Radio Test Set · SCPI command reference

Rohde & Schwarz CMW100 SCPI commands

The Rohde & Schwarz CMW100 radio test set is controlled remotely with SCPI commands. TestFlow's instrument library holds 305 commands for it, 160 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the CMW100 on a real bench.

Commands
305
Queries
160
Subsystems
15
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Rohde & Schwarz CMW100 and writes the report from the measured results.

Get started

Control the Rohde & Schwarz CMW100 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Rohde & Schwarz CMW100's VISA address

# Paste the address of your Rohde & Schwarz CMW100 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("SOURce:GPRF:GENerator1:STATe ON")  # Turn On Generator
print(inst.query("CONFigure:GPRF:MEASurement1:RFSettings:FREQuency?"))  # Read Analyzer Frequency

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Rohde & Schwarz CMW100 and writes the report from the measured results.

Get started

Run a CMW100 test without writing code

Describe the test in a sentence, for example “turn on generator on the CMW100, then read analyzer frequency and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

305 commands in 15 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Configure (CONFigure) (157)

CommandWhat it doesArguments
CONFigure:GPRF:GENerator1:CMWS:USAGe:TX <Port>, ONEnable Generator Port. Activates an individual RF output port of the connector bench for the generated signal.Text: R11,R12,R13,R14,R15,R16,R17,R18
CONFigure:GPRF:GENerator1:CMWS:USAGe:TX <Port>, OFFDisable Generator Port. Deactivates an individual RF output port of the connector bench.Text: R11,R12,R13,R14,R15,R16,R17,R18
CONFigure:GPRF:GENerator1:CMWS:USAGe:TX? <Port>Read Generator Port Usage. Queries whether an individual RF output port is active.Text: R11,R12,R13,R14,R15,R16,R17,R18
CONFigure:GPRF:MEASurement1:RFSettings:FREQuency <Freq>Set Analyzer Frequency. Sets the center frequency of the RF analyzer in Hz.Number
CONFigure:GPRF:MEASurement1:RFSettings:FREQuency?Read Analyzer Frequency. Reads the center frequency of the RF analyzer in Hz.None
CONFigure:GPRF:MEASurement1:RFSettings:ENPower <Power>Set Analyzer Expected Power. Sets the expected nominal power of the measured RF signal in dBm.Number
CONFigure:GPRF:MEASurement1:RFSettings:ENPower?Read Analyzer Expected Power. Reads the expected nominal power of the measured RF signal in dBm.None
CONFigure:GPRF:MEASurement1:RFSettings:EATTenuation <Atten>Set Analyzer External Attenuation. Sets the external attenuation (or gain, if negative) at the RF input connector in dB (-50 dB to 90 dB).Number
CONFigure:GPRF:MEASurement1:RFSettings:EATTenuation?Read Analyzer External Attenuation. Reads the external attenuation configured for the RF input path in dB.None
CONFigure:GPRF:MEASurement1:RFSettings:UMARgin <Margin>Set Analyzer User Margin. Sets the margin added to the expected nominal power to determine the reference power in dB.Number
CONFigure:GPRF:MEASurement1:RFSettings:UMARgin?Read Analyzer User Margin. Reads the user margin used to determine the reference power in dB.None
CONFigure:GPRF:MEASurement1:RFSettings:MLOFfset <Offset>Set Analyzer Mixer Level Offset. Varies the input level of the mixer in the analyzer path in dB (-10 dB to 16 dB).Number
CONFigure:GPRF:MEASurement1:RFSettings:MLOFfset?Read Analyzer Mixer Level Offset. Reads the mixer level offset of the analyzer path in dB.None
CONFigure:GPRF:MEASurement1:RFSettings:FOFFset <Offset>Set Analyzer Frequency Offset. Sets a positive or negative frequency offset added to the analyzer center frequency in Hz (-100 kHz to 100 kHz).Number
CONFigure:GPRF:MEASurement1:RFSettings:FOFFset?Read Analyzer Frequency Offset. Reads the analyzer frequency offset in Hz.None
CONFigure:GPRF:MEASurement1:POWer:MODE <Mode>Set Power Measurement Mode. Selects the power measurement mode used when list mode is off.Text: POWer,STATistic
CONFigure:GPRF:MEASurement1:POWer:MODE?Read Power Measurement Mode. Reads the selected power measurement mode.None
CONFigure:GPRF:MEASurement1:POWer:REPetition <Repetition>Set Power Repetition. Selects whether the power measurement is stopped after one cycle or repeated continuously.Text: SINGleshot,CONTinuous
CONFigure:GPRF:MEASurement1:POWer:REPetition?Read Power Repetition. Reads the repetition mode of the power measurement.None
CONFigure:GPRF:MEASurement1:POWer:SCOunt <Count>Set Power Statistic Count. Specifies the number of measurement intervals per measurement cycle (1 to 100000).Number
CONFigure:GPRF:MEASurement1:POWer:SCOunt?Read Power Statistic Count. Reads the statistic count of the power measurement.None
CONFigure:GPRF:MEASurement1:POWer:MLENgth <Seconds>Set Power Measurement Length. Sets the evaluation interval used to calculate one set of current power results (RMS, minimum, maximum) in seconds.Number
CONFigure:GPRF:MEASurement1:POWer:MLENgth?Read Power Measurement Length. Reads the power measurement evaluation interval in seconds.None
CONFigure:GPRF:MEASurement1:POWer:SLENgth <Seconds>Set Power Step Length. Sets the time between the beginnings of two consecutive measurement lengths in seconds.Number
CONFigure:GPRF:MEASurement1:POWer:SLENgth?Read Power Step Length. Reads the step length of the power measurement in seconds.None
CONFigure:GPRF:MEASurement1:POWer:TOUT <Seconds>Set Power Timeout. Defines a timeout for the power measurement in seconds; 0 s means an infinite timeout.Number
CONFigure:GPRF:MEASurement1:POWer:TOUT?Read Power Timeout. Reads the power measurement timeout in seconds.None
CONFigure:GPRF:MEASurement1:POWer:PDEFset <Name>Set Power Predefined Set. Loads a predefined parameter set for the power measurement.Text
CONFigure:GPRF:MEASurement1:POWer:PDEFset?Read Power Predefined Set. Reads the name of the loaded predefined power parameter set.None
CONFigure:GPRF:MEASurement1:DISPlay <Tab>Set Measurement Display Tab. Selects the measurement tab shown on the instrument display during remote control.Text: POWer,SPECtrum,FFTSanalyzer,IQRecorder,IQVSlot,EPSensor
CONFigure:GPRF:MEASurement1:DISPlay?Read Measurement Display Tab. Reads the measurement tab currently shown on the instrument display.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:FSPan <Span>Set FFT Frequency Span. Configures the frequency span of the FFT spectrum analyzer in Hz.Number: 1250000,2500000,5000000,10000000,20000000,40000000,80000000,160000000
CONFigure:GPRF:MEASurement1:FFTSanalyzer:FSPan?Read FFT Frequency Span. Reads the frequency span of the FFT spectrum analyzer in Hz.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:FFTLength <Length>Set FFT Length. Selects the number of samples recorded per measurement interval of the FFT spectrum analyzer.Number: 1024,2048,4096,8192,16384
CONFigure:GPRF:MEASurement1:FFTSanalyzer:FFTLength?Read FFT Length. Reads the configured FFT length.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:DETector <Detector>Set FFT Detector. Defines how the spectrum diagram is calculated from the frequency domain samples.Text: PEAK,RMS
CONFigure:GPRF:MEASurement1:FFTSanalyzer:DETector?Read FFT Detector. Reads the detector used by the FFT spectrum analyzer.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:AMODe <Mode>Set FFT Averaging Mode. Selects whether the average traces are calculated from linear or logarithmic power values.Text: LINear,LOGarithmic
CONFigure:GPRF:MEASurement1:FFTSanalyzer:AMODe?Read FFT Averaging Mode. Reads the averaging mode of the FFT spectrum analyzer.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:REPetition <Repetition>Set FFT Repetition. Selects whether the FFT measurement is stopped after one cycle or repeated continuously.Text: SINGleshot,CONTinuous
CONFigure:GPRF:MEASurement1:FFTSanalyzer:REPetition?Read FFT Repetition. Reads the repetition mode of the FFT spectrum analyzer.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:SCOunt <Count>Set FFT Statistic Count. Specifies the number of measurement intervals per single shot for the FFT measurement (1 to 1000).Number
CONFigure:GPRF:MEASurement1:FFTSanalyzer:SCOunt?Read FFT Statistic Count. Reads the statistic count of the FFT measurement.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:TOUT <Seconds>Set FFT Timeout. Defines a timeout for the FFT measurement in seconds.Number
CONFigure:GPRF:MEASurement1:FFTSanalyzer:TOUT?Read FFT Timeout. Reads the FFT measurement timeout in seconds.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:MOEXception ONTurn On FFT Measure On Exception. Accepts faulty FFT results instead of rejecting them.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:MOEXception OFFTurn Off FFT Measure On Exception. Rejects faulty FFT results.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:MOEXception?Read FFT Measure On Exception. Reads whether faulty FFT results are accepted or rejected.None
CONFigure:GPRF:MEASurement1:SPECtrum:AMODe <Mode>Set Spectrum Averaging Mode. Defines how the average traces are calculated from the current spectrum results.Text: LINear,LOGarithmic
CONFigure:GPRF:MEASurement1:SPECtrum:AMODe?Read Spectrum Averaging Mode. Reads the averaging mode of the spectrum measurement.None
CONFigure:GPRF:MEASurement1:SPECtrum:REPetition <Repetition>Set Spectrum Repetition. Selects whether the spectrum measurement is stopped after one cycle or repeated continuously.Text: SINGleshot,CONTinuous
CONFigure:GPRF:MEASurement1:SPECtrum:REPetition?Read Spectrum Repetition. Reads the repetition mode of the spectrum measurement.None
CONFigure:GPRF:MEASurement1:SPECtrum:SCOunt <Count>Set Spectrum Statistic Count. Specifies the number of measurement intervals per single shot for the spectrum measurement (1 to 1000).Number
CONFigure:GPRF:MEASurement1:SPECtrum:SCOunt?Read Spectrum Statistic Count. Reads the statistic count of the spectrum measurement.None
CONFigure:GPRF:MEASurement1:SPECtrum:TOUT <Seconds>Set Spectrum Timeout. Defines a timeout for the spectrum measurement in seconds; 0 s means an infinite timeout.Number
CONFigure:GPRF:MEASurement1:SPECtrum:TOUT?Read Spectrum Timeout. Reads the spectrum measurement timeout in seconds.None
CONFigure:LTE:MEASurement1:RFSettings:EATTenuation <Atten>Set LTE Meas External Attenuation. Sets the external attenuation (or gain, if negative) at the LTE measurement input connector in dB (-50 dB to 90 dB).Number
CONFigure:LTE:MEASurement1:RFSettings:EATTenuation?Read LTE Meas External Attenuation. Reads the external attenuation of the LTE measurement input path in dB.None
CONFigure:LTE:MEASurement1:RFSettings:ENPower <Power>Set LTE Meas Expected Power. Sets the expected nominal power of the measured LTE uplink signal in dBm.Number
CONFigure:LTE:MEASurement1:RFSettings:ENPower?Read LTE Meas Expected Power. Reads the expected nominal power of the measured LTE uplink signal in dBm.None
CONFigure:LTE:MEASurement1:RFSettings:UMARgin <Margin>Set LTE Meas User Margin. Sets the margin added to the expected nominal power to determine the reference power in dB.Number
CONFigure:LTE:MEASurement1:RFSettings:UMARgin?Read LTE Meas User Margin. Reads the user margin of the LTE measurement in dB.None
CONFigure:LTE:MEASurement1:RFSettings:FOFFset <Offset>Set LTE Meas Frequency Offset. Specifies a frequency offset added to the carrier center frequency in Hz (-100 kHz to 100 kHz).Number
CONFigure:LTE:MEASurement1:RFSettings:FOFFset?Read LTE Meas Frequency Offset. Reads the frequency offset of the LTE measurement in Hz.None
CONFigure:LTE:MEASurement1:RFSettings:MLOFfset <Offset>Set LTE Meas Mixer Level Offset. Varies the input level of the mixer in the LTE analyzer path in dB (-10 dB to 10 dB).Number
CONFigure:LTE:MEASurement1:RFSettings:MLOFfset?Read LTE Meas Mixer Level Offset. Reads the mixer level offset of the LTE analyzer path in dB.None
CONFigure:LTE:MEASurement1:MEValuation:MMODe <Mode>Set LTE Meas Mode. Selects the LTE multi-evaluation measurement mode: normal, TPC, or multi-evaluation list mode.Text: NORMal,TMODe,MELMode
CONFigure:LTE:MEASurement1:MEValuation:MMODe?Read LTE Meas Mode. Reads the LTE multi-evaluation measurement mode.None
CONFigure:LTE:MEASurement1:MEValuation:REPetition <Repetition>Set LTE Meas Repetition. Selects whether the LTE multi-evaluation measurement is stopped after one cycle or repeated continuously.Text: SINGleshot,CONTinuous
CONFigure:LTE:MEASurement1:MEValuation:REPetition?Read LTE Meas Repetition. Reads the repetition mode of the LTE multi-evaluation measurement.None
CONFigure:LTE:MEASurement1:MEValuation:TOUT <Seconds>Set LTE Meas Timeout. Defines a timeout for the LTE multi-evaluation measurement in seconds.Number
CONFigure:LTE:MEASurement1:MEValuation:TOUT?Read LTE Meas Timeout. Reads the LTE multi-evaluation measurement timeout in seconds.None
CONFigure:LTE:MEASurement1:MEValuation:SCONdition <Condition>Set LTE Meas Stop Condition. Qualifies whether the LTE measurement is stopped after a limit failure or continues regardless.Text: NONE,SLFail
CONFigure:LTE:MEASurement1:MEValuation:SCONdition?Read LTE Meas Stop Condition. Reads the stop condition of the LTE multi-evaluation measurement.None
CONFigure:LTE:MEASurement1:MEValuation:CPRefix <Prefix>Set LTE Meas Cyclic Prefix. Selects the cyclic prefix type of the measured LTE uplink signal.Text: NORMal,EXTended
CONFigure:LTE:MEASurement1:MEValuation:CPRefix?Read LTE Meas Cyclic Prefix. Reads the cyclic prefix type used by the LTE measurement.None
CONFigure:LTE:MEASurement1:MEValuation:CTYPe <Type>Set LTE Meas Channel Type. Configures the uplink channel type detection of the LTE multi-evaluation measurement.Text: AUTO,PUSCh,PUCCh
CONFigure:LTE:MEASurement1:MEValuation:CTYPe?Read LTE Meas Channel Type. Reads the configured uplink channel type of the LTE measurement.None
CONFigure:LTE:MEASurement1:MEValuation:PFORmat <Format>Set LTE Meas PUCCH Format. Specifies the PUCCH format of the measured uplink signal according to 3GPP TS 36.211.Text: F1,F1A,F1B,F2,F2A,F2B,F3
CONFigure:LTE:MEASurement1:MEValuation:PFORmat?Read LTE Meas PUCCH Format. Reads the configured PUCCH format of the LTE measurement.None
CONFigure:LTE:MEASurement1:MEValuation:MSLot <Slot>Set LTE Meas Slot. Selects which slots of a subframe are measured by the LTE multi-evaluation measurement.Text: MS0,MS1,ALL
CONFigure:LTE:MEASurement1:MEValuation:MSLot?Read LTE Meas Slot. Reads the slots measured by the LTE multi-evaluation measurement.None
CONFigure:LTE:MEASurement1:MEValuation:SCOunt:MODulation <Count>Set LTE Meas Modulation Statistic Count. Specifies the statistic count of the modulation measurement in slots (1 to 1000).Number
CONFigure:LTE:MEASurement1:MEValuation:SCOunt:MODulation?Read LTE Meas Modulation Statistic Count. Reads the statistic count of the LTE modulation measurement.None
CONFigure:LTE:MEASurement1:MEValuation:SCOunt:POWer <Count>Set LTE Meas Power Statistic Count. Specifies the statistic count of the power measurement in subframes (1 to 1000).Number
CONFigure:LTE:MEASurement1:MEValuation:SCOunt:POWer?Read LTE Meas Power Statistic Count. Reads the statistic count of the LTE power measurement.None
CONFigure:LTE:MEASurement1:MEValuation:MOEXception ONTurn On LTE Meas On Exception. Accepts faulty LTE measurement results instead of rejecting them.None
CONFigure:LTE:MEASurement1:MEValuation:MOEXception OFFTurn Off LTE Meas On Exception. Rejects faulty LTE measurement results.None
CONFigure:LTE:MEASurement1:MEValuation:MOEXception?Read LTE Meas On Exception. Reads whether faulty LTE measurement results are accepted or rejected.None
CONFigure:NRSub:MEASurement1:BAND <Band>Set NR Meas Band. Selects the NR operating band (allowed values depend on the duplex mode).Text: OB1,OB2,OB3,OB5,OB7,OB8,OB12,OB20,OB28,OB38,OB40,OB41,OB66,OB71,OB77,OB78,OB79
CONFigure:NRSub:MEASurement1:BAND?Read NR Meas Band. Reads the selected NR operating band (allowed values depend on the duplex mode).None
CONFigure:NRSub:MEASurement1:MEValuation:DMODe <Mode>Set NR Meas Duplex Mode. Selects the duplex mode of the NR signal.Text: FDD,TDD
CONFigure:NRSub:MEASurement1:MEValuation:DMODe?Read NR Meas Duplex Mode. Reads the selected duplex mode of the NR signal.None
CONFigure:NRSub:MEASurement1:RFSettings:FREQuency <Frequency>Set NR Meas Frequency. Sets the analyzer center frequency in Hz.Number
CONFigure:NRSub:MEASurement1:RFSettings:FREQuency?Read NR Meas Frequency. Reads the analyzer center frequency in Hz.None
CONFigure:NRSub:MEASurement1:RFSettings:ENPower <Power>Set NR Meas Expected Power. Sets the expected nominal power of the measured NR signal in dBm.Number
CONFigure:NRSub:MEASurement1:RFSettings:ENPower?Read NR Meas Expected Power. Reads the expected nominal power of the measured NR signal in dBm.None
CONFigure:NRSub:MEASurement1:RFSettings:EATTenuation <Atten>Set NR Meas External Attenuation. Sets the external attenuation at the RF input in dB.Number: -50,90
CONFigure:NRSub:MEASurement1:RFSettings:EATTenuation?Read NR Meas External Attenuation. Reads the external attenuation at the RF input in dB.None
CONFigure:NRSub:MEASurement1:RFSettings:UMARgin <Margin>Set NR Meas User Margin. Sets the user margin added to the expected nominal power in dB.Number
CONFigure:NRSub:MEASurement1:RFSettings:UMARgin?Read NR Meas User Margin. Reads the user margin added to the expected nominal power in dB.None
CONFigure:NRSub:MEASurement1:MEValuation:CBANdwidth <Bandwidth>Set NR Meas Channel Bandwidth. Selects the NR channel bandwidth.Text: B005,B010,B015,B020,B025,B030,B040,B050,B060,B070,B080,B090,B100
CONFigure:NRSub:MEASurement1:MEValuation:CBANdwidth?Read NR Meas Channel Bandwidth. Reads the selected NR channel bandwidth.None
CONFigure:NRSub:MEASurement1:MEValuation:SCSPacing <Spacing>Set NR Meas Subcarrier Spacing. Selects the subcarrier spacing.Text: S15K,S30K,S60K
CONFigure:NRSub:MEASurement1:MEValuation:SCSPacing?Read NR Meas Subcarrier Spacing. Reads the selected subcarrier spacing.None
CONFigure:NRSub:MEASurement1:MEValuation:PLCid <Cell_ID>Set NR Meas Physical Cell ID. Sets the physical layer cell ID of the measured signal.Number: 0,1007
CONFigure:NRSub:MEASurement1:MEValuation:PLCid?Read NR Meas Physical Cell ID. Reads the physical layer cell ID of the measured signal.None
CONFigure:NRSub:MEASurement1:MEValuation:DFTPrecoding ONTurn On NR Meas DFT Precoding. Enables transform precoding (DFT-s-OFDM) of the measured PUSCH.None
CONFigure:NRSub:MEASurement1:MEValuation:DFTPrecoding OFFTurn Off NR Meas DFT Precoding. Disables transform precoding (CP-OFDM).None
CONFigure:NRSub:MEASurement1:MEValuation:NSUBframes <Number>Set NR Meas Subframes. Sets the number of subframes to be evaluated (1 to 250).Number: 1,250
CONFigure:NRSub:MEASurement1:MEValuation:NSUBframes?Read NR Meas Subframes. Reads the number of subframes to be evaluated (1 to 250).None
CONFigure:NRSub:MEASurement1:MEValuation:REPetition <Repetition>Set NR Meas Repetition. Selects single-shot or continuous NR multi-evaluation measurement.Text: SINGleshot,CONTinuous
CONFigure:NRSub:MEASurement1:MEValuation:REPetition?Read NR Meas Repetition. Reads the selection: single-shot or continuous NR multi-evaluation measurement.None
CONFigure:NRSub:MEASurement1:MEValuation:SCOunt:MODulation <Count>Set NR Meas Modulation Count. Sets the statistic count of modulation measurements in slots.Number: 1,1000
CONFigure:NRSub:MEASurement1:MEValuation:SCOunt:MODulation?Read NR Meas Modulation Count. Reads the statistic count of modulation measurements in slots.None
CONFigure:NRSub:MEASurement1:MEValuation:SCOunt:POWer <Count>Set NR Meas Power Count. Sets the statistic count of power measurements.Number
CONFigure:NRSub:MEASurement1:MEValuation:SCOunt:POWer?Read NR Meas Power Count. Reads the statistic count of power measurements.None
CONFigure:NRSub:MEASurement1:MEValuation:TOUT <Seconds>Set NR Meas Timeout. Defines a timeout for the measurement in seconds.Number
CONFigure:NRSub:MEASurement1:MEValuation:TOUT?Read NR Meas Timeout. Reads the timeout for the measurement in seconds.None
CONFigure:NRSub:MEASurement1:MEValuation:SCONdition <Condition>Set NR Meas Stop Condition. Defines whether the measurement stops on a limit failure.Text: NONE,SLFail
CONFigure:NRSub:MEASurement1:MEValuation:SCONdition?Read NR Meas Stop Condition. Reads whether the measurement stops on a limit failure.None
CONFigure:NRSub:MEASurement1:MEValuation:MOEXception ONTurn On NR Meas On Exception. Results identified as faulty are never rejected.None
CONFigure:NRSub:MEASurement1:MEValuation:MOEXception OFFTurn Off NR Meas On Exception. Faulty results are rejected.None
CONFigure:WLAN:MEASurement1:ISIGnal:STANdard <Standard>Set WLAN Meas Standard. Selects the IEEE 802.11 standard of the measured signal (b/g DSSS, a/g OFDM, n, ac, ax, p).Text: DSSS,LOFDm,HTOFdm,VHTofdm,HEOFdm,POFDm
CONFigure:WLAN:MEASurement1:ISIGnal:STANdard?Read WLAN Meas Standard. Reads the selected IEEE 802.11 standard of the measured signal (b/g DSSS, a/g OFDM, n, ac, ax, p).None
CONFigure:WLAN:MEASurement1:ISIGnal:BWIDth <Bandwidth>Set WLAN Meas Bandwidth. Selects the channel bandwidth of the measured signal.Text: BW05mhz,BW10mhz,BW20mhz,BW40mhz,BW80mhz,BW16mhz,BW88mhz
CONFigure:WLAN:MEASurement1:ISIGnal:BWIDth?Read WLAN Meas Bandwidth. Reads the selected channel bandwidth of the measured signal.None
CONFigure:WLAN:MEASurement1:RFSettings:FREQuency <Frequency>Set WLAN Meas Frequency. Sets the analyzer center frequency in Hz (center of the received WLAN channel).Number
CONFigure:WLAN:MEASurement1:RFSettings:FREQuency?Read WLAN Meas Frequency. Reads the analyzer center frequency in Hz (center of the received WLAN channel).None
CONFigure:WLAN:MEASurement1:RFSettings:FREQuency:BAND <Band>Set WLAN Meas Frequency Band. Selects the WLAN frequency band.Text: B24Ghz,B4GHz,B5GHz,B6GHz
CONFigure:WLAN:MEASurement1:RFSettings:FREQuency:BAND?Read WLAN Meas Frequency Band. Reads the selected WLAN frequency band.None
CONFigure:WLAN:MEASurement1:RFSettings:ENPower <Power>Set WLAN Meas Expected Power. Sets the expected nominal power of the measured RF signal in dBm.Number
CONFigure:WLAN:MEASurement1:RFSettings:ENPower?Read WLAN Meas Expected Power. Reads the expected nominal power of the measured RF signal in dBm.None
CONFigure:WLAN:MEASurement1:RFSettings:EATTenuation <Atten>Set WLAN Meas External Attenuation. Sets the external attenuation at the RF input in dB (-50 to 90).Number: -50,90
CONFigure:WLAN:MEASurement1:RFSettings:EATTenuation?Read WLAN Meas External Attenuation. Reads the external attenuation at the RF input in dB (-50 to 90).None
CONFigure:WLAN:MEASurement1:RFSettings:UMARgin <Margin>Set WLAN Meas User Margin. Sets the margin added to the expected nominal power to determine the reference power in dB.Number
CONFigure:WLAN:MEASurement1:RFSettings:UMARgin?Read WLAN Meas User Margin. Reads the margin added to the expected nominal power to determine the reference power in dB.None
CONFigure:WLAN:MEASurement1:MEValuation:REPetition <Repetition>Set WLAN Meas Repetition. Selects single-shot or continuous WLAN multi-evaluation measurement.Text: SINGleshot,CONTinuous
CONFigure:WLAN:MEASurement1:MEValuation:REPetition?Read WLAN Meas Repetition. Reads the selection: single-shot or continuous WLAN multi-evaluation measurement.None
CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:MODulation <Count>Set WLAN Meas Modulation Count. Sets the statistic count for modulation measurements (1 to 2000).Number: 1,2000
CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:MODulation?Read WLAN Meas Modulation Count. Reads the statistic count for modulation measurements (1 to 2000).None
CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:TSMask <Count>Set WLAN Meas Spectrum Mask Count. Sets the statistic count for the transmit spectrum mask measurement (1 to 1000).Number: 1,1000
CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:TSMask?Read WLAN Meas Spectrum Mask Count. Reads the statistic count for the transmit spectrum mask measurement (1 to 1000).None
CONFigure:WLAN:MEASurement1:MEValuation:TOUT <Seconds>Set WLAN Meas Timeout. Defines a timeout for the WLAN measurement in seconds.Number
CONFigure:WLAN:MEASurement1:MEValuation:TOUT?Read WLAN Meas Timeout. Reads the timeout for the WLAN measurement in seconds.None
CONFigure:WLAN:MEASurement1:MEValuation:SCONdition <Condition>Set WLAN Meas Stop Condition. Defines whether the measurement stops on a limit failure.Text: NONE,SLFail
CONFigure:WLAN:MEASurement1:MEValuation:SCONdition?Read WLAN Meas Stop Condition. Reads whether the measurement stops on a limit failure.None
CONFigure:WLAN:MEASurement1:MEValuation:MOEXception ONTurn On WLAN Meas On Exception. Results identified as faulty are never rejected.None
CONFigure:WLAN:MEASurement1:MEValuation:MOEXception OFFTurn Off WLAN Meas On Exception. Faulty results are rejected.None
CONFigure:BASE:FDCorrection:CTABle:CREate <Table_Name>, <Freq_Loss_Pairs>Create Correction Table. Creates a frequency-dependent attenuation table; pairs are <Frequency Hz>, <Correction dB> (e.g. 1E9, 0.5, 2E9, 0.7).Text; Text
CONFigure:BASE:FDCorrection:CTABle:DELete <Table_Name>Delete Correction Table. Deletes the named correction table.Text
CONFigure:BASE:FDCorrection:CTABle:CATalog?Read Correction Table Catalog. Returns the names of all existing correction tables.None
CONFigure:CMWS:FDCorrection:ACTivate:RX <Port>, <Table_Name>Activate Port Correction RX. Activates a correction table for the input direction of an RF port.Text: R11,R12,R13,R14,R15,R16,R17,R18; Text
CONFigure:CMWS:FDCorrection:ACTivate:TX <Port>, <Table_Name>Activate Port Correction TX. Activates a correction table for the output direction of an RF port.Text: R11,R12,R13,R14,R15,R16,R17,R18; Text
CONFigure:CMWS:FDCorrection:DEACtivate:RX <Port>Deactivate Port Correction RX. Deactivates the correction table of an RF port in input direction.Text: R11,R12,R13,R14,R15,R16,R17,R18
CONFigure:CMWS:FDCorrection:DEACtivate:TX <Port>Deactivate Port Correction TX. Deactivates the correction table of an RF port in output direction.Text: R11,R12,R13,R14,R15,R16,R17,R18
CONFigure:CMWS:FDCorrection:DEACtivate:ALLDeactivate All Port Corrections. Deactivates all port correction tables in both directions.None

Source (SOURce) (46)

CommandWhat it doesArguments
SOURce:GPRF:GENerator1:STATe ONTurn On Generator. Turns the GPRF RF generator on.None
SOURce:GPRF:GENerator1:STATe OFFTurn Off Generator. Turns the GPRF RF generator off.None
SOURce:GPRF:GENerator1:STATe?Read Generator State. Reads the generator state (OFF / PENDing / ON / RDY).None
SOURce:GPRF:GENerator1:STATe:ALL?Read Generator State All. Reads detailed generator state information including the main state and the synchronization state.None
SOURce:GPRF:GENerator1:BBMode <Mode>Set Generator Baseband Mode. Selects the baseband mode of the generator signal: unmodulated CW, dual tone, or ARB waveform playback.Text: CW,DTONe,ARB
SOURce:GPRF:GENerator1:BBMode?Read Generator Baseband Mode. Reads the currently selected generator baseband mode.None
SOURce:GPRF:GENerator1:RFSettings:FREQuency <Freq>Set Generator Frequency. Sets the frequency of the unmodulated RF carrier in Hz (70 MHz to 6 GHz depending on installed options).Number
SOURce:GPRF:GENerator1:RFSettings:FREQuency?Read Generator Frequency. Reads the RF generator carrier frequency in Hz.None
SOURce:GPRF:GENerator1:RFSettings:LEVel <Level>Set Generator Level. Sets the base RMS level of the RF generator in dBm.Number
SOURce:GPRF:GENerator1:RFSettings:LEVel?Read Generator Level. Reads the base RMS output level of the RF generator in dBm.None
SOURce:GPRF:GENerator1:RFSettings:EATTenuation <Atten>Set Generator External Attenuation. Sets the external attenuation (or gain, if negative) at the RF output connector in dB (-50 dB to 90 dB).Number
SOURce:GPRF:GENerator1:RFSettings:EATTenuation?Read Generator External Attenuation. Reads the external attenuation configured for the RF output path in dB.None
SOURce:GPRF:GENerator1:RFSettings:DGAin <Gain>Set Generator Digital Gain. Sets the digital gain of the RF generator in dB.Number
SOURce:GPRF:GENerator1:RFSettings:DGAin?Read Generator Digital Gain. Reads the digital gain of the RF generator in dB.None
SOURce:GPRF:GENerator1:RFSettings:PEPower?Read Generator Peak Envelope Power. Reads the peak envelope power of the generated signal in dBm.None
SOURce:GPRF:GENerator1:ARB:FILE <Filename>Select ARB Waveform File. Selects the ARB waveform file (.wv) to be played back in ARB baseband mode.Text
SOURce:GPRF:GENerator1:ARB:FILE?Read ARB Waveform File. Reads the name of the currently loaded ARB waveform file.None
SOURce:GPRF:GENerator1:ARB:FILE:DATE?Read ARB File Date. Reads the creation date stored in the loaded ARB waveform file.None
SOURce:GPRF:GENerator1:ARB:FILE:VERSion?Read ARB File Version. Reads the version of the loaded ARB waveform file.None
SOURce:GPRF:GENerator1:ARB:FILE:OPTion?Read ARB File Options. Reads the list of instrument options required to play back the loaded ARB waveform file.None
SOURce:GPRF:GENerator1:ARB:REPetition <Repetition>Set ARB Repetition. Defines whether the ARB waveform file is processed continuously or for a defined number of cycles.Text: CONTinuous,SINGle
SOURce:GPRF:GENerator1:ARB:REPetition?Read ARB Repetition. Reads the ARB repetition mode.None
SOURce:GPRF:GENerator1:ARB:CYCLes <Cycles>Set ARB Cycles. Defines how often the ARB file is processed in single-shot repetition mode (1 to 10000).Number
SOURce:GPRF:GENerator1:ARB:CYCLes?Read ARB Cycles. Reads the configured number of ARB playback cycles.None
SOURce:GPRF:GENerator1:ARB:FOFFset <Freq>Set ARB Frequency Offset. Sets the frequency offset imposed at the baseband during ARB generation in Hz.Number
SOURce:GPRF:GENerator1:ARB:FOFFset?Read ARB Frequency Offset. Reads the ARB baseband frequency offset in Hz.None
SOURce:GPRF:GENerator1:ARB:ASAMples <Samples>Set ARB Additional Samples. Extends the processing time of the waveform file by the specified number of samples.Number
SOURce:GPRF:GENerator1:ARB:ASAMples?Read ARB Additional Samples. Reads the number of additional samples appended to the waveform file.None
SOURce:GPRF:GENerator1:ARB:CRATe?Read ARB Clock Rate. Reads the clock rate of the loaded ARB waveform file in Hz.None
SOURce:GPRF:GENerator1:ARB:POFFset?Read ARB Peak Offset. Reads the peak offset of the loaded ARB waveform file in dB.None
SOURce:GPRF:GENerator1:ARB:LOFFset?Read ARB Level Offset. Reads the level offset (peak to average ratio) of the loaded ARB waveform file in dB.None
SOURce:GPRF:GENerator1:ARB:CRCProtect?Read ARB CRC Protection. Reads whether the loaded ARB waveform file contains a CRC checksum.None
SOURce:GPRF:GENerator1:ARB:STATus?Read ARB Segment Status. Reads the number of the ARB segment currently being processed.None
SOURce:GPRF:GENerator1:ARB:SCOunt?Read ARB Sample Count. Reads the progress of the ARB file processing as elapsed time and sample count.None
SOURce:GPRF:GENerator1:LIST ONTurn On List Mode. Enables the frequency/level list mode of the RF generator.None
SOURce:GPRF:GENerator1:LIST OFFTurn Off List Mode. Disables the frequency/level list mode of the RF generator.None
SOURce:GPRF:GENerator1:LIST?Read List Mode State. Reads whether the generator list mode is enabled.None
SOURce:GPRF:GENerator1:LIST:STARt <Index>Set List Start Index. Defines the index of the first frequency/level step processed in list mode (0 to 1999).Number
SOURce:GPRF:GENerator1:LIST:STARt?Read List Start Index. Reads the index of the first frequency/level step in list mode.None
SOURce:GPRF:GENerator1:LIST:STOP <Index>Set List Stop Index. Defines the index of the last frequency/level step processed in list mode (0 to 1999).Number
SOURce:GPRF:GENerator1:LIST:STOP?Read List Stop Index. Reads the index of the last frequency/level step in list mode.None
SOURce:GPRF:GENerator1:LIST:GOTO <Index>Set List Goto Index. Defines the start index used for the subsequent list cycles in continuous repetition mode (1 to 2000).Number
SOURce:GPRF:GENerator1:LIST:REPetition <Repetition>Set List Repetition. Defines how often the RF generator runs through the frequency/level list.Text: CONTinuous,SINGle
SOURce:GPRF:GENerator1:LIST:REPetition?Read List Repetition. Reads the list mode repetition setting.None
SOURce:GPRF:GENerator1:LIST:AINDex?Read List Active Index. Reads the list index currently being generated (0 to 19).None
SOURce:GPRF:GENerator1:LIST:COUNt?Read List Step Count. Reads the number of frequency/level steps configured in list mode (1 to 2000).None

Fetch (FETCh) (37)

CommandWhat it doesArguments
FETCh:GPRF:MEASurement1:POWer:STATe?Read Power Measurement State. Reads the main state of the power measurement (OFF / RUN / RDY).None
FETCh:GPRF:MEASurement1:POWer:STATe:ALL?Read Power Measurement State All. Reads the detailed power measurement state including the main state and the synchronization state.None
FETCh:GPRF:MEASurement1:POWer:CURRent?Fetch Power Current. Fetches the current power results of all measured segments in dBm without restarting the measurement.None
FETCh:GPRF:MEASurement1:POWer:CURRent:RMS?Fetch Power Current RMS. Fetches the current RMS power results in dBm.None
FETCh:GPRF:MEASurement1:POWer:AVERage?Fetch Power Average. Fetches the average power results of all measured segments in dBm.None
FETCh:GPRF:MEASurement1:POWer:AVERage:RMS?Fetch Power Average RMS. Fetches the average RMS power results in dBm.None
FETCh:GPRF:MEASurement1:POWer:MAXimum:CURRent?Fetch Power Maximum. Fetches the current-maximum power results (one value per measured segment) in dBm.None
FETCh:GPRF:MEASurement1:POWer:MINimum:CURRent?Fetch Power Minimum. Fetches the current-minimum power results (one value per measured segment) in dBm.None
FETCh:GPRF:MEASurement1:POWer:PEAK:MAXimum?Fetch Power Peak Maximum. Fetches the peak maximum power results in dBm.None
FETCh:GPRF:MEASurement1:POWer:PEAK:MINimum?Fetch Power Peak Minimum. Fetches the peak minimum power results in dBm.None
FETCh:GPRF:MEASurement1:POWer:SDEViation?Fetch Power Standard Deviation. Fetches the standard deviation of the power results in dB.None
FETCh:GPRF:MEASurement1:FFTSanalyzer:STATe?Read FFT Measurement State. Reads the main state of the FFT spectrum analyzer measurement.None
FETCh:GPRF:MEASurement1:FFTSanalyzer:POWer:CURRent?Fetch FFT Power Current. Fetches the current FFT spectrum trace as a list of 801 power values in dBm.None
FETCh:GPRF:MEASurement1:FFTSanalyzer:POWer:AVERage?Fetch FFT Power Average. Fetches the average FFT spectrum trace as a list of 801 power values in dBm.None
FETCh:GPRF:MEASurement1:FFTSanalyzer:POWer:MAXimum?Fetch FFT Power Maximum. Fetches the maximum-hold FFT spectrum trace in dBm.None
FETCh:GPRF:MEASurement1:FFTSanalyzer:POWer:MINimum?Fetch FFT Power Minimum. Fetches the minimum-hold FFT spectrum trace in dBm.None
FETCh:GPRF:MEASurement1:SPECtrum:STATe?Read Spectrum Measurement State. Reads the main state of the spectrum measurement.None
FETCh:GPRF:MEASurement1:SPECtrum:RMS:CURRent?Fetch Spectrum RMS Current. Fetches the current RMS spectrum trace in dBm.None
FETCh:GPRF:MEASurement1:SPECtrum:RMS:AVERage?Fetch Spectrum RMS Average. Fetches the average RMS spectrum trace in dBm.None
FETCh:GPRF:MEASurement1:SPECtrum:RMS:MAXimum?Fetch Spectrum RMS Maximum. Fetches the maximum-hold RMS spectrum trace in dBm.None
FETCh:GPRF:MEASurement1:SPECtrum:RMS:MINimum?Fetch Spectrum RMS Minimum. Fetches the minimum-hold RMS spectrum trace in dBm.None
FETCh:LTE:MEASurement1:MEValuation:STATe?Read LTE MultiEval State. Reads the main state of the LTE multi-evaluation measurement.None
FETCh:LTE:MEASurement1:MEValuation:MODulation:AVERage?Fetch LTE Modulation Average. Fetches the average modulation results: EVM, magnitude error, phase error, I/Q offset, frequency error, timing error and TX power.None
FETCh:NRSub:MEASurement1:MEValuation:STATe?Read NR MultiEval State. Returns the NR FR1 multi-evaluation measurement state: OFF, RUN or RDY.None
FETCh:NRSub:MEASurement1:MEValuation:MODulation:AVERage?Fetch NR Modulation Average. Returns the average single-value modulation results (EVM, magnitude/phase error, frequency error...).None
FETCh:NRSub:MEASurement1:MEValuation:TXPower:AVERage?Fetch NR TX Power Average. Returns the total TX power results.None
FETCh:NRSub:MEASurement1:MEValuation:ACLR:AVERage?Fetch NR ACLR Average. Returns the relative ACLR values.None
FETCh:NRSub:MEASurement1:MEValuation:SEMask:AVERage?Fetch NR Spectrum Emission Average. Returns the spectrum emission mask single-value results.None
FETCh:NRSub:MEASurement1:MEValuation:ESFLatness:AVERage?Fetch NR Spectrum Flatness Average. Returns the equalizer spectrum flatness single-value results.None
FETCh:NRSub:MEASurement1:MEValuation:IEMission:MARGin:AVERage?Fetch NR Inband Emission Margin. Returns the in-band emission limit line margins (negative = limit exceeded).None
FETCh:WLAN:MEASurement1:MEValuation:STATe?Read WLAN MultiEval State. Returns the WLAN multi-evaluation measurement state: OFF, RUN or RDY.None
FETCh:WLAN:MEASurement1:MEValuation:MODulation:AVERage?Fetch WLAN Modulation Average. Returns the average single-value modulation results (EVM, frequency/clock error, burst power...) for OFDM SISO signals.None
FETCh:WLAN:MEASurement1:MEValuation:MODulation:CURRent?Fetch WLAN Modulation Current. Returns the current single-value modulation results for OFDM SISO signals.None
FETCh:WLAN:MEASurement1:MEValuation:MODulation:DSSS:AVERage?Fetch WLAN DSSS Modulation Average. Returns the average single-value modulation results for DSSS (802.11b) signals.None
FETCh:WLAN:MEASurement1:MEValuation:TSMask:AVERage?Fetch WLAN Spectrum Mask Average. Returns the limit line margins of the transmit spectrum mask (positive = limit exceeded).None
FETCh:WLAN:MEASurement1:MEValuation:SFLatness:AVERage?Fetch WLAN Spectral Flatness Average. Returns the spectrum flatness margin values (positive = limit violated).None
FETCh:WLAN:MEASurement1:MEValuation:PVTime:REDGe:AVERage?Fetch WLAN PvT Rising Edge Average. Returns the rising edge ramp durations of the power vs time measurement.None

System (SYSTem) (14)

CommandWhat it doesArguments
SYSTem:BASE:REFerence:FREQuency:SOURce <Source>Set Reference Frequency Source. Selects the internal or an external reference frequency source for the instrument.Text: INTernal,EXTernal
SYSTem:BASE:REFerence:FREQuency:SOURce?Read Reference Frequency Source. Reads the selected reference frequency source.None
SYSTem:BASE:REFerence:FREQuency <Freq>Set External Reference Frequency. Sets the expected external reference frequency in Hz when the external reference source is selected.Number
SYSTem:BASE:REFerence:FREQuency?Read External Reference Frequency. Reads the expected external reference frequency in Hz.None
SYSTem:ERRor:ALL?Read Error Queue. Queries and deletes all entries in the error queue.None
SYSTem:ERRor:COUNt?Read Error Count. Queries the number of entries currently in the error queue.None
SYSTem:RESet:BASEReset Base Settings. Resets the base settings to the default values suitable for remote operation.None
SYSTem:RESet:ALLReset All Settings. Resets the entire instrument including the base settings and all firmware applications.None
SYSTem:PRESet:BASEPreset Base Settings. Presets the base settings to the default values suitable for manual operation.None
SYSTem:PRESet:ALLPreset All Settings. Presets the entire instrument including the base settings and all firmware applications.None
SYSTem:VERSion?Read SCPI Version. Queries the SCPI version number the instrument complies with.None
SYSTem:BASE:OPTion:LIST?Read Option List. Returns the list of installed software/hardware options and firmware applications.None
SYSTem:GENerator:ALL:OFFAll Generators Off. Switches off all running generators.None
SYSTem:MEASurement:ALL:OFFAll Measurements Off. Switches off all running measurements.None

ROUT subsystem (9)

CommandWhat it doesArguments
ROUTe:GPRF:GENerator1:SCENario:SALone <Connector>, <Converter>Route Generator Standalone. Selects the TX path of the generated signal: connector bench R118 (RF 1 to RF 8) and TX module; enable individual ports with Enable_Generator_Port.Text: R118; Text: TX1
ROUTe:GPRF:GENerator1:SCENario?Read Generator Scenario. Reads the active routing scenario of the GPRF generator.None
ROUTe:GPRF:MEASurement1:SCENario:SALone <Connector>, <Converter>Route Measurement Standalone. Activates the standalone scenario and selects the RF input port (RF 1 to RF 8 = R11 to R18) and RX module.Text: R11,R12,R13,R14,R15,R16,R17,R18; Text: RX1
ROUTe:GPRF:MEASurement1:SCENario?Read Measurement Scenario. Reads the active routing scenario of the GPRF measurement.None
ROUTe:LTE:MEASurement1:SCENario:SALone <Connector>,<Converter>Route LTE Measurement Standalone. Activates the standalone scenario and selects the RF input path for the LTE uplink measurement.Text: R11,R12,R13,R14,R15,R16,R17,R18; Text: RX1
ROUTe:LTE:MEASurement1:SCENario?Read LTE Measurement Scenario. Reads the active routing scenario of the LTE measurement application.None
ROUTe:NRSub:MEASurement1:SCENario:SALone <Connector>, <Converter>Route NR Measurement Standalone. Activates the standalone scenario and selects the RF input path for the NR FR1 uplink measurement.Text: R11,R12,R13,R14,R15,R16,R17,R18; Text: RX1
ROUTe:WLAN:MEASurement1:SCENario:SALone <Connector>, <Converter>Route WLAN Measurement Standalone. Activates the standalone scenario and selects the RF input connector and RX module for WLAN measurements.Text: R11,R12,R13,R14,R15,R16,R17,R18; Text: RX1
ROUTe:WLAN:MEASurement1:SCENario?Read WLAN Measurement Scenario. Returns the active WLAN measurement scenario.None

Initiate (INITiate) (6)

CommandWhat it doesArguments
INITiate:GPRF:MEASurement1:POWerStart Power Measurement. Starts or restarts the GPRF power measurement and puts it into the RUN state.None
INITiate:GPRF:MEASurement1:FFTSanalyzerStart FFT Measurement. Starts or restarts the FFT spectrum analyzer measurement.None
INITiate:GPRF:MEASurement1:SPECtrumStart Spectrum Measurement. Starts or restarts the spectrum measurement.None
INITiate:LTE:MEASurement1:MEValuationStart LTE MultiEval Measurement. Starts or restarts the LTE uplink multi-evaluation measurement.None
INITiate:NRSub:MEASurement1:MEValuationStart NR MultiEval. Starts or restarts the NR FR1 multi-evaluation measurement (state RUN).None
INITiate:WLAN:MEASurement1:MEValuationStart WLAN MultiEval. Starts or restarts the WLAN multi-evaluation measurement (state RUN).None

Run control (6)

CommandWhat it doesArguments
STOP:GPRF:MEASurement1:POWerStop Power Measurement. Halts the power measurement and puts it into the RDY state while keeping the results.None
STOP:GPRF:MEASurement1:FFTSanalyzerStop FFT Measurement. Halts the FFT measurement and keeps the results.None
STOP:GPRF:MEASurement1:SPECtrumStop Spectrum Measurement. Halts the spectrum measurement and keeps the results.None
STOP:LTE:MEASurement1:MEValuationStop LTE MultiEval Measurement. Halts the LTE multi-evaluation measurement and keeps the results.None
STOP:NRSub:MEASurement1:MEValuationStop NR MultiEval. Halts the NR FR1 multi-evaluation measurement; results are kept (state RDY).None
STOP:WLAN:MEASurement1:MEValuationStop WLAN MultiEval. Halts the WLAN multi-evaluation measurement; results are kept (state RDY).None

Abort (6)

CommandWhat it doesArguments
ABORt:GPRF:MEASurement1:POWerAbort Power Measurement. Halts the power measurement and puts it into the OFF state; all results are set to NAV.None
ABORt:GPRF:MEASurement1:FFTSanalyzerAbort FFT Measurement. Halts the FFT measurement and clears all results.None
ABORt:GPRF:MEASurement1:SPECtrumAbort Spectrum Measurement. Halts the spectrum measurement and clears all results.None
ABORt:LTE:MEASurement1:MEValuationAbort LTE MultiEval Measurement. Halts the LTE multi-evaluation measurement and clears all results.None
ABORt:NRSub:MEASurement1:MEValuationAbort NR MultiEval. Aborts the NR FR1 multi-evaluation measurement and releases resources (state OFF).None
ABORt:WLAN:MEASurement1:MEValuationAbort WLAN MultiEval. Aborts the WLAN multi-evaluation measurement and releases resources (state OFF).None

Read (READ) (6)

CommandWhat it doesArguments
READ:GPRF:MEASurement1:POWer:CURRent?Read Power Current. Starts the measurement and returns the current power results of all measured segments in dBm.None
READ:GPRF:MEASurement1:POWer:CURRent:RMS?Read Power Current RMS. Starts the measurement and returns the current RMS power results in dBm.None
READ:GPRF:MEASurement1:POWer:AVERage?Read Power Average. Starts the measurement and returns the average power results of all measured segments in dBm.None
READ:GPRF:MEASurement1:POWer:SDEViation?Read Power Standard Deviation. Starts the measurement and returns the standard deviation of the power results in dB.None
READ:GPRF:MEASurement1:FFTSanalyzer:POWer:AVERage?Read FFT Power Average. Starts the measurement and returns the average FFT spectrum trace in dBm.None
READ:LTE:MEASurement1:MEValuation:MODulation:AVERage?Read LTE Modulation Average. Starts the measurement and returns the average LTE uplink modulation results.None

Calculate (CALCulate) (2)

CommandWhat it doesArguments
CALCulate:GPRF:MEASurement1:POWer:AVERage?Calculate Power Average Limits. Returns the limit check results for the average power instead of the measured values.None
CALCulate:LTE:MEASurement1:MEValuation:MODulation:AVERage?Calculate LTE Modulation Average Limits. Returns the limit check results for the average LTE modulation measurement instead of the measured values.None

Sense (SENSe) (2)

CommandWhat it doesArguments
SENSe:BASE:REFerence:FREQuency:LOCKed?Read Reference Locked. Queries whether the instrument is locked to the selected reference frequency.None
SENSe:BASE:TEMPerature:OPERating:INTernal?Read Internal Temperature. Queries the average internal temperature measured at the RF modules in degrees C.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (11)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the current sub-instrument to its default state.None
*CLSClear Status. Clears the status byte, event registers and the output buffer.None
*ESR?Read Event Status Register. Returns the contents of the standard event status register (0 to 255) and clears it.None
*STB?Read Status Byte. Returns the contents of the status byte in decimal form.None
*OPCSet Operation Complete Bit. Sets bit 0 of the event status register when all preceding commands are complete.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete before continuing.None
*SAV <Memory>Save State. Stores the current instrument settings in intermediate memory 0 to 99.Number: 0,99
*RCL <Memory>Recall State. Recalls instrument settings from intermediate memory 0 to 99.Number: 0,99
*TRGTrigger Bus. Generates a software (bus) trigger event.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Rohde & Schwarz's programming documentation for the CMW100 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Rohde & Schwarz's programming manual: check it before you rely on an edge case. Last updated September 27, 2026.

Frequently asked questions

Does the Rohde & Schwarz CMW100 support SCPI remote control?

Yes. The Rohde & Schwarz CMW100 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 305 SCPI commands for it: 160 queries that read values or state, and 145 settings and actions.

How do I control the Rohde & Schwarz CMW100 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, SOURce:GPRF:GENerator1:STATe ON and CONFigure:GPRF:MEASurement1:RFSettings:FREQuency?.

Which command reads a value from the Rohde & Schwarz CMW100?

CONFigure:GPRF:MEASurement1:RFSettings:FREQuency? (read analyzer frequency). Reads the center frequency of the RF analyzer in Hz. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Rohde & Schwarz CMW100 without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Rohde & Schwarz CMW100 through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today