The Rohde & Schwarz CMW290 radio test set is controlled remotely with SCPI commands. TestFlow's instrument library holds 316 commands for it, 162 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the CMW290 on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Rohde & Schwarz CMW290 and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Rohde & Schwarz CMW290's VISA address
# Paste the address of your Rohde & Schwarz CMW290 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("SOURce:GPRF:GENerator1:STATe ON") # Turn On Generator
print(inst.query("CONFigure:GPRF:MEASurement1:RFSettings:FREQuency?")) # Read Analyzer Frequency
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Rohde & Schwarz CMW290 and writes the report from the measured results.
Describe the test in a sentence, for example “turn on generator on the CMW290, then read analyzer frequency and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
316 commands in 16 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| CONFigure:GPRF:MEASurement1:RFSettings:FREQuency <Freq> | Set Analyzer Frequency. Sets the center frequency of the RF analyzer in Hz. | Number |
| CONFigure:GPRF:MEASurement1:RFSettings:FREQuency? | Read Analyzer Frequency. Reads the center frequency of the RF analyzer in Hz. | None |
| CONFigure:GPRF:MEASurement1:RFSettings:ENPower <Power> | Set Analyzer Expected Power. Sets the expected nominal power of the measured RF signal in dBm. | Number |
| CONFigure:GPRF:MEASurement1:RFSettings:ENPower? | Read Analyzer Expected Power. Reads the expected nominal power of the measured RF signal in dBm. | None |
| CONFigure:GPRF:MEASurement1:RFSettings:EATTenuation <Atten> | Set Analyzer External Attenuation. Sets the external attenuation (or gain, if negative) at the RF input connector in dB (-50 dB to 90 dB). | Number |
| CONFigure:GPRF:MEASurement1:RFSettings:EATTenuation? | Read Analyzer External Attenuation. Reads the external attenuation configured for the RF input path in dB. | None |
| CONFigure:GPRF:MEASurement1:RFSettings:UMARgin <Margin> | Set Analyzer User Margin. Sets the margin added to the expected nominal power to determine the reference power in dB. | Number |
| CONFigure:GPRF:MEASurement1:RFSettings:UMARgin? | Read Analyzer User Margin. Reads the user margin used to determine the reference power in dB. | None |
| CONFigure:GPRF:MEASurement1:RFSettings:MLOFfset <Offset> | Set Analyzer Mixer Level Offset. Varies the input level of the mixer in the analyzer path in dB (-10 dB to 16 dB). | Number |
| CONFigure:GPRF:MEASurement1:RFSettings:MLOFfset? | Read Analyzer Mixer Level Offset. Reads the mixer level offset of the analyzer path in dB. | None |
| CONFigure:GPRF:MEASurement1:RFSettings:FOFFset <Offset> | Set Analyzer Frequency Offset. Sets a positive or negative frequency offset added to the analyzer center frequency in Hz (-100 kHz to 100 kHz). | Number |
| CONFigure:GPRF:MEASurement1:RFSettings:FOFFset? | Read Analyzer Frequency Offset. Reads the analyzer frequency offset in Hz. | None |
| CONFigure:GPRF:MEASurement1:POWer:MODE <Mode> | Set Power Measurement Mode. Selects the power measurement mode used when list mode is off. | Text: POWer,STATistic |
| CONFigure:GPRF:MEASurement1:POWer:MODE? | Read Power Measurement Mode. Reads the selected power measurement mode. | None |
| CONFigure:GPRF:MEASurement1:POWer:REPetition <Repetition> | Set Power Repetition. Selects whether the power measurement is stopped after one cycle or repeated continuously. | Text: SINGleshot,CONTinuous |
| CONFigure:GPRF:MEASurement1:POWer:REPetition? | Read Power Repetition. Reads the repetition mode of the power measurement. | None |
| CONFigure:GPRF:MEASurement1:POWer:SCOunt <Count> | Set Power Statistic Count. Specifies the number of measurement intervals per measurement cycle (1 to 100000). | Number |
| CONFigure:GPRF:MEASurement1:POWer:SCOunt? | Read Power Statistic Count. Reads the statistic count of the power measurement. | None |
| CONFigure:GPRF:MEASurement1:POWer:MLENgth <Seconds> | Set Power Measurement Length. Sets the evaluation interval used to calculate one set of current power results (RMS, minimum, maximum) in seconds. | Number |
| CONFigure:GPRF:MEASurement1:POWer:MLENgth? | Read Power Measurement Length. Reads the power measurement evaluation interval in seconds. | None |
| CONFigure:GPRF:MEASurement1:POWer:SLENgth <Seconds> | Set Power Step Length. Sets the time between the beginnings of two consecutive measurement lengths in seconds. | Number |
| CONFigure:GPRF:MEASurement1:POWer:SLENgth? | Read Power Step Length. Reads the step length of the power measurement in seconds. | None |
| CONFigure:GPRF:MEASurement1:POWer:TOUT <Seconds> | Set Power Timeout. Defines a timeout for the power measurement in seconds; 0 s means an infinite timeout. | Number |
| CONFigure:GPRF:MEASurement1:POWer:TOUT? | Read Power Timeout. Reads the power measurement timeout in seconds. | None |
| CONFigure:GPRF:MEASurement1:POWer:PDEFset <Name> | Set Power Predefined Set. Loads a predefined parameter set for the power measurement. | Text |
| CONFigure:GPRF:MEASurement1:POWer:PDEFset? | Read Power Predefined Set. Reads the name of the loaded predefined power parameter set. | None |
| CONFigure:GPRF:MEASurement1:DISPlay <Tab> | Set Measurement Display Tab. Selects the measurement tab shown on the instrument display during remote control. | Text: POWer,SPECtrum,FFTSanalyzer,IQRecorder,IQVSlot,EPSensor |
| CONFigure:GPRF:MEASurement1:DISPlay? | Read Measurement Display Tab. Reads the measurement tab currently shown on the instrument display. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:FSPan <Span> | Set FFT Frequency Span. Configures the frequency span of the FFT spectrum analyzer in Hz. | Number: 1250000,2500000,5000000,10000000,20000000,40000000,80000000,160000000 |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:FSPan? | Read FFT Frequency Span. Reads the frequency span of the FFT spectrum analyzer in Hz. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:FFTLength <Length> | Set FFT Length. Selects the number of samples recorded per measurement interval of the FFT spectrum analyzer. | Number: 1024,2048,4096,8192,16384 |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:FFTLength? | Read FFT Length. Reads the configured FFT length. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:DETector <Detector> | Set FFT Detector. Defines how the spectrum diagram is calculated from the frequency domain samples. | Text: PEAK,RMS |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:DETector? | Read FFT Detector. Reads the detector used by the FFT spectrum analyzer. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:AMODe <Mode> | Set FFT Averaging Mode. Selects whether the average traces are calculated from linear or logarithmic power values. | Text: LINear,LOGarithmic |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:AMODe? | Read FFT Averaging Mode. Reads the averaging mode of the FFT spectrum analyzer. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:REPetition <Repetition> | Set FFT Repetition. Selects whether the FFT measurement is stopped after one cycle or repeated continuously. | Text: SINGleshot,CONTinuous |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:REPetition? | Read FFT Repetition. Reads the repetition mode of the FFT spectrum analyzer. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:SCOunt <Count> | Set FFT Statistic Count. Specifies the number of measurement intervals per single shot for the FFT measurement (1 to 1000). | Number |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:SCOunt? | Read FFT Statistic Count. Reads the statistic count of the FFT measurement. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:TOUT <Seconds> | Set FFT Timeout. Defines a timeout for the FFT measurement in seconds. | Number |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:TOUT? | Read FFT Timeout. Reads the FFT measurement timeout in seconds. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:MOEXception ON | Turn On FFT Measure On Exception. Accepts faulty FFT results instead of rejecting them. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:MOEXception OFF | Turn Off FFT Measure On Exception. Rejects faulty FFT results. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:MOEXception? | Read FFT Measure On Exception. Reads whether faulty FFT results are accepted or rejected. | None |
| CONFigure:GPRF:MEASurement1:SPECtrum:AMODe <Mode> | Set Spectrum Averaging Mode. Defines how the average traces are calculated from the current spectrum results. | Text: LINear,LOGarithmic |
| CONFigure:GPRF:MEASurement1:SPECtrum:AMODe? | Read Spectrum Averaging Mode. Reads the averaging mode of the spectrum measurement. | None |
| CONFigure:GPRF:MEASurement1:SPECtrum:REPetition <Repetition> | Set Spectrum Repetition. Selects whether the spectrum measurement is stopped after one cycle or repeated continuously. | Text: SINGleshot,CONTinuous |
| CONFigure:GPRF:MEASurement1:SPECtrum:REPetition? | Read Spectrum Repetition. Reads the repetition mode of the spectrum measurement. | None |
| CONFigure:GPRF:MEASurement1:SPECtrum:SCOunt <Count> | Set Spectrum Statistic Count. Specifies the number of measurement intervals per single shot for the spectrum measurement (1 to 1000). | Number |
| CONFigure:GPRF:MEASurement1:SPECtrum:SCOunt? | Read Spectrum Statistic Count. Reads the statistic count of the spectrum measurement. | None |
| CONFigure:GPRF:MEASurement1:SPECtrum:TOUT <Seconds> | Set Spectrum Timeout. Defines a timeout for the spectrum measurement in seconds; 0 s means an infinite timeout. | Number |
| CONFigure:GPRF:MEASurement1:SPECtrum:TOUT? | Read Spectrum Timeout. Reads the spectrum measurement timeout in seconds. | None |
| CONFigure:GPRF:MEASurement1:IQVSlot:SCOunt <Count> | Set IQVSlot Step Count. Defines the number of measurement steps per subsweep of the I/Q vs slot measurement (1 to 3000). | Number |
| CONFigure:GPRF:MEASurement1:IQVSlot:SCOunt? | Read IQVSlot Step Count. Reads the number of measurement steps of the I/Q vs slot measurement. | None |
| CONFigure:GPRF:MEASurement1:IQVSlot:MLENgth <Seconds> | Set IQVSlot Measurement Length. Sets the length of the evaluation intervals of the I/Q vs slot measurement in seconds. | Number |
| CONFigure:GPRF:MEASurement1:IQVSlot:MLENgth? | Read IQVSlot Measurement Length. Reads the evaluation interval length of the I/Q vs slot measurement in seconds. | None |
| CONFigure:GPRF:MEASurement1:IQVSlot:SLENgth <Seconds> | Set IQVSlot Step Length. Sets the time between the beginnings of two consecutive measurement steps in seconds. | Number |
| CONFigure:GPRF:MEASurement1:IQVSlot:SLENgth? | Read IQVSlot Step Length. Reads the step length of the I/Q vs slot measurement in seconds. | None |
| CONFigure:GPRF:MEASurement1:IQVSlot:FTYPe <Filter> | Set IQVSlot Filter Type. Selects the IF filter type used by the I/Q vs slot measurement. | Text: GAUSs,NYQuist,NY1Mhz |
| CONFigure:GPRF:MEASurement1:IQVSlot:FTYPe? | Read IQVSlot Filter Type. Reads the IF filter type of the I/Q vs slot measurement. | None |
| CONFigure:GPRF:MEASurement1:IQVSlot:FELimit <Limit> | Set IQVSlot Frequency Estimation Limit. Defines the frequency estimation limit as signal level relative to the nominal power in dB (-100 dB to 0 dB). | Number |
| CONFigure:GPRF:MEASurement1:IQVSlot:FELimit? | Read IQVSlot Frequency Estimation Limit. Reads the frequency estimation limit of the I/Q vs slot measurement in dB. | None |
| CONFigure:GPRF:MEASurement1:IQVSlot:REPetition <Repetition> | Set IQVSlot Repetition. Selects whether the I/Q vs slot measurement is stopped after one cycle or repeated continuously. | Text: SINGleshot,CONTinuous |
| CONFigure:GPRF:MEASurement1:IQVSlot:REPetition? | Read IQVSlot Repetition. Reads the repetition mode of the I/Q vs slot measurement. | None |
| CONFigure:GPRF:MEASurement1:IQVSlot:TOUT <Seconds> | Set IQVSlot Timeout. Defines a timeout for the I/Q vs slot measurement in seconds. | Number |
| CONFigure:GPRF:MEASurement1:IQVSlot:TOUT? | Read IQVSlot Timeout. Reads the I/Q vs slot measurement timeout in seconds. | None |
| CONFigure:GPRF:MEASurement1:EPSensor:FREQuency <Freq> | Set Power Sensor Frequency. Specifies the input frequency at the external power sensor in Hz for frequency correction. | Number |
| CONFigure:GPRF:MEASurement1:EPSensor:FREQuency? | Read Power Sensor Frequency. Reads the correction frequency of the external power sensor in Hz. | None |
| CONFigure:GPRF:MEASurement1:EPSensor:RESolution <Resolution> | Set Power Sensor Resolution. Defines the number of displayed digits of the external power sensor results. | Text: PD0,PD1,PD2,PD3 |
| CONFigure:GPRF:MEASurement1:EPSensor:RESolution? | Read Power Sensor Resolution. Reads the result resolution of the external power sensor measurement. | None |
| CONFigure:GPRF:MEASurement1:EPSensor:REPetition <Repetition> | Set Power Sensor Repetition. Selects whether the external power sensor measurement is stopped after one cycle or repeated continuously. | Text: SINGleshot,CONTinuous |
| CONFigure:GPRF:MEASurement1:EPSensor:REPetition? | Read Power Sensor Repetition. Reads the repetition mode of the external power sensor measurement. | None |
| CONFigure:GPRF:MEASurement1:EPSensor:SCOunt <Count> | Set Power Sensor Statistic Count. Specifies the statistic count of the external power sensor measurement (1 to 1000). | Number |
| CONFigure:GPRF:MEASurement1:EPSensor:SCOunt? | Read Power Sensor Statistic Count. Reads the statistic count of the external power sensor measurement. | None |
| CONFigure:GPRF:MEASurement1:EPSensor:TOUT <Seconds> | Set Power Sensor Timeout. Defines a timeout for the external power sensor measurement in seconds. | Number |
| CONFigure:GPRF:MEASurement1:EPSensor:TOUT? | Read Power Sensor Timeout. Reads the external power sensor measurement timeout in seconds. | None |
| CONFigure:LTE:SIGNaling1:PCC:BAND <Band> | Set LTE Operating Band. Selects the operating band of the LTE primary component carrier; the allowed range depends on the duplex mode. | Text: OB1,OB2,OB3,OB4,OB5,OB7,OB8,OB12,OB13,OB17,OB20,OB25,OB28,OB38,OB39,OB40,OB41,OB42 |
| CONFigure:LTE:SIGNaling1:PCC:BAND? | Read LTE Operating Band. Reads the selected LTE operating band of the primary component carrier. | None |
| CONFigure:LTE:SIGNaling1:PCC:DMODe <Mode> | Set LTE Duplex Mode. Selects the duplex mode of the LTE primary component carrier. | Text: FDD,TDD |
| CONFigure:LTE:SIGNaling1:PCC:DMODe? | Read LTE Duplex Mode. Reads the duplex mode of the LTE primary component carrier. | None |
| CONFigure:LTE:SIGNaling1:CELL:BANDwidth:PCC:DL <Bandwidth> | Set LTE Cell Bandwidth. Defines the DL cell bandwidth (1.4, 3, 5, 10, 15 or 20 MHz); the PCC DL bandwidth is also used for the UL. | Text: B014,B030,B050,B100,B150,B200 |
| CONFigure:LTE:SIGNaling1:CELL:BANDwidth:PCC:DL? | Read LTE Cell Bandwidth. Reads the configured LTE downlink cell bandwidth. | None |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:CHANnel:DL <Channel> | Set LTE Downlink Channel. Sets the downlink EARFCN of the primary component carrier; the uplink channel is calculated automatically. | Number |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:CHANnel:DL? | Read LTE Downlink Channel. Reads the downlink EARFCN of the primary component carrier. | None |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:CHANnel:UL <Channel> | Set LTE Uplink Channel. Sets the uplink EARFCN of the primary component carrier; the downlink channel is calculated automatically. | Number |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:CHANnel:UL? | Read LTE Uplink Channel. Reads the uplink EARFCN of the primary component carrier. | None |
| CONFigure:LTE:SIGNaling1:DL:PCC:RSEPre:LEVel <Level> | Set LTE RS EPRE Level. Defines the energy per resource element of the cell-specific reference signal in dBm/15 kHz. | Number |
| CONFigure:LTE:SIGNaling1:DL:PCC:RSEPre:LEVel? | Read LTE RS EPRE Level. Reads the RS EPRE downlink power level in dBm/15 kHz. | None |
| CONFigure:LTE:SIGNaling1:DL:PCC:AWGN <Level> | Set LTE AWGN Level. Specifies the level of the additive white Gaussian noise added to the downlink signal in dBm/15 kHz. | Number |
| CONFigure:LTE:SIGNaling1:DL:PCC:AWGN? | Read LTE AWGN Level. Reads the AWGN noise level of the downlink signal in dBm/15 kHz. | None |
| CONFigure:LTE:SIGNaling1:DL:PCC:OCNG ON | Turn On LTE OCNG. Enables the OFDMA channel noise generator on the downlink. | None |
| CONFigure:LTE:SIGNaling1:DL:PCC:OCNG OFF | Turn Off LTE OCNG. Disables the OFDMA channel noise generator on the downlink. | None |
| CONFigure:LTE:SIGNaling1:DL:PCC:OCNG? | Read LTE OCNG State. Reads whether the OFDMA channel noise generator is enabled. | None |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:ENPower <Power> | Set LTE Expected Nominal Power. Sets the expected nominal power of the uplink signal in dBm for manual nominal power mode. | Number |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:ENPower? | Read LTE Expected Nominal Power. Reads the expected nominal power of the uplink signal in dBm. | None |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:ENPMode <Mode> | Set LTE Nominal Power Mode. Selects whether the expected nominal power is set manually or derived from the uplink power control settings. | Text: MANual,ULPC |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:ENPMode? | Read LTE Nominal Power Mode. Reads the expected nominal power mode of the LTE signaling application. | None |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:UMARgin <Margin> | Set LTE User Margin. Sets the margin added to the expected nominal power to determine the reference level in dB. | Number |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:UMARgin? | Read LTE User Margin. Reads the user margin of the LTE signaling application in dB. | None |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:MLOFfset <Offset> | Set LTE Mixer Level Offset. Varies the input level of the mixer in the analyzer path in dB (-10 dB to 10 dB). | Number |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:MLOFfset? | Read LTE Mixer Level Offset. Reads the mixer level offset of the LTE signaling analyzer path in dB. | None |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:UDSeparation <Freq> | Set LTE UL DL Separation. Configures the uplink/downlink frequency separation in Hz; this setting is fixed for most operating bands. | Number |
| CONFigure:LTE:SIGNaling1:RFSettings:PCC:UDSeparation? | Read LTE UL DL Separation. Reads the configured uplink/downlink frequency separation in Hz. | None |
| CONFigure:LTE:SIGNaling1:CELL:CPRefix <Prefix> | Set LTE Cyclic Prefix. Defines whether a normal or an extended cyclic prefix is used. | Text: NORMal,EXTended |
| CONFigure:LTE:SIGNaling1:CELL:CPRefix? | Read LTE Cyclic Prefix. Reads the configured cyclic prefix type. | None |
| CONFigure:LTE:SIGNaling1:CELL:MCC <MCC> | Set LTE Mobile Country Code. Specifies the three-digit mobile country code of the simulated cell (0 to 999). | Number |
| CONFigure:LTE:SIGNaling1:CELL:MCC? | Read LTE Mobile Country Code. Reads the mobile country code of the simulated cell. | None |
| CONFigure:LTE:SIGNaling1:CELL:TAC <TAC> | Set LTE Tracking Area Code. Specifies the tracking area code of the simulated cell (0 to 65535). | Number |
| CONFigure:LTE:SIGNaling1:CELL:TAC? | Read LTE Tracking Area Code. Reads the tracking area code of the simulated cell. | None |
| CONFigure:LTE:SIGNaling1:CONNection:PCC:TRANsmission <Mode> | Set LTE Transmission Mode. Selects the LTE downlink transmission mode of the primary component carrier. | Text: TM1,TM2,TM3,TM4,TM6,TM7,TM8,TM9 |
| CONFigure:LTE:SIGNaling1:CONNection:PCC:TRANsmission? | Read LTE Transmission Mode. Reads the selected LTE downlink transmission mode. | None |
| CONFigure:LTE:SIGNaling1:CONNection:PCC:DCIFormat <Format> | Set LTE DCI Format. Selects the downlink control information format; the allowed values depend on the transmission mode. | Text: D1,D1A,D1B,D2,D2A,D2B,D2C,D61 |
| CONFigure:LTE:SIGNaling1:CONNection:PCC:DCIFormat? | Read LTE DCI Format. Reads the selected downlink control information format. | None |
| CONFigure:LTE:SIGNaling1:CONNection:PCC:NENBantennas <Antennas> | Set LTE Number Of eNB Antennas. Selects the number of downlink transmit antennas for transmission modes 1 to 6. | Text: ONE,TWO |
| CONFigure:LTE:SIGNaling1:CONNection:PCC:NENBantennas? | Read LTE Number Of eNB Antennas. Reads the number of configured downlink transmit antennas. | None |
| CONFigure:LTE:SIGNaling1:CONNection:PCC:HDUPlex ON | Turn On LTE Half Duplex. Selects half-duplex operation for the primary component carrier. | None |
| CONFigure:LTE:SIGNaling1:CONNection:PCC:HDUPlex OFF | Turn Off LTE Half Duplex. Selects full-duplex operation for the primary component carrier. | None |
| CONFigure:LTE:SIGNaling1:CONNection:PCC:HDUPlex? | Read LTE Half Duplex State. Reads whether half-duplex operation is enabled. | None |
| CONFigure:LTE:SIGNaling1:CONNection:PCC:TTIBundling ON | Turn On LTE TTI Bundling. Enables TTI bundling for the uplink. | None |
| CONFigure:LTE:SIGNaling1:CONNection:PCC:TTIBundling OFF | Turn Off LTE TTI Bundling. Disables TTI bundling for the uplink. | None |
| CONFigure:LTE:SIGNaling1:CONNection:PCC:TTIBundling? | Read LTE TTI Bundling State. Reads whether TTI bundling is enabled for the uplink. | None |
| CONFigure:LTE:MEASurement1:RFSettings:EATTenuation <Atten> | Set LTE Meas External Attenuation. Sets the external attenuation (or gain, if negative) at the LTE measurement input connector in dB (-50 dB to 90 dB). | Number |
| CONFigure:LTE:MEASurement1:RFSettings:EATTenuation? | Read LTE Meas External Attenuation. Reads the external attenuation of the LTE measurement input path in dB. | None |
| CONFigure:LTE:MEASurement1:RFSettings:ENPower <Power> | Set LTE Meas Expected Power. Sets the expected nominal power of the measured LTE uplink signal in dBm. | Number |
| CONFigure:LTE:MEASurement1:RFSettings:ENPower? | Read LTE Meas Expected Power. Reads the expected nominal power of the measured LTE uplink signal in dBm. | None |
| CONFigure:LTE:MEASurement1:RFSettings:UMARgin <Margin> | Set LTE Meas User Margin. Sets the margin added to the expected nominal power to determine the reference power in dB. | Number |
| CONFigure:LTE:MEASurement1:RFSettings:UMARgin? | Read LTE Meas User Margin. Reads the user margin of the LTE measurement in dB. | None |
| CONFigure:LTE:MEASurement1:RFSettings:FOFFset <Offset> | Set LTE Meas Frequency Offset. Specifies a frequency offset added to the carrier center frequency in Hz (-100 kHz to 100 kHz). | Number |
| CONFigure:LTE:MEASurement1:RFSettings:FOFFset? | Read LTE Meas Frequency Offset. Reads the frequency offset of the LTE measurement in Hz. | None |
| CONFigure:LTE:MEASurement1:RFSettings:MLOFfset <Offset> | Set LTE Meas Mixer Level Offset. Varies the input level of the mixer in the LTE analyzer path in dB (-10 dB to 10 dB). | Number |
| CONFigure:LTE:MEASurement1:RFSettings:MLOFfset? | Read LTE Meas Mixer Level Offset. Reads the mixer level offset of the LTE analyzer path in dB. | None |
| CONFigure:LTE:MEASurement1:MEValuation:MMODe <Mode> | Set LTE Meas Mode. Selects the LTE multi-evaluation measurement mode: normal, TPC, or multi-evaluation list mode. | Text: NORMal,TMODe,MELMode |
| CONFigure:LTE:MEASurement1:MEValuation:MMODe? | Read LTE Meas Mode. Reads the LTE multi-evaluation measurement mode. | None |
| CONFigure:LTE:MEASurement1:MEValuation:REPetition <Repetition> | Set LTE Meas Repetition. Selects whether the LTE multi-evaluation measurement is stopped after one cycle or repeated continuously. | Text: SINGleshot,CONTinuous |
| CONFigure:LTE:MEASurement1:MEValuation:REPetition? | Read LTE Meas Repetition. Reads the repetition mode of the LTE multi-evaluation measurement. | None |
| CONFigure:LTE:MEASurement1:MEValuation:TOUT <Seconds> | Set LTE Meas Timeout. Defines a timeout for the LTE multi-evaluation measurement in seconds. | Number |
| CONFigure:LTE:MEASurement1:MEValuation:TOUT? | Read LTE Meas Timeout. Reads the LTE multi-evaluation measurement timeout in seconds. | None |
| CONFigure:LTE:MEASurement1:MEValuation:SCONdition <Condition> | Set LTE Meas Stop Condition. Qualifies whether the LTE measurement is stopped after a limit failure or continues regardless. | Text: NONE,SLFail |
| CONFigure:LTE:MEASurement1:MEValuation:SCONdition? | Read LTE Meas Stop Condition. Reads the stop condition of the LTE multi-evaluation measurement. | None |
| CONFigure:LTE:MEASurement1:MEValuation:CPRefix <Prefix> | Set LTE Meas Cyclic Prefix. Selects the cyclic prefix type of the measured LTE uplink signal. | Text: NORMal,EXTended |
| CONFigure:LTE:MEASurement1:MEValuation:CPRefix? | Read LTE Meas Cyclic Prefix. Reads the cyclic prefix type used by the LTE measurement. | None |
| CONFigure:LTE:MEASurement1:MEValuation:CTYPe <Type> | Set LTE Meas Channel Type. Configures the uplink channel type detection of the LTE multi-evaluation measurement. | Text: AUTO,PUSCh,PUCCh |
| CONFigure:LTE:MEASurement1:MEValuation:CTYPe? | Read LTE Meas Channel Type. Reads the configured uplink channel type of the LTE measurement. | None |
| CONFigure:LTE:MEASurement1:MEValuation:PFORmat <Format> | Set LTE Meas PUCCH Format. Specifies the PUCCH format of the measured uplink signal according to 3GPP TS 36.211. | Text: F1,F1A,F1B,F2,F2A,F2B,F3 |
| CONFigure:LTE:MEASurement1:MEValuation:PFORmat? | Read LTE Meas PUCCH Format. Reads the configured PUCCH format of the LTE measurement. | None |
| CONFigure:LTE:MEASurement1:MEValuation:MSLot <Slot> | Set LTE Meas Slot. Selects which slots of a subframe are measured by the LTE multi-evaluation measurement. | Text: MS0,MS1,ALL |
| CONFigure:LTE:MEASurement1:MEValuation:MSLot? | Read LTE Meas Slot. Reads the slots measured by the LTE multi-evaluation measurement. | None |
| CONFigure:LTE:MEASurement1:MEValuation:SCOunt:MODulation <Count> | Set LTE Meas Modulation Statistic Count. Specifies the statistic count of the modulation measurement in slots (1 to 1000). | Number |
| CONFigure:LTE:MEASurement1:MEValuation:SCOunt:MODulation? | Read LTE Meas Modulation Statistic Count. Reads the statistic count of the LTE modulation measurement. | None |
| CONFigure:LTE:MEASurement1:MEValuation:SCOunt:POWer <Count> | Set LTE Meas Power Statistic Count. Specifies the statistic count of the power measurement in subframes (1 to 1000). | Number |
| CONFigure:LTE:MEASurement1:MEValuation:SCOunt:POWer? | Read LTE Meas Power Statistic Count. Reads the statistic count of the LTE power measurement. | None |
| CONFigure:LTE:MEASurement1:MEValuation:MOEXception ON | Turn On LTE Meas On Exception. Accepts faulty LTE measurement results instead of rejecting them. | None |
| CONFigure:LTE:MEASurement1:MEValuation:MOEXception OFF | Turn Off LTE Meas On Exception. Rejects faulty LTE measurement results. | None |
| CONFigure:LTE:MEASurement1:MEValuation:MOEXception? | Read LTE Meas On Exception. Reads whether faulty LTE measurement results are accepted or rejected. | None |
| CONFigure:BASE:FDCorrection:CTABle:CREate <Table_Name>, <Freq_Loss_Pairs> | Create Correction Table. Creates a frequency-dependent attenuation table; pairs are <Frequency Hz>, <Correction dB> (e.g. 1E9, 0.5, 2E9, 0.7). | Text; Text |
| CONFigure:BASE:FDCorrection:CTABle:DELete <Table_Name> | Delete Correction Table. Deletes the named correction table. | Text |
| CONFigure:BASE:FDCorrection:CTABle:CATalog? | Read Correction Table Catalog. Returns the names of all existing correction tables. | None |
| CONFigure:FDCorrection:ACTivate <Connector>, <Table_Name>, <Direction> | Activate Correction Table. Activates a correction table for an RF connector in direction RXTX, RX or TX. | Text: RF1C,RF1O,RF2C,RF3C,RF3O,RF4C; Text; Text: RXTX,RX,TX |
| CONFigure:FDCorrection:DEACtivate <Connector> | Deactivate Correction Table. Deactivates all correction tables of an RF connector. | Text: RF1C,RF1O,RF2C,RF3C,RF3O,RF4C |
| CONFigure:FDCorrection:DEACtivate:ALL | Deactivate All Correction Tables. Deactivates all correction tables of all RF connectors. | None |
| Command | What it does | Arguments |
|---|---|---|
| SOURce:GPRF:GENerator1:STATe ON | Turn On Generator. Turns the GPRF RF generator on. | None |
| SOURce:GPRF:GENerator1:STATe OFF | Turn Off Generator. Turns the GPRF RF generator off. | None |
| SOURce:GPRF:GENerator1:STATe? | Read Generator State. Reads the generator state (OFF / PENDing / ON / RDY). | None |
| SOURce:GPRF:GENerator1:STATe:ALL? | Read Generator State All. Reads detailed generator state information including the main state and the synchronization state. | None |
| SOURce:GPRF:GENerator1:BBMode <Mode> | Set Generator Baseband Mode. Selects the baseband mode of the generator signal: unmodulated CW, dual tone, or ARB waveform playback. | Text: CW,DTONe,ARB |
| SOURce:GPRF:GENerator1:BBMode? | Read Generator Baseband Mode. Reads the currently selected generator baseband mode. | None |
| SOURce:GPRF:GENerator1:RFSettings:FREQuency <Freq> | Set Generator Frequency. Sets the frequency of the unmodulated RF carrier in Hz (70 MHz to 6 GHz depending on installed options). | Number |
| SOURce:GPRF:GENerator1:RFSettings:FREQuency? | Read Generator Frequency. Reads the RF generator carrier frequency in Hz. | None |
| SOURce:GPRF:GENerator1:RFSettings:LEVel <Level> | Set Generator Level. Sets the base RMS level of the RF generator in dBm. | Number |
| SOURce:GPRF:GENerator1:RFSettings:LEVel? | Read Generator Level. Reads the base RMS output level of the RF generator in dBm. | None |
| SOURce:GPRF:GENerator1:RFSettings:EATTenuation <Atten> | Set Generator External Attenuation. Sets the external attenuation (or gain, if negative) at the RF output connector in dB (-50 dB to 90 dB). | Number |
| SOURce:GPRF:GENerator1:RFSettings:EATTenuation? | Read Generator External Attenuation. Reads the external attenuation configured for the RF output path in dB. | None |
| SOURce:GPRF:GENerator1:RFSettings:DGAin <Gain> | Set Generator Digital Gain. Sets the digital gain of the RF generator in dB. | Number |
| SOURce:GPRF:GENerator1:RFSettings:DGAin? | Read Generator Digital Gain. Reads the digital gain of the RF generator in dB. | None |
| SOURce:GPRF:GENerator1:RFSettings:PEPower? | Read Generator Peak Envelope Power. Reads the peak envelope power of the generated signal in dBm. | None |
| SOURce:GPRF:GENerator1:ARB:FILE <Filename> | Select ARB Waveform File. Selects the ARB waveform file (.wv) to be played back in ARB baseband mode. | Text |
| SOURce:GPRF:GENerator1:ARB:FILE? | Read ARB Waveform File. Reads the name of the currently loaded ARB waveform file. | None |
| SOURce:GPRF:GENerator1:ARB:FILE:DATE? | Read ARB File Date. Reads the creation date stored in the loaded ARB waveform file. | None |
| SOURce:GPRF:GENerator1:ARB:FILE:VERSion? | Read ARB File Version. Reads the version of the loaded ARB waveform file. | None |
| SOURce:GPRF:GENerator1:ARB:FILE:OPTion? | Read ARB File Options. Reads the list of instrument options required to play back the loaded ARB waveform file. | None |
| SOURce:GPRF:GENerator1:ARB:REPetition <Repetition> | Set ARB Repetition. Defines whether the ARB waveform file is processed continuously or for a defined number of cycles. | Text: CONTinuous,SINGle |
| SOURce:GPRF:GENerator1:ARB:REPetition? | Read ARB Repetition. Reads the ARB repetition mode. | None |
| SOURce:GPRF:GENerator1:ARB:CYCLes <Cycles> | Set ARB Cycles. Defines how often the ARB file is processed in single-shot repetition mode (1 to 10000). | Number |
| SOURce:GPRF:GENerator1:ARB:CYCLes? | Read ARB Cycles. Reads the configured number of ARB playback cycles. | None |
| SOURce:GPRF:GENerator1:ARB:FOFFset <Freq> | Set ARB Frequency Offset. Sets the frequency offset imposed at the baseband during ARB generation in Hz. | Number |
| SOURce:GPRF:GENerator1:ARB:FOFFset? | Read ARB Frequency Offset. Reads the ARB baseband frequency offset in Hz. | None |
| SOURce:GPRF:GENerator1:ARB:ASAMples <Samples> | Set ARB Additional Samples. Extends the processing time of the waveform file by the specified number of samples. | Number |
| SOURce:GPRF:GENerator1:ARB:ASAMples? | Read ARB Additional Samples. Reads the number of additional samples appended to the waveform file. | None |
| SOURce:GPRF:GENerator1:ARB:CRATe? | Read ARB Clock Rate. Reads the clock rate of the loaded ARB waveform file in Hz. | None |
| SOURce:GPRF:GENerator1:ARB:POFFset? | Read ARB Peak Offset. Reads the peak offset of the loaded ARB waveform file in dB. | None |
| SOURce:GPRF:GENerator1:ARB:LOFFset? | Read ARB Level Offset. Reads the level offset (peak to average ratio) of the loaded ARB waveform file in dB. | None |
| SOURce:GPRF:GENerator1:ARB:CRCProtect? | Read ARB CRC Protection. Reads whether the loaded ARB waveform file contains a CRC checksum. | None |
| SOURce:GPRF:GENerator1:ARB:STATus? | Read ARB Segment Status. Reads the number of the ARB segment currently being processed. | None |
| SOURce:GPRF:GENerator1:ARB:SCOunt? | Read ARB Sample Count. Reads the progress of the ARB file processing as elapsed time and sample count. | None |
| SOURce:GPRF:GENerator1:LIST ON | Turn On List Mode. Enables the frequency/level list mode of the RF generator. | None |
| SOURce:GPRF:GENerator1:LIST OFF | Turn Off List Mode. Disables the frequency/level list mode of the RF generator. | None |
| SOURce:GPRF:GENerator1:LIST? | Read List Mode State. Reads whether the generator list mode is enabled. | None |
| SOURce:GPRF:GENerator1:LIST:STARt <Index> | Set List Start Index. Defines the index of the first frequency/level step processed in list mode (0 to 1999). | Number |
| SOURce:GPRF:GENerator1:LIST:STARt? | Read List Start Index. Reads the index of the first frequency/level step in list mode. | None |
| SOURce:GPRF:GENerator1:LIST:STOP <Index> | Set List Stop Index. Defines the index of the last frequency/level step processed in list mode (0 to 1999). | Number |
| SOURce:GPRF:GENerator1:LIST:STOP? | Read List Stop Index. Reads the index of the last frequency/level step in list mode. | None |
| SOURce:GPRF:GENerator1:LIST:GOTO <Index> | Set List Goto Index. Defines the start index used for the subsequent list cycles in continuous repetition mode (1 to 2000). | Number |
| SOURce:GPRF:GENerator1:LIST:REPetition <Repetition> | Set List Repetition. Defines how often the RF generator runs through the frequency/level list. | Text: CONTinuous,SINGle |
| SOURce:GPRF:GENerator1:LIST:REPetition? | Read List Repetition. Reads the list mode repetition setting. | None |
| SOURce:GPRF:GENerator1:LIST:AINDex? | Read List Active Index. Reads the list index currently being generated (0 to 19). | None |
| SOURce:GPRF:GENerator1:LIST:COUNt? | Read List Step Count. Reads the number of frequency/level steps configured in list mode (1 to 2000). | None |
| SOURce:LTE:SIGNaling1:CELL:STATe ON | Turn On LTE Cell. Turns on the LTE signaling cell and activates the downlink signal. | None |
| SOURce:LTE:SIGNaling1:CELL:STATe OFF | Turn Off LTE Cell. Turns off the LTE signaling cell. | None |
| SOURce:LTE:SIGNaling1:CELL:STATe? | Read LTE Cell State. Reads whether the LTE signaling cell is switched on or off. | None |
| SOURce:LTE:SIGNaling1:CELL:STATe:ALL? | Read LTE Cell State All. Reads the detailed LTE cell state including the main state and the synchronization state. | None |
| Command | What it does | Arguments |
|---|---|---|
| FETCh:GPRF:MEASurement1:POWer:STATe? | Read Power Measurement State. Reads the main state of the power measurement (OFF / RUN / RDY). | None |
| FETCh:GPRF:MEASurement1:POWer:STATe:ALL? | Read Power Measurement State All. Reads the detailed power measurement state including the main state and the synchronization state. | None |
| FETCh:GPRF:MEASurement1:POWer:CURRent? | Fetch Power Current. Fetches the current power results of all measured segments in dBm without restarting the measurement. | None |
| FETCh:GPRF:MEASurement1:POWer:CURRent:RMS? | Fetch Power Current RMS. Fetches the current RMS power results in dBm. | None |
| FETCh:GPRF:MEASurement1:POWer:AVERage? | Fetch Power Average. Fetches the average power results of all measured segments in dBm. | None |
| FETCh:GPRF:MEASurement1:POWer:AVERage:RMS? | Fetch Power Average RMS. Fetches the average RMS power results in dBm. | None |
| FETCh:GPRF:MEASurement1:POWer:MAXimum:CURRent? | Fetch Power Maximum. Fetches the current-maximum power results (one value per measured segment) in dBm. | None |
| FETCh:GPRF:MEASurement1:POWer:MINimum:CURRent? | Fetch Power Minimum. Fetches the current-minimum power results (one value per measured segment) in dBm. | None |
| FETCh:GPRF:MEASurement1:POWer:PEAK:MAXimum? | Fetch Power Peak Maximum. Fetches the peak maximum power results in dBm. | None |
| FETCh:GPRF:MEASurement1:POWer:PEAK:MINimum? | Fetch Power Peak Minimum. Fetches the peak minimum power results in dBm. | None |
| FETCh:GPRF:MEASurement1:POWer:SDEViation? | Fetch Power Standard Deviation. Fetches the standard deviation of the power results in dB. | None |
| FETCh:GPRF:MEASurement1:FFTSanalyzer:STATe? | Read FFT Measurement State. Reads the main state of the FFT spectrum analyzer measurement. | None |
| FETCh:GPRF:MEASurement1:FFTSanalyzer:POWer:CURRent? | Fetch FFT Power Current. Fetches the current FFT spectrum trace as a list of 801 power values in dBm. | None |
| FETCh:GPRF:MEASurement1:FFTSanalyzer:POWer:AVERage? | Fetch FFT Power Average. Fetches the average FFT spectrum trace as a list of 801 power values in dBm. | None |
| FETCh:GPRF:MEASurement1:FFTSanalyzer:POWer:MAXimum? | Fetch FFT Power Maximum. Fetches the maximum-hold FFT spectrum trace in dBm. | None |
| FETCh:GPRF:MEASurement1:FFTSanalyzer:POWer:MINimum? | Fetch FFT Power Minimum. Fetches the minimum-hold FFT spectrum trace in dBm. | None |
| FETCh:GPRF:MEASurement1:SPECtrum:STATe? | Read Spectrum Measurement State. Reads the main state of the spectrum measurement. | None |
| FETCh:GPRF:MEASurement1:SPECtrum:RMS:CURRent? | Fetch Spectrum RMS Current. Fetches the current RMS spectrum trace in dBm. | None |
| FETCh:GPRF:MEASurement1:SPECtrum:RMS:AVERage? | Fetch Spectrum RMS Average. Fetches the average RMS spectrum trace in dBm. | None |
| FETCh:GPRF:MEASurement1:SPECtrum:RMS:MAXimum? | Fetch Spectrum RMS Maximum. Fetches the maximum-hold RMS spectrum trace in dBm. | None |
| FETCh:GPRF:MEASurement1:SPECtrum:RMS:MINimum? | Fetch Spectrum RMS Minimum. Fetches the minimum-hold RMS spectrum trace in dBm. | None |
| FETCh:GPRF:MEASurement1:IQVSlot:STATe? | Read IQVSlot Measurement State. Reads the main state of the I/Q vs slot measurement. | None |
| FETCh:GPRF:MEASurement1:EPSensor? | Fetch Power Sensor Results. Fetches the external power sensor results: current, average, minimum and maximum power in dBm. | None |
| FETCh:GPRF:MEASurement1:EPSensor:IDN? | Read Power Sensor Identification. Reads the identification string of the connected external power sensor. | None |
| FETCh:GPRF:MEASurement1:EPSensor:STATe? | Read Power Sensor State. Reads the main state of the external power sensor measurement. | None |
| FETCh:LTE:SIGNaling1:PSWitched:STATe? | Read LTE Connection State. Reads the packet-switched domain state (OFF / ON / ATTached / CESTablished / CONNecting and others). | None |
| FETCh:LTE:SIGNaling1:THRoughput? | Fetch LTE Throughput. Fetches the uplink and downlink throughput results of the LTE signaling connection. | None |
| FETCh:LTE:MEASurement1:MEValuation:STATe? | Read LTE MultiEval State. Reads the main state of the LTE multi-evaluation measurement. | None |
| FETCh:LTE:MEASurement1:MEValuation:MODulation:AVERage? | Fetch LTE Modulation Average. Fetches the average modulation results: EVM, magnitude error, phase error, I/Q offset, frequency error, timing error and TX power. | None |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:BASE:REFerence:FREQuency:SOURce <Source> | Set Reference Frequency Source. Selects the internal or an external reference frequency source for the instrument. | Text: INTernal,EXTernal |
| SYSTem:BASE:REFerence:FREQuency:SOURce? | Read Reference Frequency Source. Reads the selected reference frequency source. | None |
| SYSTem:BASE:REFerence:FREQuency <Freq> | Set External Reference Frequency. Sets the expected external reference frequency in Hz when the external reference source is selected. | Number |
| SYSTem:BASE:REFerence:FREQuency? | Read External Reference Frequency. Reads the expected external reference frequency in Hz. | None |
| SYSTem:ERRor:ALL? | Read Error Queue. Queries and deletes all entries in the error queue. | None |
| SYSTem:ERRor:COUNt? | Read Error Count. Queries the number of entries currently in the error queue. | None |
| SYSTem:RESet:BASE | Reset Base Settings. Resets the base settings to the default values suitable for remote operation. | None |
| SYSTem:RESet:ALL | Reset All Settings. Resets the entire instrument including the base settings and all firmware applications. | None |
| SYSTem:PRESet:BASE | Preset Base Settings. Presets the base settings to the default values suitable for manual operation. | None |
| SYSTem:PRESet:ALL | Preset All Settings. Presets the entire instrument including the base settings and all firmware applications. | None |
| SYSTem:VERSion? | Read SCPI Version. Queries the SCPI version number the instrument complies with. | None |
| SYSTem:BASE:OPTion:LIST? | Read Option List. Returns the list of installed software/hardware options and firmware applications. | None |
| SYSTem:GENerator:ALL:OFF | All Generators Off. Switches off all running generators. | None |
| SYSTem:MEASurement:ALL:OFF | All Measurements Off. Switches off all running measurements. | None |
| SYSTem:SIGNaling:ALL:OFF | All Signaling Off. Switches off all signaling applications (cells / network emulators). | None |
| Command | What it does | Arguments |
|---|---|---|
| READ:GPRF:MEASurement1:POWer:CURRent? | Read Power Current. Starts the measurement and returns the current power results of all measured segments in dBm. | None |
| READ:GPRF:MEASurement1:POWer:CURRent:RMS? | Read Power Current RMS. Starts the measurement and returns the current RMS power results in dBm. | None |
| READ:GPRF:MEASurement1:POWer:AVERage? | Read Power Average. Starts the measurement and returns the average power results of all measured segments in dBm. | None |
| READ:GPRF:MEASurement1:POWer:SDEViation? | Read Power Standard Deviation. Starts the measurement and returns the standard deviation of the power results in dB. | None |
| READ:GPRF:MEASurement1:FFTSanalyzer:POWer:AVERage? | Read FFT Power Average. Starts the measurement and returns the average FFT spectrum trace in dBm. | None |
| READ:GPRF:MEASurement1:EPSensor? | Read Power Sensor Results. Starts the measurement and returns the external power sensor power results in dBm. | None |
| READ:LTE:SIGNaling1:THRoughput? | Read LTE Throughput. Starts the throughput measurement and returns the uplink and downlink throughput results. | None |
| READ:LTE:MEASurement1:MEValuation:MODulation:AVERage? | Read LTE Modulation Average. Starts the measurement and returns the average LTE uplink modulation results. | None |
| Command | What it does | Arguments |
|---|---|---|
| ROUTe:GPRF:GENerator1:SCENario:SALone <Connector>,<Converter> | Route Generator Standalone. Selects the RF output connector and TX module used for the generated RF signal. | Text: RF1C,RF1O,RF2C,RF3C,RF3O,RF4C; Text: TX1,TX2 |
| ROUTe:GPRF:GENerator1:SCENario? | Read Generator Scenario. Reads the active routing scenario of the GPRF generator. | None |
| ROUTe:GPRF:MEASurement1:SCENario:SALone <Connector>,<Converter> | Route Measurement Standalone. Activates the standalone scenario and selects the RF input connector and RX module for the GPRF measurement. | Text: RF1C,RF2C,RF3C,RF4C; Text: RX1,RX2 |
| ROUTe:GPRF:MEASurement1:SCENario:CSPath <Master> | Route Measurement Combined Path. Activates the combined signal path scenario and selects the controlling signaling application, for example 'LTE Sig1'. | Text |
| ROUTe:GPRF:MEASurement1:SCENario? | Read Measurement Scenario. Reads the active routing scenario of the GPRF measurement (SALone or CSPath). | None |
| ROUTe:LTE:MEASurement1:SCENario:SALone <Connector>,<Converter> | Route LTE Measurement Standalone. Activates the standalone scenario and selects the RF input path for the LTE uplink measurement. | Text: RF1C,RF2C,RF3C,RF4C; Text: RX1,RX2 |
| ROUTe:LTE:MEASurement1:SCENario? | Read LTE Measurement Scenario. Reads the active routing scenario of the LTE measurement application. | None |
| Command | What it does | Arguments |
|---|---|---|
| INITiate:GPRF:MEASurement1:POWer | Start Power Measurement. Starts or restarts the GPRF power measurement and puts it into the RUN state. | None |
| INITiate:GPRF:MEASurement1:FFTSanalyzer | Start FFT Measurement. Starts or restarts the FFT spectrum analyzer measurement. | None |
| INITiate:GPRF:MEASurement1:SPECtrum | Start Spectrum Measurement. Starts or restarts the spectrum measurement. | None |
| INITiate:GPRF:MEASurement1:IQVSlot | Start IQVSlot Measurement. Starts or restarts the I/Q vs slot measurement. | None |
| INITiate:GPRF:MEASurement1:EPSensor | Start Power Sensor Measurement. Starts or restarts the external power sensor measurement. | None |
| INITiate:LTE:SIGNaling1:THRoughput | Start LTE Throughput Measurement. Starts or restarts the LTE signaling throughput measurement. | None |
| INITiate:LTE:MEASurement1:MEValuation | Start LTE MultiEval Measurement. Starts or restarts the LTE uplink multi-evaluation measurement. | None |
| Command | What it does | Arguments |
|---|---|---|
| STOP:GPRF:MEASurement1:POWer | Stop Power Measurement. Halts the power measurement and puts it into the RDY state while keeping the results. | None |
| STOP:GPRF:MEASurement1:FFTSanalyzer | Stop FFT Measurement. Halts the FFT measurement and keeps the results. | None |
| STOP:GPRF:MEASurement1:SPECtrum | Stop Spectrum Measurement. Halts the spectrum measurement and keeps the results. | None |
| STOP:GPRF:MEASurement1:IQVSlot | Stop IQVSlot Measurement. Halts the I/Q vs slot measurement and keeps the results. | None |
| STOP:GPRF:MEASurement1:EPSensor | Stop Power Sensor Measurement. Halts the external power sensor measurement and keeps the results. | None |
| STOP:LTE:SIGNaling1:THRoughput | Stop LTE Throughput Measurement. Halts the LTE throughput measurement and keeps the results. | None |
| STOP:LTE:MEASurement1:MEValuation | Stop LTE MultiEval Measurement. Halts the LTE multi-evaluation measurement and keeps the results. | None |
| Command | What it does | Arguments |
|---|---|---|
| ABORt:GPRF:MEASurement1:POWer | Abort Power Measurement. Halts the power measurement and puts it into the OFF state; all results are set to NAV. | None |
| ABORt:GPRF:MEASurement1:FFTSanalyzer | Abort FFT Measurement. Halts the FFT measurement and clears all results. | None |
| ABORt:GPRF:MEASurement1:SPECtrum | Abort Spectrum Measurement. Halts the spectrum measurement and clears all results. | None |
| ABORt:GPRF:MEASurement1:IQVSlot | Abort IQVSlot Measurement. Halts the I/Q vs slot measurement and clears all results. | None |
| ABORt:GPRF:MEASurement1:EPSensor | Abort Power Sensor Measurement. Halts the external power sensor measurement and clears all results. | None |
| ABORt:LTE:SIGNaling1:THRoughput | Abort LTE Throughput Measurement. Halts the LTE throughput measurement and clears all results. | None |
| ABORt:LTE:MEASurement1:MEValuation | Abort LTE MultiEval Measurement. Halts the LTE multi-evaluation measurement and clears all results. | None |
| Command | What it does | Arguments |
|---|---|---|
| CALL:LTE:SIGNaling1:PSWitched:ACTion CONNect | Connect LTE UE. Initiates a mobile-terminated packet-switched connection setup to the attached UE. | None |
| CALL:LTE:SIGNaling1:PSWitched:ACTion DISConnect | Disconnect LTE UE. Releases the packet-switched connection to the UE. | None |
| CALL:LTE:SIGNaling1:PSWitched:ACTion DETach | Detach LTE UE. Detaches the UE from the simulated LTE network. | None |
| CALL:LTE:SIGNaling1:PSWitched:ACTion SMS | Send LTE SMS. Sends a short message to the connected UE. | None |
| CALL:LTE:SIGNaling1:PSWitched:ACTion HANDover | Handover LTE Connection. Initiates a handover within the LTE signaling application or to another signaling application. | None |
| Command | What it does | Arguments |
|---|---|---|
| SENSe:LTE:SIGNaling1:UEReport:PCC:RSRQ? | Read LTE UE RSRQ. Reads the RSRQ reported by the UE as a dimensionless index (-30 to 46). | None |
| SENSe:LTE:SIGNaling1:UEReport:PCC:RSRQ:RANGe? | Read LTE UE RSRQ Range. Reads the lower and upper RSRQ bounds in dB that correspond to the reported index. | None |
| SENSe:BASE:REFerence:FREQuency:LOCKed? | Read Reference Locked. Queries whether the instrument is locked to the selected reference frequency. | None |
| SENSe:BASE:TEMPerature:OPERating:INTernal? | Read Internal Temperature. Queries the average internal temperature measured at the RF modules in degrees C. | None |
| Command | What it does | Arguments |
|---|---|---|
| CALCulate:GPRF:MEASurement1:POWer:AVERage? | Calculate Power Average Limits. Returns the limit check results for the average power instead of the measured values. | None |
| CALCulate:LTE:MEASurement1:MEValuation:MODulation:AVERage? | Calculate LTE Modulation Average Limits. Returns the limit check results for the average LTE modulation measurement instead of the measured values. | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). | None |
| *RST | Reset. Resets the current sub-instrument to its default state. | None |
| *CLS | Clear Status. Clears the status byte, event registers and the output buffer. | None |
| *ESR? | Read Event Status Register. Returns the contents of the standard event status register (0 to 255) and clears it. | None |
| *STB? | Read Status Byte. Returns the contents of the status byte in decimal form. | None |
| *OPC | Set Operation Complete Bit. Sets bit 0 of the event status register when all preceding commands are complete. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *WAI | Wait To Continue. Waits until all pending operations are complete before continuing. | None |
| *SAV <Memory> | Save State. Stores the current instrument settings in intermediate memory 0 to 99. | Number: 0,99 |
| *RCL <Memory> | Recall State. Recalls instrument settings from intermediate memory 0 to 99. | Number: 0,99 |
| *TRG | Trigger Bus. Generates a software (bus) trigger event. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Rohde & Schwarz's programming documentation for the CMW290 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Rohde & Schwarz's programming manual: check it before you rely on an edge case. Last updated September 27, 2026.
Yes. The Rohde & Schwarz CMW290 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 316 SCPI commands for it: 162 queries that read values or state, and 154 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, SOURce:GPRF:GENerator1:STATe ON and CONFigure:GPRF:MEASurement1:RFSettings:FREQuency?.
CONFigure:GPRF:MEASurement1:RFSettings:FREQuency? (read analyzer frequency). Reads the center frequency of the RF analyzer in Hz. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Rohde & Schwarz CMW290 through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.