Radio Test Set · SCPI command reference

Rohde & Schwarz CMW270 SCPI commands

The Rohde & Schwarz CMW270 radio test set is controlled remotely with SCPI commands. TestFlow's instrument library holds 318 commands for it, 167 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the CMW270 on a real bench.

Commands
318
Queries
167
Subsystems
16
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Rohde & Schwarz CMW270 and writes the report from the measured results.

Get started

Control the Rohde & Schwarz CMW270 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Rohde & Schwarz CMW270's VISA address

# Paste the address of your Rohde & Schwarz CMW270 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("SOURce:GPRF:GENerator1:STATe ON")  # Turn On Generator
print(inst.query("CONFigure:GPRF:MEASurement1:RFSettings:FREQuency?"))  # Read Analyzer Frequency

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Rohde & Schwarz CMW270 and writes the report from the measured results.

Get started

Run a CMW270 test without writing code

Describe the test in a sentence, for example “turn on generator on the CMW270, then read analyzer frequency and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

318 commands in 16 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Configure (CONFigure) (167)

CommandWhat it doesArguments
CONFigure:GPRF:MEASurement1:RFSettings:FREQuency <Freq>Set Analyzer Frequency. Sets the center frequency of the RF analyzer in Hz.Number
CONFigure:GPRF:MEASurement1:RFSettings:FREQuency?Read Analyzer Frequency. Reads the center frequency of the RF analyzer in Hz.None
CONFigure:GPRF:MEASurement1:RFSettings:ENPower <Power>Set Analyzer Expected Power. Sets the expected nominal power of the measured RF signal in dBm.Number
CONFigure:GPRF:MEASurement1:RFSettings:ENPower?Read Analyzer Expected Power. Reads the expected nominal power of the measured RF signal in dBm.None
CONFigure:GPRF:MEASurement1:RFSettings:EATTenuation <Atten>Set Analyzer External Attenuation. Sets the external attenuation (or gain, if negative) at the RF input connector in dB (-50 dB to 90 dB).Number
CONFigure:GPRF:MEASurement1:RFSettings:EATTenuation?Read Analyzer External Attenuation. Reads the external attenuation configured for the RF input path in dB.None
CONFigure:GPRF:MEASurement1:RFSettings:UMARgin <Margin>Set Analyzer User Margin. Sets the margin added to the expected nominal power to determine the reference power in dB.Number
CONFigure:GPRF:MEASurement1:RFSettings:UMARgin?Read Analyzer User Margin. Reads the user margin used to determine the reference power in dB.None
CONFigure:GPRF:MEASurement1:RFSettings:MLOFfset <Offset>Set Analyzer Mixer Level Offset. Varies the input level of the mixer in the analyzer path in dB (-10 dB to 16 dB).Number
CONFigure:GPRF:MEASurement1:RFSettings:MLOFfset?Read Analyzer Mixer Level Offset. Reads the mixer level offset of the analyzer path in dB.None
CONFigure:GPRF:MEASurement1:RFSettings:FOFFset <Offset>Set Analyzer Frequency Offset. Sets a positive or negative frequency offset added to the analyzer center frequency in Hz (-100 kHz to 100 kHz).Number
CONFigure:GPRF:MEASurement1:RFSettings:FOFFset?Read Analyzer Frequency Offset. Reads the analyzer frequency offset in Hz.None
CONFigure:GPRF:MEASurement1:POWer:MODE <Mode>Set Power Measurement Mode. Selects the power measurement mode used when list mode is off.Text: POWer,STATistic
CONFigure:GPRF:MEASurement1:POWer:MODE?Read Power Measurement Mode. Reads the selected power measurement mode.None
CONFigure:GPRF:MEASurement1:POWer:REPetition <Repetition>Set Power Repetition. Selects whether the power measurement is stopped after one cycle or repeated continuously.Text: SINGleshot,CONTinuous
CONFigure:GPRF:MEASurement1:POWer:REPetition?Read Power Repetition. Reads the repetition mode of the power measurement.None
CONFigure:GPRF:MEASurement1:POWer:SCOunt <Count>Set Power Statistic Count. Specifies the number of measurement intervals per measurement cycle (1 to 100000).Number
CONFigure:GPRF:MEASurement1:POWer:SCOunt?Read Power Statistic Count. Reads the statistic count of the power measurement.None
CONFigure:GPRF:MEASurement1:POWer:MLENgth <Seconds>Set Power Measurement Length. Sets the evaluation interval used to calculate one set of current power results (RMS, minimum, maximum) in seconds.Number
CONFigure:GPRF:MEASurement1:POWer:MLENgth?Read Power Measurement Length. Reads the power measurement evaluation interval in seconds.None
CONFigure:GPRF:MEASurement1:POWer:SLENgth <Seconds>Set Power Step Length. Sets the time between the beginnings of two consecutive measurement lengths in seconds.Number
CONFigure:GPRF:MEASurement1:POWer:SLENgth?Read Power Step Length. Reads the step length of the power measurement in seconds.None
CONFigure:GPRF:MEASurement1:POWer:TOUT <Seconds>Set Power Timeout. Defines a timeout for the power measurement in seconds; 0 s means an infinite timeout.Number
CONFigure:GPRF:MEASurement1:POWer:TOUT?Read Power Timeout. Reads the power measurement timeout in seconds.None
CONFigure:GPRF:MEASurement1:POWer:PDEFset <Name>Set Power Predefined Set. Loads a predefined parameter set for the power measurement.Text
CONFigure:GPRF:MEASurement1:POWer:PDEFset?Read Power Predefined Set. Reads the name of the loaded predefined power parameter set.None
CONFigure:GPRF:MEASurement1:DISPlay <Tab>Set Measurement Display Tab. Selects the measurement tab shown on the instrument display during remote control.Text: POWer,SPECtrum,FFTSanalyzer,IQRecorder,IQVSlot,EPSensor
CONFigure:GPRF:MEASurement1:DISPlay?Read Measurement Display Tab. Reads the measurement tab currently shown on the instrument display.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:FSPan <Span>Set FFT Frequency Span. Configures the frequency span of the FFT spectrum analyzer in Hz.Number: 1250000,2500000,5000000,10000000,20000000,40000000,80000000,160000000
CONFigure:GPRF:MEASurement1:FFTSanalyzer:FSPan?Read FFT Frequency Span. Reads the frequency span of the FFT spectrum analyzer in Hz.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:FFTLength <Length>Set FFT Length. Selects the number of samples recorded per measurement interval of the FFT spectrum analyzer.Number: 1024,2048,4096,8192,16384
CONFigure:GPRF:MEASurement1:FFTSanalyzer:FFTLength?Read FFT Length. Reads the configured FFT length.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:DETector <Detector>Set FFT Detector. Defines how the spectrum diagram is calculated from the frequency domain samples.Text: PEAK,RMS
CONFigure:GPRF:MEASurement1:FFTSanalyzer:DETector?Read FFT Detector. Reads the detector used by the FFT spectrum analyzer.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:AMODe <Mode>Set FFT Averaging Mode. Selects whether the average traces are calculated from linear or logarithmic power values.Text: LINear,LOGarithmic
CONFigure:GPRF:MEASurement1:FFTSanalyzer:AMODe?Read FFT Averaging Mode. Reads the averaging mode of the FFT spectrum analyzer.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:REPetition <Repetition>Set FFT Repetition. Selects whether the FFT measurement is stopped after one cycle or repeated continuously.Text: SINGleshot,CONTinuous
CONFigure:GPRF:MEASurement1:FFTSanalyzer:REPetition?Read FFT Repetition. Reads the repetition mode of the FFT spectrum analyzer.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:SCOunt <Count>Set FFT Statistic Count. Specifies the number of measurement intervals per single shot for the FFT measurement (1 to 1000).Number
CONFigure:GPRF:MEASurement1:FFTSanalyzer:SCOunt?Read FFT Statistic Count. Reads the statistic count of the FFT measurement.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:TOUT <Seconds>Set FFT Timeout. Defines a timeout for the FFT measurement in seconds.Number
CONFigure:GPRF:MEASurement1:FFTSanalyzer:TOUT?Read FFT Timeout. Reads the FFT measurement timeout in seconds.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:MOEXception ONTurn On FFT Measure On Exception. Accepts faulty FFT results instead of rejecting them.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:MOEXception OFFTurn Off FFT Measure On Exception. Rejects faulty FFT results.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:MOEXception?Read FFT Measure On Exception. Reads whether faulty FFT results are accepted or rejected.None
CONFigure:GPRF:MEASurement1:SPECtrum:AMODe <Mode>Set Spectrum Averaging Mode. Defines how the average traces are calculated from the current spectrum results.Text: LINear,LOGarithmic
CONFigure:GPRF:MEASurement1:SPECtrum:AMODe?Read Spectrum Averaging Mode. Reads the averaging mode of the spectrum measurement.None
CONFigure:GPRF:MEASurement1:SPECtrum:REPetition <Repetition>Set Spectrum Repetition. Selects whether the spectrum measurement is stopped after one cycle or repeated continuously.Text: SINGleshot,CONTinuous
CONFigure:GPRF:MEASurement1:SPECtrum:REPetition?Read Spectrum Repetition. Reads the repetition mode of the spectrum measurement.None
CONFigure:GPRF:MEASurement1:SPECtrum:SCOunt <Count>Set Spectrum Statistic Count. Specifies the number of measurement intervals per single shot for the spectrum measurement (1 to 1000).Number
CONFigure:GPRF:MEASurement1:SPECtrum:SCOunt?Read Spectrum Statistic Count. Reads the statistic count of the spectrum measurement.None
CONFigure:GPRF:MEASurement1:SPECtrum:TOUT <Seconds>Set Spectrum Timeout. Defines a timeout for the spectrum measurement in seconds; 0 s means an infinite timeout.Number
CONFigure:GPRF:MEASurement1:SPECtrum:TOUT?Read Spectrum Timeout. Reads the spectrum measurement timeout in seconds.None
CONFigure:WLAN:SIGNaling1:CONNection:STANdard <Standard>Set WLAN Standard. Selects the IEEE 802.11 standard (b, a, g, g OFDM, a/n, g/n, g OFDM/n, ac, ax).Text: BSTD,ASTD,GSTD,GOSTd,ANSTd,GNSTd,GONStd,ACSTd,AXSTd
CONFigure:WLAN:SIGNaling1:CONNection:STANdard?Read WLAN Standard. Reads the selected IEEE 802.11 standard (b, a, g, g OFDM, a/n, g/n, g OFDM/n, ac, ax).None
CONFigure:WLAN:SIGNaling1:CONNection:OMODe <Mode>Set WLAN Operation Mode. Selects the simulated WLAN entity: access point, station or Hotspot 2.0 access point.Text: AP,STATion,HSPot2
CONFigure:WLAN:SIGNaling1:CONNection:OMODe?Read WLAN Operation Mode. Reads the selected simulated WLAN entity: access point, station or Hotspot 2.0 access point.None
CONFigure:WLAN:SIGNaling1:CONNection:SSID <SSID>Set WLAN SSID. Sets the service set identifier (string, up to 32 ASCII characters).Text
CONFigure:WLAN:SIGNaling1:CONNection:SSID?Read WLAN SSID. Reads the service set identifier (string, up to 32 ASCII characters).None
CONFigure:WLAN:SIGNaling1:CONNection:BSSid <BSSID>Set WLAN BSSID. Sets the 48-bit MAC address of the tester WLAN interface (hex, e.g. #H001122334455).Text
CONFigure:WLAN:SIGNaling1:CONNection:BSSid?Read WLAN BSSID. Reads the 48-bit MAC address of the tester WLAN interface (hex, e.g. #H001122334455).None
CONFigure:WLAN:SIGNaling1:CONNection:BEACon <Interval>Set WLAN Beacon Interval. Sets the beacon interval in time units of 1024 us (20 to 16000).Number: 20,16000
CONFigure:WLAN:SIGNaling1:CONNection:BEACon?Read WLAN Beacon Interval. Reads the beacon interval in time units of 1024 us (20 to 16000).None
CONFigure:WLAN:SIGNaling1:CONNection:DPERiod <Period>Set WLAN DTIM Period. Sets the number of beacon intervals between DTIM messages (1 to 10).Number: 1,10
CONFigure:WLAN:SIGNaling1:CONNection:DPERiod?Read WLAN DTIM Period. Reads the number of beacon intervals between DTIM messages (1 to 10).None
CONFigure:WLAN:SIGNaling1:CONNection:SECurity:ENCRyption <Type>Set WLAN Encryption. Sets the encryption type used with WPA/WPA2/WPA3 personal security in AP mode.Text: AES,TKIP,DISabled,GCMP
CONFigure:WLAN:SIGNaling1:CONNection:SECurity:ENCRyption?Read WLAN Encryption. Reads the encryption type used with WPA/WPA2/WPA3 personal security in AP mode.None
CONFigure:WLAN:SIGNaling1:CONNection:SECurity:PASSphrase <Security_Type>, <Passphrase>Set WLAN Security Passphrase. Selects the security mechanism and defines the WPA/WPA2/WPA3 personal passphrase.Text: AUTO,DISabled,OWE,W2ENterprise,W2Personal,W3ENterprise,W3Personal,WENTerprise,WPERsonal; Text
CONFigure:WLAN:SIGNaling1:CONNection:STATion:CMODe <Mode>Set WLAN Station Connection Mode. Selects automatic or manual association behaviour of the simulated station (operation mode Station).Text: ACONnect,MANual
CONFigure:WLAN:SIGNaling1:CONNection:STATion:CMODe?Read WLAN Station Connection Mode. Reads the selection: automatic or manual association behaviour of the simulated station (operation mode Station).None
CONFigure:WLAN:SIGNaling1:CONNection:DSSS ONTurn On WLAN DSSS Support. Allows association of 802.11b devices and non-HT management frames in 802.11ac/ax.None
CONFigure:WLAN:SIGNaling1:CONNection:DSSS OFFTurn Off WLAN DSSS Support. Disables DSSS support in 802.11ac/ax operation.None
CONFigure:WLAN:SIGNaling1:RFSettings:BAND <Band>Set WLAN Frequency Band. Selects the operating band: sub-6 GHz or 6 GHz.Text: BS6Ghz,B6GHz
CONFigure:WLAN:SIGNaling1:RFSettings:BAND?Read WLAN Frequency Band. Reads the selected operating band: sub-6 GHz or 6 GHz.None
CONFigure:WLAN:SIGNaling1:RFSettings:CHANnel <Channel>Set WLAN Channel. Sets the WLAN RF channel number (1 to 196).Number: 1,196
CONFigure:WLAN:SIGNaling1:RFSettings:CHANnel?Read WLAN Channel. Reads the WLAN RF channel number (1 to 196).None
CONFigure:WLAN:SIGNaling1:RFSettings:FREQuency <Frequency>Set WLAN Frequency. Sets the center frequency of the generated WLAN signal and of the analyzer in Hz (70 MHz to 6 GHz).Number
CONFigure:WLAN:SIGNaling1:RFSettings:FREQuency?Read WLAN Frequency. Reads the center frequency of the generated WLAN signal and of the analyzer in Hz (70 MHz to 6 GHz).None
CONFigure:WLAN:SIGNaling1:RFSettings:OCWidth <Bandwidth>Set WLAN Channel Bandwidth. Sets the operating channel bandwidth.Text: BW20,BW40,BW80,BW160
CONFigure:WLAN:SIGNaling1:RFSettings:OCWidth?Read WLAN Channel Bandwidth. Reads the operating channel bandwidth.None
CONFigure:WLAN:SIGNaling1:RFSettings:BOPower <Power>Set WLAN Burst Output Power. Sets the burst power of the transmitted WLAN signal in dBm.Number
CONFigure:WLAN:SIGNaling1:RFSettings:BOPower?Read WLAN Burst Output Power. Reads the burst power of the transmitted WLAN signal in dBm.None
CONFigure:WLAN:SIGNaling1:RFSettings:EATTenuation:INPut <Atten>Set WLAN Input External Attenuation. Sets the external attenuation at the RF input in dB.Number
CONFigure:WLAN:SIGNaling1:RFSettings:EATTenuation:INPut?Read WLAN Input External Attenuation. Reads the external attenuation at the RF input in dB.None
CONFigure:WLAN:SIGNaling1:RFSettings:EPEPower <Power>Set WLAN Expected Peak Envelope Power. Sets the expected peak envelope power of the DUT signal in dBm.Number
CONFigure:WLAN:SIGNaling1:RFSettings:EPEPower?Read WLAN Expected Peak Envelope Power. Reads the expected peak envelope power of the DUT signal in dBm.None
CONFigure:WLAN:SIGNaling1:PER:PACKets <Packets>Set WLAN PER Packets. Sets the number of user data MAC packets transmitted to the DUT for the PER measurement.Number: 1,1000000
CONFigure:WLAN:SIGNaling1:PER:PACKets?Read WLAN PER Packets. Reads the number of user data MAC packets transmitted to the DUT for the PER measurement.None
CONFigure:WLAN:SIGNaling1:PER:REPetition <Repetition>Set WLAN PER Repetition. Sets the repetition mode of the PER measurement.Text: SINGleshot,CONTinuous
CONFigure:WLAN:SIGNaling1:PER:REPetition?Read WLAN PER Repetition. Reads the repetition mode of the PER measurement.None
CONFigure:WLAN:SIGNaling1:FADing:AWGN:ENABle ONTurn On WLAN Fading AWGN. Enables AWGN insertion via the fading module.None
CONFigure:WLAN:SIGNaling1:FADing:AWGN:ENABle OFFTurn Off WLAN Fading AWGN. Disables AWGN insertion via the fading module.None
CONFigure:WLAN:SIGNaling1:FADing:AWGN:SNRatio <SNR>Set WLAN Fading AWGN SNR. Sets the signal to noise ratio of the inserted AWGN in dB (0 to 40).Number: 0,40
CONFigure:WLAN:SIGNaling1:FADing:AWGN:SNRatio?Read WLAN Fading AWGN SNR. Reads the signal to noise ratio of the inserted AWGN in dB (0 to 40).None
CONFigure:WLAN:MEASurement1:ISIGnal:STANdard <Standard>Set WLAN Meas Standard. Selects the IEEE 802.11 standard of the measured signal (b/g DSSS, a/g OFDM, n, ac, ax, p).Text: DSSS,LOFDm,HTOFdm,VHTofdm,HEOFdm,POFDm
CONFigure:WLAN:MEASurement1:ISIGnal:STANdard?Read WLAN Meas Standard. Reads the selected IEEE 802.11 standard of the measured signal (b/g DSSS, a/g OFDM, n, ac, ax, p).None
CONFigure:WLAN:MEASurement1:ISIGnal:BWIDth <Bandwidth>Set WLAN Meas Bandwidth. Selects the channel bandwidth of the measured signal.Text: BW05mhz,BW10mhz,BW20mhz,BW40mhz,BW80mhz,BW16mhz,BW88mhz
CONFigure:WLAN:MEASurement1:ISIGnal:BWIDth?Read WLAN Meas Bandwidth. Reads the selected channel bandwidth of the measured signal.None
CONFigure:WLAN:MEASurement1:RFSettings:FREQuency <Frequency>Set WLAN Meas Frequency. Sets the analyzer center frequency in Hz (center of the received WLAN channel).Number
CONFigure:WLAN:MEASurement1:RFSettings:FREQuency?Read WLAN Meas Frequency. Reads the analyzer center frequency in Hz (center of the received WLAN channel).None
CONFigure:WLAN:MEASurement1:RFSettings:FREQuency:BAND <Band>Set WLAN Meas Frequency Band. Selects the WLAN frequency band.Text: B24Ghz,B4GHz,B5GHz,B6GHz
CONFigure:WLAN:MEASurement1:RFSettings:FREQuency:BAND?Read WLAN Meas Frequency Band. Reads the selected WLAN frequency band.None
CONFigure:WLAN:MEASurement1:RFSettings:ENPower <Power>Set WLAN Meas Expected Power. Sets the expected nominal power of the measured RF signal in dBm.Number
CONFigure:WLAN:MEASurement1:RFSettings:ENPower?Read WLAN Meas Expected Power. Reads the expected nominal power of the measured RF signal in dBm.None
CONFigure:WLAN:MEASurement1:RFSettings:EATTenuation <Atten>Set WLAN Meas External Attenuation. Sets the external attenuation at the RF input in dB (-50 to 90).Number: -50,90
CONFigure:WLAN:MEASurement1:RFSettings:EATTenuation?Read WLAN Meas External Attenuation. Reads the external attenuation at the RF input in dB (-50 to 90).None
CONFigure:WLAN:MEASurement1:RFSettings:UMARgin <Margin>Set WLAN Meas User Margin. Sets the margin added to the expected nominal power to determine the reference power in dB.Number
CONFigure:WLAN:MEASurement1:RFSettings:UMARgin?Read WLAN Meas User Margin. Reads the margin added to the expected nominal power to determine the reference power in dB.None
CONFigure:WLAN:MEASurement1:MEValuation:REPetition <Repetition>Set WLAN Meas Repetition. Selects single-shot or continuous WLAN multi-evaluation measurement.Text: SINGleshot,CONTinuous
CONFigure:WLAN:MEASurement1:MEValuation:REPetition?Read WLAN Meas Repetition. Reads the selection: single-shot or continuous WLAN multi-evaluation measurement.None
CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:MODulation <Count>Set WLAN Meas Modulation Count. Sets the statistic count for modulation measurements (1 to 2000).Number: 1,2000
CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:MODulation?Read WLAN Meas Modulation Count. Reads the statistic count for modulation measurements (1 to 2000).None
CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:TSMask <Count>Set WLAN Meas Spectrum Mask Count. Sets the statistic count for the transmit spectrum mask measurement (1 to 1000).Number: 1,1000
CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:TSMask?Read WLAN Meas Spectrum Mask Count. Reads the statistic count for the transmit spectrum mask measurement (1 to 1000).None
CONFigure:WLAN:MEASurement1:MEValuation:TOUT <Seconds>Set WLAN Meas Timeout. Defines a timeout for the WLAN measurement in seconds.Number
CONFigure:WLAN:MEASurement1:MEValuation:TOUT?Read WLAN Meas Timeout. Reads the timeout for the WLAN measurement in seconds.None
CONFigure:WLAN:MEASurement1:MEValuation:SCONdition <Condition>Set WLAN Meas Stop Condition. Defines whether the measurement stops on a limit failure.Text: NONE,SLFail
CONFigure:WLAN:MEASurement1:MEValuation:SCONdition?Read WLAN Meas Stop Condition. Reads whether the measurement stops on a limit failure.None
CONFigure:WLAN:MEASurement1:MEValuation:MOEXception ONTurn On WLAN Meas On Exception. Results identified as faulty are never rejected.None
CONFigure:WLAN:MEASurement1:MEValuation:MOEXception OFFTurn Off WLAN Meas On Exception. Faulty results are rejected.None
CONFigure:BLUetooth:SIGNaling1:STANdard <Standard>Set BT Standard. Selects classic (BR/EDR) or low energy (LE) signaling.Text: CLASsic,LESignaling
CONFigure:BLUetooth:SIGNaling1:STANdard?Read BT Standard. Reads the selection: classic (BR/EDR) or low energy (LE) signaling.None
CONFigure:BLUetooth:SIGNaling1:OPMode <Mode>Set BT Operating Mode. Selects the operating mode: connection test, RF test mode, echo, profiles, audio or LE test mode.Text: CNTest,RFTest,ECMode,PROFiles,AUDio,LETMode
CONFigure:BLUetooth:SIGNaling1:OPMode?Read BT Operating Mode. Reads the selected operating mode: connection test, RF test mode, echo, profiles, audio or LE test mode.None
CONFigure:BLUetooth:SIGNaling1:CONNection:BTYPe <Type>Set BT Burst Type. Selects the burst type of the connection: basic rate, enhanced data rate or low energy.Text: BR,EDR,LE
CONFigure:BLUetooth:SIGNaling1:CONNection:BTYPe?Read BT Burst Type. Reads the selected burst type of the connection: basic rate, enhanced data rate or low energy.None
CONFigure:BLUetooth:SIGNaling1:TMODe <Mode>Set BT Test Mode. Selects the BR/EDR test mode entered by the EUT: loopback or TX test.Text: LOOPback,TXTest
CONFigure:BLUetooth:SIGNaling1:TMODe?Read BT Test Mode. Reads the selected BR/EDR test mode entered by the EUT: loopback or TX test.None
CONFigure:BLUetooth:SIGNaling1:CONNection:BDADdress:EUT <Address>Set BT EUT Address. Sets the BD_ADDR of the default device to page (12 hex digits, e.g. #H0123456789AB).Text
CONFigure:BLUetooth:SIGNaling1:CONNection:BDADdress:EUT?Read BT EUT Address. Reads the BD_ADDR of the default device to page (12 hex digits, e.g. #H0123456789AB).None
CONFigure:BLUetooth:SIGNaling1:CONNection:BDADdress:CMW <Address>Set BT Tester Address. Sets the BD_ADDR of the tester (12 hex digits).Text
CONFigure:BLUetooth:SIGNaling1:CONNection:BDADdress:CMW?Read BT Tester Address. Reads the BD_ADDR of the tester (12 hex digits).None
CONFigure:BLUetooth:SIGNaling1:CONNection:PAGing:PTARget <Index>Set BT Paging Target. Selects the device to page from the inquiry target catalog (0 = default device).Number
CONFigure:BLUetooth:SIGNaling1:CONNection:PAGing:PTARget?Read BT Paging Target. Reads the selected device to page from the inquiry target catalog (0 = default device).None
CONFigure:BLUetooth:SIGNaling1:CONNection:INQuiry:NOResponses <Number>Set BT Inquiry Max Responses. Sets the maximum number of inquiry responses (0 = unlimited, max 12).Number: 0,12
CONFigure:BLUetooth:SIGNaling1:CONNection:INQuiry:NOResponses?Read BT Inquiry Max Responses. Reads the maximum number of inquiry responses (0 = unlimited, max 12).None
CONFigure:BLUetooth:SIGNaling1:CONNection:PACKets:PTYPe:BRATe <Type>Set BT BR Packet Type. Sets the basic rate packet type.Text: DH1,DH3,DH5
CONFigure:BLUetooth:SIGNaling1:CONNection:PACKets:PTYPe:BRATe?Read BT BR Packet Type. Reads the basic rate packet type.None
CONFigure:BLUetooth:SIGNaling1:CONNection:PACKets:PTYPe:EDRate <Type>Set BT EDR Packet Type. Sets the enhanced data rate packet type.Text: E21P,E23P,E25P,E31P,E33P,E35P
CONFigure:BLUetooth:SIGNaling1:CONNection:PACKets:PTYPe:EDRate?Read BT EDR Packet Type. Reads the enhanced data rate packet type.None
CONFigure:BLUetooth:SIGNaling1:CONNection:PACKets:PATTern:BRATe <Pattern>Set BT BR Payload Pattern. Sets the payload bit pattern for basic rate test mode.Text: ALL0,ALL1,P11,P44,PRBS9,ALT
CONFigure:BLUetooth:SIGNaling1:CONNection:PACKets:PATTern:BRATe?Read BT BR Payload Pattern. Reads the payload bit pattern for basic rate test mode.None
CONFigure:BLUetooth:SIGNaling1:RFSettings:LEVel <Level>Set BT TX Level. Sets the absolute TX level of the tester signal in dBm.Number
CONFigure:BLUetooth:SIGNaling1:RFSettings:LEVel?Read BT TX Level. Reads the absolute TX level of the tester signal in dBm.None
CONFigure:BLUetooth:SIGNaling1:RFSettings:ENPower <Power>Set BT Expected Power. Sets the expected nominal power of the EUT signal in dBm.Number
CONFigure:BLUetooth:SIGNaling1:RFSettings:ENPower?Read BT Expected Power. Reads the expected nominal power of the EUT signal in dBm.None
CONFigure:BLUetooth:SIGNaling1:RFSettings:UMARgin <Margin>Set BT User Margin. Sets the user margin added to the expected nominal power in dB.Number
CONFigure:BLUetooth:SIGNaling1:RFSettings:UMARgin?Read BT User Margin. Reads the user margin added to the expected nominal power in dB.None
CONFigure:BLUetooth:SIGNaling1:RFSettings:EATTenuation:INPut <Atten>Set BT Input External Attenuation. Sets the external attenuation at the input connector in dB.Number: -50,90
CONFigure:BLUetooth:SIGNaling1:RFSettings:EATTenuation:INPut?Read BT Input External Attenuation. Reads the external attenuation at the input connector in dB.None
CONFigure:BLUetooth:SIGNaling1:RFSettings:EATTenuation:OUTPut <Atten>Set BT Output External Attenuation. Sets the external attenuation at the output connector in dB.Number: -50,90
CONFigure:BLUetooth:SIGNaling1:RFSettings:EATTenuation:OUTPut?Read BT Output External Attenuation. Reads the external attenuation at the output connector in dB.None
CONFigure:BLUetooth:SIGNaling1:RFSettings:HOPPing ONTurn On BT Hopping. Enables frequency hopping.None
CONFigure:BLUetooth:SIGNaling1:RFSettings:HOPPing OFFTurn Off BT Hopping. Disables frequency hopping.None
CONFigure:BLUetooth:SIGNaling1:RFSettings:CHANnel:TMODe <Channel>Set BT LE Test Mode Channel. Sets the RF channel for LE test mode (0 to 39).Number: 0,39
CONFigure:BLUetooth:SIGNaling1:RFSettings:CHANnel:TMODe?Read BT LE Test Mode Channel. Reads the RF channel for LE test mode (0 to 39).None
CONFigure:BLUetooth:SIGNaling1:RXQuality:PACKets:BEDR <Packets>Set BT RX Quality Packets. Defines the number of data packets measured per BER statistics cycle.Number: 1,400000
CONFigure:BLUetooth:SIGNaling1:RXQuality:PACKets:BEDR?Read BT RX Quality Packets. Reads the number of data packets measured per BER statistics cycle.None
CONFigure:BLUetooth:SIGNaling1:RXQuality:REPetition <Repetition>Set BT RX Quality Repetition. Selects single-shot or continuous RX quality measurement.Text: SINGleshot,CONTinuous
CONFigure:BLUetooth:SIGNaling1:RXQuality:REPetition?Read BT RX Quality Repetition. Reads the selection: single-shot or continuous RX quality measurement.None
CONFigure:BLUetooth:SIGNaling1:RXQuality:TOUT <Seconds>Set BT RX Quality Timeout. Defines a timeout for the RX quality measurement in seconds.Number
CONFigure:BLUetooth:SIGNaling1:RXQuality:TOUT?Read BT RX Quality Timeout. Reads the timeout for the RX quality measurement in seconds.None
CONFigure:BASE:FDCorrection:CTABle:CREate <Table_Name>, <Freq_Loss_Pairs>Create Correction Table. Creates a frequency-dependent attenuation table; pairs are <Frequency Hz>, <Correction dB> (e.g. 1E9, 0.5, 2E9, 0.7).Text; Text
CONFigure:BASE:FDCorrection:CTABle:DELete <Table_Name>Delete Correction Table. Deletes the named correction table.Text
CONFigure:BASE:FDCorrection:CTABle:CATalog?Read Correction Table Catalog. Returns the names of all existing correction tables.None
CONFigure:FDCorrection:ACTivate <Connector>, <Table_Name>, <Direction>Activate Correction Table. Activates a correction table for an RF connector in direction RXTX, RX or TX.Text: RF1C,RF1O,RF2C,RF3C,RF3O,RF4C; Text; Text: RXTX,RX,TX
CONFigure:FDCorrection:DEACtivate <Connector>Deactivate Correction Table. Deactivates all correction tables of an RF connector.Text: RF1C,RF1O,RF2C,RF3C,RF3O,RF4C

Source (SOURce) (40)

CommandWhat it doesArguments
SOURce:GPRF:GENerator1:STATe ONTurn On Generator. Turns the GPRF RF generator on.None
SOURce:GPRF:GENerator1:STATe OFFTurn Off Generator. Turns the GPRF RF generator off.None
SOURce:GPRF:GENerator1:STATe?Read Generator State. Reads the generator state (OFF / PENDing / ON / RDY).None
SOURce:GPRF:GENerator1:STATe:ALL?Read Generator State All. Reads detailed generator state information including the main state and the synchronization state.None
SOURce:GPRF:GENerator1:BBMode <Mode>Set Generator Baseband Mode. Selects the baseband mode of the generator signal: unmodulated CW, dual tone, or ARB waveform playback.Text: CW,DTONe,ARB
SOURce:GPRF:GENerator1:BBMode?Read Generator Baseband Mode. Reads the currently selected generator baseband mode.None
SOURce:GPRF:GENerator1:RFSettings:FREQuency <Freq>Set Generator Frequency. Sets the frequency of the unmodulated RF carrier in Hz (70 MHz to 6 GHz depending on installed options).Number
SOURce:GPRF:GENerator1:RFSettings:FREQuency?Read Generator Frequency. Reads the RF generator carrier frequency in Hz.None
SOURce:GPRF:GENerator1:RFSettings:LEVel <Level>Set Generator Level. Sets the base RMS level of the RF generator in dBm.Number
SOURce:GPRF:GENerator1:RFSettings:LEVel?Read Generator Level. Reads the base RMS output level of the RF generator in dBm.None
SOURce:GPRF:GENerator1:RFSettings:EATTenuation <Atten>Set Generator External Attenuation. Sets the external attenuation (or gain, if negative) at the RF output connector in dB (-50 dB to 90 dB).Number
SOURce:GPRF:GENerator1:RFSettings:EATTenuation?Read Generator External Attenuation. Reads the external attenuation configured for the RF output path in dB.None
SOURce:GPRF:GENerator1:RFSettings:DGAin <Gain>Set Generator Digital Gain. Sets the digital gain of the RF generator in dB.Number
SOURce:GPRF:GENerator1:RFSettings:DGAin?Read Generator Digital Gain. Reads the digital gain of the RF generator in dB.None
SOURce:GPRF:GENerator1:RFSettings:PEPower?Read Generator Peak Envelope Power. Reads the peak envelope power of the generated signal in dBm.None
SOURce:GPRF:GENerator1:ARB:FILE <Filename>Select ARB Waveform File. Selects the ARB waveform file (.wv) to be played back in ARB baseband mode.Text
SOURce:GPRF:GENerator1:ARB:FILE?Read ARB Waveform File. Reads the name of the currently loaded ARB waveform file.None
SOURce:GPRF:GENerator1:ARB:FILE:DATE?Read ARB File Date. Reads the creation date stored in the loaded ARB waveform file.None
SOURce:GPRF:GENerator1:ARB:FILE:VERSion?Read ARB File Version. Reads the version of the loaded ARB waveform file.None
SOURce:GPRF:GENerator1:ARB:FILE:OPTion?Read ARB File Options. Reads the list of instrument options required to play back the loaded ARB waveform file.None
SOURce:GPRF:GENerator1:ARB:REPetition <Repetition>Set ARB Repetition. Defines whether the ARB waveform file is processed continuously or for a defined number of cycles.Text: CONTinuous,SINGle
SOURce:GPRF:GENerator1:ARB:REPetition?Read ARB Repetition. Reads the ARB repetition mode.None
SOURce:GPRF:GENerator1:ARB:CYCLes <Cycles>Set ARB Cycles. Defines how often the ARB file is processed in single-shot repetition mode (1 to 10000).Number
SOURce:GPRF:GENerator1:ARB:CYCLes?Read ARB Cycles. Reads the configured number of ARB playback cycles.None
SOURce:GPRF:GENerator1:ARB:FOFFset <Freq>Set ARB Frequency Offset. Sets the frequency offset imposed at the baseband during ARB generation in Hz.Number
SOURce:GPRF:GENerator1:ARB:FOFFset?Read ARB Frequency Offset. Reads the ARB baseband frequency offset in Hz.None
SOURce:GPRF:GENerator1:ARB:ASAMples <Samples>Set ARB Additional Samples. Extends the processing time of the waveform file by the specified number of samples.Number
SOURce:GPRF:GENerator1:ARB:ASAMples?Read ARB Additional Samples. Reads the number of additional samples appended to the waveform file.None
SOURce:GPRF:GENerator1:ARB:CRATe?Read ARB Clock Rate. Reads the clock rate of the loaded ARB waveform file in Hz.None
SOURce:GPRF:GENerator1:ARB:POFFset?Read ARB Peak Offset. Reads the peak offset of the loaded ARB waveform file in dB.None
SOURce:GPRF:GENerator1:ARB:LOFFset?Read ARB Level Offset. Reads the level offset (peak to average ratio) of the loaded ARB waveform file in dB.None
SOURce:GPRF:GENerator1:ARB:CRCProtect?Read ARB CRC Protection. Reads whether the loaded ARB waveform file contains a CRC checksum.None
SOURce:GPRF:GENerator1:ARB:STATus?Read ARB Segment Status. Reads the number of the ARB segment currently being processed.None
SOURce:GPRF:GENerator1:ARB:SCOunt?Read ARB Sample Count. Reads the progress of the ARB file processing as elapsed time and sample count.None
SOURce:WLAN:SIGNaling1:STATe ONTurn On WLAN Signaling. Turns the WLAN signaling generator (access point/station) on.None
SOURce:WLAN:SIGNaling1:STATe OFFTurn Off WLAN Signaling. Turns the WLAN signaling generator off.None
SOURce:WLAN:SIGNaling1:STATe?Read WLAN Signaling. Reads the WLAN signaling generator state.None
SOURce:BLUetooth:SIGNaling1:STATe ONTurn On BT Signaling. Switches the Bluetooth signaling application on (standby state).None
SOURce:BLUetooth:SIGNaling1:STATe OFFTurn Off BT Signaling. Switches the Bluetooth signaling application off.None
SOURce:BLUetooth:SIGNaling1:STATe?Read BT Signaling. Reads the Bluetooth signaling main state.None

Fetch (FETCh) (34)

CommandWhat it doesArguments
FETCh:GPRF:MEASurement1:POWer:STATe?Read Power Measurement State. Reads the main state of the power measurement (OFF / RUN / RDY).None
FETCh:GPRF:MEASurement1:POWer:STATe:ALL?Read Power Measurement State All. Reads the detailed power measurement state including the main state and the synchronization state.None
FETCh:GPRF:MEASurement1:POWer:CURRent?Fetch Power Current. Fetches the current power results of all measured segments in dBm without restarting the measurement.None
FETCh:GPRF:MEASurement1:POWer:CURRent:RMS?Fetch Power Current RMS. Fetches the current RMS power results in dBm.None
FETCh:GPRF:MEASurement1:POWer:AVERage?Fetch Power Average. Fetches the average power results of all measured segments in dBm.None
FETCh:GPRF:MEASurement1:POWer:AVERage:RMS?Fetch Power Average RMS. Fetches the average RMS power results in dBm.None
FETCh:GPRF:MEASurement1:POWer:MAXimum:CURRent?Fetch Power Maximum. Fetches the current-maximum power results (one value per measured segment) in dBm.None
FETCh:GPRF:MEASurement1:POWer:MINimum:CURRent?Fetch Power Minimum. Fetches the current-minimum power results (one value per measured segment) in dBm.None
FETCh:GPRF:MEASurement1:POWer:PEAK:MAXimum?Fetch Power Peak Maximum. Fetches the peak maximum power results in dBm.None
FETCh:GPRF:MEASurement1:POWer:PEAK:MINimum?Fetch Power Peak Minimum. Fetches the peak minimum power results in dBm.None
FETCh:GPRF:MEASurement1:POWer:SDEViation?Fetch Power Standard Deviation. Fetches the standard deviation of the power results in dB.None
FETCh:GPRF:MEASurement1:FFTSanalyzer:STATe?Read FFT Measurement State. Reads the main state of the FFT spectrum analyzer measurement.None
FETCh:GPRF:MEASurement1:FFTSanalyzer:POWer:CURRent?Fetch FFT Power Current. Fetches the current FFT spectrum trace as a list of 801 power values in dBm.None
FETCh:GPRF:MEASurement1:FFTSanalyzer:POWer:AVERage?Fetch FFT Power Average. Fetches the average FFT spectrum trace as a list of 801 power values in dBm.None
FETCh:GPRF:MEASurement1:FFTSanalyzer:POWer:MAXimum?Fetch FFT Power Maximum. Fetches the maximum-hold FFT spectrum trace in dBm.None
FETCh:GPRF:MEASurement1:FFTSanalyzer:POWer:MINimum?Fetch FFT Power Minimum. Fetches the minimum-hold FFT spectrum trace in dBm.None
FETCh:GPRF:MEASurement1:SPECtrum:STATe?Read Spectrum Measurement State. Reads the main state of the spectrum measurement.None
FETCh:GPRF:MEASurement1:SPECtrum:RMS:CURRent?Fetch Spectrum RMS Current. Fetches the current RMS spectrum trace in dBm.None
FETCh:GPRF:MEASurement1:SPECtrum:RMS:AVERage?Fetch Spectrum RMS Average. Fetches the average RMS spectrum trace in dBm.None
FETCh:GPRF:MEASurement1:SPECtrum:RMS:MAXimum?Fetch Spectrum RMS Maximum. Fetches the maximum-hold RMS spectrum trace in dBm.None
FETCh:GPRF:MEASurement1:SPECtrum:RMS:MINimum?Fetch Spectrum RMS Minimum. Fetches the minimum-hold RMS spectrum trace in dBm.None
FETCh:WLAN:SIGNaling1:PSWitched:STATe?Read WLAN Connection State. Returns the connection state: IDLE, PROBed, AUTHenticated, ASSociated, DEAuthenticated, DISassociated or CTIMeout.None
FETCh:WLAN:SIGNaling1:PER:STATe?Read WLAN PER State. Returns the WLAN packet error rate measurement state: OFF, RUN or RDY.None
FETCh:WLAN:SIGNaling1:PER?Fetch WLAN PER. Returns all results of the WLAN PER measurement.None
FETCh:WLAN:MEASurement1:MEValuation:STATe?Read WLAN MultiEval State. Returns the WLAN multi-evaluation measurement state: OFF, RUN or RDY.None
FETCh:WLAN:MEASurement1:MEValuation:MODulation:AVERage?Fetch WLAN Modulation Average. Returns the average single-value modulation results (EVM, frequency/clock error, burst power...) for OFDM SISO signals.None
FETCh:WLAN:MEASurement1:MEValuation:MODulation:CURRent?Fetch WLAN Modulation Current. Returns the current single-value modulation results for OFDM SISO signals.None
FETCh:WLAN:MEASurement1:MEValuation:MODulation:DSSS:AVERage?Fetch WLAN DSSS Modulation Average. Returns the average single-value modulation results for DSSS (802.11b) signals.None
FETCh:WLAN:MEASurement1:MEValuation:TSMask:AVERage?Fetch WLAN Spectrum Mask Average. Returns the limit line margins of the transmit spectrum mask (positive = limit exceeded).None
FETCh:WLAN:MEASurement1:MEValuation:SFLatness:AVERage?Fetch WLAN Spectral Flatness Average. Returns the spectrum flatness margin values (positive = limit violated).None
FETCh:WLAN:MEASurement1:MEValuation:PVTime:REDGe:AVERage?Fetch WLAN PvT Rising Edge Average. Returns the rising edge ramp durations of the power vs time measurement.None
FETCh:BLUetooth:SIGNaling1:CONNection:STATe?Read BT Connection State. Returns the BR/EDR signaling state of the tester (e.g. SBY, INQuiring, CONNected, TCONected).None
FETCh:BLUetooth:SIGNaling1:RXQuality:BER:STATe:BEDR?Read BT BER State. Returns the BER measurement state (OFF, RUN, RDY).None
FETCh:BLUetooth:SIGNaling1:RXQuality:BER:BEDR?Fetch BT BER. Returns all results of the signaling BER measurement.None

System (SYSTem) (15)

CommandWhat it doesArguments
SYSTem:BASE:REFerence:FREQuency:SOURce <Source>Set Reference Frequency Source. Selects the internal or an external reference frequency source for the instrument.Text: INTernal,EXTernal
SYSTem:BASE:REFerence:FREQuency:SOURce?Read Reference Frequency Source. Reads the selected reference frequency source.None
SYSTem:BASE:REFerence:FREQuency <Freq>Set External Reference Frequency. Sets the expected external reference frequency in Hz when the external reference source is selected.Number
SYSTem:BASE:REFerence:FREQuency?Read External Reference Frequency. Reads the expected external reference frequency in Hz.None
SYSTem:ERRor:ALL?Read Error Queue. Queries and deletes all entries in the error queue.None
SYSTem:ERRor:COUNt?Read Error Count. Queries the number of entries currently in the error queue.None
SYSTem:RESet:BASEReset Base Settings. Resets the base settings to the default values suitable for remote operation.None
SYSTem:RESet:ALLReset All Settings. Resets the entire instrument including the base settings and all firmware applications.None
SYSTem:PRESet:BASEPreset Base Settings. Presets the base settings to the default values suitable for manual operation.None
SYSTem:PRESet:ALLPreset All Settings. Presets the entire instrument including the base settings and all firmware applications.None
SYSTem:VERSion?Read SCPI Version. Queries the SCPI version number the instrument complies with.None
SYSTem:BASE:OPTion:LIST?Read Option List. Returns the list of installed software/hardware options and firmware applications.None
SYSTem:GENerator:ALL:OFFAll Generators Off. Switches off all running generators.None
SYSTem:MEASurement:ALL:OFFAll Measurements Off. Switches off all running measurements.None
SYSTem:SIGNaling:ALL:OFFAll Signaling Off. Switches off all signaling applications (cells / network emulators).None

ROUT subsystem (10)

CommandWhat it doesArguments
ROUTe:GPRF:GENerator1:SCENario:SALone <Connector>,<Converter>Route Generator Standalone. Selects the RF output connector and TX module used for the generated RF signal.Text: RF1C,RF1O,RF2C,RF3C,RF3O,RF4C; Text: TX1,TX2,TX3,TX4
ROUTe:GPRF:GENerator1:SCENario?Read Generator Scenario. Reads the active routing scenario of the GPRF generator.None
ROUTe:GPRF:MEASurement1:SCENario:SALone <Connector>,<Converter>Route Measurement Standalone. Activates the standalone scenario and selects the RF input connector and RX module for the GPRF measurement.Text: RF1C,RF2C,RF3C,RF4C; Text: RX1,RX2,RX3,RX4
ROUTe:GPRF:MEASurement1:SCENario:CSPath <Master>Route Measurement Combined Path. Activates the combined signal path scenario and selects the controlling signaling application, for example 'LTE Sig1'.Text
ROUTe:GPRF:MEASurement1:SCENario?Read Measurement Scenario. Reads the active routing scenario of the GPRF measurement (SALone or CSPath).None
ROUTe:WLAN:SIGNaling1:SCENario?Read WLAN Signaling Scenario. Returns the active WLAN signaling scenario (STANdard, MIMO2, SCFading, MIMFading).None
ROUTe:WLAN:SIGNaling1?Read WLAN Signaling Routing. Returns the active WLAN test scenario with the used TRX modules and RF connectors.None
ROUTe:WLAN:MEASurement1:SCENario:SALone <Connector>, <Converter>Route WLAN Measurement Standalone. Activates the standalone scenario and selects the RF input connector and RX module for WLAN measurements.Text: RF1C,RF2C,RF3C,RF4C; Text: RX1,RX2,RX3,RX4
ROUTe:WLAN:MEASurement1:SCENario?Read WLAN Measurement Scenario. Returns the active WLAN measurement scenario.None
ROUTe:BLUetooth:SIGNaling1:SCENario:OTRX?Read BT Signaling Routing. Returns the RF connectors and converters of the one-TX/one-RX Bluetooth scenario.None

Sense (SENSe) (9)

CommandWhat it doesArguments
SENSe:WLAN:SIGNaling1:STA1:UECapability:MAC:ADDRess?Read WLAN DUT MAC Address. Returns the MAC address of the associated DUT (station 1).None
SENSe:WLAN:SIGNaling1:STA1:UESinfo:RXBPower?Read WLAN DUT Burst Power. Returns the average power of the last burst received from the DUT in dBm.None
SENSe:WLAN:SIGNaling1:STA1:UESinfo:DRATe?Read WLAN DUT Data Rate. Returns data rate information of the DUT signal.None
SENSe:WLAN:SIGNaling1:UESinfo:APSSid?Read WLAN Associated AP SSID. Returns the SSID of the associated access point (operation mode Station).None
SENSe:BLUetooth:SIGNaling1:EUT:INFormation:NAME?Read BT EUT Name. Returns the name of the connected Bluetooth device.None
SENSe:BLUetooth:SIGNaling1:EUT:INFormation:BDADdress?Read BT Connected Device Address. Returns the BD_ADDR of the connected Bluetooth device.None
SENSe:BLUetooth:SIGNaling1:EUT:INFormation:VERSion?Read BT EUT Version. Returns the LMP version information of the connected device.None
SENSe:BASE:REFerence:FREQuency:LOCKed?Read Reference Locked. Queries whether the instrument is locked to the selected reference frequency.None
SENSe:BASE:TEMPerature:OPERating:INTernal?Read Internal Temperature. Queries the average internal temperature measured at the RF modules in degrees C.None

Initiate (INITiate) (6)

CommandWhat it doesArguments
INITiate:GPRF:MEASurement1:POWerStart Power Measurement. Starts or restarts the GPRF power measurement and puts it into the RUN state.None
INITiate:GPRF:MEASurement1:FFTSanalyzerStart FFT Measurement. Starts or restarts the FFT spectrum analyzer measurement.None
INITiate:GPRF:MEASurement1:SPECtrumStart Spectrum Measurement. Starts or restarts the spectrum measurement.None
INITiate:WLAN:SIGNaling1:PERStart WLAN PER. Starts or restarts the WLAN packet error rate measurement (state RUN).None
INITiate:WLAN:MEASurement1:MEValuationStart WLAN MultiEval. Starts or restarts the WLAN multi-evaluation measurement (state RUN).None
INITiate:BLUetooth:SIGNaling1:RXQuality:BER:BEDRStart BT BER. Starts the BR/EDR bit error rate measurement.None

Run control (6)

CommandWhat it doesArguments
STOP:GPRF:MEASurement1:POWerStop Power Measurement. Halts the power measurement and puts it into the RDY state while keeping the results.None
STOP:GPRF:MEASurement1:FFTSanalyzerStop FFT Measurement. Halts the FFT measurement and keeps the results.None
STOP:GPRF:MEASurement1:SPECtrumStop Spectrum Measurement. Halts the spectrum measurement and keeps the results.None
STOP:WLAN:SIGNaling1:PERStop WLAN PER. Halts the WLAN packet error rate measurement; results are kept (state RDY).None
STOP:WLAN:MEASurement1:MEValuationStop WLAN MultiEval. Halts the WLAN multi-evaluation measurement; results are kept (state RDY).None
STOP:BLUetooth:SIGNaling1:RXQuality:BER:BEDRStop BT BER. Stops the BR/EDR bit error rate measurement.None

Abort (6)

CommandWhat it doesArguments
ABORt:GPRF:MEASurement1:POWerAbort Power Measurement. Halts the power measurement and puts it into the OFF state; all results are set to NAV.None
ABORt:GPRF:MEASurement1:FFTSanalyzerAbort FFT Measurement. Halts the FFT measurement and clears all results.None
ABORt:GPRF:MEASurement1:SPECtrumAbort Spectrum Measurement. Halts the spectrum measurement and clears all results.None
ABORt:WLAN:SIGNaling1:PERAbort WLAN PER. Aborts the WLAN packet error rate measurement and releases resources (state OFF).None
ABORt:WLAN:MEASurement1:MEValuationAbort WLAN MultiEval. Aborts the WLAN multi-evaluation measurement and releases resources (state OFF).None
ABORt:BLUetooth:SIGNaling1:RXQuality:BER:BEDRAbort BT BER. Aborts the BR/EDR bit error rate measurement.None

Read (READ) (6)

CommandWhat it doesArguments
READ:GPRF:MEASurement1:POWer:CURRent?Read Power Current. Starts the measurement and returns the current power results of all measured segments in dBm.None
READ:GPRF:MEASurement1:POWer:CURRent:RMS?Read Power Current RMS. Starts the measurement and returns the current RMS power results in dBm.None
READ:GPRF:MEASurement1:POWer:AVERage?Read Power Average. Starts the measurement and returns the average power results of all measured segments in dBm.None
READ:GPRF:MEASurement1:POWer:SDEViation?Read Power Standard Deviation. Starts the measurement and returns the standard deviation of the power results in dB.None
READ:GPRF:MEASurement1:FFTSanalyzer:POWer:AVERage?Read FFT Power Average. Starts the measurement and returns the average FFT spectrum trace in dBm.None
READ:WLAN:SIGNaling1:PER?Read WLAN PER. Starts a single-shot PER measurement and returns the results.None

CALL subsystem (4)

CommandWhat it doesArguments
CALL:WLAN:SIGNaling1:ACTion:STATion:CONNectWLAN Station Connect. Initiates association to the AP under test (operation mode Station, connection mode Manual).None
CALL:WLAN:SIGNaling1:ACTion:STATion:REConnectWLAN Station Reconnect. Re-initiates association to the AP under test (operation mode Station).None
CALL:WLAN:SIGNaling1:STA1:ACTion:DISConnectWLAN Disconnect DUT. Disassociates and deauthenticates the DUT (station 1) by sending a deauthentication frame.None
CALL:BLUetooth:SIGNaling1:CONNection:ACTion <Action>BT Connection Action. Requests a BR/EDR signaling action (e.g. INQuire, SINQuiry, CONNect, TMConnect, DETach).Text: INQuire,SINQuiry,CONNect,TMConnect,SCONnecting,DETach,EMConnect,AUDConnect

Calculate (CALCulate) (1)

CommandWhat it doesArguments
CALCulate:GPRF:MEASurement1:POWer:AVERage?Calculate Power Average Limits. Returns the limit check results for the average power instead of the measured values.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (11)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the current sub-instrument to its default state.None
*CLSClear Status. Clears the status byte, event registers and the output buffer.None
*ESR?Read Event Status Register. Returns the contents of the standard event status register (0 to 255) and clears it.None
*STB?Read Status Byte. Returns the contents of the status byte in decimal form.None
*OPCSet Operation Complete Bit. Sets bit 0 of the event status register when all preceding commands are complete.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete before continuing.None
*SAV <Memory>Save State. Stores the current instrument settings in intermediate memory 0 to 99.Number: 0,99
*RCL <Memory>Recall State. Recalls instrument settings from intermediate memory 0 to 99.Number: 0,99
*TRGTrigger Bus. Generates a software (bus) trigger event.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Rohde & Schwarz's programming documentation for the CMW270 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Rohde & Schwarz's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Rohde & Schwarz CMW270 support SCPI remote control?

Yes. The Rohde & Schwarz CMW270 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 318 SCPI commands for it: 167 queries that read values or state, and 151 settings and actions.

How do I control the Rohde & Schwarz CMW270 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, SOURce:GPRF:GENerator1:STATe ON and CONFigure:GPRF:MEASurement1:RFSettings:FREQuency?.

Which command reads a value from the Rohde & Schwarz CMW270?

CONFigure:GPRF:MEASurement1:RFSettings:FREQuency? (read analyzer frequency). Reads the center frequency of the RF analyzer in Hz. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Rohde & Schwarz CMW270 without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Rohde & Schwarz CMW270 through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.