Function Generator · SCPI command reference

Rohde & Schwarz HMF2550 SCPI commands

The Rohde & Schwarz HMF2550 function generator is controlled remotely with SCPI commands. TestFlow's instrument library holds 60 commands for it, 8 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the HMF2550 on a real bench.

Commands
60
Queries
8
Subsystems
9
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Rohde & Schwarz HMF2550 and writes the report from the measured results.

Get started

Control the Rohde & Schwarz HMF2550 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Rohde & Schwarz HMF2550's VISA address

# Paste the address of your Rohde & Schwarz HMF2550 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("OUTPut ON")  # Turn On Output
print(inst.query("OUTPut?"))  # Read Output State

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Rohde & Schwarz HMF2550 and writes the report from the measured results.

Get started

Run a HMF2550 test without writing code

Describe the test in a sentence, for example “turn on output on the HMF2550, then read output state and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

60 commands in 9 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Source (SOURce) (40)

CommandWhat it doesArguments
SOURce:FUNCtion <Shape>Set Function. Sets the output waveform shape.Text: SINusoid,SQUare,RAMP,PULSe,ARBitrary
SOURce:FUNCtion?Read Function. Reads the output waveform shape.None
SOURce:FREQuency <Freq>Set Frequency. Sets the output frequency in Hz.Number
SOURce:FREQuency?Read Frequency. Reads the output frequency.None
SOURce:VOLTage <Amp>Set Amplitude. Sets the output amplitude (Vpp).Number
SOURce:VOLTage?Read Amplitude. Reads the output amplitude.None
SOURce:VOLTage:OFFSet <Volt>Set Voltage Offset. Sets the DC offset voltage.Number
SOURce:VOLTage:OFFSet?Read Voltage Offset. Reads the DC offset voltage.None
SOURce:VOLTage:HIGH <Volt>Set Voltage High. Sets the high voltage level.Number
SOURce:VOLTage:LOW <Volt>Set Voltage Low. Sets the low voltage level.Number
SOURce:PHASe <Deg>Set Phase. Sets the output phase in degrees.Number
SOURce:FUNCtion:RAMP:SYMMetry <Pct>Set Ramp Symmetry. Sets the ramp symmetry percentage.Number
SOURce:FUNCtion:SQUare:DCYCle <Pct>Set Square Duty Cycle. Sets the square-wave duty cycle percentage.Number
SOURce:AM:STATe ONEnable AM. Enables AM modulation.None
SOURce:AM:STATe OFFDisable AM. Disables AM modulation.None
SOURce:AM:DEPTh <Pct>Set AM Depth. Sets the AM depth percentage.Number
SOURce:AM:INTernal:FREQuency <Freq>Set AM Int Freq. Sets the internal AM modulating frequency.Number
SOURce:FM:STATe ONEnable FM. Enables FM modulation.None
SOURce:FM:STATe OFFDisable FM. Disables FM modulation.None
SOURce:FM:DEViation <Freq>Set FM Deviation. Sets the FM frequency deviation.Number
SOURce:PM:STATe ONEnable PM. Enables PM modulation.None
SOURce:PM:STATe OFFDisable PM. Disables PM modulation.None
SOURce:PM:DEViation <Deg>Set PM Deviation. Sets the PM phase deviation.Number
SOURce:PWM:STATe ONEnable PWM. Enables PWM modulation.None
SOURce:PWM:STATe OFFDisable PWM. Disables PWM modulation.None
SOURce:FSKey:STATe ONEnable FSK. Enables FSK modulation.None
SOURce:FSKey:STATe OFFDisable FSK. Disables FSK modulation.None
SOURce:FSKey:FREQuency <Freq>Set FSK Hop Freq. Sets the FSK hop frequency.Number
SOURce:SWEep:STATe ONEnable Sweep. Enables the frequency sweep.None
SOURce:SWEep:STATe OFFDisable Sweep. Disables the frequency sweep.None
SOURce:SWEep:TIME <Sec>Set Sweep Time. Sets the sweep time in seconds.Number
SOURce:SWEep:SPACing <Type>Set Sweep Spacing. Sets the sweep spacing.Text: LINear,LOGarithmic
SOURce:FREQuency:STARt <Freq>Set Sweep Start Freq. Sets the sweep start frequency.Number
SOURce:FREQuency:STOP <Freq>Set Sweep Stop Freq. Sets the sweep stop frequency.Number
SOURce:BURSt:STATe ONEnable Burst. Enables burst mode.None
SOURce:BURSt:STATe OFFDisable Burst. Disables burst mode.None
SOURce:BURSt:MODE <Mode>Set Burst Mode. Sets the burst mode.Text: TRIGgered,GATed
SOURce:BURSt:NCYCles <N>Set Burst Cycles. Sets the number of cycles per burst.Number
SOURce:BURSt:INTernal:PERiod <Sec>Set Burst Period. Sets the internal burst period.Number
SOURce:BURSt:PHASe <Deg>Set Burst Phase. Sets the burst start phase.Number

Output (OUTPut) (7)

CommandWhat it doesArguments
OUTPut ONTurn On Output. Enables the output.None
OUTPut OFFTurn Off Output. Disables the output.None
OUTPut?Read Output State. Reads whether the output is on.None
OUTPut:LOAD TERMinatedSet Output Load 50. Sets the output load to 50 ohm.None
OUTPut:LOAD INFinitySet Output Load HighZ. Sets the output load to high-impedance.None
OUTPut:POLarity NORMalSet Output Polarity Normal. Sets output polarity to normal.None
OUTPut:POLarity INVertedSet Output Polarity Inverted. Sets output polarity to inverted.None

Function (FUNCtion) (2)

CommandWhat it doesArguments
FUNCtion:PULSe:DCYCle <Pct>Set Pulse Duty Cycle. Sets the pulse duty cycle percentage.Number
FUNCtion:PULSe:ETIMe <Sec>Set Pulse Edge Time. Sets the pulse edge (rise/fall) time.Number

Trigger (TRIGger) (2)

CommandWhat it doesArguments
TRIGger:SOURce <Src>Set Trigger Source. Sets the trigger source.Text: IMMediate,EXTernal
TRIGgerTrigger Now. Issues an immediate trigger.None

System (SYSTem) (1)

CommandWhat it doesArguments
SYSTem:ERRor?Read Error. Reads and clears the next error-queue entry.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (5)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Rohde & Schwarz's programming documentation for the HMF2550 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Rohde & Schwarz's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Rohde & Schwarz HMF2550 support SCPI remote control?

Yes. The Rohde & Schwarz HMF2550 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 60 SCPI commands for it: 8 queries that read values or state, and 52 settings and actions.

How do I control the Rohde & Schwarz HMF2550 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut ON and OUTPut?.

Which command reads a value from the Rohde & Schwarz HMF2550?

OUTPut? (read output state). Reads whether the output is on. The full list of queries is in the command reference on this page, grouped by subsystem.