform) generator baseband signal. | None |
| SOURce:BB:ARBitrary:STATe? | Read ARB State. Reads whether the ARB generator is currently ON or OFF. | None |
| SOURce:BB:ARBitrary:WAVeform:SELect <Name> | Load ARB Waveform. Selects/loads a waveform file from the default directory for the ARB generator (file extension can be omitted). | Text |
| SOURce:BB:ARBitrary:WAVeform:SELect? | Read ARB Waveform. Reads the name of the currently selected ARB waveform file. | None |
| SOURce:BB:ARBitrary:TRIGger:SOURce <Source> | Set ARB Trigger Source. Selects the trigger source that starts the ARB waveform (internal, external, other baseband, external baseband connector, or baseband synchronization). | Text: INTernal,EXTernal |
| SOURce:BB:ARBitrary:TRIGger:SOURce? | Read ARB Trigger Source. Reads the current ARB trigger source. | None |
| SOURce:BB:ARBitrary:TRIGger:EXECute | Execute ARB Trigger. Manually triggers ARB waveform generation for an internal trigger event. | None |
| SOURce:BB:ARBitrary:PRESet | Preset ARB. Resets all ARB generator parameters to their default state. | None |
| SOURce:IQ:STATe ON | Turn On IQ Modulation. Enables the I/Q modulation of the RF output signal. | None |
| SOURce:IQ:STATe OFF | Turn Off IQ Modulation. Disables the I/Q modulation of the RF output signal. | None |
| SOURce:IQ:STATe? | Read IQ Modulation State. Reads whether I/Q modulation is currently enabled. | None |
| Command | What it does | Arguments |
|---|---|---|
| OUTPut:STATe ON | Turn On RF Output. Activates the RF output signal. | None |
| OUTPut:STATe OFF | Turn Off RF Output. Deactivates the RF output signal. | None |
| OUTPut:STATe? | Read RF Output State. Reads whether the RF output is currently ON or OFF. | None |
| OUTPut:STATe:PON <Pon> | Set Power On Output State. Defines the state of the RF output signal when the instrument is switched on. | Text: OFF,UNCHanged |
| OUTPut:STATe:PON? | Read Power On Output State. Reads the configured RF output state used at power-on. | None |
| OUTPut:AMODe FIXed | Set Attenuator Mode Manual. Sets the RF output attenuator to manual mode so the attenuation value can be fixed. | None |
| OUTPut:AMODe AUTO | Set Attenuator Mode Auto. Sets the RF output attenuator to automatic mode (attenuation follows level setting). | None |
| OUTPut:AMODe? | Read Attenuator Mode. Reads the current RF output attenuator mode. | None |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:ERRor:ALL? | Read Error Queue. Queries and clears all unread entries from the error/event queue; returns 0,'No error' if the queue is empty. | None |
| SYSTem:ERRor:COUNt? | Read Error Count. Reads the number of entries currently in the error/event queue. | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). | None |
| *RST | Reset. Resets the instrument to its default state. | None |
| *CLS | Clear Status. Clears all event registers and the error queue. | None |
| *TST? | Self Test. Runs the self-test and returns 0 for pass or 1 for failure. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *WAI | Wait To Continue. Waits until all pending operations are complete before continuing. | None |
| *TRG | Trigger Bus. Generates a bus trigger when the instrument is in wait-for-trigger state. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Rohde & Schwarz's programming documentation for the SGT100A and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Rohde & Schwarz's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The Rohde & Schwarz SGT100A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 47 SCPI commands for it: 19 queries that read values or state, and 28 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut:STATe ON and OUTPut:STATe?.
OUTPut:STATe? (read rf output state). Reads whether the RF output is currently ON or OFF. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Rohde & Schwarz SGT100A through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.