| CONFigure:GPRF:MEASurement1:RFSettings:FREQuency <Freq> | Set Analyzer Frequency. Sets the center frequency of the RF analyzer in Hz. | Number |
| CONFigure:GPRF:MEASurement1:RFSettings:FREQuency? | Read Analyzer Frequency. Reads the center frequency of the RF analyzer in Hz. | None |
| CONFigure:GPRF:MEASurement1:RFSettings:ENPower <Power> | Set Analyzer Expected Power. Sets the expected nominal power of the measured RF signal in dBm. | Number |
| CONFigure:GPRF:MEASurement1:RFSettings:ENPower? | Read Analyzer Expected Power. Reads the expected nominal power of the measured RF signal in dBm. | None |
| CONFigure:GPRF:MEASurement1:RFSettings:EATTenuation <Atten> | Set Analyzer External Attenuation. Sets the external attenuation (or gain, if negative) at the RF input connector in dB (-50 dB to 90 dB). | Number |
| CONFigure:GPRF:MEASurement1:RFSettings:EATTenuation? | Read Analyzer External Attenuation. Reads the external attenuation configured for the RF input path in dB. | None |
| CONFigure:GPRF:MEASurement1:RFSettings:UMARgin <Margin> | Set Analyzer User Margin. Sets the margin added to the expected nominal power to determine the reference power in dB. | Number |
| CONFigure:GPRF:MEASurement1:RFSettings:UMARgin? | Read Analyzer User Margin. Reads the user margin used to determine the reference power in dB. | None |
| CONFigure:GPRF:MEASurement1:RFSettings:MLOFfset <Offset> | Set Analyzer Mixer Level Offset. Varies the input level of the mixer in the analyzer path in dB (-10 dB to 16 dB). | Number |
| CONFigure:GPRF:MEASurement1:RFSettings:MLOFfset? | Read Analyzer Mixer Level Offset. Reads the mixer level offset of the analyzer path in dB. | None |
| CONFigure:GPRF:MEASurement1:RFSettings:FOFFset <Offset> | Set Analyzer Frequency Offset. Sets a positive or negative frequency offset added to the analyzer center frequency in Hz (-100 kHz to 100 kHz). | Number |
| CONFigure:GPRF:MEASurement1:RFSettings:FOFFset? | Read Analyzer Frequency Offset. Reads the analyzer frequency offset in Hz. | None |
| CONFigure:GPRF:MEASurement1:POWer:MODE <Mode> | Set Power Measurement Mode. Selects the power measurement mode used when list mode is off. | Text: POWer,STATistic |
| CONFigure:GPRF:MEASurement1:POWer:MODE? | Read Power Measurement Mode. Reads the selected power measurement mode. | None |
| CONFigure:GPRF:MEASurement1:POWer:REPetition <Repetition> | Set Power Repetition. Selects whether the power measurement is stopped after one cycle or repeated continuously. | Text: SINGleshot,CONTinuous |
| CONFigure:GPRF:MEASurement1:POWer:REPetition? | Read Power Repetition. Reads the repetition mode of the power measurement. | None |
| CONFigure:GPRF:MEASurement1:POWer:SCOunt <Count> | Set Power Statistic Count. Specifies the number of measurement intervals per measurement cycle (1 to 100000). | Number |
| CONFigure:GPRF:MEASurement1:POWer:SCOunt? | Read Power Statistic Count. Reads the statistic count of the power measurement. | None |
| CONFigure:GPRF:MEASurement1:POWer:MLENgth <Seconds> | Set Power Measurement Length. Sets the evaluation interval used to calculate one set of current power results (RMS, minimum, maximum) in seconds. | Number |
| CONFigure:GPRF:MEASurement1:POWer:MLENgth? | Read Power Measurement Length. Reads the power measurement evaluation interval in seconds. | None |
| CONFigure:GPRF:MEASurement1:POWer:SLENgth <Seconds> | Set Power Step Length. Sets the time between the beginnings of two consecutive measurement lengths in seconds. | Number |
| CONFigure:GPRF:MEASurement1:POWer:SLENgth? | Read Power Step Length. Reads the step length of the power measurement in seconds. | None |
| CONFigure:GPRF:MEASurement1:POWer:TOUT <Seconds> | Set Power Timeout. Defines a timeout for the power measurement in seconds; 0 s means an infinite timeout. | Number |
| CONFigure:GPRF:MEASurement1:POWer:TOUT? | Read Power Timeout. Reads the power measurement timeout in seconds. | None |
| CONFigure:GPRF:MEASurement1:POWer:PDEFset <Name> | Set Power Predefined Set. Loads a predefined parameter set for the power measurement. | Text |
| CONFigure:GPRF:MEASurement1:POWer:PDEFset? | Read Power Predefined Set. Reads the name of the loaded predefined power parameter set. | None |
| CONFigure:GPRF:MEASurement1:DISPlay <Tab> | Set Measurement Display Tab. Selects the measurement tab shown on the instrument display during remote control. | Text: POWer,SPECtrum,FFTSanalyzer,IQRecorder,IQVSlot,EPSensor |
| CONFigure:GPRF:MEASurement1:DISPlay? | Read Measurement Display Tab. Reads the measurement tab currently shown on the instrument display. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:FSPan <Span> | Set FFT Frequency Span. Configures the frequency span of the FFT spectrum analyzer in Hz. | Number: 1250000,2500000,5000000,10000000,20000000,40000000,80000000,160000000 |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:FSPan? | Read FFT Frequency Span. Reads the frequency span of the FFT spectrum analyzer in Hz. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:FFTLength <Length> | Set FFT Length. Selects the number of samples recorded per measurement interval of the FFT spectrum analyzer. | Number: 1024,2048,4096,8192,16384 |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:FFTLength? | Read FFT Length. Reads the configured FFT length. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:DETector <Detector> | Set FFT Detector. Defines how the spectrum diagram is calculated from the frequency domain samples. | Text: PEAK,RMS |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:DETector? | Read FFT Detector. Reads the detector used by the FFT spectrum analyzer. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:AMODe <Mode> | Set FFT Averaging Mode. Selects whether the average traces are calculated from linear or logarithmic power values. | Text: LINear,LOGarithmic |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:AMODe? | Read FFT Averaging Mode. Reads the averaging mode of the FFT spectrum analyzer. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:REPetition <Repetition> | Set FFT Repetition. Selects whether the FFT measurement is stopped after one cycle or repeated continuously. | Text: SINGleshot,CONTinuous |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:REPetition? | Read FFT Repetition. Reads the repetition mode of the FFT spectrum analyzer. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:SCOunt <Count> | Set FFT Statistic Count. Specifies the number of measurement intervals per single shot for the FFT measurement (1 to 1000). | Number |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:SCOunt? | Read FFT Statistic Count. Reads the statistic count of the FFT measurement. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:TOUT <Seconds> | Set FFT Timeout. Defines a timeout for the FFT measurement in seconds. | Number |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:TOUT? | Read FFT Timeout. Reads the FFT measurement timeout in seconds. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:MOEXception ON | Turn On FFT Measure On Exception. Accepts faulty FFT results instead of rejecting them. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:MOEXception OFF | Turn Off FFT Measure On Exception. Rejects faulty FFT results. | None |
| CONFigure:GPRF:MEASurement1:FFTSanalyzer:MOEXception? | Read FFT Measure On Exception. Reads whether faulty FFT results are accepted or rejected. | None |
| CONFigure:GPRF:MEASurement1:SPECtrum:AMODe <Mode> | Set Spectrum Averaging Mode. Defines how the average traces are calculated from the current spectrum results. | Text: LINear,LOGarithmic |
| CONFigure:GPRF:MEASurement1:SPECtrum:AMODe? | Read Spectrum Averaging Mode. Reads the averaging mode of the spectrum measurement. | None |
| CONFigure:GPRF:MEASurement1:SPECtrum:REPetition <Repetition> | Set Spectrum Repetition. Selects whether the spectrum measurement is stopped after one cycle or repeated continuously. | Text: SINGleshot,CONTinuous |
| CONFigure:GPRF:MEASurement1:SPECtrum:REPetition? | Read Spectrum Repetition. Reads the repetition mode of the spectrum measurement. | None |
| CONFigure:GPRF:MEASurement1:SPECtrum:SCOunt <Count> | Set Spectrum Statistic Count. Specifies the number of measurement intervals per single shot for the spectrum measurement (1 to 1000). | Number |
| CONFigure:GPRF:MEASurement1:SPECtrum:SCOunt? | Read Spectrum Statistic Count. Reads the statistic count of the spectrum measurement. | None |
| CONFigure:GPRF:MEASurement1:SPECtrum:TOUT <Seconds> | Set Spectrum Timeout. Defines a timeout for the spectrum measurement in seconds; 0 s means an infinite timeout. | Number |
| CONFigure:GPRF:MEASurement1:SPECtrum:TOUT? | Read Spectrum Timeout. Reads the spectrum measurement timeout in seconds. | None |
| CONFigure:WLAN:SIGNaling1:CONNection:STANdard <Standard> | Set WLAN Standard. Selects the IEEE 802.11 standard (b, a, g, g OFDM, a/n, g/n, g OFDM/n, ac, ax). | Text: BSTD,ASTD,GSTD,GOSTd,ANSTd,GNSTd,GONStd,ACSTd,AXSTd |
| CONFigure:WLAN:SIGNaling1:CONNection:STANdard? | Read WLAN Standard. Reads the selected IEEE 802.11 standard (b, a, g, g OFDM, a/n, g/n, g OFDM/n, ac, ax). | None |
| CONFigure:WLAN:SIGNaling1:CONNection:OMODe <Mode> | Set WLAN Operation Mode. Selects the simulated WLAN entity: access point, station or Hotspot 2.0 access point. | Text: AP,STATion,HSPot2 |
| CONFigure:WLAN:SIGNaling1:CONNection:OMODe? | Read WLAN Operation Mode. Reads the selected simulated WLAN entity: access point, station or Hotspot 2.0 access point. | None |
| CONFigure:WLAN:SIGNaling1:CONNection:SSID <SSID> | Set WLAN SSID. Sets the service set identifier (string, up to 32 ASCII characters). | Text |
| CONFigure:WLAN:SIGNaling1:CONNection:SSID? | Read WLAN SSID. Reads the service set identifier (string, up to 32 ASCII characters). | None |
| CONFigure:WLAN:SIGNaling1:CONNection:BSSid <BSSID> | Set WLAN BSSID. Sets the 48-bit MAC address of the tester WLAN interface (hex, e.g. #H001122334455). | Text |
| CONFigure:WLAN:SIGNaling1:CONNection:BSSid? | Read WLAN BSSID. Reads the 48-bit MAC address of the tester WLAN interface (hex, e.g. #H001122334455). | None |
| CONFigure:WLAN:SIGNaling1:CONNection:BEACon <Interval> | Set WLAN Beacon Interval. Sets the beacon interval in time units of 1024 us (20 to 16000). | Number: 20,16000 |
| CONFigure:WLAN:SIGNaling1:CONNection:BEACon? | Read WLAN Beacon Interval. Reads the beacon interval in time units of 1024 us (20 to 16000). | None |
| CONFigure:WLAN:SIGNaling1:CONNection:DPERiod <Period> | Set WLAN DTIM Period. Sets the number of beacon intervals between DTIM messages (1 to 10). | Number: 1,10 |
| CONFigure:WLAN:SIGNaling1:CONNection:DPERiod? | Read WLAN DTIM Period. Reads the number of beacon intervals between DTIM messages (1 to 10). | None |
| CONFigure:WLAN:SIGNaling1:CONNection:SECurity:ENCRyption <Type> | Set WLAN Encryption. Sets the encryption type used with WPA/WPA2/WPA3 personal security in AP mode. | Text: AES,TKIP,DISabled,GCMP |
| CONFigure:WLAN:SIGNaling1:CONNection:SECurity:ENCRyption? | Read WLAN Encryption. Reads the encryption type used with WPA/WPA2/WPA3 personal security in AP mode. | None |
| CONFigure:WLAN:SIGNaling1:CONNection:SECurity:PASSphrase <Security_Type>, <Passphrase> | Set WLAN Security Passphrase. Selects the security mechanism and defines the WPA/WPA2/WPA3 personal passphrase. | Text: AUTO,DISabled,OWE,W2ENterprise,W2Personal,W3ENterprise,W3Personal,WENTerprise,WPERsonal; Text |
| CONFigure:WLAN:SIGNaling1:CONNection:STATion:CMODe <Mode> | Set WLAN Station Connection Mode. Selects automatic or manual association behaviour of the simulated station (operation mode Station). | Text: ACONnect,MANual |
| CONFigure:WLAN:SIGNaling1:CONNection:STATion:CMODe? | Read WLAN Station Connection Mode. Reads the selection: automatic or manual association behaviour of the simulated station (operation mode Station). | None |
| CONFigure:WLAN:SIGNaling1:CONNection:DSSS ON | Turn On WLAN DSSS Support. Allows association of 802.11b devices and non-HT management frames in 802.11ac/ax. | None |
| CONFigure:WLAN:SIGNaling1:CONNection:DSSS OFF | Turn Off WLAN DSSS Support. Disables DSSS support in 802.11ac/ax operation. | None |
| CONFigure:WLAN:SIGNaling1:RFSettings:BAND <Band> | Set WLAN Frequency Band. Selects the operating band: sub-6 GHz or 6 GHz. | Text: BS6Ghz,B6GHz |
| CONFigure:WLAN:SIGNaling1:RFSettings:BAND? | Read WLAN Frequency Band. Reads the selected operating band: sub-6 GHz or 6 GHz. | None |
| CONFigure:WLAN:SIGNaling1:RFSettings:CHANnel <Channel> | Set WLAN Channel. Sets the WLAN RF channel number (1 to 196). | Number: 1,196 |
| CONFigure:WLAN:SIGNaling1:RFSettings:CHANnel? | Read WLAN Channel. Reads the WLAN RF channel number (1 to 196). | None |
| CONFigure:WLAN:SIGNaling1:RFSettings:FREQuency <Frequency> | Set WLAN Frequency. Sets the center frequency of the generated WLAN signal and of the analyzer in Hz (70 MHz to 6 GHz). | Number |
| CONFigure:WLAN:SIGNaling1:RFSettings:FREQuency? | Read WLAN Frequency. Reads the center frequency of the generated WLAN signal and of the analyzer in Hz (70 MHz to 6 GHz). | None |
| CONFigure:WLAN:SIGNaling1:RFSettings:OCWidth <Bandwidth> | Set WLAN Channel Bandwidth. Sets the operating channel bandwidth. | Text: BW20,BW40,BW80,BW160 |
| CONFigure:WLAN:SIGNaling1:RFSettings:OCWidth? | Read WLAN Channel Bandwidth. Reads the operating channel bandwidth. | None |
| CONFigure:WLAN:SIGNaling1:RFSettings:BOPower <Power> | Set WLAN Burst Output Power. Sets the burst power of the transmitted WLAN signal in dBm. | Number |
| CONFigure:WLAN:SIGNaling1:RFSettings:BOPower? | Read WLAN Burst Output Power. Reads the burst power of the transmitted WLAN signal in dBm. | None |
| CONFigure:WLAN:SIGNaling1:RFSettings:EATTenuation:INPut <Atten> | Set WLAN Input External Attenuation. Sets the external attenuation at the RF input in dB. | Number |
| CONFigure:WLAN:SIGNaling1:RFSettings:EATTenuation:INPut? | Read WLAN Input External Attenuation. Reads the external attenuation at the RF input in dB. | None |
| CONFigure:WLAN:SIGNaling1:RFSettings:EPEPower <Power> | Set WLAN Expected Peak Envelope Power. Sets the expected peak envelope power of the DUT signal in dBm. | Number |
| CONFigure:WLAN:SIGNaling1:RFSettings:EPEPower? | Read WLAN Expected Peak Envelope Power. Reads the expected peak envelope power of the DUT signal in dBm. | None |
| CONFigure:WLAN:SIGNaling1:PER:PACKets <Packets> | Set WLAN PER Packets. Sets the number of user data MAC packets transmitted to the DUT for the PER measurement. | Number: 1,1000000 |
| CONFigure:WLAN:SIGNaling1:PER:PACKets? | Read WLAN PER Packets. Reads the number of user data MAC packets transmitted to the DUT for the PER measurement. | None |
| CONFigure:WLAN:SIGNaling1:PER:REPetition <Repetition> | Set WLAN PER Repetition. Sets the repetition mode of the PER measurement. | Text: SINGleshot,CONTinuous |
| CONFigure:WLAN:SIGNaling1:PER:REPetition? | Read WLAN PER Repetition. Reads the repetition mode of the PER measurement. | None |
| CONFigure:WLAN:SIGNaling1:FADing:AWGN:ENABle ON | Turn On WLAN Fading AWGN. Enables AWGN insertion via the fading module. | None |
| CONFigure:WLAN:SIGNaling1:FADing:AWGN:ENABle OFF | Turn Off WLAN Fading AWGN. Disables AWGN insertion via the fading module. | None |
| CONFigure:WLAN:SIGNaling1:FADing:AWGN:SNRatio <SNR> | Set WLAN Fading AWGN SNR. Sets the signal to noise ratio of the inserted AWGN in dB (0 to 40). | Number: 0,40 |
| CONFigure:WLAN:SIGNaling1:FADing:AWGN:SNRatio? | Read WLAN Fading AWGN SNR. Reads the signal to noise ratio of the inserted AWGN in dB (0 to 40). | None |
| CONFigure:WLAN:MEASurement1:ISIGnal:STANdard <Standard> | Set WLAN Meas Standard. Selects the IEEE 802.11 standard of the measured signal (b/g DSSS, a/g OFDM, n, ac, ax, p). | Text: DSSS,LOFDm,HTOFdm,VHTofdm,HEOFdm,POFDm |
| CONFigure:WLAN:MEASurement1:ISIGnal:STANdard? | Read WLAN Meas Standard. Reads the selected IEEE 802.11 standard of the measured signal (b/g DSSS, a/g OFDM, n, ac, ax, p). | None |
| CONFigure:WLAN:MEASurement1:ISIGnal:BWIDth <Bandwidth> | Set WLAN Meas Bandwidth. Selects the channel bandwidth of the measured signal. | Text: BW05mhz,BW10mhz,BW20mhz,BW40mhz,BW80mhz,BW16mhz,BW88mhz |
| CONFigure:WLAN:MEASurement1:ISIGnal:BWIDth? | Read WLAN Meas Bandwidth. Reads the selected channel bandwidth of the measured signal. | None |
| CONFigure:WLAN:MEASurement1:RFSettings:FREQuency <Frequency> | Set WLAN Meas Frequency. Sets the analyzer center frequency in Hz (center of the received WLAN channel). | Number |
| CONFigure:WLAN:MEASurement1:RFSettings:FREQuency? | Read WLAN Meas Frequency. Reads the analyzer center frequency in Hz (center of the received WLAN channel). | None |
| CONFigure:WLAN:MEASurement1:RFSettings:FREQuency:BAND <Band> | Set WLAN Meas Frequency Band. Selects the WLAN frequency band. | Text: B24Ghz,B4GHz,B5GHz,B6GHz |
| CONFigure:WLAN:MEASurement1:RFSettings:FREQuency:BAND? | Read WLAN Meas Frequency Band. Reads the selected WLAN frequency band. | None |
| CONFigure:WLAN:MEASurement1:RFSettings:ENPower <Power> | Set WLAN Meas Expected Power. Sets the expected nominal power of the measured RF signal in dBm. | Number |
| CONFigure:WLAN:MEASurement1:RFSettings:ENPower? | Read WLAN Meas Expected Power. Reads the expected nominal power of the measured RF signal in dBm. | None |
| CONFigure:WLAN:MEASurement1:RFSettings:EATTenuation <Atten> | Set WLAN Meas External Attenuation. Sets the external attenuation at the RF input in dB (-50 to 90). | Number: -50,90 |
| CONFigure:WLAN:MEASurement1:RFSettings:EATTenuation? | Read WLAN Meas External Attenuation. Reads the external attenuation at the RF input in dB (-50 to 90). | None |
| CONFigure:WLAN:MEASurement1:RFSettings:UMARgin <Margin> | Set WLAN Meas User Margin. Sets the margin added to the expected nominal power to determine the reference power in dB. | Number |
| CONFigure:WLAN:MEASurement1:RFSettings:UMARgin? | Read WLAN Meas User Margin. Reads the margin added to the expected nominal power to determine the reference power in dB. | None |
| CONFigure:WLAN:MEASurement1:MEValuation:REPetition <Repetition> | Set WLAN Meas Repetition. Selects single-shot or continuous WLAN multi-evaluation measurement. | Text: SINGleshot,CONTinuous |
| CONFigure:WLAN:MEASurement1:MEValuation:REPetition? | Read WLAN Meas Repetition. Reads the selection: single-shot or continuous WLAN multi-evaluation measurement. | None |
| CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:MODulation <Count> | Set WLAN Meas Modulation Count. Sets the statistic count for modulation measurements (1 to 2000). | Number: 1,2000 |
| CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:MODulation? | Read WLAN Meas Modulation Count. Reads the statistic count for modulation measurements (1 to 2000). | None |
| CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:TSMask <Count> | Set WLAN Meas Spectrum Mask Count. Sets the statistic count for the transmit spectrum mask measurement (1 to 1000). | Number: 1,1000 |
| CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:TSMask? | Read WLAN Meas Spectrum Mask Count. Reads the statistic count for the transmit spectrum mask measurement (1 to 1000). | None |
| CONFigure:WLAN:MEASurement1:MEValuation:TOUT <Seconds> | Set WLAN Meas Timeout. Defines a timeout for the WLAN measurement in seconds. | Number |
| CONFigure:WLAN:MEASurement1:MEValuation:TOUT? | Read WLAN Meas Timeout. Reads the timeout for the WLAN measurement in seconds. | None |
| CONFigure:WLAN:MEASurement1:MEValuation:SCONdition <Condition> | Set WLAN Meas Stop Condition. Defines whether the measurement stops on a limit failure. | Text: NONE,SLFail |
| CONFigure:WLAN:MEASurement1:MEValuation:SCONdition? | Read WLAN Meas Stop Condition. Reads whether the measurement stops on a limit failure. | None |
| CONFigure:WLAN:MEASurement1:MEValuation:MOEXception ON | Turn On WLAN Meas On Exception. Results identified as faulty are never rejected. | None |
| CONFigure:WLAN:MEASurement1:MEValuation:MOEXception OFF | Turn Off WLAN Meas On Exception. Faulty results are rejected. | None |
| CONFigure:BLUetooth:SIGNaling1:STANdard <Standard> | Set BT Standard. Selects classic (BR/EDR) or low energy (LE) signaling. | Text: CLASsic,LESignaling |
| CONFigure:BLUetooth:SIGNaling1:STANdard? | Read BT Standard. Reads the selection: classic (BR/EDR) or low energy (LE) signaling. | None |
| CONFigure:BLUetooth:SIGNaling1:OPMode <Mode> | Set BT Operating Mode. Selects the operating mode: connection test, RF test mode, echo, profiles, audio or LE test mode. | Text: CNTest,RFTest,ECMode,PROFiles,AUDio,LETMode |
| CONFigure:BLUetooth:SIGNaling1:OPMode? | Read BT Operating Mode. Reads the selected operating mode: connection test, RF test mode, echo, profiles, audio or LE test mode. | None |
| CONFigure:BLUetooth:SIGNaling1:CONNection:BTYPe <Type> | Set BT Burst Type. Selects the burst type of the connection: basic rate, enhanced data rate or low energy. | Text: BR,EDR,LE |
| CONFigure:BLUetooth:SIGNaling1:CONNection:BTYPe? | Read BT Burst Type. Reads the selected burst type of the connection: basic rate, enhanced data rate or low energy. | None |
| CONFigure:BLUetooth:SIGNaling1:TMODe <Mode> | Set BT Test Mode. Selects the BR/EDR test mode entered by the EUT: loopback or TX test. | Text: LOOPback,TXTest |
| CONFigure:BLUetooth:SIGNaling1:TMODe? | Read BT Test Mode. Reads the selected BR/EDR test mode entered by the EUT: loopback or TX test. | None |
| CONFigure:BLUetooth:SIGNaling1:CONNection:BDADdress:EUT <Address> | Set BT EUT Address. Sets the BD_ADDR of the default device to page (12 hex digits, e.g. #H0123456789AB). | Text |
| CONFigure:BLUetooth:SIGNaling1:CONNection:BDADdress:EUT? | Read BT EUT Address. Reads the BD_ADDR of the default device to page (12 hex digits, e.g. #H0123456789AB). | None |
| CONFigure:BLUetooth:SIGNaling1:CONNection:BDADdress:CMW <Address> | Set BT Tester Address. Sets the BD_ADDR of the tester (12 hex digits). | Text |
| CONFigure:BLUetooth:SIGNaling1:CONNection:BDADdress:CMW? | Read BT Tester Address. Reads the BD_ADDR of the tester (12 hex digits). | None |
| CONFigure:BLUetooth:SIGNaling1:CONNection:PAGing:PTARget <Index> | Set BT Paging Target. Selects the device to page from the inquiry target catalog (0 = default device). | Number |
| CONFigure:BLUetooth:SIGNaling1:CONNection:PAGing:PTARget? | Read BT Paging Target. Reads the selected device to page from the inquiry target catalog (0 = default device). | None |
| CONFigure:BLUetooth:SIGNaling1:CONNection:INQuiry:NOResponses <Number> | Set BT Inquiry Max Responses. Sets the maximum number of inquiry responses (0 = unlimited, max 12). | Number: 0,12 |
| CONFigure:BLUetooth:SIGNaling1:CONNection:INQuiry:NOResponses? | Read BT Inquiry Max Responses. Reads the maximum number of inquiry responses (0 = unlimited, max 12). | None |
| CONFigure:BLUetooth:SIGNaling1:CONNection:PACKets:PTYPe:BRATe <Type> | Set BT BR Packet Type. Sets the basic rate packet type. | Text: DH1,DH3,DH5 |
| CONFigure:BLUetooth:SIGNaling1:CONNection:PACKets:PTYPe:BRATe? | Read BT BR Packet Type. Reads the basic rate packet type. | None |
| CONFigure:BLUetooth:SIGNaling1:CONNection:PACKets:PTYPe:EDRate <Type> | Set BT EDR Packet Type. Sets the enhanced data rate packet type. | Text: E21P,E23P,E25P,E31P,E33P,E35P |
| CONFigure:BLUetooth:SIGNaling1:CONNection:PACKets:PTYPe:EDRate? | Read BT EDR Packet Type. Reads the enhanced data rate packet type. | None |
| CONFigure:BLUetooth:SIGNaling1:CONNection:PACKets:PATTern:BRATe <Pattern> | Set BT BR Payload Pattern. Sets the payload bit pattern for basic rate test mode. | Text: ALL0,ALL1,P11,P44,PRBS9,ALT |
| CONFigure:BLUetooth:SIGNaling1:CONNection:PACKets:PATTern:BRATe? | Read BT BR Payload Pattern. Reads the payload bit pattern for basic rate test mode. | None |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:LEVel <Level> | Set BT TX Level. Sets the absolute TX level of the tester signal in dBm. | Number |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:LEVel? | Read BT TX Level. Reads the absolute TX level of the tester signal in dBm. | None |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:ENPower <Power> | Set BT Expected Power. Sets the expected nominal power of the EUT signal in dBm. | Number |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:ENPower? | Read BT Expected Power. Reads the expected nominal power of the EUT signal in dBm. | None |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:UMARgin <Margin> | Set BT User Margin. Sets the user margin added to the expected nominal power in dB. | Number |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:UMARgin? | Read BT User Margin. Reads the user margin added to the expected nominal power in dB. | None |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:EATTenuation:INPut <Atten> | Set BT Input External Attenuation. Sets the external attenuation at the input connector in dB. | Number: -50,90 |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:EATTenuation:INPut? | Read BT Input External Attenuation. Reads the external attenuation at the input connector in dB. | None |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:EATTenuation:OUTPut <Atten> | Set BT Output External Attenuation. Sets the external attenuation at the output connector in dB. | Number: -50,90 |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:EATTenuation:OUTPut? | Read BT Output External Attenuation. Reads the external attenuation at the output connector in dB. | None |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:HOPPing ON | Turn On BT Hopping. Enables frequency hopping. | None |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:HOPPing OFF | Turn Off BT Hopping. Disables frequency hopping. | None |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:CHANnel:TMODe <Channel> | Set BT LE Test Mode Channel. Sets the RF channel for LE test mode (0 to 39). | Number: 0,39 |
| CONFigure:BLUetooth:SIGNaling1:RFSettings:CHANnel:TMODe? | Read BT LE Test Mode Channel. Reads the RF channel for LE test mode (0 to 39). | None |
| CONFigure:BLUetooth:SIGNaling1:RXQuality:PACKets:BEDR <Packets> | Set BT RX Quality Packets. Defines the number of data packets measured per BER statistics cycle. | Number: 1,400000 |
| CONFigure:BLUetooth:SIGNaling1:RXQuality:PACKets:BEDR? | Read BT RX Quality Packets. Reads the number of data packets measured per BER statistics cycle. | None |
| CONFigure:BLUetooth:SIGNaling1:RXQuality:REPetition <Repetition> | Set BT RX Quality Repetition. Selects single-shot or continuous RX quality measurement. | Text: SINGleshot,CONTinuous |
| CONFigure:BLUetooth:SIGNaling1:RXQuality:REPetition? | Read BT RX Quality Repetition. Reads the selection: single-shot or continuous RX quality measurement. | None |
| CONFigure:BLUetooth:SIGNaling1:RXQuality:TOUT <Seconds> | Set BT RX Quality Timeout. Defines a timeout for the RX quality measurement in seconds. | Number |
| CONFigure:BLUetooth:SIGNaling1:RXQuality:TOUT? | Read BT RX Quality Timeout. Reads the timeout for the RX quality measurement in seconds. | None |
| CONFigure:BASE:FDCorrection:CTABle:CREate <Table_Name>, <Freq_Loss_Pairs> | Create Correction Table. Creates a frequency-dependent attenuation table; pairs are <Frequency Hz>, <Correction dB> (e.g. 1E9, 0.5, 2E9, 0.7). | Text; Text |
| CONFigure:BASE:FDCorrection:CTABle:DELete <Table_Name> | Delete Correction Table. Deletes the named correction table. | Text |
| CONFigure:BASE:FDCorrection:CTABle:CATalog? | Read Correction Table Catalog. Returns the names of all existing correction tables. | None |
| CONFigure:FDCorrection:ACTivate <Connector>, <Table_Name>, <Direction> | Activate Correction Table. Activates a correction table for an RF connector in direction RXTX, RX or TX. | Text: RF1C,RF1O,RF2C,RF3C,RF3O,RF4C; Text; Text: RXTX,RX,TX |
| CONFigure:FDCorrection:DEACtivate <Connector> | Deactivate Correction Table. Deactivates all correction tables of an RF connector. | Text: RF1C,RF1O,RF2C,RF3C,RF3O,RF4C |